NEUROSTIM is a Transcranial Electrical Stimulator (TES) designed for neuromodulation, neuroprotection, and rehabilitation. It delivers precise electrical stimulation to targeted brain areas, aiding in motor cortex mapping, neurological recovery, and cognitive enhancement. Ideal for neurologists, neurosurgeons, and rehabilitation specialists, NEUROSTIM ensures safe, effective, and customizable stimulation for both clinical and research applications. With its advanced technology and user-friendly interface, it enhances treatment precision and patient outcomes in neuroscience and neurorehabilitation.
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
DC output current – up to 2mA
Neurostim is intended for the transcranial noninvasive stimulation with direct low current (up to 2 mA).
The current generates the electrical field changing the brain cortex excitability. Such brain impact has therapeutic effect in the treatment of different disorders including fibromyalgia, major depressive episode, addiction/craving, lower limb neuropathic pain and recovery of motor functions after stroke and brain injuries.
Continuous monitoring of electrode impedance
It is very important to keep the reliable skin-electrode contact during the whole stimulation procedure. Poor electrode contact due to improper electrode placement or dry-out can result in decreased therapeutic effect. Neurostim ensures continuous impedance monitoring. If the electrode impedance is too high, a notification will sound and the stimulation will be terminated (paused).
Two modes of use: inpatient and outpatient
For inpatient treatment Neurostim is supplied with pre-defined treatment protocols for most commonly used therapy. Just select the protocol for the particular patient from the list.
For outpatient treatment you should create a treatment course (up to 250 stimulation sessions). A patient will start the treatment sessions one by one. The completed session will be locked and cannot be used for the treatment.
USB connection for advanced control
The software can be used to control and adjust stimulator through USB. In this mode the stimulator is also powered through USB. The software is a simple way to manage the session list. You can add, remove, edit, import and export session, download user-defined waveform.
Features
- smulus current – up to 5 mA (30 V)
- smulaon duraon – up to 40 min
- smulus type:
- tDCS (transcranial direct current smulaon)
- tACS (transcranial alternang current smulaon)
- tRNS (transcranial random noise smulaon)
- tDCS-Sham (transcranial direct current smulaon + sham)
- tPCS (transcranial pulse current smulaon) custom waveform
- secure administrator mode to set up sessions
- operaon modes:
- stand-alone
- USB-controlled (smulaon by specified protocol; creaon and eding of smulaon protocols)
Specifications
- 1 channel transcranial smulator for unipolar (DC) and bipolar (AC) smulaon
- adjustable smulus current of 0 up to 5 mA with 25 µA increment
- adjustable smulaon duraon of 15 s to 40 min with 5 s increment
- 16 bit D/A conversion
- sampling rate:
tACS – 33 kHz
tRNS – 10 kHz
tDCS – 500 Hz
tPCS – 10 kHz - storage – 250 smulaon sessions
- power supply: from 9 V baery of 6LR61 or HR22 type or rechargeable batteries (up to 3 hours)
from USB of +5 V (galvanically isolated up to 4000 V)
Quick Comparison
NEUROSTIM-Transcranial Electrical Stimulator remove | ND-8S EEG Monitor remove | Nitrogen Generator/Plant remove | BRAINSWAY Deep TMS H7 Coil remove | Somatics Electroconvulsive Therapy (ECT) Machine remove | DF-20A-HM Auto CPAP remove | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | NEUROSTIM-Transcranial Electrical Stimulator remove | ND-8S EEG Monitor remove | Nitrogen Generator/Plant remove | BRAINSWAY Deep TMS H7 Coil remove | Somatics Electroconvulsive Therapy (ECT) Machine remove | DF-20A-HM Auto CPAP remove | ||||||||||||||||||||
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||||||||||||||||
SKU | SF1033560130187-33 | SF103356013077 | SF1033560130162-5 | SF1033560106-1 | SF1033560130180-5 | |||||||||||||||||||||
Rating | ||||||||||||||||||||||||||
Price |
|
|
|
|
|
| ||||||||||||||||||||
Stock | ||||||||||||||||||||||||||
Availability | ||||||||||||||||||||||||||
Add to cart | ||||||||||||||||||||||||||
Description | Shipped From Abroad
NEUROSTIM is a Transcranial Electrical Stimulator (TES) designed for neuromodulation, neuroprotection, and rehabilitation. It delivers precise electrical stimulation to targeted brain areas, aiding in motor cortex mapping, neurological recovery, and cognitive enhancement. Ideal for neurologists, neurosurgeons, and rehabilitation specialists, NEUROSTIM ensures safe, effective, and customizable stimulation for both clinical and research applications. With its advanced technology and user-friendly interface, it enhances treatment precision and patient outcomes in neuroscience and neurorehabilitation.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
PSA Industrıal nitrogen generator systems produce gas nitrogen from compressed air from the field where they work, and switch compatible to conventional nitrogen gas source such as tubes or cryogenic liqiud.
Delivery & Availability:
Typically, 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
The H7 Coil stimulates the anterior cingulate cortex and the medial prefrontal cortex. Complementing a large-scale, double-blind, multicenter randomized controlled trial, which demonstrated strong response rates, greater than 1 in 2 OCD patients who completed 29 sessions in real clinical practice achieved sustained response.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from abroad
The machine provides higher stimulus current, deeper cerebral stimulus penetration, and better seizure generalization. It provides the most effective form of bilateral brief pulse ECT with a 0.5msec pulsewidth that minimizes side-effects and can be delivered at every stimulus dose including the maximum dose with efficient and accurate stimulus titration.
| Shipped From Abroad
The VentMed DF-20A-HM Auto CPAP is designed for sleep apnea therapy, offering automatic pressure adjustment for comfortable breathing support. It includes a heated humidifier and has an ultra-low noise level of 22 dBA, ensuring quiet operation.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| ||||||||||||||||||||
Content | DC output current – up to 2mA
Neurostim is intended for the transcranial noninvasive stimulation with direct low current (up to 2 mA).
The current generates the electrical field changing the brain cortex excitability. Such brain impact has therapeutic effect in the treatment of different disorders including fibromyalgia, major depressive episode, addiction/craving, lower limb neuropathic pain and recovery of motor functions after stroke and brain injuries.
Continuous monitoring of electrode impedance
It is very important to keep the reliable skin-electrode contact during the whole stimulation procedure. Poor electrode contact due to improper electrode placement or dry-out can result in decreased therapeutic effect. Neurostim ensures continuous impedance monitoring. If the electrode impedance is too high, a notification will sound and the stimulation will be terminated (paused).
Two modes of use: inpatient and outpatient
For inpatient treatment Neurostim is supplied with pre-defined treatment protocols for most commonly used therapy. Just select the protocol for the particular patient from the list.
For outpatient treatment you should create a treatment course (up to 250 stimulation sessions). A patient will start the treatment sessions one by one. The completed session will be locked and cannot be used for the treatment.
USB connection for advanced control
The software can be used to control and adjust stimulator through USB. In this mode the stimulator is also powered through USB. The software is a simple way to manage the session list. You can add, remove, edit, import and export session, download user-defined waveform.
Features
Specifications
| FeaturesHIE multi-dimensional identification and application 1) According to the amplitude and continuity of the upper/lower boundary of aEEG, the neonatal EEG activity will be classified, and the Hellstrom-Westas background five-classification method will be used to improve the ability of medical staff to identify the aEEG waveforms; 2) Masimo Rainbow SET pulse oximetry monitoring, monitor the SpO2/PI/PR change in a non-invasive and continuous manner, effectively eliminate the exercise interference, and improve the measurement performance under low perfusion and body motion.
| PSA Industrıal nitrogen generator systems produce gas nitrogen from compressed air from the field where they work, and switch compatible to conventional nitrogen gas source such as tubes or cryogenic liqiud.
ADVANTAGES OF NITROGEN GENERATORS/PLANT
Wide Range Of Applications
![]() | The BrainsWay Deep TMS H7 Coil is a flexible coil used in transcranial magnetic stimulation (TMS) to stimulate the brain's medial prefrontal cortex and anterior cingulate cortex:
The H7 Coil stimulates the anterior cingulate cortex and the medial prefrontal cortex. Treatment is designed to regulate the CSTC circuit believed to be involved in the inhibition of impulsive behavior. A sham coil is integrated above the treatment coil.
| The machine provides higher stimulus current, deeper cerebral stimulus penetration, and better seizure generalization. It provides the most effective form of bilateral brief pulse ECT with a 0.5msec pulsewidth that minimizes side-effects and can be delivered at every stimulus dose including the maximum dose with efficient and accurate stimulus titration.
Features-
Click Here To Download Catalogue | Specifications:
This device is lightweight and user-friendly, featuring an intuitive display and advanced noise-canceling technology for a comfortable sleep experience | ||||||||||||||||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||
Additional information |
Reviews
There are no reviews yet.