Sidestream Multigas Module AneSure-S
$0.00
Shipped From Abroad
Side stream Anesthesia Multi-Gas sensor can simultaneously measure the concentration waveform and data of CO2, N2O, anesthetic gases, as well as respiratory rate. The types of anesthetic gases measured include halothane, enflurane, isoflurane, sevoflurane, and desflurane. The user can manually select the type of anesthetic gas.
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
Features of Anesthesia Multi-gas Detector AneSure™-S
- Reliable multi-gas OEM solution
Reliable multi-gas OEM solution. Equipped With Oxygen Battery. Compatible with a variety of protocols, so that your products can be quickly upgraded and assembled.
- Side Stream Mode
Can simultaneously measure the concentration waveform and data of CO2, N2O, Anesthetic gas, as well as respiratory rate. The types of anesthetic gases measured include halothane, enflurane, isoflurane, sevoflurane, and desflurane. The user can manually select the type of anesthetic gas.
- Plug And Play
The host does not need an internal circuit, just a serial port. The sampling pump with super long service life can measure data within 4 seconds after power on. Suitable for adults, children and newborns. Advanced filter, can also be used in heavy humidity environment for a long time, reducing the cost of use.
- Automatic Pressure Compensation
There is a built-in atmospheric pressure sensor, which is suitable for various altitude ranges.
- High-precision
Careful selection of infrared devices, hardware design, and software algorithm, to achieve a high signal-to-noise ratio, to ensure the measurement accuracy for a temperature range of – 5-50 °C and in the range of 0 – 20%.
Specifications of Anesthesia Multi-gas Detector AneSure-S
Working condition | 5°C to 50°C, 10 to 90% RH, non-condensing |
Circumstance pressure | 55-115kpa |
Power consumption | <180 mA |
Interface | RS-232/Standard E-8-1, 38.4 kBaud,10 ms data interval (KM) or customization |
EtCO2, FiCO2 measurement | Range:0-150 mmHg, 0-20 kPa, 0-19.7%
Accuracy:±2mmHg for CO2 range 0 – 40mmHg ±5% for CO2 range from 41 – 70mmHg ±8% for CO2 range from 71 – 100mmHg ±10% Over 100mmHg |
Respiration rate | Range: 3-150 BPM
Accuracy: ±1% of reading or ±1 rpm whichever is greater |
FiN2O, EtN2O measurement | Range: 0-100%
Accuracy: ± (2 vol% + 2% of reading |
FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO measurement | Range: 0-12%
Accuracy: 0-8%: ± (0.15 vol% + 5% of reading) 8-12%: unspecified |
FiSEV, EtSEV measurement | Range: 0-15%
Accuracy: 0-10%: ± (0.15 vol% + 5% of reading) 10-15%: unspecified |
FiDES, EtDES measurement | Range:0-25%
Accuracy: 0-18%: ± (0.15 vol% + 5% of reading) 18-25%: unspecified |
Gas compensation | O2 (HOST supplied), or automatic compensation if O2 equipped |
Barometric Pressure | Having a barometric pressure sensor and automatic compensation |
Warm-up time | 10 seconds reach the designed deviation of 97%,
20 seconds reach the designed deviation. |
Rise times (t10- 90 %) | CO2:<200ms
N2O, AGENT: <300ms |
Flow control | Range: 50-250ml/min adjustable
Accuracy: <±20% |
Calibration | No need to calibrate |
Zero | Implement when the gas value’s offset is observed, or when any unspecified accuracy message is displayed |
Application Scenarios of Anesthesia Multi-gas Detector AneSure™-S
- Reliable multi-gas OEM solution. Equipped with Oxygen battery. Compatible with a variety of protocols, so that your products can be quickly upgraded and assembled.
- Side stream mode can simultaneously measure the concentration waveform and data of CO2, N2O anesthetic gas, as well as respiratory rate. The types of anesthetic gases measured include halothane, enflurane, isoflurane, sevoflurane, and desflurane. The user can manually select the type of anesthetic gas.
- Plug and play, the host does not need an internal circuit, just a serial port. The sampling pump with super long service life can measure data within 4 seconds after power on. Suitable for adults, children, and newborns. Advanced filters, can also be used in heavy humidity environments for a long time, reducing the cost of use.
- There is a built-in atmospheric pressure sensor, which is suitable for various altitude ranges.
- High-precision. Careful selection of infrared devices, hardware design, and software algorithm, to achieve a high signal-to-noise ratio, to ensure measurement accuracy for a temperature range of – 5-50 °C and in the range of 0 – 20%.
Quick Comparison
Settings | Sidestream Multigas Module AneSure-S remove | Render SD-M2000C+ Anesthetic Machine remove | MediPlus Bain Circuit (Adult) remove | Hersill Genesis Anaesthetic Machine remove | Anesthetic Face Mask remove | Spinal Epidural Pack remove | ||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | Sidestream Multigas Module AneSure-S remove | Render SD-M2000C+ Anesthetic Machine remove | MediPlus Bain Circuit (Adult) remove | Hersill Genesis Anaesthetic Machine remove | Anesthetic Face Mask remove | Spinal Epidural Pack remove | ||||||||||||||||||||||||||||||||||
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||||||||||||||||||||||||||||||
SKU | SF1033560011-11 | SF1033560084-21 | SF1033560450-1 | SF1033560084-141 | SF1033560084-25 | |||||||||||||||||||||||||||||||||||
Rating | ||||||||||||||||||||||||||||||||||||||||
Price |
| $4,070.00 | $28.00 |
| $8.00 |
| ||||||||||||||||||||||||||||||||||
Stock | ||||||||||||||||||||||||||||||||||||||||
Availability | ||||||||||||||||||||||||||||||||||||||||
Add to cart | ||||||||||||||||||||||||||||||||||||||||
Description | Shipped From Abroad
Side stream Anesthesia Multi-Gas sensor can simultaneously measure the concentration waveform and data of CO2, N2O, anesthetic gases, as well as respiratory rate. The types of anesthetic gases measured include halothane, enflurane, isoflurane, sevoflurane, and desflurane. The user can manually select the type of anesthetic gas.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from Abroad
| In Stock
| Shipped from Abroad The Genesis anaesthesia workstations meet your most ambitious requirements. They stand out for their lung protective ventilation. Application Field: Neonates, Pediatrics & Adults Ventilation Modes: Volume controlled (VC), Pressure controlled (PC), Adaptive Pressure with Volume Guaranteed (APVG) & Pressure Support Ventilation (PSV) Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
Four sizes from small adult to extra large adult. A range of color-coded economy anesthetic face masks for single patient use to prevent the possibility of cross infection.
| In Stock
It is for performing spinal/epidural or combined spinal/epidural or never-block loco-regional anaesthesia on patinet in clinical surgery.
Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | ||||||||||||||||||||||||||||||||||
Content | Features of Anesthesia Multi-gas Detector AneSure™-S
Reliable multi-gas OEM solution. Equipped With Oxygen Battery. Compatible with a variety of protocols, so that your products can be quickly upgraded and assembled.
Can simultaneously measure the concentration waveform and data of CO2, N2O, Anesthetic gas, as well as respiratory rate. The types of anesthetic gases measured include halothane, enflurane, isoflurane, sevoflurane, and desflurane. The user can manually select the type of anesthetic gas.
The host does not need an internal circuit, just a serial port. The sampling pump with super long service life can measure data within 4 seconds after power on. Suitable for adults, children and newborns. Advanced filter, can also be used in heavy humidity environment for a long time, reducing the cost of use.
There is a built-in atmospheric pressure sensor, which is suitable for various altitude ranges.
Careful selection of infrared devices, hardware design, and software algorithm, to achieve a high signal-to-noise ratio, to ensure the measurement accuracy for a temperature range of - 5-50 °C and in the range of 0 - 20%.
Specifications of Anesthesia Multi-gas Detector AneSure-S
Application Scenarios of Anesthesia Multi-gas Detector AneSure™-S
|
Click Here To Download Catalogue |
| The Genesis anaesthesia workstations meet your most ambitious requirements. They stand out for their lung protective ventilation, accuracy and performance, cost saving, design and ergonomics, safety and versatility.
TECHNICAL SPECIFICATION
OPERATING DATA
Click Here To Download Catalogue | Four sizes from small adult to extra large adult. A range of color-coded economy anesthetic face masks for single patient use to prevent the possibility of cross infection.
Features:
| It is for performing spinal/epidural or combined spinal/epidural or never-block loco-regional anaesthesia on patinet in clinical surgery.
Component:
| ||||||||||||||||||||||||||||||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||||||||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||||||||
Additional information |
Reviews
There are no reviews yet.