Portable Auto Screener provides accurate and complete refractive information while screening for common vision problems including: Myopia, Hyperopia, Astigmatism, Anisometropia, and measuring Pupil Size and PD. It’s advanced Optical System needs only 1 Second to screen both eyes, and directly delivers the test results. SW-800 Handheld Auto Refractometer is Small and Lightweight, easy to carry and suitable for any indoors and outdoors vision acuity screening.
Specifications:
Operation mode | Bino/Mono |
Optometry | Automatic |
DS | Range: -7.50D~ 7.50D, Resolution: 0.25D/0.01D |
Accuracy: ±0.50D | |
DC | Range: 0.00D~3.00D, Resolution: 0.25D/0.01D, Accuracy: ±0.50D |
Axis | Range: 1°~180° Axis: Range 1°~180° |
Resolution: 1° Accuracy: ±5° | |
Pupil size | Range: 4.0mm~9.00mm |
Resolution | 0.1mm Accuracy: ±0.1mm |
Pupil distance | Range: 35mm~80mm |
Resolution: 1mm, Accuracy: ±1mm | |
Gaze | 0°~20° |
Measuring distance | 1m±5cm |
Time per measurement | ~1s |
Fixation target | Light flash, attractive sound |
Date interface | Wi-Fi, USB |
Battery | Rechargeable lithium batteries, 6 hours of duration, Replaceable |
Size | 180mmX130mmX110mm |
Display | 5 inch touch screen |
Weight | 0.8Kg |
Optional accessories | Camera tripods, printer, etc |
Quick Comparison
Settings | Portable Auto Vision Screener remove | Wash Hand Bowl with Stand remove | Instrument Tray remove | Syringe Needle Destroyer remove | Nihon Kohden Neurofax 1200 Electroencephalogram (EEG) Machine remove | Medical Safety Google remove | |||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | Portable Auto Vision Screener remove | Wash Hand Bowl with Stand remove | Instrument Tray remove | Syringe Needle Destroyer remove | Nihon Kohden Neurofax 1200 Electroencephalogram (EEG) Machine remove | Medical Safety Google remove | |||||||||||||||||||||||||||||||||||||||||||||||
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | |||||||||||||||||||||||||||||||||||||||||||||||
SKU | SF103356013062 | SF1033560084-246 | SF1033560084-199 | SF1033560084-206 | SF1033560020-2 | SF1033560084-196 | |||||||||||||||||||||||||||||||||||||||||||||||
Rating | |||||||||||||||||||||||||||||||||||||||||||||||||||||
Price | $3,740.00 | $36.00 | $6.90 | $157.00 |
| $1.99 | |||||||||||||||||||||||||||||||||||||||||||||||
Stock | |||||||||||||||||||||||||||||||||||||||||||||||||||||
Availability | |||||||||||||||||||||||||||||||||||||||||||||||||||||
Add to cart | |||||||||||||||||||||||||||||||||||||||||||||||||||||
Description | Shipped From Abroad
Portable Auto Screener provides accurate and complete refractive information while screening for common vision problems including: Myopia, Hyperopia, Astigmatism, Anisometropia, and measuring Pupil Size and PD.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| In stock
| In stock
| In stock
Needle destruction destroy the needle immediately following its use. Needle destruction are an absolute necessity in developing parts of the world to prevent the reuse of needles and the spread of bloodborne pathogens. They are NOT a good alternative, however, for hospital use in the developed parts of the world. Needle destruction are products that bend, cut, or destroy the needle. This are distinctly different from needle destroyer that send an arc of electricity to vaporize and melt the needle.
| Shipped from abroad The high-acuity Neurofax EEG system is extremely intuitive. Its user-friendly software features a wide range of functions including record, playback, and quantitative data analysis. As a standard examination in neurology, electroencephalography is used in many scenarios – from routine diagnostics to critically ill patients, or neuromonitoring in the ICU. The Neurofax EEG system is built to cover all aspects of diagnostics, delivering innovative functionality, high signal quality, and durability to ensure efficiency – all while remaining simple to use. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
| |||||||||||||||||||||||||||||||||||||||||||||||
Content | Portable Auto Screener provides accurate and complete refractive information while screening for common vision problems including: Myopia, Hyperopia, Astigmatism, Anisometropia, and measuring Pupil Size and PD. It’s advanced Optical System needs only 1 Second to screen both eyes, and directly delivers the test results. SW-800 Handheld Auto Refractometer is Small and Lightweight, easy to carry and suitable for any indoors and outdoors vision acuity screening.
Specifications:
|
|
| Needle destruction destroys the needle immediately following its use. Needle destruction are an absolute necessity in developing parts of the world to prevent the reuse of needles and the spread of bloodborne pathogens. They are NOT a good alternative, however, for hospital use in the developed parts of the world. Needle destruction are products that bend, cut, or destroy the needle. This are distinctly different from needle destroyer that send an arc of electricity to vaporize and melt the needle.
Features:
| The high-acuity Neurofax EEG system is extremely intuitive. Its user-friendly software features a wide range of functions including record, playback, and quantitative data analysis. As a standard examination in neurology, electroencephalography is used in many scenarios – from routine diagnostics to critically ill patients, or neuromonitoring in the ICU. The Neurofax EEG system is built to cover all aspects of diagnostics, delivering innovative functionality, high signal quality, and durability to ensure efficiency – all while remaining simple to use.
Features:
Click Here To Download Catalogue | ||||||||||||||||||||||||||||||||||||||||||||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | |||||||||||||||||||||||||||||||||||||||||||||||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | |||||||||||||||||||||||||||||||||||||||||||||||
Additional information |
Reviews
There are no reviews yet.