Phenol (antibacterial)

$0.00

Shipped From Abroad

Phenol is an antibacterial drug which comes in different forms. 

Please Note: Class 6.1 Dangerous Goods

Available in 100ml Glass Bottles

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF103356013099-27
Brands:: PharmAust

Description

Product Description

Phenol is an antibacterial drug which comes in different forms. The main
types are 80% aqueous (liquefied) phenol used topically in podiatry for
removal of ingrown toenails.

Please Note: Class 6.1 Dangerous Goods

Available in 100ml Glass Bottles

Reviews

There are no reviews yet.

Be the first to review “Phenol (antibacterial)”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsPhenol (antibacterial) removeTimesco Jumper Fingertip Pulse Oximeter removeFlowMir Disposable Turbine with Cardboard Mouthpiece removeSmith Medical Nasopharyngeal Airway (Portex) removeMale Urinal removeMaico TouchTymp MI36 Tympanometry remove
NamePhenol (antibacterial) removeTimesco Jumper Fingertip Pulse Oximeter removeFlowMir Disposable Turbine with Cardboard Mouthpiece removeSmith Medical Nasopharyngeal Airway (Portex) removeMale Urinal removeMaico TouchTymp MI36 Tympanometry remove
ImageFingertip Pulse OximeterFlowMir Disposable Turbine with Cardboard MouthpieceMaico TouchTymp MI36 Tympanometry and Amp
SKUSF103356013099-27SF1033560084-2SF1033560084-22SF1033560084-36SF1033560084-86SF1033560063-10
Rating
Price

$0.00

$17.00

$145.00

$0.00

$6.40

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad Phenol is an antibacterial drug which comes in different forms.  Please Note: Class 6.1 Dangerous Goods Available in 100ml Glass Bottles
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock Integrated with SPO2 probe and processing display module. Small in volume、light in weight and convenient in carrying. Operation of the product is simple ,low power consumption. SPO2 , PR and Ridisplay,. Pulse rate value display, bar graph display. Low-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage. Automatically power off function: when the device is under the state of measuring interface . it will automatically power off within 5 seconds if the finger falls out of probe. Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock Spirometry testing requires maximum accuracy and hygiene. Each Flowmir disposable turbine, which includes a cardboard mouthpiece, has been individually factory calibrated with a computerized system and it is packaged individually. FlowMIR® is an inexpensive alternative to a costly reusable flowmeter and replaces the need for an antibacterial filter Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock Smith Medical Nasopharyngeal Airway (Portex): Recommended for use in the semi-conscious or unconscious patient with an intact gag reflex. Not easily dislodged during transport and better tolerated than an Oropharyngeal Airway. Designed to be inserted into the nasal passageway to secure an open airway. Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped from Abroad TouchTymp MI 36 combines diagnostic middle ear analyzer and audiometry tests in one exceptional device. The full 10.4" touchscreen with its user-friendly interface guarantees a unique intuitive operation and allows to quickly change parameters. You can easily switch between the tests without reorganizing from one to another device and beneft from its small footprint when facing limited desk space. touchTymp MI 36 really improves your workflow every day. Delivery & Availability: Typically 10 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Product Description
Phenol is an antibacterial drug which comes in different forms. The main types are 80% aqueous (liquefied) phenol used topically in podiatry for removal of ingrown toenails. Please Note: Class 6.1 Dangerous Goods Available in 100ml Glass Bottles
Integrated with SPO2 probe and processing display module • Small in volume, light in weight, convenient in carrying • Simple operation, lower power consumption • OLED screen display • SPO2, PR, bar graph of pulse, plethysmogram, blood perfusion index, battery indication display • 4 directions display, 6 display models, large fonts display • Brightness control, Demo mode, Setup menu • Movement interference • Alarm function and adjustable alarm parameters • Can be connected to mobile phones through Bluetooth; can support Android and iOS client • Auto power-off when no signal after 10s • Powered by 2*AAA alkaline batteries Specification: • Size: 62 x 37 x 32mm • Peak wavelength range of the light emitted from the probe: red light 660nm±3; infrared light 905nm±5 • Maximum optical output power of the probe: 1.2mW for infrared light (905nm) • Bluetooth module: 4.0 (single-mode) • Working temperature: 5℃ to 40℃ (41°F to 104°F) • Relative humidity: 15% to 80%, non-condensing • Atmospheric pressure: 70kPa to 106kPa • Rated voltage: DC 3V Package included: • 1 x JUMPER JPD-500F Bluetooth Fingertip Pulse Oximeter • 2 x AAA Batteries • 1 x Carry Case • 1 x Lanyard • 1 x English User Manual
    • Comfortable Packaging
    • Singularly Tested and Packed
    • Always 100% accurate and hygienic
    • No Calibration required
    • No Sterilization required
    • No Antibacterial Filter required
    • No Cross Contamination
    • Not affected by Vapour Condensation
    • Not affected by Ambient conditions
    •  A full Spirometry session can be performed, including a Bronchial Challenge and POST Bronchodilator test. For each patient after the Spirometry test, both turbine and spirometer mouthpiece are thrown away
    • .
   
Smith Medical Nasopharyngeal Airway (Portex): Recommended for use in the semi-conscious or unconscious patient with an intact gag reflex. Not easily dislodged during transport and better tolerated than an Oropharyngeal Airway. Designed to be inserted into the nasal passageway to secure an open airway. Features:
  • Robertazzi style
  • Flared end prevents the device from becoming lost inside the patients nose
  • Soft no damage to nasal passage
  • Flexible resists collapse or kinking
  • Latex-free
  • 15mm fitting
 
 
TouchTymp MI 36 combines diagnostic middle ear analyzer and audiometry tests in one exceptional device. The full 10.4" touchscreen with its user-friendly interface guarantees a unique intuitive operation and allows to quickly change parameters. You can easily switch between the tests without reorganizing from one to another device and beneft from its small footprint when facing limited desk space. touchTymp MI 36 really improves your workflow every day. FEATURES AT A GLANCE
  • Combo device with small footprint
  • Customizable to suit individual needs
  • High resolution and quick screen transitions
  • Full touch-based interface for intuitive handling
  • Probe tone 226 Hz, 678 Hz, 800 Hz
  • Optional high-frequency probe tone 1 kHz
  • Acoustic reflex stimuli 500 Hz,1 kHz, 2 kHz, 4 kHz, BB, HP, LP (ipsilateral and contralateral)
  • Reflex Decay test (ipsilateral and contralateral)
  • ETF test for intact and perforated eardrums
  • Air conduction audiometry
  • Bone conduction audiometry
  • Built-in printer or data transfer to PC
  • Optional MAICO Sessions PC Software connectable with OtoAccess® or Noah patient database for easy data management
Comprehensive test protocols
  • Our touchTymp MI 36 provides comprehensive standard protocols for immediate operation of screening and diagnostic test processes: tympanometry with 226 Hz, tympanometry with automatic or fxed acoustic reflexes, reflex decay, Eustachian tube function testing (ETF) plus air conduction and bone conduction audiometry. The optional high-frequency probe tone of 1 kHz is ideal for providing reliable results when testing newborns
Stay focused on your patients
  • The unique touchTymp light bar on our shoulder box probe provides a real-time progression of the immittance test. The shoulder box can easily be clipped to your patient's top for controlled handling of the diagnostic probe. The light indicator shows you which ear is tested and the test result.
Printing made easy
  • Print test results instantly by using the touchTymp built-in printer. Place the shoulder box into its holder to automatically start printing. You can transfer the results to a PC to allow long term storage, full page printout and PDF creation for EMR integration.
Compatible to Sessions: Get ready for fast data transfer!
  • Use the touchTymp MI 36 with our intuitive data transfer solution Sessions, for easy management and visualization of your immittance measurements.
  TECHNICAL SPECIFICATION Tympanometry
  • Probe Frequency - 226 Hz ± 1 %, 85 dBSPL ± 1.5 dB, 678 Hz ± 1%, 72 dBSPL ± 1.5 dB, 800 Hz ± 1%, 70.5 dBSPL ± 1.5 dB
  • Optional High Frequency - 1 kHz ± 1%, 69 dBSPL ± 1.5 dB
  • Pressure Range - -600 to + 400 daPa
  • Accuracy of Pressure - ± 5 % or ± 10 daPa
  • Volume Range - 0.0 to 6.0 ml (compensated)
  • Compliance Range - 0.1 to 8.0 ml at 226 Hz, 0.1 to 15.0 mmho at 678, 800 and 1000 Hz
  • Accuracy of Volume - ± 5 % or 0.1 ml
  • Test Time Measurement - 3 - 5 seconds
Acoustic Reflexes
  • Test Frequencies - 0.5, 1, 2, 4 kHz ± 1 %
  • Test Noise - BB, LP, HP
  • Test Methods - Ipsilateral, contralateral
  • Level Ipsilateral - 70 to 105 dBHL
  • Level Contralateral - 70 to 120 dBHL
  • Level Setting - Automatic, fxed
  • Ipsilateral Reflex - Test With AGC
Reflex Decay
  • Standard - Probe frequency 226 Hz
  • Test Frequencies - 0.5, 1, 2, 4 kHz ± 1 %
  • Test Noise - BB, LP, HP
  • Level Ipsilateral - 70 to 105 dBHL
  • Level Contralateral - 70 to 120 dBHL
Eustachian Tube Function
  • Test Methods - Intact and perforated
  • Pressure Range - -600 to + 400 daPa
Audiometry
  • Test Signals - Sinus and warble tone, (pulsed and continuous)
  • Test Frequencies - 125, 250, 500, 750, 1000, 1500, 2000, 3000, 4000, 6000, 8000 Hz (125 Hz excluded
  • from bone conduction test frequencies)
  • Level Steps - 5 or 1 dB
  • Hearing Level Range AC - -10 to 120 dBHL
  • Hearing Level Range BC -  -10 to 80 dBHL
  • Masking Noise - Narrow band and white noise
Device General
  • Display - 10.4" Graphic LED-Display with resistive touchscreen
  • PC Interface - USB
  • Probe - Lightweight diagnostic Shoulder-Box with built-in control light and switch
  • Printer - Fast 4 inch thermal printer
  • Power Supply - Mains 100 to 240 V~ ± 10 %, 50 - 60 Hz ± 10 %
  • Dimensions / Weight - W 30 x D 34.5 x H 14.8 cm / 3.2 kg
  • Languages - English, German, Spanish, French, Polish, Turkish, Russian, Chinese
 
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare