Features:
  • True Double conversion Technology
  • DSP digital control technology enable UPS more stable performance.
  • Three-level inverter technology
  • Active High input power factor correction technology (PFC)
  • Wide Input Voltage Frequency Range& Strong load capacity
  • Zero power switch delay
  • Compatible with Generators
  • Wide input voltage and frequency range can effectively isolate the harmful waves into power by the generator and provide pure,safe and stable power supply.
  • Support intelligent monitoring
  • Fully support remote intelligent monitoring with flexibility in choice of USB cards . AS400 cards , SNMP cards , RS485 cards
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Brands:: Reeco Power

Description

Features:
  • True Double conversion Technology
  • DSP digital control technology enable UPS more stable performance.
  • Three-level inverter technology
  • Active High input power factor correction technology (PFC)
  • Wide Input Voltage Frequency Range& Strong load capacity
  • Zero power switch delay
  • Compatible with Generators
  • Wide input voltage and frequency range can effectively isolate the harmful waves into power by the generator and provide pure,safe and stable power supply.
  • Support intelligent monitoring
  • Fully support remote intelligent monitoring with flexibility in choice of USB cards . AS400 cards , SNMP cards , RS485 cards
Applications:
  • Mammogram
  • Ultrasound Equipments
  • Radiology rooms

 

Technical Specifications
Model VT1K VT1KL VT2K VT2KL VT3K VT3KL
Rated power 1KVA/900KW 2KVA/1.8KW 3KVA/2.7KW
Input Voltage range 90~285Vac L+N+G
Frequency range 40-70Hz(Adjustable)
Input power factor >0.99
Output Rated voltage and precision 220Vac (1±2% ) L+N+G
Output frequency 46-54Hz Synchronous mains power; 50Hz( Frequency Range 40-46Hz ~54-60Hz);50Hz(Battery mode)
Rated Current 4.5A 9.1A 13.6A
Output power factor 0.9
Output harmonic ≤4%
Crest factor 3:1
Inverter overload capacity 105%±5%< Load<125%±5% : 50s transfer to bypass
125% ±5% < Load<150 % ±5 % : 25s transfer to bypass
Load > 150 % ± 5 %: 300s transfer to bypass
Transfer time 0ms
Efficiency ≥85%
Battery Rated voltage 24Vdc 36Vdc 48Vdc 72Vdc 72Vdc 96Vdc
Battery Numbers 2 3 4 6 6 8
Charge current 1A 6.5A 1A 5.5A 1A 5.5A
Size(LXWXH)mm 350*144*230 425*190*328
Net Weight(KG) 9.5kg 6kg 18.5kg 10kg 23.5kg 11kg
Operating temperature 0°C 〜40°C
Operating humidity 20% 〜95%
Noise ≤50dB

Reviews

There are no reviews yet.

Be the first to review “Single Phase High Frequency Online UPS VT Series 1KVA-3KVA”

Your email address will not be published. Required fields are marked *

Quick Comparison

Single Phase High Frequency Online UPS VT Series 1KVA-3KVA removeHigh Frequency Rack Mount UPS RTX Series removeHigh Frequency Modular UPS RM Pro Series removeLead Acid Maintenance Free Battery 5AH-250AH removeLine Interactive UPS AP Series 1000VA-3000VA remove3 Phase Low Frequency Online UPS LD33 Series remove
NameSingle Phase High Frequency Online UPS VT Series 1KVA-3KVA removeHigh Frequency Rack Mount UPS RTX Series removeHigh Frequency Modular UPS RM Pro Series removeLead Acid Maintenance Free Battery 5AH-250AH removeLine Interactive UPS AP Series 1000VA-3000VA remove3 Phase Low Frequency Online UPS LD33 Series remove
Image
SKU
Rating
Price

Ask for Price$0.00

Ask for Price$0.00

Ask for Price$0.00

Ask for Price$0.00

Ask for Price$0.00

Ask for Price$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
Features:
  • True Double conversion Technology
  • DSP digital control technology enable UPS more stable performance.
  • Three-level inverter technology
  • Active High input power factor correction technology (PFC)
  • Wide Input Voltage Frequency Range& Strong load capacity
  • Zero power switch delay
  • Compatible with Generators
  • Wide input voltage and frequency range can effectively isolate the harmful waves into power by the generator and provide pure,safe and stable power supply.
  • Support intelligent monitoring
  • Fully support remote intelligent monitoring with flexibility in choice of USB cards . AS400 cards , SNMP cards , RS485 cards
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Features:
1)19 inches standard design of rack mount, compact structure. 2)Sin wave output provides best power supply guarantee. 3)Zero transfer time between mains mode and battery mode. 4)Detection function of input neutral wire and live wire. 5)Having voltage surge protection function and strong anti-interference function. 6)Equipped with correction function of input power factor 7) Supporting mobile smart monitoring card , users can real-time monitor every data of the UPS by mobile APP.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Features:
  • 60KW single power module in 3U
  • N+1or N+X parallel redundancy for power guarantee
  • Supports horizontal expansion by 1+1 cabinet paralleloperation.
  • Hot-swappable modular design decreases MTTR
  • High scalability
  • Built-in maintenance bypass switch for easy maintenance without interruptible
  • High efficiency double conversion online UPS
  • Flexible battery configuration and adjustable charging current
  • High overload capability
  • Power walk-in function
  • Built-in dynamic password protection
  • Built-in ultra communication slot
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
f
Shipped From Abroad
Features:
  • Pure sine wave output
  • DSP digital control
  • Boost and buck AVR for voltage stabilization
  • Cold start function
  • Intelligent battery management
  • Short circuit and overload protection
  • Off-mode charging
  • Offering LED and LCD panels for selection
  • Optional USB/RS232/RJ45/SNMP communication port
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Features:
  • True Double conversion Technology
  • DSP digital control technology enable UPS more stable performance.
  • Three-level inverter technology
  • Active High input power factor correction technology (PFC)
  • Wide Input Voltage Frequency Range& Strong load capacity
  • Zero power switch delay
  • Compatible with Generators
  • Wide input voltage and frequency range can effectively isolate the harmful waves into power by the generator and provide pure,safe and stable power supply.
  • Support intelligent monitoring
  • Fully support remote intelligent monitoring with flexibility in choice of USB cards . AS400 cards , SNMP cards , RS485 cards
Applications:
  • Mammogram
  • Ultrasound Equipments
  • Radiology rooms
 
Technical Specifications
Model VT1K VT1KL VT2K VT2KL VT3K VT3KL
Rated power 1KVA/900KW 2KVA/1.8KW 3KVA/2.7KW
Input Voltage range 90~285Vac L+N+G
Frequency range 40-70Hz(Adjustable)
Input power factor >0.99
Output Rated voltage and precision 220Vac (1±2% ) L+N+G
Output frequency 46-54Hz Synchronous mains power; 50Hz( Frequency Range 40-46Hz ~54-60Hz);50Hz(Battery mode)
Rated Current 4.5A 9.1A 13.6A
Output power factor 0.9
Output harmonic ≤4%
Crest factor 3:1
Inverter overload capacity 105%±5%< Load<125%±5% : 50s transfer to bypass 125% ±5% < Load<150 % ±5 % : 25s transfer to bypass Load > 150 % ± 5 %: 300s transfer to bypass
Transfer time 0ms
Efficiency ≥85%
Battery Rated voltage 24Vdc 36Vdc 48Vdc 72Vdc 72Vdc 96Vdc
Battery Numbers 2 3 4 6 6 8
Charge current 1A 6.5A 1A 5.5A 1A 5.5A
Size(LXWXH)mm 350*144*230 425*190*328
Net Weight(KG) 9.5kg 6kg 18.5kg 10kg 23.5kg 11kg
Operating temperature 0°C 〜40°C
Operating humidity 20% 〜95%
Noise ≤50dB
Features:
1)19 inches standard design of rack mount, compact structure. 2)Sin wave output provides best power supply guarantee. 3)Zero transfer time between mains mode and battery mode. 4)Detection function of input neutral wire and live wire. 5)Having voltage surge protection function and strong anti-interference function. 6)Equipped with correction function of input power factor 7) Supporting mobile smart monitoring card , users can real-time monitor every data of the UPS by mobile APP.  
Technical Specifications
Model RTX3110KL RTX3115KL RTX3120KL
Rated Power 10kVA/9kW 15kVA/13.5kW 20kVA/18kW
INPUT Voltage Range 207-475Vac3P4W+G
Working Frequency Range 40-70HZ (settable)
Input Power Factor >0.95
OUTPUT Rated Voltage and Accuracy 220Vac(l±l%)lP2W+G
Output Frequency 46-54Hz synchronize with mains power; 50Hz (Mains power between 40-46Hz and 54-60Hz); 50Hz(Battery)
Rated Current 45A 68A 91A
Output Power Factor 0.9
Output Harmonic Wave W3%
Crest Factor  3:1
Output Overload 105%±5%<Load≤125%±5%: Convert to bypass output and alarm after 1 min; 125%±5%<Load ≤50%±5%: Convert to bypass output and alarm after 30s; Load>150%±5%: Convert to bypass output and alarm after 300ms.
Transfer Time 0ms
Efficiency >92%
BATTERY Rated Voltage 192Vdc
Quantity 16
Charging Current 5.5A
Dimension (LxWxH) mm 665*482.6*132.5 655*482.6*265
Weight 23kg 34kg 35kg
Working Temperature 0°〜40°C
Working Humidity 20% 〜95%
Noise ≤60dB
Features:
  • 60KW single power module in 3U
  • N+1or N+X parallel redundancy for power guarantee
  • Supports horizontal expansion by 1+1 cabinet paralleloperation.
  • Hot-swappable modular design decreases MTTR
  • High scalability
  • Built-in maintenance bypass switch for easy maintenance without interruptible
  • High efficiency double conversion online UPS
  • Flexible battery configuration and adjustable charging current
  • High overload capability
  • Power walk-in function
  • Built-in dynamic password protection
  • Built-in ultra communication slot
 
Technical Specifications
MODEL RM Pro 120K RM Pro 180K RM Pro 300K RM Pro 420K RM Pro 480K RM Pro 600K
Phase 3 Phase in / 3 Phase out
Cabinet Capacity* 120 KW 180 KW 300KW 420KW 480KW 600KW
Battery  Type Extemal Battery
One Power Module Capacity 60KVA/60KW
Max.   Power Module  No. 2 3 5 7 8 10
INPUT
Nominal Voltage 3×380/400/415   VAC(3Ph+N)
Voltage Range -30%~+20%
Nominal Frequency 50/60Hz(Auto Sensing)
Frequency Range 40Hz~70Hz
Power Factor >0.99  @100%  Load, >0.98 @ 50%  Load
Harmonic  Distortion   (THDi) <3%@  100%  load
OUTPUT
Nominal Voltage 3×380/400/415 VAC (3Ph+N)
Voltage  Regulation(Steady  State) ≤±1% Typical(balanced load); ≤±2% Typical(unbalanced load)
Nominal Frequency 50/60Hz
Frequency Range(Synchronized) 46Hz~54Hz or 56Hz~64Hz
Overload Capability 1 hour for ≤110%,10 mins for 111%~125%,1 min for 126%~150% and 200ms for >150%
Haronic Distortion ≤2% THD (Linear Load);  ≤4% THD (Non-linear Load)
Eficiency 96%
BATTERY / CHARGER
Nominal Voltage ’+/- 192V~+/- 240V(Selectable)
Maximum Voltage ’+/- 240V (12V×40 PCS)
Minimum Voltage ‘+/-192V (12V×32 PCS)
Floating Charge Voltage 2.28V/Cell (2.25~2.33 Selectable)
Boost Charging Voltage 2.35V/Cell
Temperature Compensation Yes
Maximum Charging Current (Per Power Module) 18A(Adjustable)
PHYSICAL
Cabinet Dimension (DxWxH)mm 1100x600x1475 1100x600x1475 1100x600x2010 1100×600×2010 1065x1000x2000 1065×1000×2000
Net Weight (Kg) 308 352 516 654 932 1020
Power Module (PM-60) Net Weight 44KGS
ENVIRONMENT
Operating Temperature 0~40℃
Relative Humidity 0~95% non-condensing
Altitude* <1000m for Nominal power
IP  Protection IP 20
MANAGEMENT
Smart  RS-232/USB Supports Windows⑧ Family, Linux and MAC
Optional SNMP Power management from SNMP manager and web browser
STANDARDS
Safety IEC/EN62040-1
EMC IEC/EN 62040-2 Category C3
Features:
Nomimal voltage: 12V Rated Capacity: 5Ah ~ 250Ah Operating temperature range: -15 ~ 45 ℃ The design life is 5 years Using new special process sheet formula to improve the utilization of active material Using high quality superfine glass fiberliquid-suction battery technology to exceed 99% gas recombination rate High-strength ABS plastic battery slot and cover with features of compact structure, corrosion resistant, impact resistance and anti-vibration and so on Small internal impedance, excellent performance when high current discharge Low self-discharge, wide operating temperature range Using multiple sealing technologies to ensure no leakage, no acid mist escaping to keep safe and reliable Using strict production process, unit voltage balance is strong Free maintenance, without adding water rehydration  
Technical Specifications
Model Nominal Voltage Capacity Dimension LXWXH (mm) Total Height (mm) Weight (KG) Terminal
VL12-24 12 24 166 175 125 125 8 M6
VL12-28 12 28 166 175 125 125 9 M6
VL12-33 12 33 196 130 163 180 10 M6
VL12-35 12 35 197 130 163 180 10.5 M6
VL12-40 12 40 197 166 171 171 13.5 M6
VL12-44 12 44 196 166 171 171 13.5 M6
VL12-55 12 55 230 138 211 229 17.2 M6
VL12-65 12 65 350 166 179 179 22 M6
VL12-70 12 70 260 169 211 229 23 M8
VL12-80 12 80 260 169 211 229 24 M8
VL12-90 12 90 307 169 211 234 28 M8
VL12-100 12 100 331 173 213 233 32 M8
VL12-120 12 120 407 174 209 233 3, 8 M8
VL12-130 12 134 341 173 283 287 41 M8
VL12-150 12 150 484 171 241 241 46 M8
VL12-160 12 160 534 209 216 237 52 M8
VL12-180 12 180 530 209 216 237 56 M8
VL12-200 12 200 522 240 220 244 64 M8
VL12-230 12 230 520 268 220 240 72.5 M8
VL12-250 12 250 520 268 220 249 76 M8
Features:
  • Pure sine wave output
  • DSP digital control
  • Boost and buck AVR for voltage stabilization
  • Cold start function
  • Intelligent battery management
  • Short circuit and overload protection
  • Off-mode charging
  • Offering LED and LCD panels for selection
  • Optional USB/RS232/RJ45/SNMP communication port
 
Technical Specifications
 
MODEL UPS-AP1K ( L ) UPS-AP2K ( L ) UPS-AP3K ( L )
Capacity 1000VA/700W 2000VA/1400W 3000VA/2100W
INPUT
Voltage range 145~275VAC±5V
Frequency range 50Hz-60Hz
OUTPUT
Output voltage 220VAC
AC voltage range ±10%
Frequency range(batt.mode) 50Hz ± 0.25Hz or 60Hz ± 0.3Hz
Overload 105%-110%: UPS beep alarm, do not shut down.
110%-130%: auto shut down after 30 seconds
> 130%: auto shut down immediately
Transfer time <typical 4ms
Waveform(batt.mode) Pure sine wave
BATTERY
Standard model Battery type 12V7Ah
Numbers 2 4 6
Charging current(Max.) Assume: 1A± 10%; Max: 1A or 2A for option
Charging voltage 27.3VDC±1% 54.7VDC±1% 82.0VDC±1%
Long-run model Battery type 12V, AH depending on applicant
Numbers 3 6 8
Charging current(Max.) > 5A
Charging voltage 27.4VDC±1% 82.1VDC±1% 109.4VDC±1%
PHYSICAL
Standard model Dimension, LxWxH(mm) 360x147x220 440x192x340 440x192x340
Net weight(kgs) 11.9 22 27.9
Long-run model Dimension, LxWxH(mm) 360x147x220 440x192x340 440x192x340
Net weight(kgs) 8.5 16 18.2
ENVIRONMENT
Humidity 20-90%RH @0-40°C (non-condensing)
Noise level Less than 55dBA@1 Meter
MANAGEMENT
Smart RS-232 Support windows 2000/2003/XP/Vista/2008, Windows7/8, Linux, Unix, and MAC
Optional SNMP Power management from SNMP Management and web browser
Description
HIGH INTELLIGENCE AND RELIABLE POWER SUPPLY IGBT Technology Full microprocessor control with no-break static and manual bypasses. Online double conversion technology (VFl) with isolation transformer on theinverter output. Extremely high short-circuit current to ensure compatibility with the most diffificult transformer applications (lighting, drives and industrial processes) and an isolation transformer on the inverter output. Compatibled with Watch & Save 3000 software as standard and can be remotely monitored using the Power NetGuard system from anywhere in the world. SIMPLE TO INSTALL Capability to install the UPS into any distribution system(neutral not required on rectifier input). Capability to separate the rectifier/bypass power networks and to power them from two separate sources, without Galvanic isolation(Necessary on UPS without an output transformer MAXIMUM BATTERY CARE Battery deep discharge protection; Temperature compensating charger; Built-in automatic and manual battery test feature. OTHER CHARACTERISTICS 0.8/0.9 power factor suitable for powering ICT and lndustrial loads. BACK FEED protection: to avoid energy feeding back into the mains supply cause a fault occur. MAXIMUM RELIABILITY AND AVAILABILITY Connect up to 6 units in parallel or N+1 redundancy, even of different power ratings. The UPS continue to work in parallel even if one of theinterconnecting communication cables is disconnected(CLOSED LOOP) LOW CONSUMPTION LEVELS LF33 Series UPS can achieve efficiencies >98% thanks to selectable Economy Mode which can be used in stable electrical environments to provide power supply continuity when the mains fail. ADVANCE COMMUNICATION: RS485/RS232/Dry Contact/SNMP(Optional)  
Specifications
Model 10KVA 20KVA 30KVA 40KVA 60KVA 80KVA 100KVA 120KVA 160KVA 200KVA 250KVA 300KVA 400KVA 500KVA 600KVA
Capacity 8KW 16 KW 24 KW 32 KW  48 KW 64 KW  80 KW 96 KW 128 KW 160 KW 200KW 240KW 320KW 400KW  480KW
INPUT
Rated voltage 400 VAC  Three-Phase
Voltage range 380/400/415VAC(+25%,Can be set through the LCD panel)
Frequency range 40-70Hz(Automatically select synchronization range according to grid frequency)
Range(HZ) 50±5%(±10%) Bypass synchronization tracking
Rectifying pulse number 6 pulse rectification 6/12 pulse rectification 12 pulse rectifier
Phase system 3φ4W+PE(Three phase five wire system)
Battery voltage 384VDC 480VDC
Battery Quantity Standard with 32 Cells(30~34, can be set through the LCD panel)  Standard 40 Cells(38~42 knots,can be set by LCD panel)
OUTPUT
Power factor 0.8/0.9 (Optional)
Voltage(V) L-N: 220±1%   L-L: 380±1%
Three-phase 100% load unbalance voltage stability ≤2%,Allow 100% imbalance
Frequency(HZ) Normal power, tracking the frequency of power, Grid abnormal. 50±0.2%
Transfer time(ms) 0ms
Parallel operation mode (parallel type) Max 8 Parallel
Waveform distortion Linear loadTHD<3% ; Nonlinear loadTHD<5%
Overload capacity 125% full load for 10 minutes, maintain 150 % full load for 1 minute and then switch to bypass power supply, after reducing the loadcan automatically restore the inverter
Crest factor 3:1
Others
Index Standard with no transfer time maintenance bypass switch
Communication function RS232/RS485/Dry Contact/SNMP (Optional)
Panel display LED displays working status and fault indication; LCD displays three-phase input voltage, input frequency, three-phase output voltage, load,battery voltage, battery charge and discharge current, etc
Display  7″ Touchable LCD screen display
The audio noise(dB) <65(within 1 meter)
Alarm function Battery low voltage, abnormal power supply, overload, UPS failure, over temperature protection
Protection Input over voltage, battery under voltage, overload, short circuit, over temperature protection
Cooling way Forced cooling
Operating temperature 0℃ to  ~ 40℃
Humidity 0~95%, non-condensing
electromagnetic compatibility Conform GB7260.2
Size(W*D*H)(mm) 540*660*1135 1100*800*1800 800*800*1900 1200*850*1900 2600*1100*2000
Weight 196     233 276 329 461 547.5 643 754 1375
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar