1 hour for ≤110%,10 mins for 111%~125%,1 min for 126%~150% and 200ms for >150%
Haronic Distortion
≤2% THD (Linear Load); ≤4% THD (Non-linear Load)
Eficiency
96%
BATTERY / CHARGER
Nominal Voltage
’+/- 192V~+/- 240V(Selectable)
Maximum Voltage
’+/- 240V (12V×40 PCS)
Minimum Voltage
‘+/-192V (12V×32 PCS)
Floating Charge Voltage
2.28V/Cell (2.25~2.33 Selectable)
Boost Charging Voltage
2.35V/Cell
Temperature Compensation
Yes
Maximum Charging Current
(Per Power Module)
18A(Adjustable)
PHYSICAL
Cabinet Dimension (DxWxH)mm
1100x600x1475
1100x600x1475
1100x600x2010
1100×600×2010
1065x1000x2000
1065×1000×2000
Net Weight (Kg)
308
352
516
654
932
1020
Power Module (PM-60) Net Weight
44KGS
ENVIRONMENT
Operating Temperature
0~40℃
Relative Humidity
0~95% non-condensing
Altitude*
<1000m for Nominal power
IP Protection
IP 20
MANAGEMENT
Smart RS-232/USB
Supports Windows⑧ Family, Linux and MAC
Optional SNMP
Power management from SNMP manager and web browser
STANDARDS
Safety
IEC/EN62040-1
EMC
IEC/EN 62040-2 Category C3
Features:
DSP digital control technology enables UPS more stable performance-+
Environment friendly eco-designed
Active input power factor correction
Wide range of input voltage and frequency
Zero power switch delay
Adaptive Load Management.
Sufficient Expansion Slots: USB ,RS485 ,AS400 SNMP cards(Optional)
Support the generator
Specifications:
Model
33VT 10K
33VT 10KL
33VT 20K
33VT 20KL
33VT 30KL
33VT 40KL
Capacity
10KVA/9000W
20KVA/18KW
30KVA/27KW
40KVA/36KW
Input
Nominal Voltage
380/400/415Vac
Voltage Range
207-475VAC(3P4W+G)
Current
14A
28A
42A
67A
Frequency
40-70Hz (Adjustable)
Power Factor
≥0.99
Output
Voltage
380VAC 1±1% (3P4W+G)
Frequency
46-54Hz Synchronous mains power; 50Hz( Frequency Range 40-46Hz -54-60Hz);50Hz(Battery mode)
Current
15A
30A
45A
61A
Power Factor
0.9
Crest Factor
3:1
THD
Line load <3%
Chrage Current
5.5A
1A
7.5A
1A
5.5A
Battery Nominal Voltage
192VDC
±192VDC
Transfer Time
0ms
Overload Capacity
105%±5%< Load<125%±5% :1 min transfer to bypass
125% ±5% < Load<135 % ±5 % :30s transfer to bypass
Load > 135 % ± 5 %: 300s transfer to bypass
Communication
SNMP,RS-232,USB+lntelligent Slot
Operating Environment
Temperature
0°C~40°C
Humidity
20%~95%
Dimension
Width (mm)
260
260
260
260
Depth (mm)
560
533
710
560
Height (mm)
717
501
717
717
Net Weight(Kg)
26
72
57.5
98
58.5
62
Features:
Three Phase Hybrid Solar Inverter
Off grid three phase solar hybrid inverter with pwm/mppt can be used in single-phase and three-phase ac load with total power not exceeding 100kva/120kva/125kva/150kva/160kva,384vdc to 380vac.
•Pure sine wave output.
•Low DC voltage, saving system cost.
•Three phase solar inverter with built-in PWM or MPPT charge controller.
•AC charge current 0-45A adjustable.
•Wide LCD screen, clearly and precisely shows icon data.
•100%imbalance loading design, 3 times peak power.
•Setting different working modes based on variable usage requirements.
•DC first/AC first optional.
•Various communication ports and remote controls
HIGH INTELLIGENCE AND RELIABLE POWER SUPPLYIGBT Technology
Full microprocessor control with no-break static and manual bypasses.
Online double conversion technology (VFl) with isolation transformer on theinverter output.
Extremely high short-circuit current to ensure compatibility with the most diffificult transformer applications (lighting, drives and industrial processes) and an isolation transformer on the inverter output.
Compatibled with Watch & Save 3000 software as standard and can be remotely monitored using the Power NetGuard system from anywhere in the world.
SIMPLE TO INSTALL
Capability to install the UPS into any distribution system(neutral not required on rectifier input).
Capability to separate the rectifier/bypass power networks and to power them from two separate sources, without Galvanic isolation(Necessary on UPS without an output transformer
MAXIMUM BATTERY CARE
Battery deep discharge protection;
Temperature compensating charger;
Built-in automatic and manual battery test feature.
OTHER CHARACTERISTICS
0.8/0.9 power factor suitable for powering ICT and lndustrial loads.
BACK FEED protection: to avoid energy feeding back into the mains supply cause a fault occur.
MAXIMUM RELIABILITY AND AVAILABILITY
Connect up to 6 units in parallel or N+1 redundancy, even of different power ratings.
The UPS continue to work in parallel even if one of theinterconnecting communication cables is disconnected(CLOSED LOOP)
LOW CONSUMPTION LEVELS
LF31 Series UPS can achieve efficiencies >98% thanks to selectable Economy Mode which can be used in stable electrical environments to provide power supply continuity when the mains fail.
ADVANCE COMMUNICATION:
RS485/RS232/Dry Contact/SNMP(Optional)
Specifications
Model
10KVA
15KVA
20KVA
30KVA
40KVA
60KVA
80KVA
100KVA
Capacity
8KW
12 KW
16 KW
24 KW
32 KW
48 KW
64 KW
80 KW
INPUT
Rated voltage
380/400/415 VAC Three-phase
Voltage range
±20%
Frequency range
45-65Hz
Power factor
>0.92 with harmonic filter
Current harmonic distortion
<5% with harmonic filter
Soft Start
0 -100% in 10″
BYPASS INPUT
Rated voltage
230VAC Single Phase
Permitted voltage range
±15% (selectable from ±10% to ±25% from front panel)
Reviews