Single Phase Low Frequency Power Inverter VK Series 300W-1200W

$0.00

Shipped From Abroad

Features:
  • Pure sine wave output
  • AC Charging current 15A
  • High-low voltage protection
  • Against overload, short-circuit Protection
  • Over voltage,battery reverse connection(optional)
  • Under-voltage and over-temperature protection
  • Selectable battery priority or utility priority
  • Have UPS function and AC charger function

 

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130139-29
Brands:: Reeco Power

Description

Features:
  • Pure sine wave output
  • AC Charging current 15A
  • High-low voltage protection
  • Against overload, short-circuit Protection
  • Over voltage,battery reverse connection(optional)
  • Under-voltage and over-temperature protection
  • Selectable battery priority or utility priority
  • Have UPS function and AC charger function
Applications:
  • Mammogram
  • Ultrasound Equipments
  • Radiology rooms

 

Technical Specifications
MODEL VK300W VK500W VK700W VK800W VK1000W VK1200W
Rated Power 300W 500W 700W 800W 1000W 1200W
Peak Power 600W 1000W 1400W 1600W 2000W 2400W
AC input voltage range 73V-135VAC(110VAC/120VAC) 145V-275VAC(220VAC /230VAC )
Input frequency range 45-65HZ
Battery voltage 12VDC /24VDC
DC voltage 12VDC:10.5 -15VDC/24VDC:21-30VDC
Battery undervoltage alarm 10.5VDC /21VDC
Battery undervoltage protection 10VDC /20VDC
Battery overvoltage protection 17V±0.5V /34V±0.5V
Voltage overvoltage alarm 15V-16VDC/30V-32VDC
Overload protection Rated power of 110% or more
Temperature protection ≥85 °C alarm, ≥90 °C off the machine
Inverter output voltage 110VAC/120VAC/ 220VAC/230VAC ±2%
Inverter output frequency 50/60HZ±10%
Inverter output waveform pure sine wave
AC output voltage range output 110VAC/120VAC/ 220VAC/230VAC ±10%
Output frequency range Automatic tracking
Conversion time <5ms
Cooling method Intelligent fan control, ≤42 °C fan slow working , ≥45 °C fan high working .
AC Charging current 15A
Working mode selection Free to choose(SET)
01: AC priority/Citypower priority:
When city power is available, the inverter will work AC output, city power will supply power to appliances.The city power charges power to battery. When city power failed, will use battery power to take the appliances.02: energy saving mode
load power ≤10% off the machine, ≥11% -100% turn on 

03: Battery priority
When it have has battery power, battery supply power to the appliances. When battery voltage ≤10.5V, inverter will automatic use city power to take the appliances, When battery voltage reach 13V inverter will use use battery power

External Size(mm) DxWxH 300*290*150mm
Packing Size(mm) DxWxH 350*350*405(2pcs)
Net Weight(KG) 5 6 6.5 7.5 8.5 9.5
Gross Weight(KG) 12 14 15 17 19 21

Reviews

There are no reviews yet.

Be the first to review “Single Phase Low Frequency Power Inverter VK Series 300W-1200W”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsSingle Phase Low Frequency Power Inverter VK Series 300W-1200W removePortable Power Station PS Series 2200W removePortable Power Station PX Series 1000W remove3 Phase Low Frequency Online UPS LD33 Series removeLead Acid Gel Battery 33AH-250AH removeLine Interactive UPS DP Series 600VA-3000VA remove
NameSingle Phase Low Frequency Power Inverter VK Series 300W-1200W removePortable Power Station PS Series 2200W removePortable Power Station PX Series 1000W remove3 Phase Low Frequency Online UPS LD33 Series removeLead Acid Gel Battery 33AH-250AH removeLine Interactive UPS DP Series 600VA-3000VA remove
Image
SKUSF1033560130139-29SF1033560130139-22SF1033560130139-23SF1033560130139-3SF1033560130139-14SF1033560130139-17
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
Features:
  • Pure sine wave output
  • AC Charging current 15A
  • High-low voltage protection
  • Against overload, short-circuit Protection
  • Over voltage,battery reverse connection(optional)
  • Under-voltage and over-temperature protection
  • Selectable battery priority or utility priority
  • Have UPS function and AC charger function
 
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Features:
  • Valve sealed design, no free electrolyte, Maintenance -free
  • Designed floating service life:15 years @ 25 °C/68 °F.
  • Wide operating temperature range from -15°C to 35°C
  • Nanometer gel electrolytes eliminate the acid stratification and prolong cycle life
  • Low self-discharge rate: ≤3%/month.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Features:
  • Intelligent CPU control
  • Automatic power on when the the main power recovers
  • Cold start function
  • Power off charging function
  • USB/RS232/RJ-11/RJ-45 communication port (optional)
  • Offering LED and LCD panels for selection
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Features:
  • Pure sine wave output
  • AC Charging current 15A
  • High-low voltage protection
  • Against overload, short-circuit Protection
  • Over voltage,battery reverse connection(optional)
  • Under-voltage and over-temperature protection
  • Selectable battery priority or utility priority
  • Have UPS function and AC charger function
Applications:
  • Mammogram
  • Ultrasound Equipments
  • Radiology rooms
 
Technical Specifications
MODEL VK300W VK500W VK700W VK800W VK1000W VK1200W
Rated Power 300W 500W 700W 800W 1000W 1200W
Peak Power 600W 1000W 1400W 1600W 2000W 2400W
AC input voltage range 73V-135VAC(110VAC/120VAC) 145V-275VAC(220VAC /230VAC )
Input frequency range 45-65HZ
Battery voltage 12VDC /24VDC
DC voltage 12VDC:10.5 -15VDC/24VDC:21-30VDC
Battery undervoltage alarm 10.5VDC /21VDC
Battery undervoltage protection 10VDC /20VDC
Battery overvoltage protection 17V±0.5V /34V±0.5V
Voltage overvoltage alarm 15V-16VDC/30V-32VDC
Overload protection Rated power of 110% or more
Temperature protection ≥85 °C alarm, ≥90 °C off the machine
Inverter output voltage 110VAC/120VAC/ 220VAC/230VAC ±2%
Inverter output frequency 50/60HZ±10%
Inverter output waveform pure sine wave
AC output voltage range output 110VAC/120VAC/ 220VAC/230VAC ±10%
Output frequency range Automatic tracking
Conversion time <5ms
Cooling method Intelligent fan control, ≤42 °C fan slow working , ≥45 °C fan high working .
AC Charging current 15A
Working mode selection Free to choose(SET) 01: AC priority/Citypower priority: When city power is available, the inverter will work AC output, city power will supply power to appliances.The city power charges power to battery. When city power failed, will use battery power to take the appliances.02: energy saving mode load power ≤10% off the machine, ≥11% -100% turn on  03: Battery priority When it have has battery power, battery supply power to the appliances. When battery voltage ≤10.5V, inverter will automatic use city power to take the appliances, When battery voltage reach 13V inverter will use use battery power
External Size(mm) DxWxH 300*290*150mm
Packing Size(mm) DxWxH 350*350*405(2pcs)
Net Weight(KG) 5 6 6.5 7.5 8.5 9.5
Gross Weight(KG) 12 14 15 17 19 21
Features:
  • Capacity: 2200W 2048Wh /640000mAh
  • Input AC Output Power:Rated Power 2400W Peak Power 4800W
  • Input AC Charging:AC100~125V/AC174~264V Bidirectional Inverter 1400W Max
  • Input Car Charging:DC12V~24V/10A 240W Max
  • Input Solar Charging:DC16V~60V/10A 500W Max
  • Output Voltage:230VAC±10%/110VAC±10%
  • Output Frequency: 50Hz±5%/60Hz±5%
  • USB Output:2*QC18W+PD27W+PD100W Max
  • DC Output:1*Cigarette Lighter 12.8V/12A Max+2*DC5521 Rated Output 12.8V/5A Max
  • Output Waveform:Pure Sine Wave
  • LED:3 Levels(H/M/L)+SOS
  • UPS Function:Support ; Battery Expandable: Support
 
Applications:
  • Mammogram
  • Ultrasound Equipments
  • Radiology rooms
Features:
  • Rated Power: 1000W
  • Rated Capacity: 932.4wh
  • Standard Capacity: 3.7V/252000mah
  • Overload Protecion: 1050+40W
  • AC Output: AC 110V+10%/60HZ 230V+10%/50HZ
  • Output Wave: Pure sine wave
  • USB Output: QC 18W*2
  • Type-c Output: PD 60W*2
  • Cigarret Lighter Output: 14V/8A
  • DC5525 Output: 14V/8A
  • Wireless Charging: 15W
  • Charging Input: 12-26 V/150W Max
  • WorkingTemperature: -10-40 °C
  • Weight(Net Weight): 8. 2kg
  • Weight(With Accessories): 10.2kg
  • Dimension: 345*227*203mm
 
Applications:
  • Mammogram
  • Ultrasound Equipments
  • Radiology rooms
 
Description
HIGH INTELLIGENCE AND RELIABLE POWER SUPPLY IGBT Technology Full microprocessor control with no-break static and manual bypasses. Online double conversion technology (VFl) with isolation transformer on theinverter output. Extremely high short-circuit current to ensure compatibility with the most diffificult transformer applications (lighting, drives and industrial processes) and an isolation transformer on the inverter output. Compatibled with Watch & Save 3000 software as standard and can be remotely monitored using the Power NetGuard system from anywhere in the world. SIMPLE TO INSTALL Capability to install the UPS into any distribution system(neutral not required on rectifier input). Capability to separate the rectifier/bypass power networks and to power them from two separate sources, without Galvanic isolation(Necessary on UPS without an output transformer MAXIMUM BATTERY CARE Battery deep discharge protection; Temperature compensating charger; Built-in automatic and manual battery test feature. OTHER CHARACTERISTICS 0.8/0.9 power factor suitable for powering ICT and lndustrial loads. BACK FEED protection: to avoid energy feeding back into the mains supply cause a fault occur. MAXIMUM RELIABILITY AND AVAILABILITY Connect up to 6 units in parallel or N+1 redundancy, even of different power ratings. The UPS continue to work in parallel even if one of theinterconnecting communication cables is disconnected(CLOSED LOOP) LOW CONSUMPTION LEVELS LF33 Series UPS can achieve efficiencies >98% thanks to selectable Economy Mode which can be used in stable electrical environments to provide power supply continuity when the mains fail. ADVANCE COMMUNICATION: RS485/RS232/Dry Contact/SNMP(Optional)  
Specifications
Model 10KVA 20KVA 30KVA 40KVA 60KVA 80KVA 100KVA 120KVA 160KVA 200KVA 250KVA 300KVA 400KVA 500KVA 600KVA
Capacity 8KW 16 KW 24 KW 32 KW  48 KW 64 KW  80 KW 96 KW 128 KW 160 KW 200KW 240KW 320KW 400KW  480KW
INPUT
Rated voltage 400 VAC  Three-Phase
Voltage range 380/400/415VAC(+25%,Can be set through the LCD panel)
Frequency range 40-70Hz(Automatically select synchronization range according to grid frequency)
Range(HZ) 50±5%(±10%) Bypass synchronization tracking
Rectifying pulse number 6 pulse rectification 6/12 pulse rectification 12 pulse rectifier
Phase system 3φ4W+PE(Three phase five wire system)
Battery voltage 384VDC 480VDC
Battery Quantity Standard with 32 Cells(30~34, can be set through the LCD panel)  Standard 40 Cells(38~42 knots,can be set by LCD panel)
OUTPUT
Power factor 0.8/0.9 (Optional)
Voltage(V) L-N: 220±1%   L-L: 380±1%
Three-phase 100% load unbalance voltage stability ≤2%,Allow 100% imbalance
Frequency(HZ) Normal power, tracking the frequency of power, Grid abnormal. 50±0.2%
Transfer time(ms) 0ms
Parallel operation mode (parallel type) Max 8 Parallel
Waveform distortion Linear loadTHD<3% ; Nonlinear loadTHD<5%
Overload capacity 125% full load for 10 minutes, maintain 150 % full load for 1 minute and then switch to bypass power supply, after reducing the loadcan automatically restore the inverter
Crest factor 3:1
Others
Index Standard with no transfer time maintenance bypass switch
Communication function RS232/RS485/Dry Contact/SNMP (Optional)
Panel display LED displays working status and fault indication; LCD displays three-phase input voltage, input frequency, three-phase output voltage, load,battery voltage, battery charge and discharge current, etc
Display  7″ Touchable LCD screen display
The audio noise(dB) <65(within 1 meter)
Alarm function Battery low voltage, abnormal power supply, overload, UPS failure, over temperature protection
Protection Input over voltage, battery under voltage, overload, short circuit, over temperature protection
Cooling way Forced cooling
Operating temperature 0℃ to  ~ 40℃
Humidity 0~95%, non-condensing
electromagnetic compatibility Conform GB7260.2
Size(W*D*H)(mm) 540*660*1135 1100*800*1800 800*800*1900 1200*850*1900 2600*1100*2000
Weight 196     233 276 329 461 547.5 643 754 1375
Features:
  • Valve sealed design, no free electrolyte, Maintenance -free
  • Designed floating service life:15 years @ 25 °C/68 °F.
  • Wide operating temperature range from -15°C to 35°C
  • Nanometer gel electrolytes eliminate the acid stratification and prolong cycle life
  • Low self-discharge rate: ≤3%/month.
 
Application
  • UPS Systems
  • Portable Equipment
  • Renewable Energy Systems
  • Electric Utilities
  • Outdoor control Equipment
  • Railroad Utilities
  • Telecom Systems
 
Technical Specifications
Model Nominal Voltage Capacity Dimension LXWXH (mm) Total Height (mm) Weight (KG/IBS) Terminal
VG12-33 12V 33AH 195 130 167 167 10 22.05 M6
VG12-35 12V 35AH 195 130 167 167 11.5 25.35 M6
VG12-38 12V 38AH 197 165 172 172 12.5 27.56 M6
VG12-40 12V 40AH 197 165 172 172 13.2 29.1 M6
VG12-45 12V 45AH 197 165 172 172 15 33.07 M6
VG12-50 12V 50AH 229 138 205 208 15.5 34.17 M6
VG12-55 12V 55AH 229 138 205 208 16.5 36.38 M6
VG12-65 12V 65AH 350 166 175 175 21 46.3 M8
VG12-70 12V 70AH 260 168 208 211 21.8 48.06 M8
VG12-80 12V 80AH 260 168 208 211 24 52.91 M8
VG12-90 12V 90AH 330 171 216 219 27 59.52 M8
VG12-100 12V 100AH 330 171 216 219 29.5 65.04 M8
VG12-120 12V 120AH 407 173 237 237 35 77.16 M8
VG12-150 12V 150AH 484 170 241 241 45 99.21 M8
VG12-200 12V 200AH 522 240 219 222 61.5 135.58 M8
VG12-250 12V 250AH 520 268 220 223 71 156.53 M8
Features:
  • Intelligent CPU control
  • Automatic power on when the the main power recovers
  • Cold start function
  • Power off charging function
  • USB/RS232/RJ-11/RJ-45 communication port (optional)
  • Offering LED and LCD panels for selection
 
Application:
  • Personal Computer
  • Printer
  • POS(Point of sales)Terminals
  • Security System
  • Fax Machine
  • Modem, WiFi Router
 
Technical Specifications:
 
Model DP600 DP1000 DP1200 DP2000 DP3000
Capacity 600VA/360W 1000VA/600W 1200VA/720W 2000VA/1200W 3000VA/1800W
INPUT
Voltage 110/120VAA or 220/230/240VAC
Voltage Range 67-137VAC/135-275VAC
Frequency Range 50Hz Or 60Hz(Auto-Sensing)
OUTPUT
Output Voltage 110/120VAA or 220/230/240VAC
AC Voltage Regulation ± 10%
Frequency Range (Batt. Mode) 50 HZ or 60 Hz ± 10%
Transfer Time Typical 6-10 ms
Waveform (Battery Mode) Simulated Sine Wave
BATTERY
Battery Voltage 12V/7AH*1 12V/9AH*1 12V/7AH*2 12V/9AH*2 12V/7AH*4
Charge Time 8 hours up to 80-90%
PROTECTION
Full Protection Auto Detection, discharge protection,output Short circuit, Over load, Battery low voltage protection
 Communication Port USB/RS232/RJ11/RJ45  (Optional)
Display LED/LCD
          Alarm
Battery Mode Every 4 Seconds one beep
Low Battery Capacity Every 1 Seconds one beep
Overload Every 1 Seconds one beep
Fault Keep beeping
ENVIRONMENT
Humidity 0-90% Rh @ 0-40℃ (Non-Condensing)
Noise Level 40dB
Dimension(mm) 320*90*140 330* 100*150 365*140*165 365*140*165 395*145*210
N.W.(kg) 5.2 6 10 12.6 21
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare