Description | Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Features:
- True Double conversion Technology
- DSP digital control technology enable UPS more stable performance.
- Three Level inverter control technology
- Large screen LCD display
- N+X Parallel Redundancy function (3 units parallel)
- EPO emergency stop function
- Smart expansion Slots (optional)
- Support Generator
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Features:
- Valve sealed design, no free electrolyte, Maintenance -free
- Designed floating service life:15 years @ 25 °C/68 °F.
- Wide operating temperature range from -15°C to 35°C
- Nanometer gel electrolytes eliminate the acid stratification and prolong cycle life
- Low self-discharge rate: ≤3%/month.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Features:
- Pure sine wave output
- DSP digital control
- Boost and buck AVR for voltage stabilization
- Cold start function
- Intelligent battery management
- Short circuit and overload protection
- Off-mode charging
- Offering LED and LCD panels for selection
- Optional USB/RS232/RJ45/SNMP communication port
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Features:
- DSP digital control technology enables UPS more stable performance-+
- Environment friendly eco-designed
- Active input power factor correction
- Wide range of input voltage and frequency
- Zero power switch delay
- Adaptive Load Management.
- Sufficient Expansion Slots: USB ,RS485 ,AS400 SNMP cards(Optional)
- Support the generator
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
f |
Content | Features:
- Rated Power: 1000W
- Rated Capacity: 932.4wh
- Standard Capacity: 3.7V/252000mah
- Overload Protecion: 1050+40W
- AC Output: AC 110V+10%/60HZ 230V+10%/50HZ
- Output Wave: Pure sine wave
- USB Output: QC 18W*2
- Type-c Output: PD 60W*2
- Cigarret Lighter Output: 14V/8A
- DC5525 Output: 14V/8A
- Wireless Charging: 15W
- Charging Input: 12-26 V/150W Max
- WorkingTemperature: -10-40 °C
- Weight(Net Weight): 8. 2kg
- Weight(With Accessories): 10.2kg
- Dimension: 345*227*203mm
Applications:
- Mammogram
- Ultrasound Equipments
- Radiology rooms
| Features:
- True Double conversion Technology
- DSP digital control technology enable UPS more stable performance.
- Three Level inverter control technology
- Large screen LCD display
- N+X Parallel Redundancy function (3 units parallel)
- EPO emergency stop function
- Smart expansion Slots (optional)
- Support Generator
Applications:
- Mammogram
- Ultrasound Equipments
- Radiology rooms
Technical Specifications
Model |
VT6K |
VT6KL |
VT10K |
VT10KL |
31VT10KL |
31VT15KL |
31VT20KL |
Capacity |
6KVA/5400W |
10KVA/9000W |
15KVA/13.5KW |
20KVA/18KW |
Input |
Nominal Voltage |
220/230/240Vac |
380/400/415Vac |
Voltage Range |
120-275VAC(1P2W+G) |
207-475VAC(3P4W+G) |
Current |
31A (max) |
50A(max) |
50A (max) |
75A(max) |
100A(max) |
Frequency |
46-54Hz Synchronous mains power; 50Hz( Frequency Range 40-46Hz ~54-60Hz);50Hz(Battery mode) |
Power Factor |
≥0.99· |
Output |
Voltage |
220/230/240±2%Vac (1P2W+G) |
Frequency |
50/60 Hz(adjustable)
50/60Hz± 5% (Line mode)
50/60Hz ± 0.05Hz ( Battery mode) |
Current |
27.3A |
45A |
68A |
91A |
Power Factor |
0.9 |
Waveform |
Pure Sine Wave |
Waveform Distortion |
Line load <2% |
Line load <3% |
Back-up Time |
Full Load |
≥7′ |
Depends on external batteries bank’s Capacity |
≥5′ |
Depends on external batteries bank’s Capacity |
Half Load |
≥20 |
≥13′ |
Battery Nominal Voltage |
192/240Vdc |
Transfer Time |
0ms |
Overload Capacity |
105%±5%< Load<125%±5% :1 min transfer to bypass
125% ±5% < Load<135 % ±5 % :30s transfer to bypass
Load > 135 % ± 5 %: 300s transfer to bypass |
Communication |
SNMP,RS-232,USB+lntelligent Slot |
Operating Environment |
Temperature |
0°C~40°C |
Humidity |
15%~90% |
Dimension |
Width (mm) |
260 |
260 |
260 |
260 |
260 |
Depth (mm) |
560 |
533 |
560 |
533 |
560 |
Height (mm) |
717 |
501 |
717 |
501 |
717 |
Net Weight(Kg) |
55 |
12.2 |
62 |
21 |
23 |
32 |
33 |
| Features:
- Valve sealed design, no free electrolyte, Maintenance -free
- Designed floating service life:15 years @ 25 °C/68 °F.
- Wide operating temperature range from -15°C to 35°C
- Nanometer gel electrolytes eliminate the acid stratification and prolong cycle life
- Low self-discharge rate: ≤3%/month.
Application
- UPS Systems
- Portable Equipment
- Renewable Energy Systems
- Electric Utilities
- Outdoor control Equipment
- Railroad Utilities
- Telecom Systems
Technical Specifications
Model |
Nominal Voltage |
Capacity |
Dimension LXWXH (mm) |
Total Height
(mm) |
Weight (KG/IBS) |
Terminal |
VG12-33 |
12V |
33AH |
195 |
130 |
167 |
167 |
10 |
22.05 |
M6 |
VG12-35 |
12V |
35AH |
195 |
130 |
167 |
167 |
11.5 |
25.35 |
M6 |
VG12-38 |
12V |
38AH |
197 |
165 |
172 |
172 |
12.5 |
27.56 |
M6 |
VG12-40 |
12V |
40AH |
197 |
165 |
172 |
172 |
13.2 |
29.1 |
M6 |
VG12-45 |
12V |
45AH |
197 |
165 |
172 |
172 |
15 |
33.07 |
M6 |
VG12-50 |
12V |
50AH |
229 |
138 |
205 |
208 |
15.5 |
34.17 |
M6 |
VG12-55 |
12V |
55AH |
229 |
138 |
205 |
208 |
16.5 |
36.38 |
M6 |
VG12-65 |
12V |
65AH |
350 |
166 |
175 |
175 |
21 |
46.3 |
M8 |
VG12-70 |
12V |
70AH |
260 |
168 |
208 |
211 |
21.8 |
48.06 |
M8 |
VG12-80 |
12V |
80AH |
260 |
168 |
208 |
211 |
24 |
52.91 |
M8 |
VG12-90 |
12V |
90AH |
330 |
171 |
216 |
219 |
27 |
59.52 |
M8 |
VG12-100 |
12V |
100AH |
330 |
171 |
216 |
219 |
29.5 |
65.04 |
M8 |
VG12-120 |
12V |
120AH |
407 |
173 |
237 |
237 |
35 |
77.16 |
M8 |
VG12-150 |
12V |
150AH |
484 |
170 |
241 |
241 |
45 |
99.21 |
M8 |
VG12-200 |
12V |
200AH |
522 |
240 |
219 |
222 |
61.5 |
135.58 |
M8 |
VG12-250 |
12V |
250AH |
520 |
268 |
220 |
223 |
71 |
156.53 |
M8 |
| Features:
- Pure sine wave output
- DSP digital control
- Boost and buck AVR for voltage stabilization
- Cold start function
- Intelligent battery management
- Short circuit and overload protection
- Off-mode charging
- Offering LED and LCD panels for selection
- Optional USB/RS232/RJ45/SNMP communication port
Technical Specifications
MODEL |
UPS-AP1K ( L ) |
UPS-AP2K ( L ) |
UPS-AP3K ( L ) |
Capacity |
1000VA/700W |
2000VA/1400W |
3000VA/2100W |
INPUT |
Voltage range |
145~275VAC±5V |
Frequency range |
50Hz-60Hz |
OUTPUT |
Output voltage |
220VAC |
AC voltage range |
±10% |
Frequency range(batt.mode) |
50Hz ± 0.25Hz or 60Hz ± 0.3Hz |
Overload |
105%-110%: UPS beep alarm, do not shut down. |
110%-130%: auto shut down after 30 seconds |
> 130%: auto shut down immediately |
Transfer time |
<typical 4ms |
Waveform(batt.mode) |
Pure sine wave |
BATTERY |
Standard model |
Battery type |
12V7Ah |
Numbers |
2 |
4 |
6 |
Charging current(Max.) |
Assume: 1A± 10%; Max: 1A or 2A for option |
Charging voltage |
27.3VDC±1% |
54.7VDC±1% |
82.0VDC±1% |
Long-run model |
Battery type |
12V, AH depending on applicant |
Numbers |
3 |
6 |
8 |
Charging current(Max.) |
> 5A |
Charging voltage |
27.4VDC±1% |
82.1VDC±1% |
109.4VDC±1% |
PHYSICAL |
Standard model |
Dimension, LxWxH(mm) |
360x147x220 |
440x192x340 |
440x192x340 |
Net weight(kgs) |
11.9 |
22 |
27.9 |
Long-run model |
Dimension, LxWxH(mm) |
360x147x220 |
440x192x340 |
440x192x340 |
Net weight(kgs) |
8.5 |
16 |
18.2 |
ENVIRONMENT |
Humidity |
20-90%RH @0-40°C (non-condensing) |
Noise level |
Less than 55dBA@1 Meter |
MANAGEMENT |
Smart RS-232 |
Support windows 2000/2003/XP/Vista/2008, Windows7/8, Linux, Unix, and MAC |
Optional SNMP |
Power management from SNMP Management and web browser |
| Features:
- DSP digital control technology enables UPS more stable performance-+
- Environment friendly eco-designed
- Active input power factor correction
- Wide range of input voltage and frequency
- Zero power switch delay
- Adaptive Load Management.
- Sufficient Expansion Slots: USB ,RS485 ,AS400 SNMP cards(Optional)
- Support the generator
Specifications:
Model |
33VT 10K |
33VT 10KL |
33VT 20K |
33VT 20KL |
33VT 30KL |
33VT 40KL |
Capacity |
10KVA/9000W |
20KVA/18KW |
30KVA/27KW |
40KVA/36KW |
Input |
Nominal Voltage |
380/400/415Vac |
Voltage Range |
207-475VAC(3P4W+G) |
Current |
14A |
28A |
42A |
67A |
Frequency |
40-70Hz (Adjustable) |
Power Factor |
≥0.99 |
Output |
Voltage |
380VAC 1±1% (3P4W+G) |
Frequency |
46-54Hz Synchronous mains power; 50Hz( Frequency Range 40-46Hz -54-60Hz);50Hz(Battery mode) |
Current |
15A |
30A |
45A |
61A |
Power Factor |
0.9 |
Crest Factor |
3:1 |
THD |
Line load <3% |
Chrage Current |
5.5A |
1A |
7.5A |
1A |
5.5A |
Battery Nominal Voltage |
192VDC |
±192VDC |
Transfer Time |
0ms |
Overload Capacity |
105%±5%< Load<125%±5% :1 min transfer to bypass
125% ±5% < Load<135 % ±5 % :30s transfer to bypass
Load > 135 % ± 5 %: 300s transfer to bypass |
Communication |
SNMP,RS-232,USB+lntelligent Slot |
Operating Environment |
Temperature |
0°C~40°C |
Humidity |
20%~95% |
Dimension |
Width (mm) |
260 |
260 |
260 |
260 |
Depth (mm) |
560 |
533 |
710 |
560 |
Height (mm) |
717 |
501 |
717 |
717 |
Net Weight(Kg) |
26 |
72 |
57.5 |
98 |
58.5 |
62 |
| Features:
Nomimal voltage: 12V
Rated Capacity: 5Ah ~ 250Ah
Operating temperature range: -15 ~ 45 ℃
The design life is 5 years
Using new special process sheet formula to improve the utilization of active material
Using high quality superfine glass fiberliquid-suction battery technology to exceed 99% gas recombination rate
High-strength ABS plastic battery slot and cover with features of compact structure, corrosion resistant, impact resistance and
anti-vibration and so on
Small internal impedance, excellent performance when high current discharge
Low self-discharge, wide operating temperature range
Using multiple sealing technologies to ensure no leakage, no acid mist escaping to keep safe and reliable
Using strict production process, unit voltage balance is strong
Free maintenance, without adding water rehydration
Technical Specifications
Model |
Nominal Voltage |
Capacity |
Dimension LXWXH (mm) |
Total Height
(mm) |
Weight (KG) |
Terminal |
VL12-24 |
12 |
24 |
166 |
175 |
125 |
125 |
8 |
M6 |
VL12-28 |
12 |
28 |
166 |
175 |
125 |
125 |
9 |
M6 |
VL12-33 |
12 |
33 |
196 |
130 |
163 |
180 |
10 |
M6 |
VL12-35 |
12 |
35 |
197 |
130 |
163 |
180 |
10.5 |
M6 |
VL12-40 |
12 |
40 |
197 |
166 |
171 |
171 |
13.5 |
M6 |
VL12-44 |
12 |
44 |
196 |
166 |
171 |
171 |
13.5 |
M6 |
VL12-55 |
12 |
55 |
230 |
138 |
211 |
229 |
17.2 |
M6 |
VL12-65 |
12 |
65 |
350 |
166 |
179 |
179 |
22 |
M6 |
VL12-70 |
12 |
70 |
260 |
169 |
211 |
229 |
23 |
M8 |
VL12-80 |
12 |
80 |
260 |
169 |
211 |
229 |
24 |
M8 |
VL12-90 |
12 |
90 |
307 |
169 |
211 |
234 |
28 |
M8 |
VL12-100 |
12 |
100 |
331 |
173 |
213 |
233 |
32 |
M8 |
VL12-120 |
12 |
120 |
407 |
174 |
209 |
233 |
3, 8 |
M8 |
VL12-130 |
12 |
134 |
341 |
173 |
283 |
287 |
41 |
M8 |
VL12-150 |
12 |
150 |
484 |
171 |
241 |
241 |
46 |
M8 |
VL12-160 |
12 |
160 |
534 |
209 |
216 |
237 |
52 |
M8 |
VL12-180 |
12 |
180 |
530 |
209 |
216 |
237 |
56 |
M8 |
VL12-200 |
12 |
200 |
522 |
240 |
220 |
244 |
64 |
M8 |
VL12-230 |
12 |
230 |
520 |
268 |
220 |
240 |
72.5 |
M8 |
VL12-250 |
12 |
250 |
520 |
268 |
220 |
249 |
76 |