Rosenbaum Eye Chart

$0.00

Shipped From Abroad

The Rosenbaum Pocket Vision Screening Card utilizing PV Numbers™ with Acuity Testing on Side 1 and Continuous Text Reading on Side 2. Includes Jaeger and Snellen notations, pupil gauge, and rulers.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130172-50

Description

The Rosenbaum Pocket Vision Screening Card utilizing PV Numbers™ provides 20/800 distance equivalent testing when held at a distance of 16 inches (40 cm). This card fits easily in a pocket for quick, convenient visual acuity screening. This Pocket Eye Chart is printed on durable plastic, and includes matching 20/200 Jaeger notation. Side 1 also includes pupil diameter gauge.

Side 2 features continuous text format. This format helps to simulate everyday activities such as reading. This simulation leads to better testing of the patient and helps identify near vision problems that interfere with normal activities. Side 2 includes both metric and standard rulers.

Reviews

There are no reviews yet.

Be the first to review “Rosenbaum Eye Chart”

Your email address will not be published. Required fields are marked *

Quick Comparison

Rosenbaum Eye Chart removePortable Rebound Tonometer removeAutomatic Computer Goldmann (Visual Field Analyzer) removeOphthalmic AB Scan Machine removeSlit Lamp removeManual lensmeter remove
NameRosenbaum Eye Chart removePortable Rebound Tonometer removeAutomatic Computer Goldmann (Visual Field Analyzer) removeOphthalmic AB Scan Machine removeSlit Lamp removeManual lensmeter remove
ImageMecan SW-500 Portable Rebound TonometerMecan SW-2100 Ultrasound BiometryMecan SLM-JX Slit Lamp SerialMecan Manual lensmeter NJC-4
SKUSF1033560130172-50SF1033560107-17SF103356013013SF1033560107-8SF1033560107-15SF1033560107-22
Rating
Price

$0.00

$1,815.00

$3,850.00

$4,895.00

$1,375.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad The Rosenbaum Pocket Vision Screening Card utilizing PV Numbers™ with Acuity Testing on Side 1 and Continuous Text Reading on Side 2. Includes Jaeger and Snellen notations, pupil gauge, and rulers.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from abroad Tonometer SW-500 with vertical and horizontal two working modes, wireless output print data.
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
In Stock
Features: The Bio-1000 automated perimeter absorbs the advantages of international advanced perimetry devices. It comprises the highly integrated computer, optics, machinery and electronics systems.   Delivery & Availability: Typically 7-14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from abroad
  • Software image workstation
  • B, B+B, B+A, A modes
  • Video review for 100 images
  • PDF report output
  • Optional 20MHz B Probe: vitreous plus function
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Shipped from abroad
  • Top Optical System.
  • High eyepoint, comfort.
  • Five steps drum zoom design, easier to use 6x, 10x, 16x, 25x, 40x magnification.
  • High Definition Eyepieces, More Comfortable for Viewing.
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Shipped from abroad The NJC-4 Lensmeter is used to measure the diopters of spherical lens and cylinder lens, the axis of cylinder lens, the strength and the baseline direction of shuttle lens, it can also stamp the optical center of lens, the axis of cylinder len and the base direction of shuttle lens.
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
ContentThe Rosenbaum Pocket Vision Screening Card utilizing PV Numbers™ provides 20/800 distance equivalent testing when held at a distance of 16 inches (40 cm). This card fits easily in a pocket for quick, convenient visual acuity screening. This Pocket Eye Chart is printed on durable plastic, and includes matching 20/200 Jaeger notation. Side 1 also includes pupil diameter gauge. Side 2 features continuous text format. This format helps to simulate everyday activities such as reading. This simulation leads to better testing of the patient and helps identify near vision problems that interfere with normal activities. Side 2 includes both metric and standard rulers.Tonometer SW-500 with vertical and horizontal two working modes, wireless output print data. The equipment is used to measure intraocular pressure, using the principle of:  the probe hits the surfaces of different hardness at a certain speed, has a different reaction when the probe rebounds. Be of advantages of high accuracy, portable, without anesthesia, without the cross-infection, etc. Features:
  • Measurement can go along both in standing and lying posture
  • Wireless data printing
  • Easy to learn, easy to use
  • Lightweight and handy
  • No anesthesia, avoiding discomfort reaction
Technical Specifications:
Performance Index:
Measuring Range : 3mmHg~70mmHg
Measuring Error: ±1.5mmHg(3mmHg≤intraocular pressure≤25mmHg)
±2.5mmHg(25mmHg<intraocular pressure≤70mmHg)
Environment Requirement:
Transport and Storage: Ambient temperature:-20℃~+55℃
Relative moisture:≦95%
Atmosphere pressure:500hPa~1060hPa
Running: Ambient temperature:+5℃~+40℃
Relative moisture:≦80%
Atmosphere pressure:700hPa~1060hPa
Rating voltage: DC3V(2 AA Batteries)
Rating input power:1VA
The Bio-1000 automated perimeter absorbs the advantages of international advanced perimetry devices. It comprises the highly integrated computer, optics, machinery and electronics systems. Incorporated with the advanced configuration, comprehensive software inspection categories, and strictly in accordance with international Goldman standard, it provide scientific means for glaucoma, fundus disease, visual pathway injury and neurological diseases. Feature:         * Comprehensive real-time monitoring,Heiji-krakau physiological blind spot monitoring,gaze tracking/head position tracking,automatic measurement of pupil diameter, reduce the impact of pupil effect on visual field detection. * Personalized design,accurate clinical analysis,accurate and repid examination strategy. * Under international Goldman standard,providing a variety of classic test procedures and report analysis. Technical Specification:
Inspection range 90°
Inspection distance 30cm
Background light brightness White 31.5abs
Visual target brightness 1abs --- 10000abs
Visual target size Goldmann III
Visual target interval time 200ms
Visual target interval time Stardard or adjustment according to patient reflection
Threshold test model Center5°- 16°,center10°- 68, 24-2, 30-2, 30°- 60°,nasal step
Upper threshold test model 30°-40,30°-76,P-60,60°-81,60°-120,190°-135,nasal side
Special detection strategy Esterman monocular,Esterman binocular,user-customized test,150°driver monocular fast detection, 150°driver monocular standard detection, upper36°detection, blind spot detection, 150° horizontal straightness detection
Pupil size test Automatic
Fixation monitoring Blind spot monitoring, eye position deviation alarm, eyedeviation curve
Enviroment light detection Automatic
Analysis software Reliability analysis,single vision report,triple visionreport,GPA half vision analysis, GPA glaucoma developing analysis, VFI vision index analysis
Operation system Win7 above
 
Click Here To Download Catalogue
Functions of Ophthalmic AB Scan Machine:
  • Software image workstation
  • B, B+B, B+A, A modes
  • Video review for 100 images
  • PDF report output
  • Optional 20MHz B Probe: vitreous plus function
Technical Specifications:
A scan 1.Probe: 10MHz frequencies, with LED 2.Depth: 40mm 3.Precision: ±0.05mm 4.Eye mode: Phakic / Aphakic / Dense / Various IOL 5.Measurement: Anterior chamber depth, lens thickness, vitreous body length, total length and average 6.IOL Formula: SRK-II, SRK-T, BINKHORST, HOLLADAY, HOFFER-Q, HAIGIS, Stat. 7.Calculation: Average and standard deviation 8.Store: 10 Scanning results for each eye
B scan 1.Probe: 10MHz/20MHz (optional), Magnetic driven, noiseless 2.Scanning Mode: Sector Scanning 3.Resolution: Lateral ≤0.3mm; Vertical≤0.2mm 4.Geometric Location Precision: Lateral≤10%; Vertical≤5% 5.Depth: 60mm 6.Enhance the part of vitreous body and retina 7.Gain of probe:30dB-105dB 8.Scanning Angle : 53° 9.Gray Scale: 256 10.False Color: Multi colors OTC 11.Measure Mode: distances, perimeter and area 12.Movies: 100 images movie review,AVI ZIP JPG format image output 13.Output: PDF format case report, connect to normal printer
Others 1.Display Mode :B, B+B, B+A, A 2.Hint: preset keyword 3.Case Search: Multi-keywords 4.Working Platform: Windows XP, VISTA, WINDOWS7 5.User-defined report template
Slit Lamp Features:
  • Top Optical System.
  • High eyepoint, comfort.
  • Five steps drum zoom design, easier to use 6x, 10x, 16x, 25x, 40x magnification.
  • High Definition Eyepieces, More Comfortable for Viewing.
Technical Specifications:
Microscope Type Galileo Parallel
Optics Super Optic System
Magnification Change Way Drum Rotation
Eyepiece Magnification 12.5x
Total Magnifications 6x 10x, 16x, 25x, 40x
Diopter Adjustment -5D ~+5D
Slit Width 0-14MM Continuous
Slit Height 1-14MM Continuous
Slit Angle 0°- 180° Adjustable
Light Source LED
Light Spot Diameter 0.2mm,  2mm, 3mm, 5mm, 10mm, 14mm
Filter Heat Absorption; Grey; Redfree; Cobalt Blue
Fixation Red LED
Electrical
Illumination Bulb LED
Input Voltage 110V/220V (±10%)
Applanation Tonometer Interface Included
 
The NJC-4 Lensmeter is used to measure the diopters of the spherical lens and cylinder lens, the axis of cylinder lens, the strength and the baseline direction of shuttle lens, it can also stamp the optical center of the lens, the axis of cylinder lens, and the base direction of shuttle lens. This instrument (Both Ac and Dc are permitted Two cells When Dc) has clear readings and graduations as well as high objective precision and reliabilities except that it can be operated easily and conveniently, AU the lenses and the made glasses can be measured by it, therefore, it is a required and ideal measuring instrument for glasses manufactures, glasses stores and ophthalmological hospitals. Technical Specifications:
  • Eyepiece focusing range: ±5D
  • The top point diopter measuring range: 0—±20D
  • The minimum measuring square value: 0.125D
  • The shuttle lens measuring range: 5A
  • The shuttle lens square value: 1A
  • The cylinder lens axial range: 0—180°
  • The cylinder lens axial square value: 5°
  • The maximum diameter of the measured lenses l00m/m
  • Power supply: AC 110V-6V DC 3V
  • Note: This item is AC 110V; The battery is not included!
 
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare