Portable Stainless Steel Autoclave Sterilizer
Ask for Price$0.00
In Stock
- Can be set as required sterilization temperature, working tem. range:room tem.:+5~126 Degree.
- Can ge set as required sterilization time of heat preservation, setting range:1~99min.
- Having a low water to stop heating function.
- This product uses the high quality stainless steel SUS304. Having to work under normal conditions adequate safety strength.
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
Features:
- Can be set as required sterilization temperature, working tem. range:room tem.:+5~126 Degree.
- Can ge set as required sterilization time of heat preservation, setting range:1~99min.
- Having a low water to stop heating function.
- This product uses the high quality stainless steel SUS304. Having to work under normal conditions adequate safety strength.
Technical Specifications:
Model No.: | YX280A |
Sterilizing volume | 18L |
Working pressure | 0.14-0.16Mpa |
Working temperature | 126ºC |
Max. safety pressure | 0.165Mpa |
Characteristics | Electric heated |
Quick Comparison
Portable Stainless Steel Autoclave Sterilizer remove | Plastic Urine Container Per Pack remove | AB Diagnostic HCV Ab Elisa Kit remove | Plastic Test Tube Rack remove | 18Ltrs Bucket Autoclave remove | 8 Bucket Centrifuge remove | |||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | Portable Stainless Steel Autoclave Sterilizer remove | Plastic Urine Container Per Pack remove | AB Diagnostic HCV Ab Elisa Kit remove | Plastic Test Tube Rack remove | 18Ltrs Bucket Autoclave remove | 8 Bucket Centrifuge remove | ||||||||||||||||||||||||||||||||||||||
Image | ||||||||||||||||||||||||||||||||||||||||||||
SKU | SF1033560084-4 | SF1033560084-106 | SF1033560084-211 | SF1033560084-174 | SF1033560084-7 | SF1033560084-114 | ||||||||||||||||||||||||||||||||||||||
Rating | ||||||||||||||||||||||||||||||||||||||||||||
Price | Ask for Price | $8.20 | Ask for Price | $3.00 | Ask for Price | $72.50 | ||||||||||||||||||||||||||||||||||||||
Stock | ||||||||||||||||||||||||||||||||||||||||||||
Availability | ||||||||||||||||||||||||||||||||||||||||||||
Add to cart | ||||||||||||||||||||||||||||||||||||||||||||
Description | In Stock
| In stock
| In stock
Abia HCV Ab is an enzyme immunoassay for the qualitative detection of antibodies to hepatitis C virus (HCV) in human serum or plasma.
| In stock
| In Stock
| In stock
| ||||||||||||||||||||||||||||||||||||||
Content | Features:
|
| Abia HCV Ab is an enzyme immunoassay for the qualitative detection of antibodies to hepatitis C virus (HCV) in human serum or plasma.
Abia HCV Ab (D.K.067.01.3):
Abia HCV Ab (D.K.067.05.3):
|
| Features:
| 800-1 electric centrifuge is widely used in hospitals, chemical and Biological Chemistry Laboratory for serum, plasma, immune qualitative analysis experiment. Has beautiful shape, large capacity, small volume, complete function. Its performance is stable, the speed is adjustable and can automatically adjust the balance, low temperature, high efficiency and wide applicability and advantages.
Technical Specifications:
Click Here To Download Catalogue | ||||||||||||||||||||||||||||||||||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||||||||||||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||||||||||||
Additional information |
Reviews
There are no reviews yet.