Description | Shipped From Abroad
Features:
- True Double conversion Technology
- DSP digital control technology enable UPS more stable performance.
- Three Level inverter control technology
- Large screen LCD display
- N+X Parallel Redundancy function (3 units parallel)
- EPO emergency stop function
- Smart expansion Slots (optional)
- Support Generator
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
f | | Shipped From Abroad
Features:
- 60KW single power module in 3U
- N+1or N+X parallel redundancy for power guarantee
- Supports horizontal expansion by 1+1 cabinet paralleloperation.
- Hot-swappable modular design decreases MTTR
- High scalability
- Built-in maintenance bypass switch for easy maintenance without interruptible
- High efficiency double conversion online UPS
- Flexible battery configuration and adjustable charging current
- High overload capability
- Power walk-in function
- Built-in dynamic password protection
- Built-in ultra communication slot
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Features:
- Compact Size with nice housing case design. Stable performance with strong compatibility.
- Built-in adapter, wide input, voltage range (100-240VAC).
- Built-in multiple DC voltage (5/9/12/24/48VDC)output interfaces which can be used with external power adapters or solar panel.
- Built-in large capacity lithium-ion batteries which is expanded up to 165Wh for long backup time.
- 100W has 19VDC output, it can be used for desktop computer / laptop computer.
- 60W/100W with WIFI function, it can be connected to the upper computer control. ( wall mounted type and tower type design).
- Customize various of plugs and DC interfaces.
- LCD indicator display design for monitor the working status easier.
- Built-in multiple protection circuits, intelligently realize overcharge, over discharge, over current, overload, over temperature and short circuit protection
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Features:
- 50KW single power module in 3U
- N+1or N+X parallel redundancy for power guarantee
- Supports horizontal expansion by 1+1 cabinet paralleloperation.
- Hot-swappable modular design decreases MTTR
- High scalability
- Built-in maintenance bypass switch for easy maintenance without interruptible
- High efficiency double conversion online UPS
- Flexible battery configuration and adjustable charging current
- High overload capability
- Power walk-in function
- Built-in dynamic password protection
- Built-in ultra communication slot
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
|
Content | Features:
- True Double conversion Technology
- DSP digital control technology enable UPS more stable performance.
- Three Level inverter control technology
- Large screen LCD display
- N+X Parallel Redundancy function (3 units parallel)
- EPO emergency stop function
- Smart expansion Slots (optional)
- Support Generator
Applications:
- Mammogram
- Ultrasound Equipments
- Radiology rooms
Technical Specifications
Model |
VT6K |
VT6KL |
VT10K |
VT10KL |
31VT10KL |
31VT15KL |
31VT20KL |
Capacity |
6KVA/5400W |
10KVA/9000W |
15KVA/13.5KW |
20KVA/18KW |
Input |
Nominal Voltage |
220/230/240Vac |
380/400/415Vac |
Voltage Range |
120-275VAC(1P2W+G) |
207-475VAC(3P4W+G) |
Current |
31A (max) |
50A(max) |
50A (max) |
75A(max) |
100A(max) |
Frequency |
46-54Hz Synchronous mains power; 50Hz( Frequency Range 40-46Hz ~54-60Hz);50Hz(Battery mode) |
Power Factor |
≥0.99· |
Output |
Voltage |
220/230/240±2%Vac (1P2W+G) |
Frequency |
50/60 Hz(adjustable)
50/60Hz± 5% (Line mode)
50/60Hz ± 0.05Hz ( Battery mode) |
Current |
27.3A |
45A |
68A |
91A |
Power Factor |
0.9 |
Waveform |
Pure Sine Wave |
Waveform Distortion |
Line load <2% |
Line load <3% |
Back-up Time |
Full Load |
≥7′ |
Depends on external batteries bank’s Capacity |
≥5′ |
Depends on external batteries bank’s Capacity |
Half Load |
≥20 |
≥13′ |
Battery Nominal Voltage |
192/240Vdc |
Transfer Time |
0ms |
Overload Capacity |
105%±5%< Load<125%±5% :1 min transfer to bypass
125% ±5% < Load<135 % ±5 % :30s transfer to bypass
Load > 135 % ± 5 %: 300s transfer to bypass |
Communication |
SNMP,RS-232,USB+lntelligent Slot |
Operating Environment |
Temperature |
0°C~40°C |
Humidity |
15%~90% |
Dimension |
Width (mm) |
260 |
260 |
260 |
260 |
260 |
Depth (mm) |
560 |
533 |
560 |
533 |
560 |
Height (mm) |
717 |
501 |
717 |
501 |
717 |
Net Weight(Kg) |
55 |
12.2 |
62 |
21 |
23 |
32 |
33 |
| Features:
Nomimal voltage: 12V
Rated Capacity: 5Ah ~ 250Ah
Operating temperature range: -15 ~ 45 ℃
The design life is 5 years
Using new special process sheet formula to improve the utilization of active material
Using high quality superfine glass fiberliquid-suction battery technology to exceed 99% gas recombination rate
High-strength ABS plastic battery slot and cover with features of compact structure, corrosion resistant, impact resistance and
anti-vibration and so on
Small internal impedance, excellent performance when high current discharge
Low self-discharge, wide operating temperature range
Using multiple sealing technologies to ensure no leakage, no acid mist escaping to keep safe and reliable
Using strict production process, unit voltage balance is strong
Free maintenance, without adding water rehydration
Technical Specifications
Model |
Nominal Voltage |
Capacity |
Dimension LXWXH (mm) |
Total Height
(mm) |
Weight (KG) |
Terminal |
VL12-24 |
12 |
24 |
166 |
175 |
125 |
125 |
8 |
M6 |
VL12-28 |
12 |
28 |
166 |
175 |
125 |
125 |
9 |
M6 |
VL12-33 |
12 |
33 |
196 |
130 |
163 |
180 |
10 |
M6 |
VL12-35 |
12 |
35 |
197 |
130 |
163 |
180 |
10.5 |
M6 |
VL12-40 |
12 |
40 |
197 |
166 |
171 |
171 |
13.5 |
M6 |
VL12-44 |
12 |
44 |
196 |
166 |
171 |
171 |
13.5 |
M6 |
VL12-55 |
12 |
55 |
230 |
138 |
211 |
229 |
17.2 |
M6 |
VL12-65 |
12 |
65 |
350 |
166 |
179 |
179 |
22 |
M6 |
VL12-70 |
12 |
70 |
260 |
169 |
211 |
229 |
23 |
M8 |
VL12-80 |
12 |
80 |
260 |
169 |
211 |
229 |
24 |
M8 |
VL12-90 |
12 |
90 |
307 |
169 |
211 |
234 |
28 |
M8 |
VL12-100 |
12 |
100 |
331 |
173 |
213 |
233 |
32 |
M8 |
VL12-120 |
12 |
120 |
407 |
174 |
209 |
233 |
3, 8 |
M8 |
VL12-130 |
12 |
134 |
341 |
173 |
283 |
287 |
41 |
M8 |
VL12-150 |
12 |
150 |
484 |
171 |
241 |
241 |
46 |
M8 |
VL12-160 |
12 |
160 |
534 |
209 |
216 |
237 |
52 |
M8 |
VL12-180 |
12 |
180 |
530 |
209 |
216 |
237 |
56 |
M8 |
VL12-200 |
12 |
200 |
522 |
240 |
220 |
244 |
64 |
M8 |
VL12-230 |
12 |
230 |
520 |
268 |
220 |
240 |
72.5 |
M8 |
VL12-250 |
12 |
250 |
520 |
268 |
220 |
249 |
76 |
M8 |
| Features:
Three Phase Hybrid Solar Inverter
Off grid three phase solar hybrid inverter with pwm/mppt can be used in single-phase and three-phase ac load with total power not exceeding 100kva/120kva/125kva/150kva/160kva,384vdc to 380vac.
•Pure sine wave output.
•Low DC voltage, saving system cost.
•Three phase solar inverter with built-in PWM or MPPT charge controller.
•AC charge current 0-45A adjustable.
•Wide LCD screen, clearly and precisely shows icon data.
•100%imbalance loading design, 3 times peak power.
•Setting different working modes based on variable usage requirements.
•DC first/AC first optional.
•Various communication ports and remote controls
Specifications
MODEL |
DX100KVA |
DX120KVA |
DX125KVA |
DX150KVA |
DX160KVA |
190KVA |
200KVA |
Rated Power |
80KW |
96KW |
100KW |
120KW |
128KW |
150KW |
160KW |
Peak Power(20ms) |
240KVA |
288KVA |
300KVA |
360KVA |
384KVA |
450KVA |
480KVA |
Start Motor |
40HP |
50HP |
50HP |
60HP |
60HP |
80HP |
80HP |
Battery Voltage |
384VDC |
Size(L*W*Hmm) |
875*720*1380 |
1123*900*1605 |
Packing Size(L*W*Hmm) |
980*825*1560 |
1185*960*1750 |
N.W.(kg) |
512 |
592 |
612 |
612 |
642 |
705 |
755 |
G.W.(kg)(Wooden Packing) |
552 |
632 |
652 |
652 |
692 |
755 |
805 |
INPUT |
DC Input Voltage Range |
10.5VDC-15VDC(Single battery voltage) |
AC Input Voltage Range |
380Vac/400Vac±10%(customized 190Vac/200Vac) |
AC Input Frequency Range |
45Hz-55Hz(50Hz)/ 55Hz-65Hz(60Hz) |
Max AC charging current |
0-45A(Depending on the model) |
AC charging method |
Three-stage (constant current, constant voltage, floating charge) |
Phase |
3 PHASE |
OUTPUT |
Efficiency(Battery Mode) |
≥85% |
Output Voltage(Battery Mode) |
380Vac/400Vac±10%(customized 190Vac/200Vac) |
Output Frequency(Battery Mode) |
50/60Hz ±1% |
Output Wave(Battery Mode) |
Pure Sine Wave |
Output waveform distortion |
Linear load≤3% |
Efficiency(AC Mode) |
>99% |
Output Voltage(AC Mode) |
Conforming to AC input |
Output Frequency(AC Mode) |
Conforming to AC input |
No load loss(Battery Mode) |
≤1% rated power |
No load loss(AC Mode) |
≤2%rated power( charger does not work in AC mode) |
No load loss
(Energy saving Mode) |
≤10W |
Phase |
3 PHASE |
BATTERY |
VRLA Battery |
Charge Voltage :13.8V; Float Voltage:13.7V(Single battery voltage) |
Customize battery |
Charging and discharging parameters of different types of batteries can be customized according to user requirements |
(charging and discharging parameters of different types of batteries can be set through the operation panel) |
Protection |
Battery undervoltage alarm |
11V(Single battery voltage) |
Battery undervoltage protection |
10.5V(Single battery voltage) |
Battery overvoltage alarm |
15V(Single battery voltage) |
Battery overvoltage protection |
17V(Single battery voltage) |
Battery overvoltage recovery voltage |
14.5V(Single battery voltage) |
Overload power protection |
Automatic protection (battery mode), circuit breaker or insurance (AC mode) |
Inverter output short circuit protection |
Automatic protection (battery mode), circuit breaker or insurance (AC mode) |
Temperature protection |
>90°C(Shut down output) |
Alarm |
A |
Normal working condition, buzzer has no alarm sound |
B |
Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection |
C |
When the machine is turned on for the first time, the buzzer will prompt 5
when the machine is normal |
Inside Solar controller |
Charging Mode |
MPPT or PWM |
(Optional) |
Charging current |
PWM: 100A-200A / MPPT: 50A/100A |
|
PV Input Voltage Range |
PWM: 480V-704V / MPPT: 480V-640V |
|
Max PV Input Voltage(Voc) |
PWM: 750V / MPPT: 800V |
|
(At the lowest temperature) |
|
PV Array Maximum Power |
PWM: 44.8KW(100A)/33.6KW*2(150A)/44.8KW*2(200A)) / (MPPT: 22.4KW(50A)/22.4KW*2(100A) |
|
Standby loss |
≤3W |
|
Maximum conversion efficiency |
>95% |
Working Mode |
Battery First/AC First/Saving Energy Mode |
Transfer Time |
≤4ms |
Display |
LCD |
Thermal method |
Forced Air Cooling |
Communication(Optional) |
RS485/APP(WIFI monitoring or GPRS monitoring) |
Environment |
Operating temperature |
-10℃~40℃ |
Storage temperature |
-15℃~60℃ |
Noise |
2000m(More than derating) |
Elevation |
≤65dB |
Humidity |
0%~95% ,No condensation |
| Features:
- 60KW single power module in 3U
- N+1or N+X parallel redundancy for power guarantee
- Supports horizontal expansion by 1+1 cabinet paralleloperation.
- Hot-swappable modular design decreases MTTR
- High scalability
- Built-in maintenance bypass switch for easy maintenance without interruptible
- High efficiency double conversion online UPS
- Flexible battery configuration and adjustable charging current
- High overload capability
- Power walk-in function
- Built-in dynamic password protection
- Built-in ultra communication slot
Technical Specifications
MODEL |
RM Pro 120K |
RM Pro 180K |
RM Pro 300K |
RM Pro 420K |
RM Pro 480K |
RM Pro 600K |
Phase |
3 Phase in / 3 Phase out |
Cabinet Capacity* |
120 KW |
180 KW |
300KW |
420KW |
480KW |
600KW |
Battery Type |
Extemal Battery |
One Power Module Capacity |
60KVA/60KW |
Max. Power Module No. |
2 |
3 |
5 |
7 |
8 |
10 |
INPUT |
Nominal Voltage |
3×380/400/415 VAC(3Ph+N) |
Voltage Range |
-30%~+20% |
Nominal Frequency |
50/60Hz(Auto Sensing) |
Frequency Range |
40Hz~70Hz |
Power Factor |
>0.99 @100% Load, >0.98 @ 50% Load |
Harmonic Distortion (THDi) |
<3%@ 100% load |
OUTPUT |
Nominal Voltage |
3×380/400/415 VAC (3Ph+N) |
Voltage Regulation(Steady State) |
≤±1% Typical(balanced load); ≤±2% Typical(unbalanced load) |
Nominal Frequency |
50/60Hz |
Frequency Range(Synchronized) |
46Hz~54Hz or 56Hz~64Hz |
Overload Capability |
1 hour for ≤110%,10 mins for 111%~125%,1 min for 126%~150% and 200ms for >150% |
Haronic Distortion |
≤2% THD (Linear Load); ≤4% THD (Non-linear Load) |
Eficiency |
96% |
BATTERY / CHARGER |
Nominal Voltage |
’+/- 192V~+/- 240V(Selectable) |
Maximum Voltage |
’+/- 240V (12V×40 PCS) |
Minimum Voltage |
‘+/-192V (12V×32 PCS) |
Floating Charge Voltage |
2.28V/Cell (2.25~2.33 Selectable) |
Boost Charging Voltage |
2.35V/Cell |
Temperature Compensation |
Yes |
Maximum Charging Current
(Per Power Module) |
18A(Adjustable) |
PHYSICAL |
Cabinet Dimension (DxWxH)mm |
1100x600x1475 |
1100x600x1475 |
1100x600x2010 |
1100×600×2010 |
1065x1000x2000 |
1065×1000×2000 |
Net Weight (Kg) |
308 |
352 |
516 |
654 |
932 |
1020 |
Power Module (PM-60) Net Weight |
44KGS |
ENVIRONMENT |
Operating Temperature |
0~40℃ |
Relative Humidity |
0~95% non-condensing |
Altitude* |
<1000m for Nominal power |
IP Protection |
IP 20 |
MANAGEMENT |
Smart RS-232/USB |
Supports Windows⑧ Family, Linux and MAC |
Optional SNMP |
Power management from SNMP manager and web browser |
STANDARDS |
Safety |
IEC/EN62040-1 |
EMC |
IEC/EN 62040-2 Category C3 |
| Features:
- Compact Size with nice housing case design. Stable performance with strong compatibility.
- Built-in adapter, wide input, voltage range (100-240VAC).
- Built-in multiple DC voltage (5/9/12/24/48VDC)output interfaces which can be used with external power adapters or solar panel.
- Built-in large capacity lithium-ion batteries which is expanded up to 165Wh for long backup time.
- 100W has 19VDC output, it can be used for desktop computer / laptop computer.
- 60W/100W with WIFI function, it can be connected to the upper computer control. ( wall mounted type and tower type design).
- Customize various of plugs and DC interfaces.
- LCD indicator display design for monitor the working status easier.
- Built-in multiple protection circuits, intelligently realize overcharge, over discharge, over current, overload, over temperature and short circuit protection
Specifications
Model |
DCP-45W |
DCP-60W |
DCP-100W |
DCP-120W |
Input voltage |
100-240Vac/50-60Hz |
12-24Vdc (2.5A Max) |
|
1*9/12V(2A) (selectable) |
Output voltage |
4*12V(3.5A) |
Standard: 4*12V(5A)
Customized: 3*12V(5A)+1*19V(3A) |
Standard: 4*12V(8A)
Customized: 3*12V(8A)+1*19V(5A) |
Standard: 4*12V(10A)
Customized: 3*12V(10A)+1*19V(6A) |
1*5VDC+2*USB (2.4A) |
Standard:
1*24(1.2A) /48V(0.6A)(POE 1 Gbps) (Selectable)
Customized:
1)2*24(1.2A) /48V(0.6A)(POE 1 Gbps) (Selectable)
2)1*24(1.2A) /48V(0.6A)(POE 1 Gbps) (Selectable)+1*15V(1.5A)/24V(1A) POE(Selectable)
3)2*15V(1.5A)/24V(1A) POE(Selectable) |
Efficiency |
AC mode:>85%,Battery mode:>90% |
battery size |
18650/21700/32700 |
18650/21700/32700 |
18650/21700/32700 |
18650/21700/32700 |
battery type |
Lithium-ion battery/LiFePO4 battery |
battery capacity |
8000-20800mah |
8000-48000mah |
8000-48000mah |
8000-48000mah |
battery numbers |
4/8 |
4/8 |
4/8 |
4/8 |
Material |
ABS |
protection function |
Over-charge, Over-discharge, Over-current, overload, over-temperature,short circuit |
operating Temperature |
0℃~40℃ |
Storage Temperature |
-10℃-50℃ |
humidity |
10%-90%RH |
altitude |
<3000m |
Noise level |
<45db |
Product Dimensions |
180*130*64mm |
214*158.5*86mm |
214*158.5*86mm |
214*158.5*86mm |
package size |
196*202*73mm |
230*230*95mm |
230*230*95mm |
230*230*95mm |
Net weight |
1.27(max) |
1.85kg(max) |
1.88kg(max) |
1.9kg(max) |
Gross weight |
1.32(max) |
2.6kg(max) |
2.63kg(max) |
2.65kg(max) |
| Features:
- 50KW single power module in 3U
- N+1or N+X parallel redundancy for power guarantee
- Supports horizontal expansion by 1+1 cabinet paralleloperation.
- Hot-swappable modular design decreases MTTR
- High scalability
- Built-in maintenance bypass switch for easy maintenance without interruptible
- High efficiency double conversion online UPS
- Flexible battery configuration and adjustable charging current
- High overload capability
- Power walk-in function
- Built-in dynamic password protection
- Built-in ultra communication slot
Specifications:
MODEL |
RM Plus 300K |
RM Plus 350K |
RM Plus 400K |
RM Plus 500K |
Phase |
3 Phase in / 3 Phase out |
Cabinet Capacity* |
300 KW |
350 KW |
400KW |
500KW |
Battery Type |
Extemal Battery |
One Power Module Capacity |
50KVA/50KW |
Max. Power Module No. |
6 |
7 |
8 |
10 |
INPUT |
Nominal Voltage |
3×380/400/415 VAC (3Ph+N) |
Voltage Range |
’-20%~+15% |
Nominal Frequency |
50/60Hz(Auto Sensing) |
Frequency Range |
40Hz~70Hz |
Power Factor |
>0.99 @100% Load, >0.98@50% Load |
Harmonic Distortion (THDi) |
<4% @ 100% load |
OUTPUT |
Nominal Voltage |
3×380/400/415 VAC (3Ph+N) |
Voltage Regulation(Steady State) |
≤ ±1% Typical (balanced load); ~≤ ±2% Typical (unbalanced load) |
Nominal Frequency |
50/60Hz |
Frequency Range(Synchronized) |
46Hz~54Hz or 56Hz~64Hz |
Overload Capability |
1 hour for ≤110%,10 mins for 111%~125%,1 min for 126%~150% and 200ms for >150% |
Haronic Distortion |
≤2% THD (Linear Load); ≤4% THD (Non-linear Load) |
Eficiency |
95.50% |
BATTERY / CHARGER |
Nominal Voltage |
‘+/- 192V~+/- 240V (Selectable) |
Maximum Voltage |
’+/- 240V (12V×40PCS) |
Minimum Voltage |
‘+/- 192V(12V×32PCS) |
Floating Charge Voltage |
2.28V/Cell (2.25~2.33 Selectable) |
Boost Charging Voltage |
2.35V/Cell |
Temperature Compensation |
Yes |
Maximum Charging Current
(Per Power Module) |
12A (Adjustable) |
PHYSICAL |
Cabinet Dimension (DxWxH)mm |
1065x600x2000 |
1065x600x2000 |
1065x1000x2000 |
1065x1000x2000 |
Net Weight (Kg) |
545 |
654 |
932 |
1020 |
Power Module (PM-50) Net Weight |
44KGS |
ENVIRONMENT |
Operating Temperature |
0~40℃ |
Relative Humidity |
0~95% non-condensing |
Altitude* |
<1000m for Nominal power |
IP Protection |
IP 20 |
MANAGEMENT |
Smart RS-232/USB |
Supports Windows⑧ Family, Linux and MAC |
Optional SNMP |
Power management from SNMP manager and web browser |
STANDARDS |
Safety |
IEC/EN 62040-1 |
EMC |
IEC/EN 62040-2 Category C3 |
|
Reviews
There are no reviews yet.