New

PSU-100 Electrosurgical Unit

$0.00

Shipped From Abroad

The PSU-100 Electrosurgical Unit is a compact, safe, and efficient device offering monopolar and bipolar modes. With advanced safety systems, precise power control, and 500 kHz technology, it ensures accuracy and reliability in surgical cutting and coagulation procedures.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Brands:: Promed-Tech

Description

The PSU-100 Electrosurgical Unit is designed for safe and reliable surgical performance, supporting monopolar cut, blend, coagulation, and bipolar coagulation modes. Operating at 500 kHz, it provides a stable high-frequency output with adjustable power up to 100W. Its return electrode monitoring (REM) system enhances patient safety by preventing burns, while automatic power termination prevents misoperation. Compact and lightweight, the PSU-100 ensures precision, minimal tissue sticking, and reduced carbonization, making it ideal for general surgery, gynecology, and other clinical applications.

Features
  • Excellent monopolar cautery machine with smart & light design.
  • Max 4 work modes: Pure/Blend, Standard/Spray.
  • Return electrode monitoring system to avoid any burns and damage to the patient.
  • Clear working modes indication and easy power control.
  • Minimal sticking & carbonization, reducing the surgery damage.
  • Auto-terminate the power output after 5s to avoid misoperation.
  • Different & Adjustable operation sounds in case of misoperation.
  • High-frequency 500 kHz stable output
  • Monopolar and bipolar modes for diverse surgical needs
  • Power adjustment in fine 5W increments
Technical Specifications
Work Mode Frequency Rated Power Increment Form of HF Current
Monopolar Cut 500 kHz 0–100W / 400 Ω 5W Sine Wave
Monopolar Blend 500 kHz 0–70W / 400 Ω 5W Modulated Sine Wave
Monopolar Coag 500 kHz 0–70W / 400 Ω 5W Modulated Sine Wave
Bipolar Coag 500 kHz 0–50W / 400 Ω 5W Modulated Sine Wave

Reviews

There are no reviews yet.

Be the first to review “PSU-100 Electrosurgical Unit”

Your email address will not be published. Required fields are marked *

Quick Comparison

PSU-100 Electrosurgical Unit removeOBS-100A Monopolar Electrosurgical Unit removeOBS-100C(I) Intelligent Electrosurgical Unit removeBipolar Irrigated Coagulator removeOBS-100B Cold Bipolar Coagulator removeOBS-50 High Frequency Coagulator remove
NamePSU-100 Electrosurgical Unit removeOBS-100A Monopolar Electrosurgical Unit removeOBS-100C(I) Intelligent Electrosurgical Unit removeBipolar Irrigated Coagulator removeOBS-100B Cold Bipolar Coagulator removeOBS-50 High Frequency Coagulator remove
Image
SKUSF1033560130165-7SF1033560130165-2SF1033560130165-12SF1033560130165-8SF1033560130165-3
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad

The PSU-100 Electrosurgical Unit is a compact, safe, and efficient device offering monopolar and bipolar modes. With advanced safety systems, precise power control, and 500 kHz technology, it ensures accuracy and reliability in surgical cutting and coagulation procedures.

Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad Portable in size, available in both monopolar and bipolar modes, convenient handle power control and memory function, suitable for microsurgery, gynecology, and arthroscopy.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad The OBS-100B Cold Bipolar Coagulator is a precision electrosurgical device designed for delicate surgeries. It ensures minimal tissue irritation, offers a non-stick effect, and operates without sparking, making it ideal for microsurgical applications like neurosurgery and ophthalmology.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad This unit is widely used in many different sectors including plastic surgery, dermatology, ENT, Ophthalmology, somatology, gynecology, proctology, and urology.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content

The PSU-100 Electrosurgical Unit is designed for safe and reliable surgical performance, supporting monopolar cut, blend, coagulation, and bipolar coagulation modes. Operating at 500 kHz, it provides a stable high-frequency output with adjustable power up to 100W. Its return electrode monitoring (REM) system enhances patient safety by preventing burns, while automatic power termination prevents misoperation. Compact and lightweight, the PSU-100 ensures precision, minimal tissue sticking, and reduced carbonization, making it ideal for general surgery, gynecology, and other clinical applications.

Features
  • Excellent monopolar cautery machine with smart & light design.
  • Max 4 work modes: Pure/Blend, Standard/Spray.
  • Return electrode monitoring system to avoid any burns and damage to the patient.
  • Clear working modes indication and easy power control.
  • Minimal sticking & carbonization, reducing the surgery damage.
  • Auto-terminate the power output after 5s to avoid misoperation.
  • Different & Adjustable operation sounds in case of misoperation.
  • High-frequency 500 kHz stable output
  • Monopolar and bipolar modes for diverse surgical needs
  • Power adjustment in fine 5W increments
Technical Specifications
Work Mode Frequency Rated Power Increment Form of HF Current
Monopolar Cut 500 kHz 0–100W / 400 Ω 5W Sine Wave
Monopolar Blend 500 kHz 0–70W / 400 Ω 5W Modulated Sine Wave
Monopolar Coag 500 kHz 0–70W / 400 Ω 5W Modulated Sine Wave
Bipolar Coag 500 kHz 0–50W / 400 Ω 5W Modulated Sine Wave
 
Features

1. Portable and  affordable

2. Suitable for general surgery and veterinary
Technical Details
Environmental temperature range: 5°C~ 40°C
Relative moisture range: ≤80%
Atmosphere pressure range: 86.0 Kpa ~ 106.0 Kpa
Working modes:
Pure cut: 5w ~ 100w (Load:300Ω)
Blend cut: 5w ~ 50w (Load:300Ω)
Forced coagulation: 5w ~ 80w (Load:500Ω)
Soft coagulation: 5w ~ 50w (Load:500Ω)
Technology data:
Voltage: 230V±10V, 50Hz
Working frequency: 330KHz ~ 460KHz
Leakage currents to ground: Less than 0.5mA
Leakage currents to patient: Less than 0.01mA
 
Key Features
OBS-100 Electrosurgical Generator with state-of-art technology offers superb performance on the electro-surgery, and shows remarkable safety, reliability and convenience. 1. Two levels of coagulation: pinpoint coagulation and fulguration Pinpoint coagulation provides precise control of bleeding in localized areas. Fulguration provides greater control of bleeding in highly vascular over-surface areas. 2. Presets The unit incorporates as many as ten user-defined presets for easy recall of frequency and settings. 3. Isolated RF output for Cut, Blend, and Coag modes This minimizes the potential of alternate site burns. 4. Ground Referenced RF output for Fulguration modes 5. Self-diagnostics These diagnostics continually monitor the unit to ensure proper performance. If the diagnostics is unsuccessful, the warning tones can be heard.
Technical parameters:
Environmental temperature range: 5°C~ 40°C
Relative moisture range: ≤80%
Atmosphere pressure range: 86.0 ~ 106.0 Kpa
 Working modes:
Pure cut: 1w ~ 60w (Load 500Ω)
Blend: 1w ~ 60w (Load 800Ω)
Coagulation: 1w ~ 60w (Load 1000Ω)
Fulguration: 0.1w ~ 35w (Load 1000Ω)
Bipolar: 1w ~ 30w (Load 200Ω)
Technology data:
Voltage: 220V±10V, 50Hz ±1Hz
Working frequency: 357 KHz ~ 575 KHz
Leakage currents to ground: Less than 0.5mA
Leakage currents to patient: Less than 0.01mA
Display Setting: Fulguration a.      0-10 range: 0.1watt increments b.      10-35range: 1.0 watt increments Cut, Blend, Coagulation, and Bipolar 1.0-watt increments Power supply:220V±10%,50±1%Hz. Transportation and storage a)        Ambient temperature range: -40°C~55°C; b)        Relative moisture range: ≤95%; c)        Atmosphere pressure range: 500hPa~1060hPa. Accessories Included: Electrosurgical Pencil, disposable                           2pcs Bipolar Forceps with cable, reusable                      1pc Disposable Electrosurgical Pad                               2pcs Cable for Electrosurgical Pad, reusable                  1pc Footswitch                                                              1pc Power cord                                                             1pc Manual                                                                    1pc
Features

1. LED light positioned between the electrodes enhances the vision during surgery.

2. Massive area hemostasis can be performed in a short time in order to reduce intraoperative blood loss 3. Saline line and dripping device are equipped in an attempt to contain the heat on the treated tissue and avoid thermal tissue damage
Indications for Use
  • Ensure that both electrodes are in contact with the tissue to be treated. Activation and saline flow occur simultaneously.
  • Ensure that saline is flowing at the time of activation
  • These devices should never be used when:
  • There is visible evidence of damage to the exterior of the device such as cracked or damaged plastic or connector damage.
  • These devices fail the inspection described herein.
  • In the presence of flammable gases, flammable prep solutions or drapes. Oxidizing. Gases such as Nitrous Oxide (N2O), or in oxygen-riched environments.
  • Do not use monopolar electrosurgery on small appendages, as in circumcision or finger surgery.
 
Features
  • Low voltage output: Ensures minimal irritation to neuromuscular tissues.
  • Sparkless operation: Reduces tissue sticking.
  • Superb non-stick effect: Enhances surgical precision.
  • Suitable for microsurgery: Ideal for neurosurgery, ophthalmology, gynecology, and plastic surgery
 
  The OBS-50 is a market leader across the world due to its ease of use, high security, power on self test, full-range monitoring, remote control and precise output.
  • Power output can be controlled by the easy to use power adjustment button on the electrosurgical hand pencil which can shorten the operation time.
  • With the inbuilt memory function on the device, you can set the required function parameters then power off the unit, next time the unit is powered on, the unit the last set parameter will be displayed.
  • Output power of between 10 and 30 watts or less can be adjusted up and down by 0.1-watt increments, which is suitable for various delicate procedures.
  • It can be used with disposable dispersive electrode
 What's in the box?
  • x1 OBS-50 High-Frequency Electric Coagulator Unit
  • x1 Reusable power control electrosurgical pencil
  • x10 Non-Sterile Single-Use Short Sharp Tips
  • x10 Non-Sterile Single-Use Short Blunt Tips
  • x1 Power cord
  • x1 Instruction manual
Multiple Applications to meet your different clinic demands
Desiccation 
  • Monopolar output mode without using the dispersive electrode
  • Contact or insert into the tissue with the electrode
  • The unit produces a high-frequency current, which runs through the patient via the electrode and then returns to the unit through grounding.
  • High-frequency current vaporises the liquid inside the tissue cell therefore causing denaturation on the protein
Fulguration
  • Another monopoly output mode without using a dispersive electrode
  • Holding the electrode above the lesions rather than contact directly, will release an electric arc to the tissue.
  • Range of action in this mode is limited to the surface where the arc contacts the tissue
Coagulation
  • Suitable for hemostasis and shrinkage of tissue
  • Used in control of hemostasis
  • Suitable for more difficult cutting procedures for good hemostasis
Monopolar coagulation
  • Monopolar output mode using the dispersive electrode
  • Under this mode, the high-frequency current that is produced from the unit flows through the patient and then returns to the unit via a dispersive electrode
  • The dispense electrode can draw more high-frequency current to the electrode, making the tip of electrode produce a more powerful desiccation to the tissue.
Bipolar Coagulation
  • An Output mode in which the high-frequency current circulates between two nearby electrodes (bipolar forceps), without using the dispersive electrode.
  • In contrast to the effect of monopolar coagulation, since the high-frequency current is only circulated separately in the forceps, the bipolar coagulation effect acts only on the tissue surface, causing minimal damage to the tissue.
Standard Accessories (Can be purchased Separately)
  • Single foot switch
  • Reusable power control electrosurgical pencil
  • Reusable dispersive electrode (Patient Plate) & Cable
  • Reusable bipolar forceps & cable
  • Reusable Connecting Cable (for disposable dispersive electrode)
  • Disposable dispersive electrodes
  • Wall mounting Plate
Output Mode  Monopolar coagulation: (30W, load:1000Ω) Bipolar coagulation: (30W, load:200Ω) Technical parameters
Ambient Temperature  10°C - 40°C
RH Range ≤80%
atmospheric pressure range 50.0kPa-106.0kPa
Power supply 220/110V,50/60Hz
operating Frequency 550kHz+10%
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare