NEUROSTIM-Transcranial Electrical Stimulator

$0.00

Shipped From Abroad

NEUROSTIM is a Transcranial Electrical Stimulator (TES) designed for neuromodulation, neuroprotection, and rehabilitation. It delivers precise electrical stimulation to targeted brain areas, aiding in motor cortex mapping, neurological recovery, and cognitive enhancement. Ideal for neurologists, neurosurgeons, and rehabilitation specialists, NEUROSTIM ensures safe, effective, and customizable stimulation for both clinical and research applications. With its advanced technology and user-friendly interface, it enhances treatment precision and patient outcomes in neuroscience and neurorehabilitation.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130187-33
Brands:: Neurosoft

Description

DC output current – up to 2mA

Neurostim is intended for the transcranial noninvasive stimulation with direct low current (up to 2 mA).

The current generates the electrical field changing the brain cortex excitability. Such brain impact has therapeutic effect in the treatment of different disorders including fibromyalgia, major depressive episode, addiction/craving, lower limb neuropathic pain and recovery of motor functions after stroke and brain injuries.

Continuous monitoring of electrode impedance

It is very important to keep the reliable skin-electrode contact during the whole stimulation procedure. Poor electrode contact due to improper electrode placement or dry-out can result in decreased therapeutic effect.  Neurostim ensures continuous impedance monitoring. If the electrode impedance is too high, a notification will sound and the stimulation will be terminated (paused).

Two modes of use: inpatient  and outpatient

For inpatient treatment Neurostim is supplied with pre-defined treatment protocols for most commonly used therapy. Just select the protocol for the particular patient from the list.

For outpatient treatment you should create a treatment course (up to 250 stimulation sessions). A patient will start the treatment sessions one by one. The completed session will be locked and cannot be used for the treatment.

USB connection for advanced control

The software can be used to control and adjust stimulator through USB. In this mode the stimulator is also powered through USB.  The software is a simple way to manage the session list. You can add, remove, edit, import and export session, download user-defined waveform.

Features
  • smulus current – up to 5 mA (30 V)
  • smulaon duraon – up to 40 min
  • smulus type:
  • tDCS (transcranial direct current smulaon)
  • tACS (transcranial alternang current smulaon)
  • tRNS (transcranial random noise smulaon)
  • tDCS-Sham (transcranial direct current smulaon + sham)
  •  tPCS (transcranial pulse current smulaon) custom waveform
  • secure administrator mode to set up sessions
  • operaon modes:
  • stand-alone
  • USB-controlled (smulaon by specified protocol; creaon and eding of smulaon protocols)
Specifications
  • 1 channel transcranial smulator for unipolar (DC) and bipolar (AC) smulaon
  • adjustable smulus current of 0 up to 5 mA with 25 µA increment
  • adjustable smulaon duraon of 15 s to 40 min with 5 s increment
  • 16 bit D/A conversion
  • sampling rate:
    tACS – 33 kHz
    tRNS – 10 kHz
    tDCS – 500 Hz
    tPCS – 10 kHz
  • storage – 250 smulaon sessions
  •  power supply: from 9 V baery of 6LR61 or HR22 type or rechargeable batteries (up to 3 hours)
    from USB of +5 V (galvanically isolated up to 4000 V)

Download Brochure

Reviews

There are no reviews yet.

Be the first to review “NEUROSTIM-Transcranial Electrical Stimulator”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsNEUROSTIM-Transcranial Electrical Stimulator removeBRAINSWAY Deep TMS H7 Coil removeSomatics Electroconvulsive Therapy (ECT) Machine removeBRAINSWAY Deep TMS H7 RCT Coil removeFalcon-PRO Transcranial Doppler Probe removeDF-25W-HM Bipap remove
NameNEUROSTIM-Transcranial Electrical Stimulator removeBRAINSWAY Deep TMS H7 Coil removeSomatics Electroconvulsive Therapy (ECT) Machine removeBRAINSWAY Deep TMS H7 RCT Coil removeFalcon-PRO Transcranial Doppler Probe removeDF-25W-HM Bipap remove
Image
SKUSF1033560130187-33SF1033560130162-5SF1033560106-1SF1033560130162-6SF1033560130142-5SF1033560130180-3
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad NEUROSTIM is a Transcranial Electrical Stimulator (TES) designed for neuromodulation, neuroprotection, and rehabilitation. It delivers precise electrical stimulation to targeted brain areas, aiding in motor cortex mapping, neurological recovery, and cognitive enhancement. Ideal for neurologists, neurosurgeons, and rehabilitation specialists, NEUROSTIM ensures safe, effective, and customizable stimulation for both clinical and research applications. With its advanced technology and user-friendly interface, it enhances treatment precision and patient outcomes in neuroscience and neurorehabilitation.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad The H7 Coil stimulates the anterior cingulate cortex and the medial prefrontal cortex. Complementing a large-scale, double-blind, multicenter randomized controlled trial, which demonstrated strong response rates, greater than 1 in 2 OCD patients who completed 29 sessions in real clinical practice achieved sustained response.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from abroad The machine provides higher stimulus current, deeper cerebral stimulus penetration, and better seizure generalization. It provides the most effective form of bilateral brief pulse ECT with a 0.5msec pulsewidth that minimizes side-effects and can be delivered at every stimulus dose including the maximum dose with efficient and accurate stimulus titration.
Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Shipped From Abroad The H7 Coil stimulates the anterior cingulate cortex and the medial prefrontal cortex.  Treatment is designed to regulate the CSTC circuit believed to be involved in the inhibition of impulsive behavior. A sham coil is integrated above the treatment coil. To the patient and operator, the helmet appears the same, pulses sound the same, and stimulation feels the same on the scalp.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad

State-of-the-Art technology to measure Segmental Blood Pressures, ABI, TBI, Doppler, PVR, PPG and stress testing. Falcon advanced EMR and PACS capabilities and reporting options are designed for medical centers and private clinics alike.

Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad The VentMed DF-25W-HM BiPAP is an advanced auto BiPAP machine designed for sleep apnea therapy. It features multiple therapy modes, including CPAP, Auto, Auto S, S, T, and ST, making it adaptable to different patient needs. The machine ensures comfortable breathing with adjustable pressure settings (4-25 cmH2O) and an integrated humidification system with five levels to prevent dryness.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
ContentDC output current – up to 2mA Neurostim is intended for the transcranial noninvasive stimulation with direct low current (up to 2 mA). The current generates the electrical field changing the brain cortex excitability. Such brain impact has therapeutic effect in the treatment of different disorders including fibromyalgia, major depressive episode, addiction/craving, lower limb neuropathic pain and recovery of motor functions after stroke and brain injuries. Continuous monitoring of electrode impedance It is very important to keep the reliable skin-electrode contact during the whole stimulation procedure. Poor electrode contact due to improper electrode placement or dry-out can result in decreased therapeutic effect.  Neurostim ensures continuous impedance monitoring. If the electrode impedance is too high, a notification will sound and the stimulation will be terminated (paused). Two modes of use: inpatient  and outpatient For inpatient treatment Neurostim is supplied with pre-defined treatment protocols for most commonly used therapy. Just select the protocol for the particular patient from the list. For outpatient treatment you should create a treatment course (up to 250 stimulation sessions). A patient will start the treatment sessions one by one. The completed session will be locked and cannot be used for the treatment. USB connection for advanced control The software can be used to control and adjust stimulator through USB. In this mode the stimulator is also powered through USB.  The software is a simple way to manage the session list. You can add, remove, edit, import and export session, download user-defined waveform.
Features
  • smulus current – up to 5 mA (30 V)
  • smulaon duraon – up to 40 min
  • smulus type:
  • tDCS (transcranial direct current smulaon)
  • tACS (transcranial alternang current smulaon)
  • tRNS (transcranial random noise smulaon)
  • tDCS-Sham (transcranial direct current smulaon + sham)
  •  tPCS (transcranial pulse current smulaon) custom waveform
  • secure administrator mode to set up sessions
  • operaon modes:
  • stand-alone
  • USB-controlled (smulaon by specified protocol; creaon and eding of smulaon protocols)
Specifications
  • 1 channel transcranial smulator for unipolar (DC) and bipolar (AC) smulaon
  • adjustable smulus current of 0 up to 5 mA with 25 µA increment
  • adjustable smulaon duraon of 15 s to 40 min with 5 s increment
  • 16 bit D/A conversion
  • sampling rate: tACS – 33 kHz tRNS – 10 kHz tDCS – 500 Hz tPCS – 10 kHz
  • storage – 250 smulaon sessions
  •  power supply: from 9 V baery of 6LR61 or HR22 type or rechargeable batteries (up to 3 hours) from USB of +5 V (galvanically isolated up to 4000 V)
Download Brochure
The BrainsWay Deep TMS H7 Coil is a flexible coil used in transcranial magnetic stimulation (TMS) to stimulate the brain's medial prefrontal cortex and anterior cingulate cortex:
The H7 Coil stimulates the anterior cingulate cortex and the medial prefrontal cortex. Treatment is designed to regulate the CSTC circuit believed to be involved in the inhibition of impulsive behavior. A sham coil is integrated above the treatment coil.
  • What it does
    The H7 Coil is FDA-cleared to treat obsessive-compulsive disorder (OCD). It can also be used to treat other neuropsychiatric disorders, such as addiction, major depressive disorder, and autism spectrum disorder. 
  • How it works
    TMS uses magnetic pulses to induce an electrical current in the brain's neuronal tissue. The H7 Coil is integrated into a cooled, cushioned helmet that allows the patient to move around during treatment. 
  • How it's used
    The H7 Coil is designed to reach deeper and broader regions of the brain than previous TMS coils. The treatment is non-invasive and well-tolerated, with no adverse or long-lasting side effects. 
  • How it's delivered
    The treatment involves multiple sessions, each lasting about 18 minutes.
    Click here to download Brochure
The machine provides higher stimulus current, deeper cerebral stimulus penetration, and better seizure generalization. It provides the most effective form of bilateral brief pulse ECT with a 0.5msec pulsewidth that minimizes side-effects and can be delivered at every stimulus dose including the maximum dose with efficient and accurate stimulus titration. Features-
  • Choose 0.25, 0.3 or 0.5msec Ultrabrief Pulsewidth
  • Genie™ IV EEG Analyzing Software
  • Four (4) - Channel Monitor/Printer
  • Optimal Stimulus Programs
  • Maximum Sustained EEG Amplitude
  • Continuous Digital Heart Rate Monitor
  • Peak Heart Rate Printout
  • EEG Coherence Analysis
  • Seizure Energy Index
  • Postictal Suppression Index
  • Maximum Dose Available at all Pulsewidths
  • Interictal Frontal Delta Analysis
  • Computer EEG Seizure Duration
  • Computer Motor Seizure Duration
  • True EMG Monitor
  • EEG Ictal Line Seizure Indicator
  • Light-Emitting Elapsed Time Display
  • Up to 8 Seconds of Stimulation
  • Change Waveform without Altering Dose
  • Audible EEG™ monitor
  • Instant Impedance Test
  • Extended Seizure Alert
  • Patented Safety Monitor Circuit
ECT Machine with Standard Accessories below: Article           Qty      Description                                                                           SYS-IV            1                     Thymatron System IV , with following accessories: EGEN              1         Genie-IV EEG Analyzing Software ELDS9            1                     Set with 9 lead wires  (4 red / 4 black / 1 green) EPAD              10       Disposable ECT treatment electrodes "Thymapad" (5 Pair) ECEF-IV        1                     EEG/EMG/ECG-monitoring cable ECET-IV        1                     ECT-treatment cable EEDS              50       Pregelled EEG/EMG stick-on electrodes EMGD           2                     Mouthguard oral protectors, 2 sizes CP110            2         Z-fold chart paper EDVD             1         Audio training DVD EMAE             2         Operating manual English ESERV           1         Service manual English For further treatments you can order separately following accessories: EECU/EEFL - Stainless steel electrode, cupped (EECU) or flat (EEFL) EHST- Headstrap, latex rubber, perforated EHAN-Electrode handle, fully shielded, for flat or cupped electrode.
Click Here To Download Catalogue
The Brainsway Deep TMS H7 RCT Coil is a flexible coil used in transcranial magnetic stimulation (TMS) to treat obsessive-compulsive disorder (OCD) and other neuropsychiatric conditions:
  • What it does
    The H7 Coil stimulates the medial prefrontal cortex and the anterior cingulate cortex of the brain. TMS uses magnetic pulses to create an electrical current in the brain's neuronal tissue. 
  • How it's used
    The H7 Coil is integrated into a cooled, cushioned helmet that allows the patient to move around during treatment. A sham coil is also included so that the patient and operator can't tell the difference between the treatment and sham coils. 
  • What it's used for
    The H7 Coil is FDA-cleared for OCD, but it's also been shown to be effective in treating other conditions, including addiction, major depressive disorder, and autism spectrum disorder. 
  • How it works
    The H7 Coil is designed to regulate the CSTC circuit, which is thought to be involved in impulsive behavior. 
  • Safety
    A 2023 paper that analyzed adverse events from five large, randomized controlled trials found that most adverse events were transient and resolved within days.
Features
  • Stimulates specific brain regions
    The H7 Coil targets the anterior cingulate cortex and the medial prefrontal cortex. 
  • Flexible windings
    The H7 Coil's flexible windings conform to the shape of the patient's head. 
  • FDA-cleared for OCD
    The H7 Coil is FDA-cleared for treating obsessive-compulsive disorder (OCD). 
  • Demonstrated efficacy
    The H7 Coil has been shown to be effective in treating OCD patients with varying degrees of severity and comorbidities. 
  • Integrated sham coil
    The helmet includes a sham coil that makes the treatment appear, sound, and feel the same to the patient and operator.

Click here to download Brochure

https://youtu.be/YSWvhSIS1ho?si=ZVl2aB_GXgSRotbP
Features of Falcon Physiologic Machine

Segmental Blood Pressures

Measure lower extremity pressures easily with 10 color-coded channels and a variety of Doppler probes and PPG sensors. Complete the vascular diagnosis with supportive stress testing. Falcon is considered by many the best segmental pressure machine with numerous advanced features such as 10 simultaneous PVR measurements and limitless post-processing capabilities.

Fast and Accurate ABI & TBI

Quickly measure ABI and TBI with either Doppler or Photoplethysmography (PPG). With the Falcon ABI and TBI machine, all measurements are saved automatically and sent directly to the dedicated interactive summary screen.

High Quality Doppler Probes

In addition, to the 4 MHz and 8 MHz probes for standard use, the advanced Falcon Doppler machine offers a unique 10 MHz probe, which is designed to measure particularly small peripheral blood vessels. All Falcon Doppler probes produce complete high-resolution Doppler spectral analysis with the aid of the Falcon vascular software and algorithms.

State-of-the-Art PPG Sensors

Falcon offers a wide selection of Photoplethysmography sensors.   The 5 completely independent PPG ports allow simultaneous fingers/toes measurements, which is especially useful for Raynaud’s diagnosis along with a an integrated temperature sensor.  Fingerclip and Toeclip PPG sensors are recommended for routine examinations. The Disc PPG sensors are particularly useful for Venous Reflux testing and are supplied with dedicated adhesive stickers.

Highest Durability and Reliability

The Falcon is the most reliable peripheral vascular machine in the market.  Thanks to the high quality Doppler probes, 10 Independent Pressure Channels (IPU Technology) and 5 PPG Ports, the Falcon design significantly reduces any down-time. Falcon is in distributed worldwide for over 10 years with the lowest fail rate in the market!

Complete Network Connectivity

The Falcon unmatched connectivity capabilities are a paradise to hospital IT personnel and EMR and PACS managers. The advanced networking abilities allow a plug-and-play operation to easily configure connectivity with automated DICOM Worklist & Storage, Structured Report, and HL7. With unlimited Review Stations, measurements can be reanalyzed and interpreted from the comfort of your office. Final reporting can also be configured and finalized from any location.

Simplify Your Workflow

The Falcon vascular diagnosis device has the ability to configure as many dedicated examination protocols that allow to save time and optimize the patient vascular diagnosis​. Enjoy the user-friendly protocol builder to configure your workflow according to your needs!​

Ease of Use

Minimal learning curve thanks to user-friendly software with a large touch-screen display. A selection of wired and wireless remote control​ and footswitch allows keeping your focus on the patient rather than on the physiologic vascular equipment.

Dedicated Specialty Tests

The Falcon is the complete vascular physiologic assessment machine with dedicated protocols that guide you through step-by-step diagnostic measurements of specific vascular conditions.  The dedicated diagnosis protocols include measurements of Thoracic Outlet Syndrome (TOS), diagnosis of Raynaud’s Phenomenon, evaluation of Penile Function or Erectile Dysfunction, assessment of Allen’s Test (or Palmar Arch Test), measurements of Venous Reflux and Venous Capacitance and Outflow, Pulse Wave Velocity, and more.

Advanced Reporting

The famous Falcon user-friendly report builder tool allows you to design your own report layout easily. Then, add your institute/clinic logo and details to create a detailed and impressive diagnosis report that meets your institute standards. Save a lot of time by building your report with preconfigured interpretation templates.

Advanced Research Options

The Falcon vascular research machine is famous for its built-in statistics tool with on-screen graphs, segments filtering, and Excel tool, which are all designed to simplify the work of vascular and physiological researchers. Export to PDF, Excel, Word, JPEG, VSX, Video clips, and more to support your vascular research and teaching needs, as well as support your clinical vascular publications.
Key features:
  • Real-time Monitoring: Tracks therapy data and displays reports on the 3.5-inch color screen.
  • Smart Alarms: Alerts for mask leaks, apnea events, and pressure irregularities.
  • Heated Breathing Tube: Ensures even temperature distribution (10-30°C) to enhance comfort.
  • Bluetooth & IoT Connectivity: Allows remote monitoring and data uploads for treatment tracking.
  • Leak Compensation & High Trigger Sensitivity: Improves ventilation efficiency.
  • Low Noise Level (<29dB): Provides quiet operation for uninterrupted sleep.
  • Compact & Lightweight: Weighs 1.7 kg, making it easy to transport.
 
Specifications
Feature Details
Model VentMed DF-25W-HM
Therapy Modes CPAP, Auto, Auto S, S, T, ST
Pressure Range 4 - 25 cmH₂O
Screen 3.5-inch color display
Humidifier Levels 0 - 5 (adjustable)
Expiratory Pressure 4 - 25 cmH₂O
Inspiratory Pressure 4 - 25 cmH₂O
Tubing Heating Yes
Leak Compensation Yes
Smart Alarms Mask leaks, apnea events, pressure irregularities
Connectivity Bluetooth, IoT, mobile network support
Data Storage Cloud platform integration for reports
I/E Ratio 10% - 90%
Pressure Rise/Fall Time 100ms - 900ms
Noise Level < 29 dB (ultra-quiet operation)
Weight Approx. 1.7 kg (compact & lightweight)
Power Source Electric
Material ABS+PC shell
Certification CE Certified
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare