The Neuron-Spectrum-6G by Neurosoft is an advanced EEG system developed from 30 years of engineering experience and cutting-edge technologies. It offers superior input noise levels, frequency and amplitude ranges, and sampling frequencies, outperforming many clinical EEG machines. Designed for seamless integration with transcranial magnetic stimulation (TMS), it effectively records EEG and evoked potentials during TMS sessions without signal disruptions.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130187-8
Brands:: Neurosoft

Description

 

Features

Innovative EEG recorder with outstanding technical specifications

A new-generation EEG system, Neuron Spectrum-6G represents the 30-year experience of Neurosoft engineers and advanced technologies applied in the development of circuit solutions in medicine. The system outperforms most clinical EEG machines available today regarding such characteristics as input noise level, input frequency and amplitude range, and sampling frequency. Thanks to that and to the particularly developed software, it is possible to successfully use the system for TMS-EEG studies. The previous-generation EEG recorders usually went off-scale at the high-amplitude magnetic pulse and did not record an electroencephalogram. When designing this system, this disadvantage was fixed so that now the system allows recording of EEG and evoked potentials (EP) throughout a transcranial magnetic stimulation (TMS) session.

Non-interfering monophasic magnetic stimulator

For TMS-EEG sessions, we suggest using one of Neurosoft latest developments in magnetic stimulation. The monophasic stimulator ensures generation of high-amplitude pulses with high enough frequency. At the same time, its circuit is designed so that charging the capacitor does not cause additional interference in the EEG – the so-called “silent mode”. A variety of coils to choose from allow you to solve a wide range of clinical tasks.

Electrode system

An important success factor of the TMS-EEG technique is the appropriate electrode system. This solution offers a special electrode cap with the pre-defined electrode positions according to the 10-20 system for 21 or 32 EEG channels. The flat design of the electrodes allows positioning the coil as close to the head as possible, while the minimum metal content of the electrode allows minimizing artifact from the magnetic pulse on the EEG.

Software for recording, averaging, and analysis

 The Neuron-Spectrum.NET software implements the averaging of EPs induced by magnetic stimulation directly during recording. Automatic artifact removal from averaging allows obtaining pure responses for a minimum number of averagings. The latencies and amplitudes of EP components are calculated automatically and presented as tables and topographic maps. After the recording is completed, it is possible to change the filter parameters, perform averaging with different settings, for example, to remove pulse artifact from the averaged curves. The duration of a pulse artifact depends on the used electrodes, pulse intensity, and filter parameters. On average, artifact duration is 25 ms after pulse delivery, and immediately after that the system records pure EEG signal without interference.

Wide application possibilities

A few years ago when it became technically possible to record EEG during magnetic stimulation, TMS-EEG technique was only used in scientific research. Numerous works have now been published demonstrating the possibilities of this method in the treatment and diagnosis of various diseases. For example, TMS-EEG is widely used for evaluation of rehabilitation progress in stroke patients and helps in localization of the epileptic focus. The studies performed today using this technique allow suggesting that the scope of its application will expand even further in the future.

Reviews

There are no reviews yet.

Be the first to review “Neuron Spectrum-6G”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsNeuron Spectrum-6G removeRetractors removeEctron Ectonustim Series 6 Electroconvulsive Therapy ECT Machine removeBRAINSWAY Deep TMS H1 Coil removeDolphin-XF Transcranial Robotic Probe removeDolphin-4D Transcranial Doppler Probe remove
NameNeuron Spectrum-6G removeRetractors removeEctron Ectonustim Series 6 Electroconvulsive Therapy ECT Machine removeBRAINSWAY Deep TMS H1 Coil removeDolphin-XF Transcranial Robotic Probe removeDolphin-4D Transcranial Doppler Probe remove
Image
SKUSF1033560130187-8SF1033560130176-9SF10335601235SF1033560130162-4SF1033560130142-4SF1033560130142-1
Rating
Price

$0.00

$0.00

$0.00

$0.00

$6,270.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad The Neuron-Spectrum-6G by Neurosoft is an advanced EEG system developed from 30 years of engineering experience and cutting-edge technologies. It offers superior input noise levels, frequency and amplitude ranges, and sampling frequencies, outperforming many clinical EEG machines. Designed for seamless integration with transcranial magnetic stimulation (TMS), it effectively records EEG and evoked potentials during TMS sessions without signal disruptions.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad

This machines have been developed from the well-proven Series 5A and 5B ECT apparatus. The series 6+ models incorporate all the features of the corresponding Series 5B versions. Experience has shown that a very few patients sometimes require higher dosage than was available with the earlier machines and the opportunity was therefore taken to produce equipment with a second, higher, output range.

Delivery & Availability: Typically 3 Months – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
The H1 Coil stimulates the bilateral prefrontal cortex, with a preference for the left dorsolateral prefrontal cortex. In addition to numerous published, double-blind, randomized controlled trials validating the efficacy of Deep TMS for depression, clinical data of over 1,000 patients in real practice settings has shown compelling results. Among patients who completed 30 sessions, approximately 4 out of 5 achieved a clinical response, and approximately 2 out of 3 achieved remission from depression.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad Proudly introducing the X-Factor in TCD robotic solutions, assisting in obtaining bilateral TCD insonations in as quickly as just a few seconds!. Designed for short and long-term monitoring, for use in anesthesia, in the ICU, or in the TCD lab.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad The cutting-edge technology of the standalone Dolphin/4D transcranial Doppler system is the optimal TCD solution for measurements of cerebral blood flow velocities.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Contenthttps://youtu.be/L5JdV0DrKQs  
Features
Innovative EEG recorder with outstanding technical specifications A new-generation EEG system, Neuron Spectrum-6G represents the 30-year experience of Neurosoft engineers and advanced technologies applied in the development of circuit solutions in medicine. The system outperforms most clinical EEG machines available today regarding such characteristics as input noise level, input frequency and amplitude range, and sampling frequency. Thanks to that and to the particularly developed software, it is possible to successfully use the system for TMS-EEG studies. The previous-generation EEG recorders usually went off-scale at the high-amplitude magnetic pulse and did not record an electroencephalogram. When designing this system, this disadvantage was fixed so that now the system allows recording of EEG and evoked potentials (EP) throughout a transcranial magnetic stimulation (TMS) session. Non-interfering monophasic magnetic stimulator For TMS-EEG sessions, we suggest using one of Neurosoft latest developments in magnetic stimulation. The monophasic stimulator ensures generation of high-amplitude pulses with high enough frequency. At the same time, its circuit is designed so that charging the capacitor does not cause additional interference in the EEG – the so-called “silent mode”. A variety of coils to choose from allow you to solve a wide range of clinical tasks. Electrode system An important success factor of the TMS-EEG technique is the appropriate electrode system. This solution offers a special electrode cap with the pre-defined electrode positions according to the 10-20 system for 21 or 32 EEG channels. The flat design of the electrodes allows positioning the coil as close to the head as possible, while the minimum metal content of the electrode allows minimizing artifact from the magnetic pulse on the EEG. Software for recording, averaging, and analysis  The Neuron-Spectrum.NET software implements the averaging of EPs induced by magnetic stimulation directly during recording. Automatic artifact removal from averaging allows obtaining pure responses for a minimum number of averagings. The latencies and amplitudes of EP components are calculated automatically and presented as tables and topographic maps. After the recording is completed, it is possible to change the filter parameters, perform averaging with different settings, for example, to remove pulse artifact from the averaged curves. The duration of a pulse artifact depends on the used electrodes, pulse intensity, and filter parameters. On average, artifact duration is 25 ms after pulse delivery, and immediately after that the system records pure EEG signal without interference. Wide application possibilities A few years ago when it became technically possible to record EEG during magnetic stimulation, TMS-EEG technique was only used in scientific research. Numerous works have now been published demonstrating the possibilities of this method in the treatment and diagnosis of various diseases. For example, TMS-EEG is widely used for evaluation of rehabilitation progress in stroke patients and helps in localization of the epileptic focus. The studies performed today using this technique allow suggesting that the scope of its application will expand even further in the future.
CODE SIZE FINISH
01-01-02 12.8 cm sharp
This machines have been developed from the well-proven Series 5A and 5B ECT apparatus. The series 6+ models incorporate all the features of the corresponding Series 5B versions. Experience has shown that a very few patients sometimes require higher dosage than was available with the earlier machines and the opportunity was therefore taken to produce equipment with a second, higher, output range. Features: Constant Current stimulus Delivered Dosage Displayed Patient Dynamic Impedance Indicator Simple Single Dose Control Technical Specification: Input Supply: AC 100-120, 210-240 V 40/60 Hz Load: 70 W Apparatus Size: 305 x 170 x 105mm (12” x 6.5” x 4”) Weight: 3.24kg Low Range: 50-700mC @ 750mA High Range: 200-100mC @ 900mA Contents: Two-hand headpiece: 1 C.S lead: 1 Disposable electrodes: 50 Mains cable: 1 Operating & service manual: 1 Removable stand: 1  
Click Here To Download Catalogue
The BrainsWay Deep TMS H1 Coil is a transcranial magnetic stimulation (TMS) device that's used to treat depression and other mental disorders: 
  • Design
    The H1 Coil is a flexible, soft copper coil that's placed inside a helmet to stimulate the brain. The coil's design allows for a wider and deeper distribution of magnetic fields than traditional TMS coils.
  • Effectiveness
    The H1 Coil is effective in treating depression and has also been explored as a treatment for other conditions:
    • DepressionThe H1 Coil is FDA-cleared to treat major depressive disorder (MDD) in adults who haven't responded well to other antidepressant medications.
    • Other conditionsThe H1 Coil has been explored as a treatment for negative symptoms of schizophrenia, bipolar depression, and migraine.
  • Benefits
    The H1 Coil's design allows for greater neuron activation, which can lead to more effective stimulation and fewer targeting errors.
  • Safety
    The H1 Coil is considered a safe and effective clinical tool.
Features
  • Flexible base
    The H1 coil has a flexible base that can adapt to the shape of the patient's head. 
  • Tangential coil components
    The H1 coil has tangential coil components that are close to the brain targets. 
  • Parallel coil components
    The H1 coil has parallel coil components that direct the electric pulse beams. 
  • Electrical pulses
    The H1 coil has numerous electrical pulses that converge from various directions. 
  • Return paths
    The return paths of the electrical pulses are located at a distance from the target area. 
  • Stimulates the prefrontal cortex
    The H1 coil stimulates the bilateral prefrontal cortex, with a preference for the left dorsolateral prefrontal cortex (DLPFC). 
  • Deeper and broader stimulation
    The H1 coil's patented design enables deeper and broader stimulation than traditional TMS coils.
    Click here to download Brochure
https://youtu.be/JwSJvUVJrxo?si=6QkpitWAwvZZSwOM  
Description
The Dolphin/XF is a new breakthrough development in TCD robotics. It is designed to assist the user in quickly and automatically insonating and monitoring cerebral blood flow.
Features

Comfortable Headset

The unique Dolphin/XF robot fits the patient’s head with a soft and comfortable dedicated monitoring headset. The patient’s posture is of no limitation, and thus the patient can lay down, be seated, or stand up during the measurements with the robot without any discomfort or preventing factors in the headset.

Ultra Fast Scanning

Use the Fast Scan mode for rapid scanning within seconds. Or use the High-Resolution Scan option for a more detailed robotic search through the temporal or suboccipital windows. This latter option generates a “heat map” as a function of insonated depth, showing all of the identified blood flow velocities flowing either towards the probe or away from the probe. https://youtu.be/QsaSaUbh7as?si=Vky2fSg6Mc3Ft_ob

Ideal Monitoring Solution

The Dolphin/XF TCD robot is ideal for settings where short or long-term monitoring is required. This includes applications in:
  • Anesthesia and the Operating Room (OR),
  • HITS detection for longer-term applications, 
  • Specialty Test protocols such as Vasomotor Reactivity (VMR), Breath Holding or PFO testing for short term monitoring, 
  • Use in the ICU, or 
  • With SAH or Stroke patients where cerebral blood flow monitoring is of particular importance. 
https://youtu.be/b6dDU1mGQ8Q?si=md0GOLuI1mUt6ouv
https://youtu.be/Id0Ma1_lEo0?si=MmwcCTMMPZd_jf6h
Features of Dolphin TCD Machine

Best Quality Doppler

Fully digital Doppler technology with the amazing Dolphin TCD post-processing capabilities lets you review and replay the measured spectrum with audio at any depth. Unmatched clinical diagnosis capabilities.

Best TCD Robotic Probe

The unique Dolphin/XF robotic probe changes the Transcranial Doppler monitoring market as is known to date. Fast and simple scanning is achieved thanks to special algorithms and processes for blood flow detection. The Dolphin/XF robot is comfortable and stable, simplifying probe fixation and saving time.

Continuous Monitoring Made Easy

The Dolphin devices are well designed to assist the technician or physician in performing short or long-term Monitoring. The Dolphin Headset design comes with the unique probe Quick-Lock – the best locking solution. The Dolphin software is rich with quality features for optimal patient diagnosis, including a complete replay of the entire recording, placement of automatic and predefined markers, and availability of trends display.

Unbeatable Durability and Reliability

The Dolphin is considered by many as the most reliable Transcranial Doppler machine in the market. A range of high-quality Doppler probes is available for different clinical applications and optimal Doppler penetration of the temporal window.

Designed for Portability

The Dolphin TCD machines are the most portable TCD machine on the market. Dolphin/MAX and Dolphin/4D are slim, lightweight, and have a large 18″ Touch Screen, which can be seen from a distance in the ICU or other clinical settings. Their design allows you to simply hand carry them or use the VESA mount options to easily connect the TCD system to a cart or trolley. The Dolphin/MAX has a built-in integrated battery that lasts for hours.

Complete Network Connectivity

The unmatched Dolphin connectivity capabilities are ideal for hospital IT personnel and EMR / PACS administrators. The advanced Dolphin TCD networking abilities allow a simple plug-and-play operation to quickly configure connectivity with automated DICOM Worklist & Storage, Structured Report, and HL7. With unlimited Review Stations, measurements can be reanalyzed and interpreted from the comfort of your office. Final reporting can also be configured and finalized from any location.

Unmatched HITS Detection

Optimal and accurate counts of suspected embolic events using a high-resolution proprietary algorithm that simultaneously detects HITS (emboli events) in all gates! The numerous advanced analysis options of each suspected emboli include an extraordinary high-resolution power M Mode display during HITS detection (up to 50 times faster than the Doppler spectrum!).
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare