Neuron Spectrum-6G

$0.00

Shipped From Abroad

The Neuron-Spectrum-6G by Neurosoft is an advanced EEG system developed from 30 years of engineering experience and cutting-edge technologies. It offers superior input noise levels, frequency and amplitude ranges, and sampling frequencies, outperforming many clinical EEG machines. Designed for seamless integration with transcranial magnetic stimulation (TMS), it effectively records EEG and evoked potentials during TMS sessions without signal disruptions.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130187-8
Brands:: Neurosoft

Description

 

Features

Innovative EEG recorder with outstanding technical specifications

A new-generation EEG system, Neuron Spectrum-6G represents the 30-year experience of Neurosoft engineers and advanced technologies applied in the development of circuit solutions in medicine. The system outperforms most clinical EEG machines available today regarding such characteristics as input noise level, input frequency and amplitude range, and sampling frequency. Thanks to that and to the particularly developed software, it is possible to successfully use the system for TMS-EEG studies. The previous-generation EEG recorders usually went off-scale at the high-amplitude magnetic pulse and did not record an electroencephalogram. When designing this system, this disadvantage was fixed so that now the system allows recording of EEG and evoked potentials (EP) throughout a transcranial magnetic stimulation (TMS) session.

Non-interfering monophasic magnetic stimulator

For TMS-EEG sessions, we suggest using one of Neurosoft latest developments in magnetic stimulation. The monophasic stimulator ensures generation of high-amplitude pulses with high enough frequency. At the same time, its circuit is designed so that charging the capacitor does not cause additional interference in the EEG – the so-called “silent mode”. A variety of coils to choose from allow you to solve a wide range of clinical tasks.

Electrode system

An important success factor of the TMS-EEG technique is the appropriate electrode system. This solution offers a special electrode cap with the pre-defined electrode positions according to the 10-20 system for 21 or 32 EEG channels. The flat design of the electrodes allows positioning the coil as close to the head as possible, while the minimum metal content of the electrode allows minimizing artifact from the magnetic pulse on the EEG.

Software for recording, averaging, and analysis

 The Neuron-Spectrum.NET software implements the averaging of EPs induced by magnetic stimulation directly during recording. Automatic artifact removal from averaging allows obtaining pure responses for a minimum number of averagings. The latencies and amplitudes of EP components are calculated automatically and presented as tables and topographic maps. After the recording is completed, it is possible to change the filter parameters, perform averaging with different settings, for example, to remove pulse artifact from the averaged curves. The duration of a pulse artifact depends on the used electrodes, pulse intensity, and filter parameters. On average, artifact duration is 25 ms after pulse delivery, and immediately after that the system records pure EEG signal without interference.

Wide application possibilities

A few years ago when it became technically possible to record EEG during magnetic stimulation, TMS-EEG technique was only used in scientific research. Numerous works have now been published demonstrating the possibilities of this method in the treatment and diagnosis of various diseases. For example, TMS-EEG is widely used for evaluation of rehabilitation progress in stroke patients and helps in localization of the epileptic focus. The studies performed today using this technique allow suggesting that the scope of its application will expand even further in the future.

Reviews

There are no reviews yet.

Be the first to review “Neuron Spectrum-6G”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsNeuron Spectrum-6G removeFalcon-PRO Transcranial Doppler Probe removeDolphin-MAX Transcranial Doppler Probe removeDolphin-IQ Transcranial Doppler Probe removeBRAINSWAY Deep TMS 104 RCT System removeSomatics Electroconvulsive Therapy (ECT) Machine remove
NameNeuron Spectrum-6G removeFalcon-PRO Transcranial Doppler Probe removeDolphin-MAX Transcranial Doppler Probe removeDolphin-IQ Transcranial Doppler Probe removeBRAINSWAY Deep TMS 104 RCT System removeSomatics Electroconvulsive Therapy (ECT) Machine remove
Image
SKUSF1033560130187-8SF1033560130142-5SF1033560130142-2SF1033560130142-3SF1033560130162-3SF1033560106-1
Rating
Price

$0.00

$0.00

$0.00

$6,325.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad The Neuron-Spectrum-6G by Neurosoft is an advanced EEG system developed from 30 years of engineering experience and cutting-edge technologies. It offers superior input noise levels, frequency and amplitude ranges, and sampling frequencies, outperforming many clinical EEG machines. Designed for seamless integration with transcranial magnetic stimulation (TMS), it effectively records EEG and evoked potentials during TMS sessions without signal disruptions.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad

State-of-the-Art technology to measure Segmental Blood Pressures, ABI, TBI, Doppler, PVR, PPG and stress testing. Falcon advanced EMR and PACS capabilities and reporting options are designed for medical centers and private clinics alike.

Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad Transcranial Doppler machine with an integrated rechargeable battery. The Dolphin/MAX is the ideal portable TCD system for measurements of cerebral blood flow in Neurology, ICU, and Neurosurgery settings
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad All of the advantages and performance of the cutting-edge Dolphin TCD technology for measurements of cerebral blood flow velocities are implemented in the smart and compact Dolphin/IQ Transcranial Doppler module.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad BrainsWay's 104 RCT System enables blinded clinical research via a card reader that randomizes selection of sham or Deep TMS stimulation. The sham coil is integrated into the helmet with the treatment coil, producing similar sounds and sensations.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from abroad The machine provides higher stimulus current, deeper cerebral stimulus penetration, and better seizure generalization. It provides the most effective form of bilateral brief pulse ECT with a 0.5msec pulsewidth that minimizes side-effects and can be delivered at every stimulus dose including the maximum dose with efficient and accurate stimulus titration.
Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Contenthttps://youtu.be/L5JdV0DrKQs  
Features
Innovative EEG recorder with outstanding technical specifications A new-generation EEG system, Neuron Spectrum-6G represents the 30-year experience of Neurosoft engineers and advanced technologies applied in the development of circuit solutions in medicine. The system outperforms most clinical EEG machines available today regarding such characteristics as input noise level, input frequency and amplitude range, and sampling frequency. Thanks to that and to the particularly developed software, it is possible to successfully use the system for TMS-EEG studies. The previous-generation EEG recorders usually went off-scale at the high-amplitude magnetic pulse and did not record an electroencephalogram. When designing this system, this disadvantage was fixed so that now the system allows recording of EEG and evoked potentials (EP) throughout a transcranial magnetic stimulation (TMS) session. Non-interfering monophasic magnetic stimulator For TMS-EEG sessions, we suggest using one of Neurosoft latest developments in magnetic stimulation. The monophasic stimulator ensures generation of high-amplitude pulses with high enough frequency. At the same time, its circuit is designed so that charging the capacitor does not cause additional interference in the EEG – the so-called “silent mode”. A variety of coils to choose from allow you to solve a wide range of clinical tasks. Electrode system An important success factor of the TMS-EEG technique is the appropriate electrode system. This solution offers a special electrode cap with the pre-defined electrode positions according to the 10-20 system for 21 or 32 EEG channels. The flat design of the electrodes allows positioning the coil as close to the head as possible, while the minimum metal content of the electrode allows minimizing artifact from the magnetic pulse on the EEG. Software for recording, averaging, and analysis  The Neuron-Spectrum.NET software implements the averaging of EPs induced by magnetic stimulation directly during recording. Automatic artifact removal from averaging allows obtaining pure responses for a minimum number of averagings. The latencies and amplitudes of EP components are calculated automatically and presented as tables and topographic maps. After the recording is completed, it is possible to change the filter parameters, perform averaging with different settings, for example, to remove pulse artifact from the averaged curves. The duration of a pulse artifact depends on the used electrodes, pulse intensity, and filter parameters. On average, artifact duration is 25 ms after pulse delivery, and immediately after that the system records pure EEG signal without interference. Wide application possibilities A few years ago when it became technically possible to record EEG during magnetic stimulation, TMS-EEG technique was only used in scientific research. Numerous works have now been published demonstrating the possibilities of this method in the treatment and diagnosis of various diseases. For example, TMS-EEG is widely used for evaluation of rehabilitation progress in stroke patients and helps in localization of the epileptic focus. The studies performed today using this technique allow suggesting that the scope of its application will expand even further in the future.
https://youtu.be/YSWvhSIS1ho?si=ZVl2aB_GXgSRotbP
Features of Falcon Physiologic Machine

Segmental Blood Pressures

Measure lower extremity pressures easily with 10 color-coded channels and a variety of Doppler probes and PPG sensors. Complete the vascular diagnosis with supportive stress testing. Falcon is considered by many the best segmental pressure machine with numerous advanced features such as 10 simultaneous PVR measurements and limitless post-processing capabilities.

Fast and Accurate ABI & TBI

Quickly measure ABI and TBI with either Doppler or Photoplethysmography (PPG). With the Falcon ABI and TBI machine, all measurements are saved automatically and sent directly to the dedicated interactive summary screen.

High Quality Doppler Probes

In addition, to the 4 MHz and 8 MHz probes for standard use, the advanced Falcon Doppler machine offers a unique 10 MHz probe, which is designed to measure particularly small peripheral blood vessels. All Falcon Doppler probes produce complete high-resolution Doppler spectral analysis with the aid of the Falcon vascular software and algorithms.

State-of-the-Art PPG Sensors

Falcon offers a wide selection of Photoplethysmography sensors.   The 5 completely independent PPG ports allow simultaneous fingers/toes measurements, which is especially useful for Raynaud’s diagnosis along with a an integrated temperature sensor.  Fingerclip and Toeclip PPG sensors are recommended for routine examinations. The Disc PPG sensors are particularly useful for Venous Reflux testing and are supplied with dedicated adhesive stickers.

Highest Durability and Reliability

The Falcon is the most reliable peripheral vascular machine in the market.  Thanks to the high quality Doppler probes, 10 Independent Pressure Channels (IPU Technology) and 5 PPG Ports, the Falcon design significantly reduces any down-time. Falcon is in distributed worldwide for over 10 years with the lowest fail rate in the market!

Complete Network Connectivity

The Falcon unmatched connectivity capabilities are a paradise to hospital IT personnel and EMR and PACS managers. The advanced networking abilities allow a plug-and-play operation to easily configure connectivity with automated DICOM Worklist & Storage, Structured Report, and HL7. With unlimited Review Stations, measurements can be reanalyzed and interpreted from the comfort of your office. Final reporting can also be configured and finalized from any location.

Simplify Your Workflow

The Falcon vascular diagnosis device has the ability to configure as many dedicated examination protocols that allow to save time and optimize the patient vascular diagnosis​. Enjoy the user-friendly protocol builder to configure your workflow according to your needs!​

Ease of Use

Minimal learning curve thanks to user-friendly software with a large touch-screen display. A selection of wired and wireless remote control​ and footswitch allows keeping your focus on the patient rather than on the physiologic vascular equipment.

Dedicated Specialty Tests

The Falcon is the complete vascular physiologic assessment machine with dedicated protocols that guide you through step-by-step diagnostic measurements of specific vascular conditions.  The dedicated diagnosis protocols include measurements of Thoracic Outlet Syndrome (TOS), diagnosis of Raynaud’s Phenomenon, evaluation of Penile Function or Erectile Dysfunction, assessment of Allen’s Test (or Palmar Arch Test), measurements of Venous Reflux and Venous Capacitance and Outflow, Pulse Wave Velocity, and more.

Advanced Reporting

The famous Falcon user-friendly report builder tool allows you to design your own report layout easily. Then, add your institute/clinic logo and details to create a detailed and impressive diagnosis report that meets your institute standards. Save a lot of time by building your report with preconfigured interpretation templates.

Advanced Research Options

The Falcon vascular research machine is famous for its built-in statistics tool with on-screen graphs, segments filtering, and Excel tool, which are all designed to simplify the work of vascular and physiological researchers. Export to PDF, Excel, Word, JPEG, VSX, Video clips, and more to support your vascular research and teaching needs, as well as support your clinical vascular publications.
https://youtu.be/Id0Ma1_lEo0?si=-B5sGwSCDZOQi-ZO
Features of Dolphin TCD Machine

Best Quality Doppler

Fully digital Doppler technology with the amazing Dolphin TCD post-processing capabilities. Review and replay the blood flow waveforms with audio at ANY depth. Discover unmatched clinical diagnosis capabilities.

Best TCD Robotic Probe

The unique Dolphin/XF robotic probe changes the Transcranial Doppler monitoring market as is known to date. Fast and simple scanning is achieved thanks to special algorithms and processes for blood flow detection. The Dolphin/XF robot is comfortable and stable, simplifying probe fixation and saving time.

Continuous Monitoring Made Easy

The Dolphin TCD Products are designed to assist in performing short or long-term patient monitoring. The famous Dolphin Quick-Lock provides the best locking solution. The TCD software is rich with quality features for optimal patient diagnosis.

Unbeatable Durability and Reliability

The Dolphin is considered by many as the most reliable Transcranial Doppler machine in the market. Robust TCD equipment and high-quality Doppler probes are designed for all TCD clinical applications.

Designed for Portability

The slim and lightweight design of the Dolphin TCD machines allows ideal and comfortable portability. The large touch screen can easily be seen from a distance. Mounting the TCD on a trolley is simple and easy. The Dolphin/MAX has a built-in integrated battery that lasts for hours.

Complete Network Connectivity

The unmatched Dolphin connectivity capabilities are ideal for hospital IT personnel and EMR / PACS administrators. Simple plug-and-play operation allows connectivity configuration with automated DICOM Worklist & Storage, Structured Report, and HL7. Unlimited Review Stations for interpretation and reporting in the comfort of your office.

Unmatched HITS Detection

Simultaneous counts of suspected embolic events in all depth gates using a high-resolution proprietary algorithm. Includes numerous advanced emboli analysis options with the proprietary super high-resolution power M Mode display during HITS detection.
https://youtu.be/Id0Ma1_lEo0?si=kRJ1bUMjUCBuCAqR  
Features of Dolphin TCD Machine

Best Quality Doppler

Fully digital Doppler technology with the amazing Dolphin TCD post-processing capabilities lets you review and replay the measured spectrum with audio at any depth. Unmatched clinical diagnosis capabilities.

Best TCD Robotic Probe

The unique Dolphin/XF robotic probe changes the Transcranial Doppler monitoring market as is known to date. Fast and simple scanning is achieved thanks to special algorithms and processes for blood flow detection. The Dolphin/XF robot is comfortable and stable, simplifying probe fixation and saving time.

Continuous Monitoring Made Easy

The Dolphin devices are well designed to assist the technician or physician in performing short or long-term Monitoring. The Dolphin Headset design comes with the unique probe Quick-Lock – the best locking solution. The Dolphin software is rich with quality features for optimal patient diagnosis, including a complete replay of the entire recording, placement of automatic and predefined markers, and availability of trends display.

Unbeatable Durability and Reliability

The Dolphin is considered by many as the most reliable Transcranial Doppler machine in the market. A range of high-quality Doppler probes is available for different clinical applications and optimal Doppler penetration of the temporal window.

Designed for Portability

The Dolphin TCD machines are the most portable TCD machine on the market. Dolphin/MAX and Dolphin/4D are slim, lightweight, and have a large 18″ Touch Screen, which can be seen from a distance in the ICU or other clinical settings. Their design allows you to simply hand carry them or use the VESA mount options to easily connect the TCD system to a cart or trolley. The Dolphin/MAX has a built-in integrated battery that lasts for hours.

Complete Network Connectivity

The unmatched Dolphin connectivity capabilities are ideal for hospital IT personnel and EMR / PACS administrators. The advanced Dolphin TCD networking abilities allow a simple plug-and-play operation to quickly configure connectivity with automated DICOM Worklist & Storage, Structured Report, and HL7. With unlimited Review Stations, measurements can be reanalyzed and interpreted from the comfort of your office. Final reporting can also be configured and finalized from any location.

Unmatched HITS Detection

Optimal and accurate counts of suspected embolic events using a high-resolution proprietary algorithm that simultaneously detects HITS (emboli events) in all gates! The numerous advanced analysis options of each suspected emboli include an extraordinary high-resolution power M Mode display during HITS detection (up to 50 times faster than the Doppler spectrum!).
The BrainsWay Deep TMS 104 RCT System is a non-invasive treatment for mental health conditions that uses magnetic pulses to stimulate the brain.
  • ComponentsIncludes a stimulator, touchscreen interface, cooling system, and card reader 
  • TreatmentPatients wear a helmet with electromagnetic coils that deliver magnetic pulses to the brain 
  • PurposeTreats conditions like major depressive disorder (MDD), obsessive-compulsive disorder (OCD), and smoking cessation 
  • SafetyWell-tolerated treatment with a favorable safety profile 
  • EffectivenessResearch shows that Deep TMS is effective in alleviating symptoms 
  • InsuranceMany insurance providers offer coverage for Deep TMS 
  • Ease of useDesigned to be easy to use for operators and comfortable for patients 
  • Sham-enabledVersions are available for randomized controlled clinical research 
 
Features
The BrainsWay Deep TMS 104 RCT System has several features, including:
  • H-CoilsThe system's patented H-Coils are flexible and embedded in a cushioned, cooled helmet that fits each patient's head. The H-Coils provide deeper and broader stimulation than traditional TMS coils, which are rigid and shaped like a figure-8. 
  • Touchscreen interfaceThe system has an intuitive touchscreen interface. 
  • Cooling systemThe system has an efficient cooling system. 
  • Card readerThe system has a card reader that randomly selects sham or Deep TMS stimulation. 
  • Sham-enabled versionsSham-enabled versions are available for randomized controlled clinical research.
 

Click here to download Brochure 

The machine provides higher stimulus current, deeper cerebral stimulus penetration, and better seizure generalization. It provides the most effective form of bilateral brief pulse ECT with a 0.5msec pulsewidth that minimizes side-effects and can be delivered at every stimulus dose including the maximum dose with efficient and accurate stimulus titration. Features-
  • Choose 0.25, 0.3 or 0.5msec Ultrabrief Pulsewidth
  • Genie™ IV EEG Analyzing Software
  • Four (4) - Channel Monitor/Printer
  • Optimal Stimulus Programs
  • Maximum Sustained EEG Amplitude
  • Continuous Digital Heart Rate Monitor
  • Peak Heart Rate Printout
  • EEG Coherence Analysis
  • Seizure Energy Index
  • Postictal Suppression Index
  • Maximum Dose Available at all Pulsewidths
  • Interictal Frontal Delta Analysis
  • Computer EEG Seizure Duration
  • Computer Motor Seizure Duration
  • True EMG Monitor
  • EEG Ictal Line Seizure Indicator
  • Light-Emitting Elapsed Time Display
  • Up to 8 Seconds of Stimulation
  • Change Waveform without Altering Dose
  • Audible EEG™ monitor
  • Instant Impedance Test
  • Extended Seizure Alert
  • Patented Safety Monitor Circuit
ECT Machine with Standard Accessories below: Article           Qty      Description                                                                           SYS-IV            1                     Thymatron System IV , with following accessories: EGEN              1         Genie-IV EEG Analyzing Software ELDS9            1                     Set with 9 lead wires  (4 red / 4 black / 1 green) EPAD              10       Disposable ECT treatment electrodes "Thymapad" (5 Pair) ECEF-IV        1                     EEG/EMG/ECG-monitoring cable ECET-IV        1                     ECT-treatment cable EEDS              50       Pregelled EEG/EMG stick-on electrodes EMGD           2                     Mouthguard oral protectors, 2 sizes CP110            2         Z-fold chart paper EDVD             1         Audio training DVD EMAE             2         Operating manual English ESERV           1         Service manual English For further treatments you can order separately following accessories: EECU/EEFL - Stainless steel electrode, cupped (EECU) or flat (EEFL) EHST- Headstrap, latex rubber, perforated EHAN-Electrode handle, fully shielded, for flat or cupped electrode.
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare