Features:

1) Output power factor: PF1.0
2) Rack/Tower Convertiable Design with manual roatatable LCD Screen.
3) Input voltate:110-300Vac
4) Output voltage:208/220/230/240Vac
5) Transfer time: AC to DC mode 0ms ; DC to bypass mode 4ms.
6) Output frequency: 50Hz/60Hz auto adjusted.
7)ECO Power Mode, High Efficiency up to 98.5%
8) Interferface: 1*USB, 1*RS232, 1*EPO, 1*SNMP card slot ( SNMP card needs to be purchased separately).
9)Protection: high/low voltage, over load, short circuit protection.

 

Technical Specifications
Model RM   1K RM1KL RM   2K RM   2KL RM   3K RM    3KL RM   6K RM   6KL RM   10K RM    10KL
Rated Capacity 1KVA/1KW 2KVA/2KW 3KVN/3KW 6KVA/6KW 10KVA/10KW
INPUT
Input Formats L+N+PE
Rated Input Voltage 208/220/230/240 VAC
Voltage Range 110-300VAC (110-176VAC,280-300VAC Power Limited)
Frequency Range 50/60Hz±6Hz,±10Hz(Setable)
Input Power Factor >0.99
Input Harmonic Distortion <1%THD(Linear Load),<5%THD(Non-linear Load)PF=0.8 <5%THD(Linear Load),<8%THD(Non-linear Load)PF=0.8
OUTPUT
Output Formats L+N+PE
Output Voltage 208 /220/230/240 VAC
Output Accuracy ±1%
Output Frequency AC Mode:Same as AC,Battery Mode:50160Hz±1%
Output Harmonic Distortion <1%THD(Linear Load),<3%THD(Non-linear Load)PF=0.8 <2%THD(Linear Load),<5%THD(Non-linear Load)PF=0.8
Output Power Factor 1.0
Transfer Time AC Mode to Battery Mode:0ms,Inverter Mode to Bypass Mode:4ms
Load Capacity AC Mode:         Battery  Mode
30min@102%~110%load    1min@102%~110%load
10min@110%~130%load 10s@110%~130%load
30s@130%~150%load   3s@130%~150%load
200ms@>150%load     200ms@>150%load
AC Mode:         Battery  Mode
30min@102%~110%load    10min@102%~110%load
10min@110%~130%load  1min@110%~130%load
30s@130%~150%load   10s@130%~150%load
500ms@>150%load     500ms@>150%load
MACHINE EFFICIENCY
AC Mode Maximum Efficiency 95.5%,Full Load Efficiency 95%
Battery Mode Full Load Efficiency 89.5@36VAC
Full Load Efficiency 89.5@24VAC
Full Load Eficiency 91.5@72VAC
Full Load Efficiency 91.5@48VAC
Full Load Efficiency 91.5@96VAC
Full Load Eficiency 91.5@72VAC
Maximum Efficiency 95.3%,Full Load Eficiency 94.8%(20pcs
Battery
BATTERY
Battery Quantity 7AH*2 36VDC 7Ah*4/7ah*6 DC
2
7Ah*4/7ah*6 96VDC 7AH*16 192VDC 7AH*16 192VDC
Backup Time Depend on User’s Requirement and Configuration
Charge Current Internal Battery Type:RM 1KVA-3KVA:1.0A (Default),1-12A Adjustable
Extemal Battery Type:RM 1KL-3KL:5.0A (Default),1-12A Adjustable.
1.0A(Default),1-12A Adjustable(PF=0.8,1-8A Adjustable)
WORKING ENVIRONMENT
Ambient Temperature 0~40℃
Ambient Humidity 20%-95%(No Condensation)
Storage Temperature -15~60°℃(Battery:0~40℃)
Altitude <1000m,Derating at above 1000m,Maximum 4000m,Refer to IEC62040
DISPLAY
LCD Working Mode/Load/Battery Power /Input /Output ect
Standard &Certification EN/IEC61000,EN/IEC62040,GB/T4943,YD/T1095,TLC ect
PHYSICAL
UPS Size (L*W*H) 438*88*385mm 438*88*505 438*88*385 UPS case size:438*88*470 mm;
Battery Pack size:438*88*690mm
Package Size
(L*W”H)
533*178*480mm 533*178*507mm 533*178*590mm 570*595*230mm
Net Weight(KG) 11.2 5.8 15 6.5 20.5 7.5 20.2 9.5 21.5 10.25
Gross Weight(KG) 12.0 6.5 17 9 22.5 9 21.5 11.5 23 11.2
COMUNICATION INTERFACE
Interface 1*USB,1*RS232,1*EPO

Reviews

There are no reviews yet.

Be the first to review “Single Phase Rack mount Online UPS RM Series”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsSingle Phase Rack mount Online UPS RM Series removeOPzV Tubular Gel Battery 60AH-3000AH remove3 Phase Low Frequency Online UPS LD31 Series remove3 Phase Low Frequency Online UPS LF33 Series removeHigh Frequency Modular UPS RM Pro Series remove3 Phase Low Frequency Solar Inverter DX Series remove
NameSingle Phase Rack mount Online UPS RM Series removeOPzV Tubular Gel Battery 60AH-3000AH remove3 Phase Low Frequency Online UPS LD31 Series remove3 Phase Low Frequency Online UPS LF33 Series removeHigh Frequency Modular UPS RM Pro Series remove3 Phase Low Frequency Solar Inverter DX Series remove
Image
SKUSF1033560130139-31SF1033560130139-18SF1033560130139-2SF1033560130139-4SF1033560130139-10SF1033560130139-5
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Features:
  • Optional 7 ” touch LCD
  • Online double-conversionDSP technology guarantees high reliability
  • True galvanic isolation transformer designControl designed to withstand all kinds of loads
  • Intelligent battery management to prolong battery lifecycle
  • Redundant fan design and independent ventilation enhance durable operation under harsh environment
  • Adiustable battery numbers
  • Accept dual-mains input
  • Parallel operation with up to 4 units ( option )
  • Variety of communication options available
  • Reverse phase frequency operation and supportsnon-neutral input
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Features:
  • 60KW single power module in 3U
  • N+1or N+X parallel redundancy for power guarantee
  • Supports horizontal expansion by 1+1 cabinet paralleloperation.
  • Hot-swappable modular design decreases MTTR
  • High scalability
  • Built-in maintenance bypass switch for easy maintenance without interruptible
  • High efficiency double conversion online UPS
  • Flexible battery configuration and adjustable charging current
  • High overload capability
  • Power walk-in function
  • Built-in dynamic password protection
  • Built-in ultra communication slot
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Features:
1) Output power factor: PF1.0 2) Rack/Tower Convertiable Design with manual roatatable LCD Screen. 3) Input voltate:110-300Vac 4) Output voltage:208/220/230/240Vac 5) Transfer time: AC to DC mode 0ms ; DC to bypass mode 4ms. 6) Output frequency: 50Hz/60Hz auto adjusted. 7)ECO Power Mode, High Efficiency up to 98.5% 8) Interferface: 1*USB, 1*RS232, 1*EPO, 1*SNMP card slot ( SNMP card needs to be purchased separately). 9)Protection: high/low voltage, over load, short circuit protection.  
Technical Specifications
Model RM   1K RM1KL RM   2K RM   2KL RM   3K RM    3KL RM   6K RM   6KL RM   10K RM    10KL
Rated Capacity 1KVA/1KW 2KVA/2KW 3KVN/3KW 6KVA/6KW 10KVA/10KW
INPUT
Input Formats L+N+PE
Rated Input Voltage 208/220/230/240 VAC
Voltage Range 110-300VAC (110-176VAC,280-300VAC Power Limited)
Frequency Range 50/60Hz±6Hz,±10Hz(Setable)
Input Power Factor >0.99
Input Harmonic Distortion <1%THD(Linear Load),<5%THD(Non-linear Load)PF=0.8 <5%THD(Linear Load),<8%THD(Non-linear Load)PF=0.8
OUTPUT
Output Formats L+N+PE
Output Voltage 208 /220/230/240 VAC
Output Accuracy ±1%
Output Frequency AC Mode:Same as AC,Battery Mode:50160Hz±1%
Output Harmonic Distortion <1%THD(Linear Load),<3%THD(Non-linear Load)PF=0.8 <2%THD(Linear Load),<5%THD(Non-linear Load)PF=0.8
Output Power Factor 1.0
Transfer Time AC Mode to Battery Mode:0ms,Inverter Mode to Bypass Mode:4ms
Load Capacity AC Mode:         Battery  Mode 30min@102%~110%load    1min@102%~110%load 10min@110%~130%load 10s@110%~130%load 30s@130%~150%load   3s@130%~150%load 200ms@>150%load     200ms@>150%load AC Mode:         Battery  Mode 30min@102%~110%load    10min@102%~110%load 10min@110%~130%load  1min@110%~130%load 30s@130%~150%load   10s@130%~150%load 500ms@>150%load     500ms@>150%load
MACHINE EFFICIENCY
AC Mode Maximum Efficiency 95.5%,Full Load Efficiency 95%
Battery Mode Full Load Efficiency 89.5@36VAC Full Load Efficiency 89.5@24VAC Full Load Eficiency 91.5@72VAC Full Load Efficiency 91.5@48VAC Full Load Efficiency 91.5@96VAC Full Load Eficiency 91.5@72VAC Maximum Efficiency 95.3%,Full Load Eficiency 94.8%(20pcs Battery
BATTERY
Battery Quantity 7AH*2 36VDC 7Ah*4/7ah*6 DC 2 7Ah*4/7ah*6 96VDC 7AH*16 192VDC 7AH*16 192VDC
Backup Time Depend on User’s Requirement and Configuration
Charge Current Internal Battery Type:RM 1KVA-3KVA:1.0A (Default),1-12A Adjustable Extemal Battery Type:RM 1KL-3KL:5.0A (Default),1-12A Adjustable. 1.0A(Default),1-12A Adjustable(PF=0.8,1-8A Adjustable)
WORKING ENVIRONMENT
Ambient Temperature 0~40℃
Ambient Humidity 20%-95%(No Condensation)
Storage Temperature -15~60°℃(Battery:0~40℃)
Altitude <1000m,Derating at above 1000m,Maximum 4000m,Refer to IEC62040
DISPLAY
LCD Working Mode/Load/Battery Power /Input /Output ect
Standard &Certification EN/IEC61000,EN/IEC62040,GB/T4943,YD/T1095,TLC ect
PHYSICAL
UPS Size (L*W*H) 438*88*385mm 438*88*505 438*88*385 UPS case size:438*88*470 mm; Battery Pack size:438*88*690mm
Package Size (L*W”H) 533*178*480mm 533*178*507mm 533*178*590mm 570*595*230mm
Net Weight(KG) 11.2 5.8 15 6.5 20.5 7.5 20.2 9.5 21.5 10.25
Gross Weight(KG) 12.0 6.5 17 9 22.5 9 21.5 11.5 23 11.2
COMUNICATION INTERFACE
Interface 1*USB,1*RS232,1*EPO
Features:
  • OPzV Tubular Gel Battery ( solid-state) 60AH-3000AH
  • Voltage class: 12V/2V
  • Capacity range: 60Ah~3000Ah

OPzV batteries offer high capacity reserve power and true deep cycling performance. With a design life of 20 years and a maintenance-free operation, OPzV battery are perfect for regions with an unstable supply of electricity. OPzV battery are also completely spill-proof, which makes them safe to install anywhere, even in remote environments with minimal supervision.

 
Technical Specifications
Model Nominal Voltage Capacity Dimension Terminal
C10/1.80VPC (Ah) Length Width Height Total Height
(V) mm mm mm mm
OPzV6-200 6 200 322 177.5 226 231 F16(M8) F14(M8)
OPzV12-60 12 60 260 169 211 216  F11(M6)
OPzV12-80 12 80 328 172 215 220  F12(M8)
OPzV12-100 12 100 407 177 225 225  F12(M8)
OPzV12-120 12 120 483 170 241 241  F12(M8)
OPzV12-140 12 140 532 207 214 219  F12(M8)
OPzV12-160 12 160 532 207 214 219 F12(M8)
OPzV12-180 12 180 522 240 219 224  F10(M8)
OPzV12-200 12 200 521 268 220 225 F14(M8)
OPzV2-200 2 200 103 206 355 390 F10(M8)
OPzV2-250 2 250 124 206 355 390 F10(M8)
OPzV2-300 2 300 145 206 355 390 F10(M8)
OPzV2-350 2 350 124 206 470 505 F10(M8)
OPzV2-420 2 420 145 206 470 505 F10(M8)
OPzV2-500 2 490 166 206 470 505 F10(M8)
OPzV2-770 2 770 210 254 470 505 F10(M8)
OPzV2-600 2 600 145 206 645 680 F10(M8)
OPzV2-800 2 800 191 210 645 680 F10(M8)
OPzV2-1000 2 1000 233 210 645 680 F10(M8)
OPzV2-1200 2 1200 276 210 645 680 F10(M8)
OPzV2-1500 2 1500 275 210 795 830 F10(M8)
OPzV2-2000 2 2000 399 214 770 805 F10(M8)
OPzV2-2500 2 2500 487 212 770 805 F10(M8)
OPzV2-3000 2 3000 576 212 770 805 F10(M8)
Description
HIGH INTELLIGENCE AND RELIABLE POWER SUPPLY IGBT Technology Full microprocessor control with no-break static and manual bypasses. Online double conversion technology (VFl) with isolation transformer on theinverter output. Extremely high short-circuit current to ensure compatibility with the most diffificult transformer applications (lighting, drives and industrial processes) and an isolation transformer on the inverter output. Compatibled with Watch & Save 3000 software as standard and can be remotely monitored using the Power NetGuard system from anywhere in the world. SIMPLE TO INSTALL Capability to install the UPS into any distribution system(neutral not required on rectifier input). Capability to separate the rectifier/bypass power networks and to power them from two separate sources, without Galvanic isolation(Necessary on UPS without an output transformer MAXIMUM BATTERY CARE Battery deep discharge protection; Temperature compensating charger; Built-in automatic and manual battery test feature. OTHER CHARACTERISTICS 0.8/0.9 power factor suitable for powering ICT and lndustrial loads. BACK FEED protection: to avoid energy feeding back into the mains supply cause a fault occur. MAXIMUM RELIABILITY AND AVAILABILITY Connect up to 6 units in parallel or N+1 redundancy, even of different power ratings. The UPS continue to work in parallel even if one of theinterconnecting communication cables is disconnected(CLOSED LOOP) LOW CONSUMPTION LEVELS LF31 Series UPS can achieve efficiencies >98% thanks to selectable Economy Mode which can be used in stable electrical environments to provide power supply continuity when the mains fail. ADVANCE COMMUNICATION: RS485/RS232/Dry Contact/SNMP(Optional)  
Specifications
Model 10KVA 15KVA 20KVA 30KVA 40KVA 60KVA    80KVA 100KVA
Capacity 8KW 12 KW 16 KW 24 KW 32 KW 48 KW    64 KW    80 KW
INPUT
Rated voltage 380/400/415 VAC  Three-phase
Voltage range ±20%
Frequency range 45-65Hz
Power factor >0.92 with harmonic filter
Current harmonic distortion <5% with harmonic filter
Soft Start 0 -100% in 10″
BYPASS INPUT
Rated voltage 230VAC   Single Phase
Permitted voltage range ±15%  (selectable from ±10% to ±25% from front panel)
Rated frequency 50/60Hz
Permitted frequency range ±2%    (selectable from ±1% to ±5% from front panel)
Standard features Back Feed portection; split bypass line
BATTERY
Type VRLA AGM / GEL;NICd
Battery Voltage 384VDC
Maximum recharge current(A) 0.2 X C10
AC ripple voltage <1%
INVERTER OUTPUT
Rated power(kVA) 10KVA 15KVA 20KVA 30KVA 40KVA 60KVA     80KVA 100KVA
Active power(kW)  8KW 12 KW 16 KW 24 KW 32 KW 48 KW     64 KW 80 KW
Number of phases 1
Rated voltage(V) 230VAC  Single Phase
Regulation of the output voltage 220 ~ 244VAC  phase/neutral (from control panel)
Crest factor(Ipeak/Irms) 3:1
Static stability ±1%
Dynamic stability ±5%
Frequency 50/60Hz configurable
Overload 110% 125% 150% of the rated current for 5h/10’/1′
Frequency stability ±0.05% on mains failure
System 10KVA 15KVA 20KVA 30KVA 40KVA 60KVA     80KVA 100KVA
Remote signaling Volt free contacts
Remote controls EPO and Bypass
Communication RS232 + Romote Contacts
Operation temperature 0℃ to  ~ 40℃
Relative humidity <95% non condensing
Colour Light grey ( RAL 7035)
Noise 54dBA at 1m 60dBA at 1m   65dBA at 1m
Protection degree IP20
Efficiency Smart Mode Up to 98%
Compliance Safety:EN 62040-1-1(Directive 2006/95/EC); EMC:6200-2(Directive 2004/108/EC)
Weight(KG)N.W 176 220 205 213 295 440 520 770
Dimensions:(WxDxH)mm 555*730*1210 800*730*1400 1115*730*1400
Internal batteries optional optional optional No      No No No No
Features:
  • Optional 7 ” touch LCD
  • Online double-conversionDSP technology guarantees high reliability
  • True galvanic isolation transformer designControl designed to withstand all kinds of loads
  • Intelligent battery management to prolong battery lifecycle
  • Redundant fan design and independent ventilation enhance durable operation under harsh environment
  • Adiustable battery numbers
  • Accept dual-mains input
  • Parallel operation with up to 4 units ( option )
  • Variety of communication options available
  • Reverse phase frequency operation and supportsnon-neutral input
 
Specifications
MODEL LF33 10K LF33 20K LF33 30K LF33 40K LF33  60K LF33  80K LF33 100K LF33 120K LF33 160K LF33 200K
CAPACITY 10KVA /8KW 20KVA /16KW 30KVA /24KW 40KVA /32KW 60KVA /48KW 80KVA /64KW 100KVA /80KW 120KVA /96KW 160KVA /128KW 200KVA /160KW
INPUT
Nominal Voltage 3 x 380VAC/400VAC (3Ph + N)
Acceptable Voltage Range 305VAC ~ 460VAC
Frequency 46-54Hzor56-64Hz
INVERTER
Nominal Voltage 3 x 380VAC/400VAC (3Ph + N)
Precision Stationary: ±1% Transitory: ±5% (load variations 100-0-100%)
Frequency 50/60 Hz synchronised ±1 % With mains absent ±0.1 Hz
Max. Synchronisation Speed ±1 Hz/s
Waveform Pure Sinewave
Total Harmonic Distortion (THDv) <2% (Linear Load) ; <5% (Non-linear Load)
Phase Displacement 120° ±1 % (balanced load); 120° ±2% (imbalances 50% of the load)
Dynamic Recovery Time Restore to 90% of rated value in 3 cycles
Overload capacity 110% for 10min; 150% for 60sec; >160% for 200ms
Admissible Crest Factor 3:1
Admissible Power Factor 0.6-1 (inductive or capacitive)
Imbalance Output Voltage @ 100% Unbalanced Load                    <1%
Current Limit High overload, short-circuit: RMS Voltage Limit; High Crest-Factor current: Peak Voltage Limit
STATIC BYPASS
Type Solid state
Voltage 3 x 380VAC/400VAC (3Ph + N)
Frequency 50/60 Hz
Activation Criterion Microprocessor control
Transfer Time Zero
Admissible Overload 150% for 1 hour; 180% for 30sec; >200% for 200ms
Transfer to Bypass Immediate, for overloads above 160%
Retransfer Automatic after alarm clear
MAINTENANCE BYPASS
Type Without interruption
Voltage 3 * 400V (3Ph + N)
Frequency 50/60 Hz
Overall Efficiency Line Mode 90% 91% 92% 93%
Battery Mode 90% 91% 93% 93%
BATTERY & CHARGER
Battery Type and Numbers 12VDC * 32 pcs (29-32 pcs adjustable)
Nominal Battery Voltage 384 VDC (Based on 32pcs batteries)
Charging Method CC/CV
Precision ±1%
Charging Current Max.: 40 A
Charging Voltage 432 VDC (Based on 32pcs batteries)
PHYSICAL
Dimensions, D x W x H(mm) 656 x 405 x 817 656 x 405 x 941 840x432x1140 975x554x1286 1200x910x1680 1500x1140x1800
Net Weight (Kgs) 180 205 295 330 451 519 950 1350
Features:
  • 60KW single power module in 3U
  • N+1or N+X parallel redundancy for power guarantee
  • Supports horizontal expansion by 1+1 cabinet paralleloperation.
  • Hot-swappable modular design decreases MTTR
  • High scalability
  • Built-in maintenance bypass switch for easy maintenance without interruptible
  • High efficiency double conversion online UPS
  • Flexible battery configuration and adjustable charging current
  • High overload capability
  • Power walk-in function
  • Built-in dynamic password protection
  • Built-in ultra communication slot
 
Technical Specifications
MODEL RM Pro 120K RM Pro 180K RM Pro 300K RM Pro 420K RM Pro 480K RM Pro 600K
Phase 3 Phase in / 3 Phase out
Cabinet Capacity* 120 KW 180 KW 300KW 420KW 480KW 600KW
Battery  Type Extemal Battery
One Power Module Capacity 60KVA/60KW
Max.   Power Module  No. 2 3 5 7 8 10
INPUT
Nominal Voltage 3×380/400/415   VAC(3Ph+N)
Voltage Range -30%~+20%
Nominal Frequency 50/60Hz(Auto Sensing)
Frequency Range 40Hz~70Hz
Power Factor >0.99  @100%  Load, >0.98 @ 50%  Load
Harmonic  Distortion   (THDi) <3%@  100%  load
OUTPUT
Nominal Voltage 3×380/400/415 VAC (3Ph+N)
Voltage  Regulation(Steady  State) ≤±1% Typical(balanced load); ≤±2% Typical(unbalanced load)
Nominal Frequency 50/60Hz
Frequency Range(Synchronized) 46Hz~54Hz or 56Hz~64Hz
Overload Capability 1 hour for ≤110%,10 mins for 111%~125%,1 min for 126%~150% and 200ms for >150%
Haronic Distortion ≤2% THD (Linear Load);  ≤4% THD (Non-linear Load)
Eficiency 96%
BATTERY / CHARGER
Nominal Voltage ’+/- 192V~+/- 240V(Selectable)
Maximum Voltage ’+/- 240V (12V×40 PCS)
Minimum Voltage ‘+/-192V (12V×32 PCS)
Floating Charge Voltage 2.28V/Cell (2.25~2.33 Selectable)
Boost Charging Voltage 2.35V/Cell
Temperature Compensation Yes
Maximum Charging Current (Per Power Module) 18A(Adjustable)
PHYSICAL
Cabinet Dimension (DxWxH)mm 1100x600x1475 1100x600x1475 1100x600x2010 1100×600×2010 1065x1000x2000 1065×1000×2000
Net Weight (Kg) 308 352 516 654 932 1020
Power Module (PM-60) Net Weight 44KGS
ENVIRONMENT
Operating Temperature 0~40℃
Relative Humidity 0~95% non-condensing
Altitude* <1000m for Nominal power
IP  Protection IP 20
MANAGEMENT
Smart  RS-232/USB Supports Windows⑧ Family, Linux and MAC
Optional SNMP Power management from SNMP manager and web browser
STANDARDS
Safety IEC/EN62040-1
EMC IEC/EN 62040-2 Category C3
Features:
Three Phase Hybrid Solar Inverter Off grid three phase solar hybrid inverter with pwm/mppt can be used in single-phase and three-phase ac load with total power not exceeding  100kva/120kva/125kva/150kva/160kva,384vdc to 380vac. •Pure sine wave output. •Low DC voltage, saving system cost. •Three phase solar inverter with built-in PWM or MPPT charge controller. •AC charge current 0-45A adjustable. •Wide LCD screen, clearly and precisely shows icon data. •100%imbalance loading design, 3 times peak power. •Setting different working modes based on variable usage requirements. •DC first/AC first optional. •Various communication ports and remote controls  
Specifications
MODEL DX100KVA DX120KVA DX125KVA DX150KVA DX160KVA 190KVA 200KVA
Rated Power 80KW 96KW 100KW 120KW 128KW 150KW 160KW
Peak Power(20ms) 240KVA 288KVA 300KVA 360KVA 384KVA 450KVA 480KVA
Start Motor 40HP 50HP 50HP 60HP 60HP 80HP 80HP
Battery Voltage 384VDC
Size(L*W*Hmm) 875*720*1380 1123*900*1605
Packing Size(L*W*Hmm) 980*825*1560 1185*960*1750
N.W.(kg) 512 592 612 612 642 705 755
G.W.(kg)(Wooden Packing) 552 632 652 652 692 755 805
INPUT DC Input Voltage Range 10.5VDC-15VDC(Single battery voltage)
AC Input Voltage Range 380Vac/400Vac±10%(customized 190Vac/200Vac)
AC Input Frequency Range 45Hz-55Hz(50Hz)/ 55Hz-65Hz(60Hz)
Max AC charging current 0-45A(Depending on the model)
AC charging method Three-stage (constant current, constant voltage, floating charge)
Phase 3 PHASE
OUTPUT Efficiency(Battery Mode) ≥85%
Output Voltage(Battery Mode) 380Vac/400Vac±10%(customized 190Vac/200Vac)
Output Frequency(Battery Mode) 50/60Hz ±1%
Output Wave(Battery Mode) Pure Sine Wave
Output waveform distortion Linear load≤3%
Efficiency(AC Mode) >99%
Output Voltage(AC Mode) Conforming to AC input
Output Frequency(AC Mode) Conforming to AC input
No load loss(Battery Mode) ≤1% rated power
No load loss(AC Mode) ≤2%rated power( charger does not work in AC mode)
No load loss (Energy saving Mode) ≤10W
Phase 3 PHASE
BATTERY VRLA Battery Charge Voltage :13.8V; Float Voltage:13.7V(Single battery voltage)
Customize battery Charging and discharging parameters of different types of batteries can be customized according to user requirements
(charging and discharging parameters of different types of batteries can be set through the operation panel)
Protection Battery undervoltage alarm 11V(Single battery voltage)
Battery undervoltage protection 10.5V(Single battery voltage)
Battery overvoltage alarm 15V(Single battery voltage)
Battery overvoltage protection 17V(Single battery voltage)
Battery overvoltage recovery voltage 14.5V(Single battery voltage)
Overload power protection Automatic protection (battery mode), circuit breaker or insurance (AC mode)
Inverter output short circuit protection Automatic protection (battery mode), circuit breaker or insurance (AC mode)
Temperature protection >90°C(Shut down output)
Alarm A Normal working condition, buzzer has no alarm sound
B Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection
C When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal
Inside Solar controller Charging Mode MPPT or PWM
(Optional) Charging current PWM: 100A-200A / MPPT: 50A/100A
PV Input Voltage Range PWM: 480V-704V / MPPT: 480V-640V
Max PV Input Voltage(Voc) PWM: 750V / MPPT: 800V
(At the lowest temperature)
PV Array Maximum Power PWM: 44.8KW(100A)/33.6KW*2(150A)/44.8KW*2(200A)) / (MPPT: 22.4KW(50A)/22.4KW*2(100A)
Standby loss ≤3W
Maximum conversion efficiency >95%
Working Mode Battery First/AC First/Saving Energy Mode
Transfer Time ≤4ms
Display LCD
Thermal method Forced Air Cooling
Communication(Optional) RS485/APP(WIFI monitoring or GPRS monitoring)
Environment Operating temperature -10℃~40℃
Storage temperature -15℃~60℃
Noise 2000m(More than derating)
Elevation ≤65dB
Humidity 0%~95% ,No condensation
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare