| Description | Shipped From Abroad
Model : PH-30SP; PH-30FP; PH-30LP
The pocket pH tester's 3 points calibration ensures measurement accuracy for a variety of applications including agriculture, aquaculture, hydroponics and more! Now the best pocket pH tester for sale at cost price.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| In stock
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR).
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In Stock
HemoSmart GOLD offers a fast and easy way to measure hemoglobin level and is the first biosensor-based palm sized hemoglobin testing system in the world.The one of its kind strip-based testing method offers ease of use and portability and requires only 1μL of blood.
Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
- Microprocessor control.
- Digital display setting and actual temperature.
- Over temperature alarm, PID self-tuning.
- Digital display running timer.
- Stainless steel interior.
- Electricity leakage protection.
- With glass inner door, With hidden door locks.
- Mechanical overheat protection, cut off the heating sources.
- Automatic alarm after operation.
- Suitable for constant temperature tests.
- Suitable for bacteria cultivation, breeding, ferment.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped From Abroad
Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. |
| Content | Pocket pH Tester Features:
The measurement material is the main difference between the three pocket pH tester types.
Differences:
- PH-30SP: Round glass bulb pH electrode for measuring the pH of regular water samples.
- PH-30FP: Flat surface pH electrode for measuring semi-solid and gel samples.
- PH-30LP: Cone-shaped pH-sensitive membrane for piercing and measuring semi-solid samples such as soil, cheese, etc.
Pocket pH Tester Specifications:
| Model |
PH-30SP |
PH-30FP |
PH-30LP |
| pH |
| Range |
-1.00 to 15.00pH |
-1.00 to 15.00pH |
-1.00 to 15.00pH |
| Resolution |
0.01pH |
0.01pH |
0.01pH |
| Accuracy |
±0.01pH |
±0.01pH |
±0.01pH |
| Calibration Points |
1 to 3 points |
1 to 3 points |
1 to 3 points |
| pH Buffer Options |
USA(pH4.01/7.00/10.01) NIST(pH4.01/6.86/9.18) |
USA(pH4.01/7.00/10.01) NIST(pH4.01/6.86/9.18) |
USA(pH4.01/7.00/10.01) NIST(pH4.01/6.86/9.18) |
| Temperature |
| Range |
0 to 60°C/32 to 140°F |
0 to 60°C/32 to 140°F |
0 to 60°C/32 to 140°F |
| Resolution |
0.1°C/0.1°F |
0.1°C/0.1°F |
0.1°C/0.1°F |
| Accuracy |
±1°C/±1.8°F |
±1°C/±1.8°F |
±1°C/±1.8°F |
| Offset Calibration |
1 point |
1 point |
1 point |
| Calibration Range |
Reading ±10°C |
Reading ±10°C |
Reading ±10°C |
| General Specifications |
| Temperature Compensation |
0 to 60°C/32 to 140°F, automatic |
0 to 60°C/32 to 140°F, automatic |
0 to 60°C/32 to 140°F, automatic |
| Hold Function |
Manual or auto-endpoint |
Manual or auto-endpoint |
Manual or auto-endpoint |
| Auto-Power Off |
8 minutes after the last key is pressed |
8 minutes after the last key is pressed |
8 minutes after the last key is pressed |
| Display |
Dual-line LCD (21×21mm) |
Dual-line LCD (21×21mm) |
Dual-line LCD (21×21mm) |
| Power |
2×1.5V AAA batteries |
2×1.5V AAA batteries |
2×1.5V AAA batteries |
| Battery Life |
Approximately 200 hours of continuous use |
Approximately 200 hours of continuous use |
Approximately 200 hours of continuous use |
| Sizes(W×D×H)(mm) |
185(L)×40(Dia.) |
185(L)×40(Dia.) |
240(L)×40(Dia.) |
| Shipping Size (W×D×H)(mm) |
330x150x280 |
| N.W./G.W. (kg) |
0.1/1.5 |
| The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Unlike traditional ESR methodologies that measure the aggregation of the red blood cells indirectly, the iSED measures it directly and expresses the values in mm/hr.
Features:
-
-
100µL sample drawn directly from primary EDTA tube
-
Fully automated, walk-away operation
-
-
Positive patient identification via internal barcode reader
-
Compatible with pediatric tube
Technical Specifications:
| Principle of Measure: |
Photometrical |
| Results: |
“Printed mm/hr, Range from 1-130 mm/hr” |
| Sample Requirements: |
500uL whole blood, collected in EDTA anti-coagulant tested 24 hours from venipuncture at room temperature or refrigerated. |
| Tube Requirements: |
13 x 75 mm, pierceable capped tube |
| Quality Control: |
Barcoded Seditrol® QC |
| Barcode Reader: |
Internal |
| Printer: |
Internal |
| Interface Specifications: |
serial RS232 port for LIS connection |
| Weight: |
14 kg |
| Dimensions (H x W x D): |
36 x 27 x 34 (cm) /14.3 x 10.5 x13.4 (in) |
| Voltage: |
100-240VAC |
| Frequency Range: |
50-60 Hz |
| Power: |
160W |
Click Here To Download Catalogue | HemoSmart GOLD offers a fast and easy way to measure hemoglobin level and is the first biosensor-based palm sized hemoglobin testing system in the world.The one of its kind strip-based testing method offers ease of use and portability and requires only 1μL of blood.
Feature
- LCD Backlight
- Small Blood Sample
- Splash Proof
- Strip Ejection
- Hgb/Hct
- Fast Result
Specification
- Measurement Range: 0-24.0 g/dL
- Power Supply: 3A battery X 2
- Testing Time (seconds): 5 seconds
- Sample Volume (μL): 1 μL
- Memory Capabilities: 100 sets with date and time
- Operating Temperature (°C): 10 °C~40 °C
| Features:
- Microprocessor control.
- Digital display setting and actual temperature.
- Over temperature alarm, PID self-tuning.
- Digital display running timer.
- Stainless steel interior.
- Electricity leakage protection.
- With glass inner door, With hidden door locks.
- Mechanical overheat protection, cut off the heating sources.
- Automatic alarm after operation.
- Suitable for constant temperature tests.
- Suitable for bacteria cultivation, breeding, ferment.
Technical Specification:
Model: IB-9025A
Working size: 250x250x250mm/9.84x9.84x9.84inch
Power: 150W
Temperature range: Room temperature+5~65℃
Temperature resolution: 0.1℃
Temperature fluctuation: ±0.5℃
Timer: 0-9999min
Voltage: 110V 60Hz / 220V 50Hz
Dimension: 380x370x580mm/14.96x14.57x22.83inch
Size: 52cm*46cm*75cm / 20.5in*18.2in*29.6in
Gross Weight:42kg / 93lb
Net Weight: 23kg / 51lb
Warranty: 1 year | Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface.
Features:
- Parameters: Na+,K+,Cl-, iCa++ / Li
- It works on ISE principle
- Sample Type: Whole blood, Serum, Plasma, Urine
- Low reagent consumption
- Sample requirement is only 90ul
- 60 samples per hour
- Automatic two point calibration after 4hrs and one point calibration with each sample analysis
- Air bubble detection
- Track reagents consumption and provides alerts
- For low reagent volume
- Precision testing facility to get CV and SD
- Trilevel Quality Control with LJ plots of last 30days
- Low aspiration volume
- Fast sample processing
- Accurate and Precise results
Technical Specifications:
| Parameters |
Na+, K+, Cl– /Ca++ |
| Principle |
Ion Selective Electrode (ISE) |
| Sample Type |
Analyses whole blood, serum, plasma and urine |
| Sample Volume |
≤100 µL |
| Analysis Time |
≤60 seconds |
| Throughout |
≤60 samples per hour |
| Data Link |
Serial (RS232) |
| External Interface |
USB (Keyboard, Mouse) |
| Operating Condition |
10° C to 35° C, Relative Humidity up to 85% |
| Storage Condition |
Temp: 10° C to 40° C |
| Relative Humidity |
up to 85% non- condensing |
| Power Supply |
100 to 240 VAC ±10%, 50Hz |
| Dimensions |
395 x 260 x 375 mm |
| Weight |
7.5 kg |
|
The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes.
- User-friendly: the LabPad® INR is designed to be easy to use especially thanks to its 3D-shaped microcuvette that only requires a small drop of blood from a fingertip. Thanks to the color screen, both measurement steps and browsing the list of results are easy to visualize.
- Quick and reliable: the reliability of INR results is obtained by quality controls that are performed automatically before each measurement. In less than one minute, you can see if you are in your therapeutic range.
- Connected: the result obtained after performing the test can be transferred to healthcare professionals in charge of your treatment monitoring. This result is complementary to the pie charts and trend reports directly displayed on the LabPad® INR to help you monitoring your treatment
|
Reviews
There are no reviews yet.