PCR Cabinet

$0.00

Shipped From Abroad

PCR cabinet are designed to reduce the risk of contamination while performing Polymerase Chain Reaction (PCR) experiments, it direct HEPA-filtered air downward over the work area to provide ISO Class 5 (formerly Class 100) conditions and protect your work during preparatory procedures and amplifications.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130127-40
Brands:: Scitek

Description

PCR Cabinet Features:
  1. Perforations at the back wall of the work zone which are designed to eliminate air turbulence and the possibility of dead air corners in the work zone.
  2. Variable digital timer that provides UV light exposure continuously or in user-selected increments of 15, 30, 60,120 till 999 minutes to deactivate DNA and RNA contaminants.
  3. Intuitive and easy-to-use microprocessor controller with LCD display, graphical and digital display of all the operating status of each function, such as filter life, UV life etc.
  4. Ergonomic control panel location, centered and angled down for an easy reach & viewing.
  5. The non-direct light source design can effectively relieve the operator’s visual fatigue under the condition of ensuring the illumination.
  6. Different sizes available from 2 feet to 6 feet, benchtop use or mounted on a mobile base.
  7. Brushed stainless steel work surface is for easy cleaning.
Safety Performance:
  1. Audio and visual alarm on filter life, UV life etc.
  2. Front sliding sash interlock with fan and UV lamp.
  3. Front sash and side windows are made of UV-resistant tempered glass.
  4. The host and sockets have independent capacitors to prevent current overload.
Humanized design:
  1. Standard shelves with IV bar.
  2. Memory function in case of power-failure.
  3. HEPA filter and UV life indicators facilitate a timely replacem ent plan.
  4. Two sides glass windows installed for easy experiment observation.
  5. Easy-to-change pre-filter installed could extend the HEPA filter’s lifetime.
  6. Equipped with temperature sensor to show the real temperature during operation.
  7. Waterproof socket provide convenience for small instruments to be used in the operating area.
PCR Cabinet Specifications:
Model PCR-800 PCR-1100 PCR-1300 PCR-1600 PCR-1900
External Size (WxDxH)(mm) 710x680x1050 (Without Base Stand)
710x680x1670 (With Base Stand)
1050x710x1850 1320x710x1850 1625x710x1850 1930x710x1850
Internal Size (WxDxH)(mm) 610x590x625 950x615x625 1220x615x625 1525x615x625 1830x615x625
Work Surface Height 750mm
Control System Microprocessor controller with LCD display, graphical and digital display of the operating status
Audio and visual alarm on filter and UV changing
Front sliding sash interlock with fan and UV lamp
HEPA filter and UV life indicators facilitate a timely replacement plan
Air Filtration System Cleanness ISO Class 5 (Formerly Class 100)
Airflow Velocity 0.2~0.5 m/s, speed adjustable
HEPA Filter 1 pcs, efficiency > 99.995% at particle size of 0.3 μm
Pre-Filter 1 pcs, made of washable polyester fiber
Partial Air Circulation Perforations at the back wall of the work zone which are designed to eliminate air turbulence and the possibility of dead air corners in the work zone.
Sound Emission ≤62dB(A)
Illuminating Lamp LED Type, Illumination ≥900Lx
UV Decontamination System 1. With timing function from 0 to 999 minutes
2. Interlock with front sliding sash.
3. Emission of 253.7 nanometers for best sterilization effect.
10Wx2 20Wx1 30Wx1 30Wx1 20Wx2
Power Consumption 149W 155W 285W 285W 300W
External devices connected via power sockets are not included
Cabinet Structure Main Body: Electro-Galvanized steel with antimicrobial powder coating
Work Zone: 304 Stainless steel, an angled front, rounded work surface front edge
Side Windows: 5 mm UV resistant tempered glass
Power Supply AC220V ±10%, 50/60Hz, 1P
Standard Accessories LED lamp; UV lampx2; Waterproof socket×2 (only 1 for PCR-800); Shelves with IV bar
Optional Accessories Base stand(only PCR-800); Water tap, Gas tap, Height adjustable base stand
Net Weight 80kg(Without
base stand), 130kg (With base stand)
Gross Weight 115kg (Without base stand), 165kg (With base stand) 225kg 255kg 285kg 330kg
Shipping Size (W×D×H mm) 920x850x1190 1190x990x1325 1460x990x1325 1765x990x1325 2070x990x1325
Shipping Volume 0.93m3 1.56m3 1.92m3 2.3m3 2.7m3

 

Reviews

There are no reviews yet.

Be the first to review “PCR Cabinet”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsPCR Cabinet removeDiscover 5 Panel Cup with Adulterants Per Pack removePlastic Urine Container Per Pack removeTest Strip for ApexBio HemoSmart Gold Hemoglobin Meter removeSkyla HB1 POC Clinical Chemistry Auto Analyzer removeiSED Fully Automated ESR Analyzer remove
NamePCR Cabinet removeDiscover 5 Panel Cup with Adulterants Per Pack removePlastic Urine Container Per Pack removeTest Strip for ApexBio HemoSmart Gold Hemoglobin Meter removeSkyla HB1 POC Clinical Chemistry Auto Analyzer removeiSED Fully Automated ESR Analyzer remove
ImageDrug Test Cup
SKUSF1033560130127-40SF1033560084-23SF1033560084-106SF1033560084-30SF1033560060-1SF1033560084-129
Rating
Price

$0.00

$0.00

$8.20

$9.50

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad PCR cabinet are designed to reduce the risk of contamination while performing Polymerase Chain Reaction (PCR) experiments, it direct HEPA-filtered air downward over the work area to provide ISO Class 5 (formerly Class 100) conditions and protect your work during preparatory procedures and amplifications.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self-contained and the entire cup is tamper resistant. Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Total Volume: 60mL.
  • Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
  • Made of premium PP material, it is durable for usage.
  • Some measurements can be used to not only use urine samples, it can also be used for other liquids.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock Twenty Five (25) Test Strip per Pack

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The skyla HB1 Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. The portable design of the clinical chemistry analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
PCR Cabinet Features:
  1. Perforations at the back wall of the work zone which are designed to eliminate air turbulence and the possibility of dead air corners in the work zone.
  2. Variable digital timer that provides UV light exposure continuously or in user-selected increments of 15, 30, 60,120 till 999 minutes to deactivate DNA and RNA contaminants.
  3. Intuitive and easy-to-use microprocessor controller with LCD display, graphical and digital display of all the operating status of each function, such as filter life, UV life etc.
  4. Ergonomic control panel location, centered and angled down for an easy reach & viewing.
  5. The non-direct light source design can effectively relieve the operator's visual fatigue under the condition of ensuring the illumination.
  6. Different sizes available from 2 feet to 6 feet, benchtop use or mounted on a mobile base.
  7. Brushed stainless steel work surface is for easy cleaning.
Safety Performance:
  1. Audio and visual alarm on filter life, UV life etc.
  2. Front sliding sash interlock with fan and UV lamp.
  3. Front sash and side windows are made of UV-resistant tempered glass.
  4. The host and sockets have independent capacitors to prevent current overload.
Humanized design:
  1. Standard shelves with IV bar.
  2. Memory function in case of power-failure.
  3. HEPA filter and UV life indicators facilitate a timely replacem ent plan.
  4. Two sides glass windows installed for easy experiment observation.
  5. Easy-to-change pre-filter installed could extend the HEPA filter’s lifetime.
  6. Equipped with temperature sensor to show the real temperature during operation.
  7. Waterproof socket provide convenience for small instruments to be used in the operating area.
PCR Cabinet Specifications:
Model PCR-800 PCR-1100 PCR-1300 PCR-1600 PCR-1900
External Size (WxDxH)(mm) 710x680x1050 (Without Base Stand) 710x680x1670 (With Base Stand) 1050x710x1850 1320x710x1850 1625x710x1850 1930x710x1850
Internal Size (WxDxH)(mm) 610x590x625 950x615x625 1220x615x625 1525x615x625 1830x615x625
Work Surface Height 750mm
Control System Microprocessor controller with LCD display, graphical and digital display of the operating status
Audio and visual alarm on filter and UV changing
Front sliding sash interlock with fan and UV lamp
HEPA filter and UV life indicators facilitate a timely replacement plan
Air Filtration System Cleanness ISO Class 5 (Formerly Class 100)
Airflow Velocity 0.2~0.5 m/s, speed adjustable
HEPA Filter 1 pcs, efficiency > 99.995% at particle size of 0.3 μm
Pre-Filter 1 pcs, made of washable polyester fiber
Partial Air Circulation Perforations at the back wall of the work zone which are designed to eliminate air turbulence and the possibility of dead air corners in the work zone.
Sound Emission ≤62dB(A)
Illuminating Lamp LED Type, Illumination ≥900Lx
UV Decontamination System 1. With timing function from 0 to 999 minutes 2. Interlock with front sliding sash. 3. Emission of 253.7 nanometers for best sterilization effect.
10Wx2 20Wx1 30Wx1 30Wx1 20Wx2
Power Consumption 149W 155W 285W 285W 300W
External devices connected via power sockets are not included
Cabinet Structure Main Body: Electro-Galvanized steel with antimicrobial powder coating
Work Zone: 304 Stainless steel, an angled front, rounded work surface front edge
Side Windows: 5 mm UV resistant tempered glass
Power Supply AC220V ±10%, 50/60Hz, 1P
Standard Accessories LED lamp; UV lampx2; Waterproof socket×2 (only 1 for PCR-800); Shelves with IV bar
Optional Accessories Base stand(only PCR-800); Water tap, Gas tap, Height adjustable base stand
Net Weight 80kg(Without base stand), 130kg (With base stand) -
Gross Weight 115kg (Without base stand), 165kg (With base stand) 225kg 255kg 285kg 330kg
Shipping Size (W×D×H mm) 920x850x1190 1190x990x1325 1460x990x1325 1765x990x1325 2070x990x1325
Shipping Volume 0.93m3 1.56m3 1.92m3 2.3m3 2.7m3
 
All-in-One Design
FDA 510K & CLIA Waived 99% Accurate Results in as little as 1 minute 24 Month Shelf Life from Date of Manufacture Secure, seal and send to lab for confirmation Built in temperature strip Available to test up to 14 substances Adulterants available
 
 
  • Total Volume: 60mL.
  • Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
  • Made of premium PP material, it is durable for usage.
  • Some measurements can be used to not only use urine samples, it can also be used for other liquids.
Twenty Five (25) Test Strip per PackSkyla HB1 Clinical Chemistry Analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. HB1 provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. Only needs 200µl of blood (whole blood, serum or plasma is accepted.) and no sample preparation is required. All steps are designed automatically from checking the validity of reagent discs and cartridges to printing the results. Over 30 test parameters are allowed with fast analysis and results in 15 minutes. Internal Quality Control (IQC) with self-calibration of optical system, chemicals stability and interference alerts functions monitor and ensure the results with high accuracy. Available Test Panels
  • Renal Function - BUN, CREA eGFR
  • Liver Function - ALB, TP, ALP, ALT, AST, TBIL, DBIL, GGT, LDH A/G#, GLOB#, IBIL
  • Lipid Metabolism - TG, TC, HDL LDL#, VLDL
  • Pancreatitis Markers - AMY, LIPA
  • Carbohydrate Metabolism and Others - GLU , CPK, UA, LAC
  • Inflammatory Markers - CRP
  • Electrolyte - Na, K, Cl, Ca, PHOS, Mg, tCO2
SPECIFICATION Principle
  • Colormetric System : LEDs 340nm~940nm wavelength
Sample & Panel
  • Test Profiles : Panels
  • Measurement Time - Panel: up to 15 tests/ 15 min
  • Sample Type & Volume : 200 μl whole blood (PCV<60%), plasma, serum 
Device
  • User Interface : 5 inch color LCD touch screen
  • Internal Memory : Store up to 50,000 analysis results
  • Printer : Built in thermal printer or external USB printer (PCL 3GUI)
  • USB Socket : USB type A (Host) for external USB Printer, USB flash drive (FAT) or external barcode scanner
  • Data transmission to PC : RS232 serial port or RJ45 (LAN)
  • Dimensions : 233 (W) X 285 (D) X 300 (H) mm
  • Weight : 5.5 kg
Operating Condition
  • Temperature / Humidity : 10 to 32˚C / 5 to 90 %
 
Click Here To Download Catalogue
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Unlike traditional ESR methodologies that measure the aggregation of the red blood cells indirectly, the iSED measures it directly and expresses the values in mm/hr. Features:
  • Results in 20 Seconds

  • 100µL sample drawn directly from primary EDTA tube

  • Fully automated, walk-away operation

  • Random access

  • Positive patient identification via internal barcode reader

  • Compatible with pediatric tube

     
Technical Specifications: 
Principle of Measure: Photometrical
Results: “Printed mm/hr, Range from 1-130 mm/hr”
Sample Requirements: 500uL whole blood, collected in EDTA anti-coagulant tested 24 hours from venipuncture at room temperature or refrigerated.
Tube Requirements: 13 x 75 mm, pierceable capped tube
Quality Control: Barcoded Seditrol® QC
Barcode Reader: Internal
Printer: Internal
Interface Specifications: serial RS232 port for LIS connection
Weight: 14 kg
Dimensions (H x W x D): 36 x 27 x 34 (cm) /14.3 x 10.5 x13.4 (in)
Voltage: 100-240VAC
Frequency Range: 50-60 Hz
Power: 160W
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare