Single Phase High Frequency Online UPS VT Series 6KVA-20KVA

$0.00

Shipped From Abroad

Features:
  • True Double conversion Technology
  • DSP digital control technology enable UPS more stable performance.
  • Three Level inverter control technology
  • Large screen LCD display
  • N+X Parallel Redundancy function (3 units parallel)
  • EPO emergency stop function
  • Smart expansion Slots (optional)
  • Support Generator
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130139-26
Brands:: Reeco Power

Description

Features:
  • True Double conversion Technology
  • DSP digital control technology enable UPS more stable performance.
  • Three Level inverter control technology
  • Large screen LCD display
  • N+X Parallel Redundancy function (3 units parallel)
  • EPO emergency stop function
  • Smart expansion Slots (optional)
  • Support Generator

 

Applications:
  • Mammogram
  • Ultrasound Equipments
  • Radiology rooms

 

Technical Specifications
Model VT6K VT6KL VT10K VT10KL 31VT10KL 31VT15KL 31VT20KL
Capacity 6KVA/5400W 10KVA/9000W 15KVA/13.5KW 20KVA/18KW
Input Nominal Voltage 220/230/240Vac 380/400/415Vac
Voltage Range 120-275VAC(1P2W+G) 207-475VAC(3P4W+G)
Current 31A (max) 50A(max) 50A (max) 75A(max) 100A(max)
Frequency 46-54Hz Synchronous mains power; 50Hz( Frequency Range 40-46Hz ~54-60Hz);50Hz(Battery mode)
Power Factor ≥0.99·
Output Voltage 220/230/240±2%Vac (1P2W+G)
Frequency 50/60 Hz(adjustable)
50/60Hz± 5% (Line mode)
50/60Hz ± 0.05Hz ( Battery mode)
Current 27.3A 45A 68A 91A
Power Factor 0.9
Waveform Pure Sine Wave
Waveform Distortion Line load <2% Line load <3%
Back-up Time Full Load ≥7′ Depends on external batteries bank’s Capacity ≥5′ Depends on external batteries bank’s Capacity
Half Load ≥20 ≥13′
Battery Nominal Voltage 192/240Vdc
Transfer Time 0ms
Overload Capacity 105%±5%< Load<125%±5% :1 min transfer to bypass
125% ±5% < Load<135 % ±5 % :30s transfer to bypass
Load > 135 % ± 5 %: 300s transfer to bypass
Communication SNMP,RS-232,USB+lntelligent Slot
Operating Environment Temperature 0°C~40°C
Humidity 15%~90%
Dimension Width (mm) 260 260 260 260 260
Depth (mm) 560 533 560 533 560
Height (mm) 717 501 717 501 717
Net Weight(Kg) 55 12.2 62 21 23 32 33

Reviews

There are no reviews yet.

Be the first to review “Single Phase High Frequency Online UPS VT Series 6KVA-20KVA”

Your email address will not be published. Required fields are marked *

Quick Comparison

Single Phase High Frequency Online UPS VT Series 6KVA-20KVA remove3 Phase High Frequency Online UPS removePortable Power Station PS Series 2200W removeOPzV Tubular Gel Battery 60AH-3000AH removePortable Power Station PX Series 1000W remove3 Phase Low Frequency Solar Inverter DX Series remove
NameSingle Phase High Frequency Online UPS VT Series 6KVA-20KVA remove3 Phase High Frequency Online UPS removePortable Power Station PS Series 2200W removeOPzV Tubular Gel Battery 60AH-3000AH removePortable Power Station PX Series 1000W remove3 Phase Low Frequency Solar Inverter DX Series remove
Image
SKUSF1033560130139-26SF1033560130139-1SF1033560130139-22SF1033560130139-18SF1033560130139-23SF1033560130139-5
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
Features:
  • True Double conversion Technology
  • DSP digital control technology enable UPS more stable performance.
  • Three Level inverter control technology
  • Large screen LCD display
  • N+X Parallel Redundancy function (3 units parallel)
  • EPO emergency stop function
  • Smart expansion Slots (optional)
  • Support Generator
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad Features:
  • DSP digital control technology enables UPS more stable performance-+
  • Environment friendly eco-designed
  • Active input power factor correction
  • Wide range of input voltage and frequency
  • Zero power switch delay
  • Adaptive Load Management.
  • Sufficient Expansion Slots: USB ,RS485 ,AS400 SNMP cards(Optional)
  • Support the generator
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Features:
  • True Double conversion Technology
  • DSP digital control technology enable UPS more stable performance.
  • Three Level inverter control technology
  • Large screen LCD display
  • N+X Parallel Redundancy function (3 units parallel)
  • EPO emergency stop function
  • Smart expansion Slots (optional)
  • Support Generator
 
Applications:
  • Mammogram
  • Ultrasound Equipments
  • Radiology rooms
 
Technical Specifications
Model VT6K VT6KL VT10K VT10KL 31VT10KL 31VT15KL 31VT20KL
Capacity 6KVA/5400W 10KVA/9000W 15KVA/13.5KW 20KVA/18KW
Input Nominal Voltage 220/230/240Vac 380/400/415Vac
Voltage Range 120-275VAC(1P2W+G) 207-475VAC(3P4W+G)
Current 31A (max) 50A(max) 50A (max) 75A(max) 100A(max)
Frequency 46-54Hz Synchronous mains power; 50Hz( Frequency Range 40-46Hz ~54-60Hz);50Hz(Battery mode)
Power Factor ≥0.99·
Output Voltage 220/230/240±2%Vac (1P2W+G)
Frequency 50/60 Hz(adjustable) 50/60Hz± 5% (Line mode) 50/60Hz ± 0.05Hz ( Battery mode)
Current 27.3A 45A 68A 91A
Power Factor 0.9
Waveform Pure Sine Wave
Waveform Distortion Line load <2% Line load <3%
Back-up Time Full Load ≥7′ Depends on external batteries bank’s Capacity ≥5′ Depends on external batteries bank’s Capacity
Half Load ≥20 ≥13′
Battery Nominal Voltage 192/240Vdc
Transfer Time 0ms
Overload Capacity 105%±5%< Load<125%±5% :1 min transfer to bypass 125% ±5% < Load<135 % ±5 % :30s transfer to bypass Load > 135 % ± 5 %: 300s transfer to bypass
Communication SNMP,RS-232,USB+lntelligent Slot
Operating Environment Temperature 0°C~40°C
Humidity 15%~90%
Dimension Width (mm) 260 260 260 260 260
Depth (mm) 560 533 560 533 560
Height (mm) 717 501 717 501 717
Net Weight(Kg) 55 12.2 62 21 23 32 33
Features:
  • DSP digital control technology enables UPS more stable performance-+
  • Environment friendly eco-designed
  • Active input power factor correction
  • Wide range of input voltage and frequency
  • Zero power switch delay
  • Adaptive Load Management.
  • Sufficient Expansion Slots: USB ,RS485 ,AS400 SNMP cards(Optional)
  • Support the generator
 
Specifications:
Model 33VT 10K 33VT 10KL 33VT 20K 33VT 20KL 33VT 30KL 33VT 40KL
Capacity 10KVA/9000W 20KVA/18KW 30KVA/27KW 40KVA/36KW
Input Nominal Voltage 380/400/415Vac
Voltage Range 207-475VAC(3P4W+G)
Current 14A 28A 42A 67A
Frequency 40-70Hz (Adjustable)
Power Factor ≥0.99
Output Voltage 380VAC 1±1% (3P4W+G)
Frequency 46-54Hz Synchronous mains power; 50Hz( Frequency Range 40-46Hz -54-60Hz);50Hz(Battery mode)
Current 15A 30A 45A 61A
Power Factor 0.9
Crest Factor 3:1
THD Line load <3%
Chrage Current 5.5A 1A 7.5A 1A 5.5A
Battery Nominal Voltage 192VDC ±192VDC
Transfer Time 0ms
Overload Capacity 105%±5%< Load<125%±5% :1 min transfer to bypass 125% ±5% < Load<135 % ±5 % :30s transfer to bypass Load > 135 % ± 5 %: 300s transfer to bypass
Communication SNMP,RS-232,USB+lntelligent Slot
Operating Environment Temperature 0°C~40°C
Humidity 20%~95%
Dimension Width (mm) 260 260 260 260
Depth (mm) 560 533 710 560
Height (mm) 717 501 717 717
Net Weight(Kg) 26 72 57.5 98 58.5 62
Features:
  • Capacity: 2200W 2048Wh /640000mAh
  • Input AC Output Power:Rated Power 2400W Peak Power 4800W
  • Input AC Charging:AC100~125V/AC174~264V Bidirectional Inverter 1400W Max
  • Input Car Charging:DC12V~24V/10A 240W Max
  • Input Solar Charging:DC16V~60V/10A 500W Max
  • Output Voltage:230VAC±10%/110VAC±10%
  • Output Frequency: 50Hz±5%/60Hz±5%
  • USB Output:2*QC18W+PD27W+PD100W Max
  • DC Output:1*Cigarette Lighter 12.8V/12A Max+2*DC5521 Rated Output 12.8V/5A Max
  • Output Waveform:Pure Sine Wave
  • LED:3 Levels(H/M/L)+SOS
  • UPS Function:Support ; Battery Expandable: Support
 
Applications:
  • Mammogram
  • Ultrasound Equipments
  • Radiology rooms
Features:
  • OPzV Tubular Gel Battery ( solid-state) 60AH-3000AH
  • Voltage class: 12V/2V
  • Capacity range: 60Ah~3000Ah

OPzV batteries offer high capacity reserve power and true deep cycling performance. With a design life of 20 years and a maintenance-free operation, OPzV battery are perfect for regions with an unstable supply of electricity. OPzV battery are also completely spill-proof, which makes them safe to install anywhere, even in remote environments with minimal supervision.

 
Technical Specifications
Model Nominal Voltage Capacity Dimension Terminal
C10/1.80VPC (Ah) Length Width Height Total Height
(V) mm mm mm mm
OPzV6-200 6 200 322 177.5 226 231 F16(M8) F14(M8)
OPzV12-60 12 60 260 169 211 216  F11(M6)
OPzV12-80 12 80 328 172 215 220  F12(M8)
OPzV12-100 12 100 407 177 225 225  F12(M8)
OPzV12-120 12 120 483 170 241 241  F12(M8)
OPzV12-140 12 140 532 207 214 219  F12(M8)
OPzV12-160 12 160 532 207 214 219 F12(M8)
OPzV12-180 12 180 522 240 219 224  F10(M8)
OPzV12-200 12 200 521 268 220 225 F14(M8)
OPzV2-200 2 200 103 206 355 390 F10(M8)
OPzV2-250 2 250 124 206 355 390 F10(M8)
OPzV2-300 2 300 145 206 355 390 F10(M8)
OPzV2-350 2 350 124 206 470 505 F10(M8)
OPzV2-420 2 420 145 206 470 505 F10(M8)
OPzV2-500 2 490 166 206 470 505 F10(M8)
OPzV2-770 2 770 210 254 470 505 F10(M8)
OPzV2-600 2 600 145 206 645 680 F10(M8)
OPzV2-800 2 800 191 210 645 680 F10(M8)
OPzV2-1000 2 1000 233 210 645 680 F10(M8)
OPzV2-1200 2 1200 276 210 645 680 F10(M8)
OPzV2-1500 2 1500 275 210 795 830 F10(M8)
OPzV2-2000 2 2000 399 214 770 805 F10(M8)
OPzV2-2500 2 2500 487 212 770 805 F10(M8)
OPzV2-3000 2 3000 576 212 770 805 F10(M8)
Features:
  • Rated Power: 1000W
  • Rated Capacity: 932.4wh
  • Standard Capacity: 3.7V/252000mah
  • Overload Protecion: 1050+40W
  • AC Output: AC 110V+10%/60HZ 230V+10%/50HZ
  • Output Wave: Pure sine wave
  • USB Output: QC 18W*2
  • Type-c Output: PD 60W*2
  • Cigarret Lighter Output: 14V/8A
  • DC5525 Output: 14V/8A
  • Wireless Charging: 15W
  • Charging Input: 12-26 V/150W Max
  • WorkingTemperature: -10-40 °C
  • Weight(Net Weight): 8. 2kg
  • Weight(With Accessories): 10.2kg
  • Dimension: 345*227*203mm
 
Applications:
  • Mammogram
  • Ultrasound Equipments
  • Radiology rooms
 
Features:
Three Phase Hybrid Solar Inverter Off grid three phase solar hybrid inverter with pwm/mppt can be used in single-phase and three-phase ac load with total power not exceeding  100kva/120kva/125kva/150kva/160kva,384vdc to 380vac. •Pure sine wave output. •Low DC voltage, saving system cost. •Three phase solar inverter with built-in PWM or MPPT charge controller. •AC charge current 0-45A adjustable. •Wide LCD screen, clearly and precisely shows icon data. •100%imbalance loading design, 3 times peak power. •Setting different working modes based on variable usage requirements. •DC first/AC first optional. •Various communication ports and remote controls  
Specifications
MODEL DX100KVA DX120KVA DX125KVA DX150KVA DX160KVA 190KVA 200KVA
Rated Power 80KW 96KW 100KW 120KW 128KW 150KW 160KW
Peak Power(20ms) 240KVA 288KVA 300KVA 360KVA 384KVA 450KVA 480KVA
Start Motor 40HP 50HP 50HP 60HP 60HP 80HP 80HP
Battery Voltage 384VDC
Size(L*W*Hmm) 875*720*1380 1123*900*1605
Packing Size(L*W*Hmm) 980*825*1560 1185*960*1750
N.W.(kg) 512 592 612 612 642 705 755
G.W.(kg)(Wooden Packing) 552 632 652 652 692 755 805
INPUT DC Input Voltage Range 10.5VDC-15VDC(Single battery voltage)
AC Input Voltage Range 380Vac/400Vac±10%(customized 190Vac/200Vac)
AC Input Frequency Range 45Hz-55Hz(50Hz)/ 55Hz-65Hz(60Hz)
Max AC charging current 0-45A(Depending on the model)
AC charging method Three-stage (constant current, constant voltage, floating charge)
Phase 3 PHASE
OUTPUT Efficiency(Battery Mode) ≥85%
Output Voltage(Battery Mode) 380Vac/400Vac±10%(customized 190Vac/200Vac)
Output Frequency(Battery Mode) 50/60Hz ±1%
Output Wave(Battery Mode) Pure Sine Wave
Output waveform distortion Linear load≤3%
Efficiency(AC Mode) >99%
Output Voltage(AC Mode) Conforming to AC input
Output Frequency(AC Mode) Conforming to AC input
No load loss(Battery Mode) ≤1% rated power
No load loss(AC Mode) ≤2%rated power( charger does not work in AC mode)
No load loss (Energy saving Mode) ≤10W
Phase 3 PHASE
BATTERY VRLA Battery Charge Voltage :13.8V; Float Voltage:13.7V(Single battery voltage)
Customize battery Charging and discharging parameters of different types of batteries can be customized according to user requirements
(charging and discharging parameters of different types of batteries can be set through the operation panel)
Protection Battery undervoltage alarm 11V(Single battery voltage)
Battery undervoltage protection 10.5V(Single battery voltage)
Battery overvoltage alarm 15V(Single battery voltage)
Battery overvoltage protection 17V(Single battery voltage)
Battery overvoltage recovery voltage 14.5V(Single battery voltage)
Overload power protection Automatic protection (battery mode), circuit breaker or insurance (AC mode)
Inverter output short circuit protection Automatic protection (battery mode), circuit breaker or insurance (AC mode)
Temperature protection >90°C(Shut down output)
Alarm A Normal working condition, buzzer has no alarm sound
B Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection
C When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal
Inside Solar controller Charging Mode MPPT or PWM
(Optional) Charging current PWM: 100A-200A / MPPT: 50A/100A
PV Input Voltage Range PWM: 480V-704V / MPPT: 480V-640V
Max PV Input Voltage(Voc) PWM: 750V / MPPT: 800V
(At the lowest temperature)
PV Array Maximum Power PWM: 44.8KW(100A)/33.6KW*2(150A)/44.8KW*2(200A)) / (MPPT: 22.4KW(50A)/22.4KW*2(100A)
Standby loss ≤3W
Maximum conversion efficiency >95%
Working Mode Battery First/AC First/Saving Energy Mode
Transfer Time ≤4ms
Display LCD
Thermal method Forced Air Cooling
Communication(Optional) RS485/APP(WIFI monitoring or GPRS monitoring)
Environment Operating temperature -10℃~40℃
Storage temperature -15℃~60℃
Noise 2000m(More than derating)
Elevation ≤65dB
Humidity 0%~95% ,No condensation
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar