Spilt Phase Single Phase Low Frequency Hybrid Solar Inverter VSP Series

$0.00

Shipped From Abroad

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130139-32
Brands:: Reeco Power

Description

Features:
  • Spilt Phase output Voltage:
  • Output 1: HOT1 / HOT2 + N = 100 / 110 / 115 / 120VAC
  • Output 2: HOT1 + HOT2 = 200 / 220 / 230 / 240VAC
  • Pure sine wave output 1KW to 12KW
  • Built in high efficiency MPPT solar charge controller(99%),50-120A MPPT solar charger controller.
  • UPS function AC to DC automatic conversion time 5-8MS
  • Can use for different types of batteries:Lead-acid battery,GEL battery、lithium battery.
  • AC charging is adjustable from 5-30A/5-40A/5-50A/5-70A.
  • 3-Level voltage stabilizer to protectelectrical appliances from highand low voltage damage.
  • Strong load capacity with 3 times peak power,Support to bear withinductive loads. such as motors, pumps,air conditioners,compressor etc.
  • High-low voltage protection,overload, short-circuit Protection,under-voltage and over-temperature protection,over voltage,battery reverse connection(optional)etc.
  • Support RS232,RS485 for APP(WIFl) andremote monitoring (optional)

 

Technical Specifications
MODEL 1000W 1500W 2000W 3000W 4000W 5000W 6000W 8000W 10000W 12000W
INPUT Rated capacity 1000W 1500W 2000W 3000W 4000W 5000W 6000W 8000W 10000W 12000W
Peak power 3000W 4500W 6000W 9000W 12000W 15000W 18000W 24000W 30000W 36000W
Commercial Power range 110VAC:83V-137VAC 120VAC:90V-150V
220VAC:165V-275VAC 240VAC: 173V-287V
220VAC:176V-264VAC
240VAC:184V-276V
AC frequency range 45-65HZ
SOLAR MPPT Solar Controller 30A/50A/60A/80A 80A/100A
Solar input 360W/720W/1440W/1920W/2400W/2880W/3840W 3840W/4800W/7680W/9600W
PV input Voltage Range 14-130VDC(12V SYSTEM)/38-130VDC(24V SYSTEM)/72-180VDC(48VDC SYSTEM)/144-280VDC(96V SYSTEM)
BATTERY Type Lead-acid battery / GEL battery / Lithium battery
DC Voltage 12VDC /24VDC 24VDC/48VDC 48VDC/96VDC
Input voltage range 12VDC:10.5-15VDC    24VDC:21-30VDC    48VDC:42-60VDC  96VDC: 84-120VDC
Floating charge set 12.9 〜13.6 V(1PCS battery) can be set
Low voltage restored 12VDC:12.6-14.4VDC 24VDC:25.2-28.8VDC 48VDC:50.4-57.6VDC 96VDC:100.8-115.2VDC
Low voltage shutdown set 12VDC:10-10.9V       24VDC:20-21.8V    48VDC:40-43.6V   96VDC:80-87.2V
Over voltage protection 12VDC: 16.7VDC 24VDC:33.4V 48VDC:66.8V
Over voltage alarm 12VDC:15VDC 24VDC:30V    48VDC:60V
AC charging 5A-30A(40A, 50A, 60A.70A Optional)
OUTPUT Capable of starting
electric motor
0.5HP 1HP 1.5HP 2HP 3HP
Voltage range (VAC) 110VAC/220VAC ,120VAC/240VAC±10% (Auto-sensing) 110VAC/220VAC ,120VAC/240V AC±10% (Auto-sensing)
Transfer time Typical: 10ms(lncluding detection time)
Temperature protection ≥85°C alarm ≥90°C machine shut off
Overload IPS automatically shut down if overload exceeds 120% of normal value for 10 seconds,
IPS automatically resume work if overload comes to rated load.
Waveform Pure sine wave
Frequency Commercial power supply: shared frequency with the commercial inversion state:60/50±0.5
Output frequency range (electric supply mode) Tracking automatically
Temperature Operating Temperature 0°C~50°C
Thermal method Cooling fan in intelligent control<42°C fan rotates slowly to >45°C fan rotates fast
Appearance External Size(mm) (L*W*H) 510*325*215mm 645*325*215mm 765*320*250mm
Gross Size(mm) (L*W*H) 560*380*280mm 730*400*290mm 840*405*320mm
Net weight(kg) 14 15 18 20 31 34 35 52 54 56
Gross weight(kg) 16 17 20 22 35 37 38 56 58 60

Reviews

There are no reviews yet.

Be the first to review “Spilt Phase Single Phase Low Frequency Hybrid Solar Inverter VSP Series”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsSpilt Phase Single Phase Low Frequency Hybrid Solar Inverter VSP Series removePortable Power Generator PS Series 1200W removePortable Power Station PS Series 2200W removeLead Acid Gel Battery 33AH-250AH removeHigh Frequency Modular UPS VM Series removeLine Interactive UPS DP Series 600VA-3000VA remove
NameSpilt Phase Single Phase Low Frequency Hybrid Solar Inverter VSP Series removePortable Power Generator PS Series 1200W removePortable Power Station PS Series 2200W removeLead Acid Gel Battery 33AH-250AH removeHigh Frequency Modular UPS VM Series removeLine Interactive UPS DP Series 600VA-3000VA remove
Image
SKUSF1033560130139-32SF1033560130139-19SF1033560130139-22SF1033560130139-14SF1033560130139-11SF1033560130139-17
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Features:
  • Valve sealed design, no free electrolyte, Maintenance -free
  • Designed floating service life:15 years @ 25 °C/68 °F.
  • Wide operating temperature range from -15°C to 35°C
  • Nanometer gel electrolytes eliminate the acid stratification and prolong cycle life
  • Low self-discharge rate: ≤3%/month.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Features:
  • Intelligent CPU control
  • Automatic power on when the the main power recovers
  • Cold start function
  • Power off charging function
  • USB/RS232/RJ-11/RJ-45 communication port (optional)
  • Offering LED and LCD panels for selection
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Features:
  • Spilt Phase output Voltage:
  • Output 1: HOT1 / HOT2 + N = 100 / 110 / 115 / 120VAC
  • Output 2: HOT1 + HOT2 = 200 / 220 / 230 / 240VAC
  • Pure sine wave output 1KW to 12KW
  • Built in high efficiency MPPT solar charge controller(99%),50-120A MPPT solar charger controller.
  • UPS function AC to DC automatic conversion time 5-8MS
  • Can use for different types of batteries:Lead-acid battery,GEL battery、lithium battery.
  • AC charging is adjustable from 5-30A/5-40A/5-50A/5-70A.
  • 3-Level voltage stabilizer to protectelectrical appliances from highand low voltage damage.
  • Strong load capacity with 3 times peak power,Support to bear withinductive loads. such as motors, pumps,air conditioners,compressor etc.
  • High-low voltage protection,overload, short-circuit Protection,under-voltage and over-temperature protection,over voltage,battery reverse connection(optional)etc.
  • Support RS232,RS485 for APP(WIFl) andremote monitoring (optional)
 
Technical Specifications
MODEL 1000W 1500W 2000W 3000W 4000W 5000W 6000W 8000W 10000W 12000W
INPUT Rated capacity 1000W 1500W 2000W 3000W 4000W 5000W 6000W 8000W 10000W 12000W
Peak power 3000W 4500W 6000W 9000W 12000W 15000W 18000W 24000W 30000W 36000W
Commercial Power range 110VAC:83V-137VAC 120VAC:90V-150V 220VAC:165V-275VAC 240VAC: 173V-287V 220VAC:176V-264VAC 240VAC:184V-276V
AC frequency range 45-65HZ
SOLAR MPPT Solar Controller 30A/50A/60A/80A 80A/100A
Solar input 360W/720W/1440W/1920W/2400W/2880W/3840W 3840W/4800W/7680W/9600W
PV input Voltage Range 14-130VDC(12V SYSTEM)/38-130VDC(24V SYSTEM)/72-180VDC(48VDC SYSTEM)/144-280VDC(96V SYSTEM)
BATTERY Type Lead-acid battery / GEL battery / Lithium battery
DC Voltage 12VDC /24VDC 24VDC/48VDC 48VDC/96VDC
Input voltage range 12VDC:10.5-15VDC    24VDC:21-30VDC    48VDC:42-60VDC  96VDC: 84-120VDC
Floating charge set 12.9 〜13.6 V(1PCS battery) can be set
Low voltage restored 12VDC:12.6-14.4VDC 24VDC:25.2-28.8VDC 48VDC:50.4-57.6VDC 96VDC:100.8-115.2VDC
Low voltage shutdown set 12VDC:10-10.9V       24VDC:20-21.8V    48VDC:40-43.6V   96VDC:80-87.2V
Over voltage protection 12VDC: 16.7VDC 24VDC:33.4V 48VDC:66.8V
Over voltage alarm 12VDC:15VDC 24VDC:30V    48VDC:60V
AC charging 5A-30A(40A, 50A, 60A.70A Optional)
OUTPUT Capable of starting electric motor 0.5HP 1HP 1.5HP 2HP 3HP
Voltage range (VAC) 110VAC/220VAC ,120VAC/240VAC±10% (Auto-sensing) 110VAC/220VAC ,120VAC/240V AC±10% (Auto-sensing)
Transfer time Typical: 10ms(lncluding detection time)
Temperature protection ≥85°C alarm ≥90°C machine shut off
Overload IPS automatically shut down if overload exceeds 120% of normal value for 10 seconds, IPS automatically resume work if overload comes to rated load.
Waveform Pure sine wave
Frequency Commercial power supply: shared frequency with the commercial inversion state:60/50±0.5
Output frequency range (electric supply mode) Tracking automatically
Temperature Operating Temperature 0°C~50°C
Thermal method Cooling fan in intelligent control<42°C fan rotates slowly to >45°C fan rotates fast
Appearance External Size(mm) (L*W*H) 510*325*215mm 645*325*215mm 765*320*250mm
Gross Size(mm) (L*W*H) 560*380*280mm 730*400*290mm 840*405*320mm
Net weight(kg) 14 15 18 20 31 34 35 52 54 56
Gross weight(kg) 16 17 20 22 35 37 38 56 58 60
Features:
  • Capacity: 1200W 1008Wh /315000mAh
  • Input AC Output Power:Rated Power 1200W Peak Power 2400W
  • Input AC Charging:AC100~125V/AC184~264V Bidirectional Inverter 700W Max
  • Input Car Charging:DC12V~24V/10A 240W Max
  • Input Solar Charging:DC12V~60V/10A 400W Max
  • Output Voltage:230VAC±10%/110VAC±10%
  • Output Frequency: 50Hz±5%/60Hz±5%
  • USB Output:2*5V2.4A +2*QC18W+2*PD60W Max
  • DC Output:1*Cigarette Lighter+2*DC5521 Rated Output (13.8V/10A Max)
  • Output Waveform:Pure Sine Wave
  • LED:3 Levels(H/M/L)+SOS
  • UPS Function:Support(≤10mS)
 
Applications:
  • Mammogram
  • Ultrasound Equipments
  • Radiology rooms
Features:
  • Capacity: 2200W 2048Wh /640000mAh
  • Input AC Output Power:Rated Power 2400W Peak Power 4800W
  • Input AC Charging:AC100~125V/AC174~264V Bidirectional Inverter 1400W Max
  • Input Car Charging:DC12V~24V/10A 240W Max
  • Input Solar Charging:DC16V~60V/10A 500W Max
  • Output Voltage:230VAC±10%/110VAC±10%
  • Output Frequency: 50Hz±5%/60Hz±5%
  • USB Output:2*QC18W+PD27W+PD100W Max
  • DC Output:1*Cigarette Lighter 12.8V/12A Max+2*DC5521 Rated Output 12.8V/5A Max
  • Output Waveform:Pure Sine Wave
  • LED:3 Levels(H/M/L)+SOS
  • UPS Function:Support ; Battery Expandable: Support
 
Applications:
  • Mammogram
  • Ultrasound Equipments
  • Radiology rooms
Features:
  • Valve sealed design, no free electrolyte, Maintenance -free
  • Designed floating service life:15 years @ 25 °C/68 °F.
  • Wide operating temperature range from -15°C to 35°C
  • Nanometer gel electrolytes eliminate the acid stratification and prolong cycle life
  • Low self-discharge rate: ≤3%/month.
 
Application
  • UPS Systems
  • Portable Equipment
  • Renewable Energy Systems
  • Electric Utilities
  • Outdoor control Equipment
  • Railroad Utilities
  • Telecom Systems
 
Technical Specifications
Model Nominal Voltage Capacity Dimension LXWXH (mm) Total Height (mm) Weight (KG/IBS) Terminal
VG12-33 12V 33AH 195 130 167 167 10 22.05 M6
VG12-35 12V 35AH 195 130 167 167 11.5 25.35 M6
VG12-38 12V 38AH 197 165 172 172 12.5 27.56 M6
VG12-40 12V 40AH 197 165 172 172 13.2 29.1 M6
VG12-45 12V 45AH 197 165 172 172 15 33.07 M6
VG12-50 12V 50AH 229 138 205 208 15.5 34.17 M6
VG12-55 12V 55AH 229 138 205 208 16.5 36.38 M6
VG12-65 12V 65AH 350 166 175 175 21 46.3 M8
VG12-70 12V 70AH 260 168 208 211 21.8 48.06 M8
VG12-80 12V 80AH 260 168 208 211 24 52.91 M8
VG12-90 12V 90AH 330 171 216 219 27 59.52 M8
VG12-100 12V 100AH 330 171 216 219 29.5 65.04 M8
VG12-120 12V 120AH 407 173 237 237 35 77.16 M8
VG12-150 12V 150AH 484 170 241 241 45 99.21 M8
VG12-200 12V 200AH 522 240 219 222 61.5 135.58 M8
VG12-250 12V 250AH 520 268 220 223 71 156.53 M8
Features:
Digital Control All parts of this series of UPS adopt digital control, each performance index of UPS is very excellent, and the control system is morestableand reliable.Each module has built-in automatic bypass switch and corresponding bypass current equalizing inductor, providing good bypass power supply equalization performance. Intelligent Battery Management Users can set the charging current, constant current, constant voltage and floatingcharging modescan be automatically and smoothly switched; Battery voltage can beset ±192Vdc/±240Vdc/±216Vdc/±228Vdc/±240Vdc (32/34/36/38/40 pcs optional) High Power Density Modular Design The capacity of each single module is30kVA, and the height is3U; UPS modulescan be added and removed onlineto achieve zero maintenance time. N+x Parallel Redundancy The quantity of redundant module can be set accordingly, When the redundant module reaches more than 2 hours, the system availability achieves 99.99%, MTBF(Mean Time Between Failures) lasts more than 250,000 hours; Supporting parallel connection between cabinets. A maximum of four cabinets can be parallel,and battery pack can be shared when UPS cabinet in parallel. Touchable LCD Display Screen Super large LCD display with touching function. Standard Cabinet Design The appearance ofthe standard cabinet is beautiful and generous, which can perfectly match the use environment ofthe computer room and save the space.

Safe and Easy to Maintain When an emergency occurs, users can switch to the maintenance bypass to supply power, and maintenance personnel can safely perform online maintenance; Press EPO button to shutdown in emergentsituation, and also have REPO function. Intelligent Management Centralized monitoring module (with hot-swap function), RS232/RS485 communication interface/SNMPcard (optional), can realize remote monitoringof UPS, relay card is optional.

 
Technical Specifications
Model VM 90K VM150K VM300K
Capacity UPS Cabinet 30-90KVA 30-150KVA 30-300KVA
Power Module 30kVA
INPUT Input Form 3P4W+G
Rated Voltage 380/400/415Vac
Voltage Range 207~478Vac
Frequency Range 40~70Hz
Input Power Factor ≥0.99
Bypass Range 380 upper limit: 25% (optional +10%s +15%、+20%) 400 upper limit: 20% (optional +10%、+15%) 415 upper limit: 15% (optional +10%) Lower limit: -45% (optional -20%s -30%) Bypass frequency protection range: ± 10%
Input Current Harmonic Wave ≤3% (100% non-linear)
OUTPUT Output Form 3P4W+G
Rated Voltage 380/400/415Vac
Output Power Factor 0.9 or 1
Voltage Accuracy ±1%
Output Frequency Mains Mode Synchronization with input; when mains frequency exceeds maximum value ±10% (can be set ±1%、 ±2%、±4%、±5%), output frequency 50X(±0.2%)Hz
Battery Mode (50/60±0.2%) Hz
Crest Factor 3:1
Conversion Time Mains mode — bypass mode: 0ms (tracking); Mains mode— battery mode: 0ms
Overload Capacity Load≤110%: 60 mins; Load≤125%: 10 mins; Load≤150%: 1 min; Load≥150%, shutdown immediately
Output Voltage Harmonic Wave ≤2% (100% linear)
Efficiency In normal mode 95%
Communication Port RS232、RS485、 Intelligent Slot*2 、 Dry connect port
BATTERY Battery Voltage ±192Vdc/±204Vdc/±216Vdc/±228Vdc/±240Vdc; (32/34/36/38/40pcs Optional)
Charging Current UPS Cabinet 30A Max 50A Max 100A Max
Power Module 10A Max
Environment Operating Temperature 0〜40°C
Relative Humidity 0-95% (non-condensing)
Storage Temperature -25-55°C (excluded battery)
Altitude < 1500m (derating if exceeding 1500m)
Physical Characteristic Outer Dimension (LxWxH) mm Cabinet 840X600X1400 1100X600X2000
Module 580 X 443 X 131
Weight (Net Weight) KG Cabinet 158 170 305
Module 33.5
Operative Standard YD/T 2165-2010
Features:
  • Intelligent CPU control
  • Automatic power on when the the main power recovers
  • Cold start function
  • Power off charging function
  • USB/RS232/RJ-11/RJ-45 communication port (optional)
  • Offering LED and LCD panels for selection
 
Application:
  • Personal Computer
  • Printer
  • POS(Point of sales)Terminals
  • Security System
  • Fax Machine
  • Modem, WiFi Router
 
Technical Specifications:
 
Model DP600 DP1000 DP1200 DP2000 DP3000
Capacity 600VA/360W 1000VA/600W 1200VA/720W 2000VA/1200W 3000VA/1800W
INPUT
Voltage 110/120VAA or 220/230/240VAC
Voltage Range 67-137VAC/135-275VAC
Frequency Range 50Hz Or 60Hz(Auto-Sensing)
OUTPUT
Output Voltage 110/120VAA or 220/230/240VAC
AC Voltage Regulation ± 10%
Frequency Range (Batt. Mode) 50 HZ or 60 Hz ± 10%
Transfer Time Typical 6-10 ms
Waveform (Battery Mode) Simulated Sine Wave
BATTERY
Battery Voltage 12V/7AH*1 12V/9AH*1 12V/7AH*2 12V/9AH*2 12V/7AH*4
Charge Time 8 hours up to 80-90%
PROTECTION
Full Protection Auto Detection, discharge protection,output Short circuit, Over load, Battery low voltage protection
 Communication Port USB/RS232/RJ11/RJ45  (Optional)
Display LED/LCD
          Alarm
Battery Mode Every 4 Seconds one beep
Low Battery Capacity Every 1 Seconds one beep
Overload Every 1 Seconds one beep
Fault Keep beeping
ENVIRONMENT
Humidity 0-90% Rh @ 0-40℃ (Non-Condensing)
Noise Level 40dB
Dimension(mm) 320*90*140 330* 100*150 365*140*165 365*140*165 395*145*210
N.W.(kg) 5.2 6 10 12.6 21
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare