Features:
  • Spilt Phase output Voltage:
  • Output 1: HOT1 / HOT2 + N = 100 / 110 / 115 / 120VAC
  • Output 2: HOT1 + HOT2 = 200 / 220 / 230 / 240VAC
  • Pure sine wave output 1KW to 12KW
  • Built in high efficiency MPPT solar charge controller(99%),50-120A MPPT solar charger controller.
  • UPS function AC to DC automatic conversion time 5-8MS
  • Can use for different types of batteries:Lead-acid battery,GEL battery、lithium battery.
  • AC charging is adjustable from 5-30A/5-40A/5-50A/5-70A.
  • 3-Level voltage stabilizer to protectelectrical appliances from highand low voltage damage.
  • Strong load capacity with 3 times peak power,Support to bear withinductive loads. such as motors, pumps,air conditioners,compressor etc.
  • High-low voltage protection,overload, short-circuit Protection,under-voltage and over-temperature protection,over voltage,battery reverse connection(optional)etc.
  • Support RS232,RS485 for APP(WIFl) andremote monitoring (optional)

 

Technical Specifications
MODEL 1000W 1500W 2000W 3000W 4000W 5000W 6000W 8000W 10000W 12000W
INPUT Rated capacity 1000W 1500W 2000W 3000W 4000W 5000W 6000W 8000W 10000W 12000W
Peak power 3000W 4500W 6000W 9000W 12000W 15000W 18000W 24000W 30000W 36000W
Commercial Power range 110VAC:83V-137VAC 120VAC:90V-150V
220VAC:165V-275VAC 240VAC: 173V-287V
220VAC:176V-264VAC
240VAC:184V-276V
AC frequency range 45-65HZ
SOLAR MPPT Solar Controller 30A/50A/60A/80A 80A/100A
Solar input 360W/720W/1440W/1920W/2400W/2880W/3840W 3840W/4800W/7680W/9600W
PV input Voltage Range 14-130VDC(12V SYSTEM)/38-130VDC(24V SYSTEM)/72-180VDC(48VDC SYSTEM)/144-280VDC(96V SYSTEM)
BATTERY Type Lead-acid battery / GEL battery / Lithium battery
DC Voltage 12VDC /24VDC 24VDC/48VDC 48VDC/96VDC
Input voltage range 12VDC:10.5-15VDC    24VDC:21-30VDC    48VDC:42-60VDC  96VDC: 84-120VDC
Floating charge set 12.9 〜13.6 V(1PCS battery) can be set
Low voltage restored 12VDC:12.6-14.4VDC 24VDC:25.2-28.8VDC 48VDC:50.4-57.6VDC 96VDC:100.8-115.2VDC
Low voltage shutdown set 12VDC:10-10.9V       24VDC:20-21.8V    48VDC:40-43.6V   96VDC:80-87.2V
Over voltage protection 12VDC: 16.7VDC 24VDC:33.4V 48VDC:66.8V
Over voltage alarm 12VDC:15VDC 24VDC:30V    48VDC:60V
AC charging 5A-30A(40A, 50A, 60A.70A Optional)
OUTPUT Capable of starting
electric motor
0.5HP 1HP 1.5HP 2HP 3HP
Voltage range (VAC) 110VAC/220VAC ,120VAC/240VAC±10% (Auto-sensing) 110VAC/220VAC ,120VAC/240V AC±10% (Auto-sensing)
Transfer time Typical: 10ms(lncluding detection time)
Temperature protection ≥85°C alarm ≥90°C machine shut off
Overload IPS automatically shut down if overload exceeds 120% of normal value for 10 seconds,
IPS automatically resume work if overload comes to rated load.
Waveform Pure sine wave
Frequency Commercial power supply: shared frequency with the commercial inversion state:60/50±0.5
Output frequency range (electric supply mode) Tracking automatically
Temperature Operating Temperature 0°C~50°C
Thermal method Cooling fan in intelligent control<42°C fan rotates slowly to >45°C fan rotates fast
Appearance External Size(mm) (L*W*H) 510*325*215mm 645*325*215mm 765*320*250mm
Gross Size(mm) (L*W*H) 560*380*280mm 730*400*290mm 840*405*320mm
Net weight(kg) 14 15 18 20 31 34 35 52 54 56
Gross weight(kg) 16 17 20 22 35 37 38 56 58 60

Reviews

There are no reviews yet.

Be the first to review “Spilt Phase Single Phase Low Frequency Hybrid Solar Inverter VSP Series”

Your email address will not be published. Required fields are marked *

Quick Comparison

Spilt Phase Single Phase Low Frequency Hybrid Solar Inverter VSP Series remove3 Phase Low Frequency Solar Inverter DX Series removePortable Power Generator PS Series 600W remove3 Phase Low Frequency Online UPS LD33 Series removeBattery Cabinet battery Rack B1-B40 (Support Customized Size) removeLead Acid Maintenance Free Battery 5AH-250AH remove
NameSpilt Phase Single Phase Low Frequency Hybrid Solar Inverter VSP Series remove3 Phase Low Frequency Solar Inverter DX Series removePortable Power Generator PS Series 600W remove3 Phase Low Frequency Online UPS LD33 Series removeBattery Cabinet battery Rack B1-B40 (Support Customized Size) removeLead Acid Maintenance Free Battery 5AH-250AH remove
Image
SKUSF1033560130139-32SF1033560130139-5SF1033560130139-20SF1033560130139-3SF1033560130139-9SF1033560130139-15
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Features:
  • The battery cabinet is made of metal material, strong and can bear up to 500KG.
  • The battery cabinet is assembled in the form of assembly, which is conven-ient for transportation and simple for assembly.
  • The surface of electrostatic spraying, strong rust resistance, color can be fixed spray.
  • Other sizes can be customized.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
f
Content
Features:
  • Spilt Phase output Voltage:
  • Output 1: HOT1 / HOT2 + N = 100 / 110 / 115 / 120VAC
  • Output 2: HOT1 + HOT2 = 200 / 220 / 230 / 240VAC
  • Pure sine wave output 1KW to 12KW
  • Built in high efficiency MPPT solar charge controller(99%),50-120A MPPT solar charger controller.
  • UPS function AC to DC automatic conversion time 5-8MS
  • Can use for different types of batteries:Lead-acid battery,GEL battery、lithium battery.
  • AC charging is adjustable from 5-30A/5-40A/5-50A/5-70A.
  • 3-Level voltage stabilizer to protectelectrical appliances from highand low voltage damage.
  • Strong load capacity with 3 times peak power,Support to bear withinductive loads. such as motors, pumps,air conditioners,compressor etc.
  • High-low voltage protection,overload, short-circuit Protection,under-voltage and over-temperature protection,over voltage,battery reverse connection(optional)etc.
  • Support RS232,RS485 for APP(WIFl) andremote monitoring (optional)
 
Technical Specifications
MODEL 1000W 1500W 2000W 3000W 4000W 5000W 6000W 8000W 10000W 12000W
INPUT Rated capacity 1000W 1500W 2000W 3000W 4000W 5000W 6000W 8000W 10000W 12000W
Peak power 3000W 4500W 6000W 9000W 12000W 15000W 18000W 24000W 30000W 36000W
Commercial Power range 110VAC:83V-137VAC 120VAC:90V-150V 220VAC:165V-275VAC 240VAC: 173V-287V 220VAC:176V-264VAC 240VAC:184V-276V
AC frequency range 45-65HZ
SOLAR MPPT Solar Controller 30A/50A/60A/80A 80A/100A
Solar input 360W/720W/1440W/1920W/2400W/2880W/3840W 3840W/4800W/7680W/9600W
PV input Voltage Range 14-130VDC(12V SYSTEM)/38-130VDC(24V SYSTEM)/72-180VDC(48VDC SYSTEM)/144-280VDC(96V SYSTEM)
BATTERY Type Lead-acid battery / GEL battery / Lithium battery
DC Voltage 12VDC /24VDC 24VDC/48VDC 48VDC/96VDC
Input voltage range 12VDC:10.5-15VDC    24VDC:21-30VDC    48VDC:42-60VDC  96VDC: 84-120VDC
Floating charge set 12.9 〜13.6 V(1PCS battery) can be set
Low voltage restored 12VDC:12.6-14.4VDC 24VDC:25.2-28.8VDC 48VDC:50.4-57.6VDC 96VDC:100.8-115.2VDC
Low voltage shutdown set 12VDC:10-10.9V       24VDC:20-21.8V    48VDC:40-43.6V   96VDC:80-87.2V
Over voltage protection 12VDC: 16.7VDC 24VDC:33.4V 48VDC:66.8V
Over voltage alarm 12VDC:15VDC 24VDC:30V    48VDC:60V
AC charging 5A-30A(40A, 50A, 60A.70A Optional)
OUTPUT Capable of starting electric motor 0.5HP 1HP 1.5HP 2HP 3HP
Voltage range (VAC) 110VAC/220VAC ,120VAC/240VAC±10% (Auto-sensing) 110VAC/220VAC ,120VAC/240V AC±10% (Auto-sensing)
Transfer time Typical: 10ms(lncluding detection time)
Temperature protection ≥85°C alarm ≥90°C machine shut off
Overload IPS automatically shut down if overload exceeds 120% of normal value for 10 seconds, IPS automatically resume work if overload comes to rated load.
Waveform Pure sine wave
Frequency Commercial power supply: shared frequency with the commercial inversion state:60/50±0.5
Output frequency range (electric supply mode) Tracking automatically
Temperature Operating Temperature 0°C~50°C
Thermal method Cooling fan in intelligent control<42°C fan rotates slowly to >45°C fan rotates fast
Appearance External Size(mm) (L*W*H) 510*325*215mm 645*325*215mm 765*320*250mm
Gross Size(mm) (L*W*H) 560*380*280mm 730*400*290mm 840*405*320mm
Net weight(kg) 14 15 18 20 31 34 35 52 54 56
Gross weight(kg) 16 17 20 22 35 37 38 56 58 60
Features:
Three Phase Hybrid Solar Inverter Off grid three phase solar hybrid inverter with pwm/mppt can be used in single-phase and three-phase ac load with total power not exceeding  100kva/120kva/125kva/150kva/160kva,384vdc to 380vac. •Pure sine wave output. •Low DC voltage, saving system cost. •Three phase solar inverter with built-in PWM or MPPT charge controller. •AC charge current 0-45A adjustable. •Wide LCD screen, clearly and precisely shows icon data. •100%imbalance loading design, 3 times peak power. •Setting different working modes based on variable usage requirements. •DC first/AC first optional. •Various communication ports and remote controls  
Specifications
MODEL DX100KVA DX120KVA DX125KVA DX150KVA DX160KVA 190KVA 200KVA
Rated Power 80KW 96KW 100KW 120KW 128KW 150KW 160KW
Peak Power(20ms) 240KVA 288KVA 300KVA 360KVA 384KVA 450KVA 480KVA
Start Motor 40HP 50HP 50HP 60HP 60HP 80HP 80HP
Battery Voltage 384VDC
Size(L*W*Hmm) 875*720*1380 1123*900*1605
Packing Size(L*W*Hmm) 980*825*1560 1185*960*1750
N.W.(kg) 512 592 612 612 642 705 755
G.W.(kg)(Wooden Packing) 552 632 652 652 692 755 805
INPUT DC Input Voltage Range 10.5VDC-15VDC(Single battery voltage)
AC Input Voltage Range 380Vac/400Vac±10%(customized 190Vac/200Vac)
AC Input Frequency Range 45Hz-55Hz(50Hz)/ 55Hz-65Hz(60Hz)
Max AC charging current 0-45A(Depending on the model)
AC charging method Three-stage (constant current, constant voltage, floating charge)
Phase 3 PHASE
OUTPUT Efficiency(Battery Mode) ≥85%
Output Voltage(Battery Mode) 380Vac/400Vac±10%(customized 190Vac/200Vac)
Output Frequency(Battery Mode) 50/60Hz ±1%
Output Wave(Battery Mode) Pure Sine Wave
Output waveform distortion Linear load≤3%
Efficiency(AC Mode) >99%
Output Voltage(AC Mode) Conforming to AC input
Output Frequency(AC Mode) Conforming to AC input
No load loss(Battery Mode) ≤1% rated power
No load loss(AC Mode) ≤2%rated power( charger does not work in AC mode)
No load loss (Energy saving Mode) ≤10W
Phase 3 PHASE
BATTERY VRLA Battery Charge Voltage :13.8V; Float Voltage:13.7V(Single battery voltage)
Customize battery Charging and discharging parameters of different types of batteries can be customized according to user requirements
(charging and discharging parameters of different types of batteries can be set through the operation panel)
Protection Battery undervoltage alarm 11V(Single battery voltage)
Battery undervoltage protection 10.5V(Single battery voltage)
Battery overvoltage alarm 15V(Single battery voltage)
Battery overvoltage protection 17V(Single battery voltage)
Battery overvoltage recovery voltage 14.5V(Single battery voltage)
Overload power protection Automatic protection (battery mode), circuit breaker or insurance (AC mode)
Inverter output short circuit protection Automatic protection (battery mode), circuit breaker or insurance (AC mode)
Temperature protection >90°C(Shut down output)
Alarm A Normal working condition, buzzer has no alarm sound
B Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection
C When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal
Inside Solar controller Charging Mode MPPT or PWM
(Optional) Charging current PWM: 100A-200A / MPPT: 50A/100A
PV Input Voltage Range PWM: 480V-704V / MPPT: 480V-640V
Max PV Input Voltage(Voc) PWM: 750V / MPPT: 800V
(At the lowest temperature)
PV Array Maximum Power PWM: 44.8KW(100A)/33.6KW*2(150A)/44.8KW*2(200A)) / (MPPT: 22.4KW(50A)/22.4KW*2(100A)
Standby loss ≤3W
Maximum conversion efficiency >95%
Working Mode Battery First/AC First/Saving Energy Mode
Transfer Time ≤4ms
Display LCD
Thermal method Forced Air Cooling
Communication(Optional) RS485/APP(WIFI monitoring or GPRS monitoring)
Environment Operating temperature -10℃~40℃
Storage temperature -15℃~60℃
Noise 2000m(More than derating)
Elevation ≤65dB
Humidity 0%~95% ,No condensation
Features:
  • Capacity: 600W 512Wh /160000mAh
  • Input AC Output Power:Rated Power 600W Peak Power 1200W
  • Input AC Charging:AC100~120V/AC200~240V Built-in 200W
  • Input Car Charging:DC12V~24V/7A Max 120W Max
  • Input Solar Charging:DC12V~24V/120WMax
  • Output Voltage:230VAC±10%/110VAC±10%
  • Output Frequency: 50Hz±5%/60Hz±5%
  • USB Output:2*QC24W+PD27W+PD100W Max
  • DC Output:1*Cigarette Lighter+2*DC5521 Rated Output (13.8V/10A Max)
  • Output Waveform:Pure Sine Wave
  • LED:3 Levels(H/M/L)+SOS
  • UPS Function:Support(≤10mS)
 
Applications:
  • Mammogram
  • Ultrasound Equipments
  • Radiology rooms
Description
HIGH INTELLIGENCE AND RELIABLE POWER SUPPLY IGBT Technology Full microprocessor control with no-break static and manual bypasses. Online double conversion technology (VFl) with isolation transformer on theinverter output. Extremely high short-circuit current to ensure compatibility with the most diffificult transformer applications (lighting, drives and industrial processes) and an isolation transformer on the inverter output. Compatibled with Watch & Save 3000 software as standard and can be remotely monitored using the Power NetGuard system from anywhere in the world. SIMPLE TO INSTALL Capability to install the UPS into any distribution system(neutral not required on rectifier input). Capability to separate the rectifier/bypass power networks and to power them from two separate sources, without Galvanic isolation(Necessary on UPS without an output transformer MAXIMUM BATTERY CARE Battery deep discharge protection; Temperature compensating charger; Built-in automatic and manual battery test feature. OTHER CHARACTERISTICS 0.8/0.9 power factor suitable for powering ICT and lndustrial loads. BACK FEED protection: to avoid energy feeding back into the mains supply cause a fault occur. MAXIMUM RELIABILITY AND AVAILABILITY Connect up to 6 units in parallel or N+1 redundancy, even of different power ratings. The UPS continue to work in parallel even if one of theinterconnecting communication cables is disconnected(CLOSED LOOP) LOW CONSUMPTION LEVELS LF33 Series UPS can achieve efficiencies >98% thanks to selectable Economy Mode which can be used in stable electrical environments to provide power supply continuity when the mains fail. ADVANCE COMMUNICATION: RS485/RS232/Dry Contact/SNMP(Optional)  
Specifications
Model 10KVA 20KVA 30KVA 40KVA 60KVA 80KVA 100KVA 120KVA 160KVA 200KVA 250KVA 300KVA 400KVA 500KVA 600KVA
Capacity 8KW 16 KW 24 KW 32 KW  48 KW 64 KW  80 KW 96 KW 128 KW 160 KW 200KW 240KW 320KW 400KW  480KW
INPUT
Rated voltage 400 VAC  Three-Phase
Voltage range 380/400/415VAC(+25%,Can be set through the LCD panel)
Frequency range 40-70Hz(Automatically select synchronization range according to grid frequency)
Range(HZ) 50±5%(±10%) Bypass synchronization tracking
Rectifying pulse number 6 pulse rectification 6/12 pulse rectification 12 pulse rectifier
Phase system 3φ4W+PE(Three phase five wire system)
Battery voltage 384VDC 480VDC
Battery Quantity Standard with 32 Cells(30~34, can be set through the LCD panel)  Standard 40 Cells(38~42 knots,can be set by LCD panel)
OUTPUT
Power factor 0.8/0.9 (Optional)
Voltage(V) L-N: 220±1%   L-L: 380±1%
Three-phase 100% load unbalance voltage stability ≤2%,Allow 100% imbalance
Frequency(HZ) Normal power, tracking the frequency of power, Grid abnormal. 50±0.2%
Transfer time(ms) 0ms
Parallel operation mode (parallel type) Max 8 Parallel
Waveform distortion Linear loadTHD<3% ; Nonlinear loadTHD<5%
Overload capacity 125% full load for 10 minutes, maintain 150 % full load for 1 minute and then switch to bypass power supply, after reducing the loadcan automatically restore the inverter
Crest factor 3:1
Others
Index Standard with no transfer time maintenance bypass switch
Communication function RS232/RS485/Dry Contact/SNMP (Optional)
Panel display LED displays working status and fault indication; LCD displays three-phase input voltage, input frequency, three-phase output voltage, load,battery voltage, battery charge and discharge current, etc
Display  7″ Touchable LCD screen display
The audio noise(dB) <65(within 1 meter)
Alarm function Battery low voltage, abnormal power supply, overload, UPS failure, over temperature protection
Protection Input over voltage, battery under voltage, overload, short circuit, over temperature protection
Cooling way Forced cooling
Operating temperature 0℃ to  ~ 40℃
Humidity 0~95%, non-condensing
electromagnetic compatibility Conform GB7260.2
Size(W*D*H)(mm) 540*660*1135 1100*800*1800 800*800*1900 1200*850*1900 2600*1100*2000
Weight 196     233 276 329 461 547.5 643 754 1375
Features:
  • The battery cabinet is made of metal material, strong and can bear up to 500KG.
  • The battery cabinet is assembled in the form of assembly, which is conven-ient for transportation and simple for assembly.
  • The surface of electrostatic spraying, strong rust resistance, color can be fixed spray.
  • Other sizes can be customized.
 
Technical Specifications
Model Dimensions(W*D*H) (mm) Battery Capacity Battery Numbers Weight(kg)
B-1B 280x190x220 24AH/17AH 2/3PCS 2.2
B-1 435x210x270 17AH/24AH/38AH 5/3/2 PCS 3.3
65AH/100AH 1PC
B-1A 540x210x230 17AH/24AH/38AH 6/4/3PCS 4.5
B-2 450x470x320 17AH/24AH/38AH 10/6/4 PCS 7
65AH/100AH 2PCS
B-3 585x470x320 17AH/24AH/38AH 14/8/6PCS 9
65AH/100AH 3PCS
B-4 450x470x615 17AH/24AH/38AH 20/12/8PCS 15
65AH/100AH 4PCS
B-6 585x470x615 17AH/24AH/38AH 28/16/12PCS 18
65AH/100AH 6PCS
B-8 780x470x615 17AH/24AH/38AH 44/28/20PCS 21
65AH/100AH 8PCS
B-10 950x470x615 17AH/24AH/38AH 44/28/20PCS 24
65AH/100AH 10PCS
B-12 780x470x910 24AH/38AH 30/24PCS 32
65AH/100AH 12PCS
B-16 780x470x1190 24AH/38AH 40/32PCS 45
65AH/100AH 16PCS
B-20 950x470x1190 24AH/38AH 56/40PCS 50
65AH/100AH 20PCS
B-24 1150x470x1190 65AH/100AH 24PCS 57
B-32 780x880x1190 65AH/100AH 32PCS 95
B-40 950x880x1190 65AH/100AH 40PCS 100
Features:
Nomimal voltage: 12V Rated Capacity: 5Ah ~ 250Ah Operating temperature range: -15 ~ 45 ℃ The design life is 5 years Using new special process sheet formula to improve the utilization of active material Using high quality superfine glass fiberliquid-suction battery technology to exceed 99% gas recombination rate High-strength ABS plastic battery slot and cover with features of compact structure, corrosion resistant, impact resistance and anti-vibration and so on Small internal impedance, excellent performance when high current discharge Low self-discharge, wide operating temperature range Using multiple sealing technologies to ensure no leakage, no acid mist escaping to keep safe and reliable Using strict production process, unit voltage balance is strong Free maintenance, without adding water rehydration  
Technical Specifications
Model Nominal Voltage Capacity Dimension LXWXH (mm) Total Height (mm) Weight (KG) Terminal
VL12-24 12 24 166 175 125 125 8 M6
VL12-28 12 28 166 175 125 125 9 M6
VL12-33 12 33 196 130 163 180 10 M6
VL12-35 12 35 197 130 163 180 10.5 M6
VL12-40 12 40 197 166 171 171 13.5 M6
VL12-44 12 44 196 166 171 171 13.5 M6
VL12-55 12 55 230 138 211 229 17.2 M6
VL12-65 12 65 350 166 179 179 22 M6
VL12-70 12 70 260 169 211 229 23 M8
VL12-80 12 80 260 169 211 229 24 M8
VL12-90 12 90 307 169 211 234 28 M8
VL12-100 12 100 331 173 213 233 32 M8
VL12-120 12 120 407 174 209 233 3, 8 M8
VL12-130 12 134 341 173 283 287 41 M8
VL12-150 12 150 484 171 241 241 46 M8
VL12-160 12 160 534 209 216 237 52 M8
VL12-180 12 180 530 209 216 237 56 M8
VL12-200 12 200 522 240 220 244 64 M8
VL12-230 12 230 520 268 220 240 72.5 M8
VL12-250 12 250 520 268 220 249 76 M8
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A