Spilt Phase Single Phase Low Frequency Hybrid Solar Inverter VSP Series

$0.00

Shipped From Abroad

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130139-32
Brands:: Reeco Power

Description

Features:
  • Spilt Phase output Voltage:
  • Output 1: HOT1 / HOT2 + N = 100 / 110 / 115 / 120VAC
  • Output 2: HOT1 + HOT2 = 200 / 220 / 230 / 240VAC
  • Pure sine wave output 1KW to 12KW
  • Built in high efficiency MPPT solar charge controller(99%),50-120A MPPT solar charger controller.
  • UPS function AC to DC automatic conversion time 5-8MS
  • Can use for different types of batteries:Lead-acid battery,GEL battery、lithium battery.
  • AC charging is adjustable from 5-30A/5-40A/5-50A/5-70A.
  • 3-Level voltage stabilizer to protectelectrical appliances from highand low voltage damage.
  • Strong load capacity with 3 times peak power,Support to bear withinductive loads. such as motors, pumps,air conditioners,compressor etc.
  • High-low voltage protection,overload, short-circuit Protection,under-voltage and over-temperature protection,over voltage,battery reverse connection(optional)etc.
  • Support RS232,RS485 for APP(WIFl) andremote monitoring (optional)

 

Technical Specifications
MODEL 1000W 1500W 2000W 3000W 4000W 5000W 6000W 8000W 10000W 12000W
INPUT Rated capacity 1000W 1500W 2000W 3000W 4000W 5000W 6000W 8000W 10000W 12000W
Peak power 3000W 4500W 6000W 9000W 12000W 15000W 18000W 24000W 30000W 36000W
Commercial Power range 110VAC:83V-137VAC 120VAC:90V-150V
220VAC:165V-275VAC 240VAC: 173V-287V
220VAC:176V-264VAC
240VAC:184V-276V
AC frequency range 45-65HZ
SOLAR MPPT Solar Controller 30A/50A/60A/80A 80A/100A
Solar input 360W/720W/1440W/1920W/2400W/2880W/3840W 3840W/4800W/7680W/9600W
PV input Voltage Range 14-130VDC(12V SYSTEM)/38-130VDC(24V SYSTEM)/72-180VDC(48VDC SYSTEM)/144-280VDC(96V SYSTEM)
BATTERY Type Lead-acid battery / GEL battery / Lithium battery
DC Voltage 12VDC /24VDC 24VDC/48VDC 48VDC/96VDC
Input voltage range 12VDC:10.5-15VDC    24VDC:21-30VDC    48VDC:42-60VDC  96VDC: 84-120VDC
Floating charge set 12.9 〜13.6 V(1PCS battery) can be set
Low voltage restored 12VDC:12.6-14.4VDC 24VDC:25.2-28.8VDC 48VDC:50.4-57.6VDC 96VDC:100.8-115.2VDC
Low voltage shutdown set 12VDC:10-10.9V       24VDC:20-21.8V    48VDC:40-43.6V   96VDC:80-87.2V
Over voltage protection 12VDC: 16.7VDC 24VDC:33.4V 48VDC:66.8V
Over voltage alarm 12VDC:15VDC 24VDC:30V    48VDC:60V
AC charging 5A-30A(40A, 50A, 60A.70A Optional)
OUTPUT Capable of starting
electric motor
0.5HP 1HP 1.5HP 2HP 3HP
Voltage range (VAC) 110VAC/220VAC ,120VAC/240VAC±10% (Auto-sensing) 110VAC/220VAC ,120VAC/240V AC±10% (Auto-sensing)
Transfer time Typical: 10ms(lncluding detection time)
Temperature protection ≥85°C alarm ≥90°C machine shut off
Overload IPS automatically shut down if overload exceeds 120% of normal value for 10 seconds,
IPS automatically resume work if overload comes to rated load.
Waveform Pure sine wave
Frequency Commercial power supply: shared frequency with the commercial inversion state:60/50±0.5
Output frequency range (electric supply mode) Tracking automatically
Temperature Operating Temperature 0°C~50°C
Thermal method Cooling fan in intelligent control<42°C fan rotates slowly to >45°C fan rotates fast
Appearance External Size(mm) (L*W*H) 510*325*215mm 645*325*215mm 765*320*250mm
Gross Size(mm) (L*W*H) 560*380*280mm 730*400*290mm 840*405*320mm
Net weight(kg) 14 15 18 20 31 34 35 52 54 56
Gross weight(kg) 16 17 20 22 35 37 38 56 58 60

Reviews

There are no reviews yet.

Be the first to review “Spilt Phase Single Phase Low Frequency Hybrid Solar Inverter VSP Series”

Your email address will not be published. Required fields are marked *

Quick Comparison

Spilt Phase Single Phase Low Frequency Hybrid Solar Inverter VSP Series removeHigh Frequency Modular UPS RM Pro Series removeDC UPS with POE Port 45W/60/100/120W with Lithium Battery removeHigh Frequency Modular UPS VM Series removeHigh Frequency Rack Mount UPS RTX Series removeLine Interactive UPS AP Series 1000VA-3000VA remove
NameSpilt Phase Single Phase Low Frequency Hybrid Solar Inverter VSP Series removeHigh Frequency Modular UPS RM Pro Series removeDC UPS with POE Port 45W/60/100/120W with Lithium Battery removeHigh Frequency Modular UPS VM Series removeHigh Frequency Rack Mount UPS RTX Series removeLine Interactive UPS AP Series 1000VA-3000VA remove
Image
SKUSF1033560130139-32SF1033560130139-10SF1033560130139-7SF1033560130139-11SF1033560130139-13SF1033560130139-16
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Features:
  • 60KW single power module in 3U
  • N+1or N+X parallel redundancy for power guarantee
  • Supports horizontal expansion by 1+1 cabinet paralleloperation.
  • Hot-swappable modular design decreases MTTR
  • High scalability
  • Built-in maintenance bypass switch for easy maintenance without interruptible
  • High efficiency double conversion online UPS
  • Flexible battery configuration and adjustable charging current
  • High overload capability
  • Power walk-in function
  • Built-in dynamic password protection
  • Built-in ultra communication slot
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Features:
  • Compact Size with nice housing case design. Stable performance with strong compatibility.
  • Built-in adapter, wide input, voltage range (100-240VAC).
  • Built-in multiple DC voltage (5/9/12/24/48VDC)output interfaces which can be used with external power adapters or solar panel.
  • Built-in large capacity lithium-ion batteries which is expanded up to 165Wh for long backup time.
  • 100W has 19VDC output, it can be used for desktop computer / laptop computer.
  • 60W/100W with WIFI function, it can be connected to the upper computer control. ( wall mounted type and tower type design).
  • Customize various of plugs and DC interfaces.
  • LCD indicator display design for monitor the working status easier.
  • Built-in multiple protection circuits, intelligently realize overcharge, over discharge, over current, overload, over temperature and short circuit protection
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Features:
1)19 inches standard design of rack mount, compact structure. 2)Sin wave output provides best power supply guarantee. 3)Zero transfer time between mains mode and battery mode. 4)Detection function of input neutral wire and live wire. 5)Having voltage surge protection function and strong anti-interference function. 6)Equipped with correction function of input power factor 7) Supporting mobile smart monitoring card , users can real-time monitor every data of the UPS by mobile APP.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Features:
  • Pure sine wave output
  • DSP digital control
  • Boost and buck AVR for voltage stabilization
  • Cold start function
  • Intelligent battery management
  • Short circuit and overload protection
  • Off-mode charging
  • Offering LED and LCD panels for selection
  • Optional USB/RS232/RJ45/SNMP communication port
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Features:
  • Spilt Phase output Voltage:
  • Output 1: HOT1 / HOT2 + N = 100 / 110 / 115 / 120VAC
  • Output 2: HOT1 + HOT2 = 200 / 220 / 230 / 240VAC
  • Pure sine wave output 1KW to 12KW
  • Built in high efficiency MPPT solar charge controller(99%),50-120A MPPT solar charger controller.
  • UPS function AC to DC automatic conversion time 5-8MS
  • Can use for different types of batteries:Lead-acid battery,GEL battery、lithium battery.
  • AC charging is adjustable from 5-30A/5-40A/5-50A/5-70A.
  • 3-Level voltage stabilizer to protectelectrical appliances from highand low voltage damage.
  • Strong load capacity with 3 times peak power,Support to bear withinductive loads. such as motors, pumps,air conditioners,compressor etc.
  • High-low voltage protection,overload, short-circuit Protection,under-voltage and over-temperature protection,over voltage,battery reverse connection(optional)etc.
  • Support RS232,RS485 for APP(WIFl) andremote monitoring (optional)
 
Technical Specifications
MODEL 1000W 1500W 2000W 3000W 4000W 5000W 6000W 8000W 10000W 12000W
INPUT Rated capacity 1000W 1500W 2000W 3000W 4000W 5000W 6000W 8000W 10000W 12000W
Peak power 3000W 4500W 6000W 9000W 12000W 15000W 18000W 24000W 30000W 36000W
Commercial Power range 110VAC:83V-137VAC 120VAC:90V-150V 220VAC:165V-275VAC 240VAC: 173V-287V 220VAC:176V-264VAC 240VAC:184V-276V
AC frequency range 45-65HZ
SOLAR MPPT Solar Controller 30A/50A/60A/80A 80A/100A
Solar input 360W/720W/1440W/1920W/2400W/2880W/3840W 3840W/4800W/7680W/9600W
PV input Voltage Range 14-130VDC(12V SYSTEM)/38-130VDC(24V SYSTEM)/72-180VDC(48VDC SYSTEM)/144-280VDC(96V SYSTEM)
BATTERY Type Lead-acid battery / GEL battery / Lithium battery
DC Voltage 12VDC /24VDC 24VDC/48VDC 48VDC/96VDC
Input voltage range 12VDC:10.5-15VDC    24VDC:21-30VDC    48VDC:42-60VDC  96VDC: 84-120VDC
Floating charge set 12.9 〜13.6 V(1PCS battery) can be set
Low voltage restored 12VDC:12.6-14.4VDC 24VDC:25.2-28.8VDC 48VDC:50.4-57.6VDC 96VDC:100.8-115.2VDC
Low voltage shutdown set 12VDC:10-10.9V       24VDC:20-21.8V    48VDC:40-43.6V   96VDC:80-87.2V
Over voltage protection 12VDC: 16.7VDC 24VDC:33.4V 48VDC:66.8V
Over voltage alarm 12VDC:15VDC 24VDC:30V    48VDC:60V
AC charging 5A-30A(40A, 50A, 60A.70A Optional)
OUTPUT Capable of starting electric motor 0.5HP 1HP 1.5HP 2HP 3HP
Voltage range (VAC) 110VAC/220VAC ,120VAC/240VAC±10% (Auto-sensing) 110VAC/220VAC ,120VAC/240V AC±10% (Auto-sensing)
Transfer time Typical: 10ms(lncluding detection time)
Temperature protection ≥85°C alarm ≥90°C machine shut off
Overload IPS automatically shut down if overload exceeds 120% of normal value for 10 seconds, IPS automatically resume work if overload comes to rated load.
Waveform Pure sine wave
Frequency Commercial power supply: shared frequency with the commercial inversion state:60/50±0.5
Output frequency range (electric supply mode) Tracking automatically
Temperature Operating Temperature 0°C~50°C
Thermal method Cooling fan in intelligent control<42°C fan rotates slowly to >45°C fan rotates fast
Appearance External Size(mm) (L*W*H) 510*325*215mm 645*325*215mm 765*320*250mm
Gross Size(mm) (L*W*H) 560*380*280mm 730*400*290mm 840*405*320mm
Net weight(kg) 14 15 18 20 31 34 35 52 54 56
Gross weight(kg) 16 17 20 22 35 37 38 56 58 60
Features:
  • 60KW single power module in 3U
  • N+1or N+X parallel redundancy for power guarantee
  • Supports horizontal expansion by 1+1 cabinet paralleloperation.
  • Hot-swappable modular design decreases MTTR
  • High scalability
  • Built-in maintenance bypass switch for easy maintenance without interruptible
  • High efficiency double conversion online UPS
  • Flexible battery configuration and adjustable charging current
  • High overload capability
  • Power walk-in function
  • Built-in dynamic password protection
  • Built-in ultra communication slot
 
Technical Specifications
MODEL RM Pro 120K RM Pro 180K RM Pro 300K RM Pro 420K RM Pro 480K RM Pro 600K
Phase 3 Phase in / 3 Phase out
Cabinet Capacity* 120 KW 180 KW 300KW 420KW 480KW 600KW
Battery  Type Extemal Battery
One Power Module Capacity 60KVA/60KW
Max.   Power Module  No. 2 3 5 7 8 10
INPUT
Nominal Voltage 3×380/400/415   VAC(3Ph+N)
Voltage Range -30%~+20%
Nominal Frequency 50/60Hz(Auto Sensing)
Frequency Range 40Hz~70Hz
Power Factor >0.99  @100%  Load, >0.98 @ 50%  Load
Harmonic  Distortion   (THDi) <3%@  100%  load
OUTPUT
Nominal Voltage 3×380/400/415 VAC (3Ph+N)
Voltage  Regulation(Steady  State) ≤±1% Typical(balanced load); ≤±2% Typical(unbalanced load)
Nominal Frequency 50/60Hz
Frequency Range(Synchronized) 46Hz~54Hz or 56Hz~64Hz
Overload Capability 1 hour for ≤110%,10 mins for 111%~125%,1 min for 126%~150% and 200ms for >150%
Haronic Distortion ≤2% THD (Linear Load);  ≤4% THD (Non-linear Load)
Eficiency 96%
BATTERY / CHARGER
Nominal Voltage ’+/- 192V~+/- 240V(Selectable)
Maximum Voltage ’+/- 240V (12V×40 PCS)
Minimum Voltage ‘+/-192V (12V×32 PCS)
Floating Charge Voltage 2.28V/Cell (2.25~2.33 Selectable)
Boost Charging Voltage 2.35V/Cell
Temperature Compensation Yes
Maximum Charging Current (Per Power Module) 18A(Adjustable)
PHYSICAL
Cabinet Dimension (DxWxH)mm 1100x600x1475 1100x600x1475 1100x600x2010 1100×600×2010 1065x1000x2000 1065×1000×2000
Net Weight (Kg) 308 352 516 654 932 1020
Power Module (PM-60) Net Weight 44KGS
ENVIRONMENT
Operating Temperature 0~40℃
Relative Humidity 0~95% non-condensing
Altitude* <1000m for Nominal power
IP  Protection IP 20
MANAGEMENT
Smart  RS-232/USB Supports Windows⑧ Family, Linux and MAC
Optional SNMP Power management from SNMP manager and web browser
STANDARDS
Safety IEC/EN62040-1
EMC IEC/EN 62040-2 Category C3
Features:
  • Compact Size with nice housing case design. Stable performance with strong compatibility.
  • Built-in adapter, wide input, voltage range (100-240VAC).
  • Built-in multiple DC voltage (5/9/12/24/48VDC)output interfaces which can be used with external power adapters or solar panel.
  • Built-in large capacity lithium-ion batteries which is expanded up to 165Wh for long backup time.
  • 100W has 19VDC output, it can be used for desktop computer / laptop computer.
  • 60W/100W with WIFI function, it can be connected to the upper computer control. ( wall mounted type and tower type design).
  • Customize various of plugs and DC interfaces.
  • LCD indicator display design for monitor the working status easier.
  • Built-in multiple protection circuits, intelligently realize overcharge, over discharge, over current, overload, over temperature and short circuit protection
 
Specifications
Model DCP-45W DCP-60W DCP-100W DCP-120W
Input voltage 100-240Vac/50-60Hz
12-24Vdc (2.5A Max)
1*9/12V(2A) (selectable)
Output voltage 4*12V(3.5A) Standard: 4*12V(5A) Customized: 3*12V(5A)+1*19V(3A) Standard: 4*12V(8A) Customized: 3*12V(8A)+1*19V(5A) Standard: 4*12V(10A) Customized: 3*12V(10A)+1*19V(6A)
1*5VDC+2*USB (2.4A)
Standard: 1*24(1.2A) /48V(0.6A)(POE 1 Gbps) (Selectable) Customized: 1)2*24(1.2A) /48V(0.6A)(POE 1 Gbps) (Selectable) 2)1*24(1.2A) /48V(0.6A)(POE 1 Gbps) (Selectable)+1*15V(1.5A)/24V(1A) POE(Selectable) 3)2*15V(1.5A)/24V(1A) POE(Selectable)
Efficiency AC mode:>85%,Battery mode:>90%
battery size 18650/21700/32700 18650/21700/32700 18650/21700/32700 18650/21700/32700
battery type Lithium-ion battery/LiFePO4 battery
battery capacity 8000-20800mah 8000-48000mah 8000-48000mah 8000-48000mah
battery numbers 4/8 4/8 4/8 4/8
Material ABS
protection function Over-charge, Over-discharge, Over-current, overload, over-temperature,short circuit
operating Temperature 0℃~40℃
Storage Temperature -10℃-50℃
humidity 10%-90%RH
altitude <3000m
Noise level <45db
Product Dimensions 180*130*64mm 214*158.5*86mm 214*158.5*86mm 214*158.5*86mm
package size 196*202*73mm 230*230*95mm 230*230*95mm 230*230*95mm
Net weight 1.27(max) 1.85kg(max)   1.88kg(max)   1.9kg(max)
Gross weight 1.32(max) 2.6kg(max)   2.63kg(max)   2.65kg(max)
Features:
Digital Control All parts of this series of UPS adopt digital control, each performance index of UPS is very excellent, and the control system is morestableand reliable.Each module has built-in automatic bypass switch and corresponding bypass current equalizing inductor, providing good bypass power supply equalization performance. Intelligent Battery Management Users can set the charging current, constant current, constant voltage and floatingcharging modescan be automatically and smoothly switched; Battery voltage can beset ±192Vdc/±240Vdc/±216Vdc/±228Vdc/±240Vdc (32/34/36/38/40 pcs optional) High Power Density Modular Design The capacity of each single module is30kVA, and the height is3U; UPS modulescan be added and removed onlineto achieve zero maintenance time. N+x Parallel Redundancy The quantity of redundant module can be set accordingly, When the redundant module reaches more than 2 hours, the system availability achieves 99.99%, MTBF(Mean Time Between Failures) lasts more than 250,000 hours; Supporting parallel connection between cabinets. A maximum of four cabinets can be parallel,and battery pack can be shared when UPS cabinet in parallel. Touchable LCD Display Screen Super large LCD display with touching function. Standard Cabinet Design The appearance ofthe standard cabinet is beautiful and generous, which can perfectly match the use environment ofthe computer room and save the space.

Safe and Easy to Maintain When an emergency occurs, users can switch to the maintenance bypass to supply power, and maintenance personnel can safely perform online maintenance; Press EPO button to shutdown in emergentsituation, and also have REPO function. Intelligent Management Centralized monitoring module (with hot-swap function), RS232/RS485 communication interface/SNMPcard (optional), can realize remote monitoringof UPS, relay card is optional.

 
Technical Specifications
Model VM 90K VM150K VM300K
Capacity UPS Cabinet 30-90KVA 30-150KVA 30-300KVA
Power Module 30kVA
INPUT Input Form 3P4W+G
Rated Voltage 380/400/415Vac
Voltage Range 207~478Vac
Frequency Range 40~70Hz
Input Power Factor ≥0.99
Bypass Range 380 upper limit: 25% (optional +10%s +15%、+20%) 400 upper limit: 20% (optional +10%、+15%) 415 upper limit: 15% (optional +10%) Lower limit: -45% (optional -20%s -30%) Bypass frequency protection range: ± 10%
Input Current Harmonic Wave ≤3% (100% non-linear)
OUTPUT Output Form 3P4W+G
Rated Voltage 380/400/415Vac
Output Power Factor 0.9 or 1
Voltage Accuracy ±1%
Output Frequency Mains Mode Synchronization with input; when mains frequency exceeds maximum value ±10% (can be set ±1%、 ±2%、±4%、±5%), output frequency 50X(±0.2%)Hz
Battery Mode (50/60±0.2%) Hz
Crest Factor 3:1
Conversion Time Mains mode — bypass mode: 0ms (tracking); Mains mode— battery mode: 0ms
Overload Capacity Load≤110%: 60 mins; Load≤125%: 10 mins; Load≤150%: 1 min; Load≥150%, shutdown immediately
Output Voltage Harmonic Wave ≤2% (100% linear)
Efficiency In normal mode 95%
Communication Port RS232、RS485、 Intelligent Slot*2 、 Dry connect port
BATTERY Battery Voltage ±192Vdc/±204Vdc/±216Vdc/±228Vdc/±240Vdc; (32/34/36/38/40pcs Optional)
Charging Current UPS Cabinet 30A Max 50A Max 100A Max
Power Module 10A Max
Environment Operating Temperature 0〜40°C
Relative Humidity 0-95% (non-condensing)
Storage Temperature -25-55°C (excluded battery)
Altitude < 1500m (derating if exceeding 1500m)
Physical Characteristic Outer Dimension (LxWxH) mm Cabinet 840X600X1400 1100X600X2000
Module 580 X 443 X 131
Weight (Net Weight) KG Cabinet 158 170 305
Module 33.5
Operative Standard YD/T 2165-2010
Features:
1)19 inches standard design of rack mount, compact structure. 2)Sin wave output provides best power supply guarantee. 3)Zero transfer time between mains mode and battery mode. 4)Detection function of input neutral wire and live wire. 5)Having voltage surge protection function and strong anti-interference function. 6)Equipped with correction function of input power factor 7) Supporting mobile smart monitoring card , users can real-time monitor every data of the UPS by mobile APP.  
Technical Specifications
Model RTX3110KL RTX3115KL RTX3120KL
Rated Power 10kVA/9kW 15kVA/13.5kW 20kVA/18kW
INPUT Voltage Range 207-475Vac3P4W+G
Working Frequency Range 40-70HZ (settable)
Input Power Factor >0.95
OUTPUT Rated Voltage and Accuracy 220Vac(l±l%)lP2W+G
Output Frequency 46-54Hz synchronize with mains power; 50Hz (Mains power between 40-46Hz and 54-60Hz); 50Hz(Battery)
Rated Current 45A 68A 91A
Output Power Factor 0.9
Output Harmonic Wave W3%
Crest Factor  3:1
Output Overload 105%±5%<Load≤125%±5%: Convert to bypass output and alarm after 1 min; 125%±5%<Load ≤50%±5%: Convert to bypass output and alarm after 30s; Load>150%±5%: Convert to bypass output and alarm after 300ms.
Transfer Time 0ms
Efficiency >92%
BATTERY Rated Voltage 192Vdc
Quantity 16
Charging Current 5.5A
Dimension (LxWxH) mm 665*482.6*132.5 655*482.6*265
Weight 23kg 34kg 35kg
Working Temperature 0°〜40°C
Working Humidity 20% 〜95%
Noise ≤60dB
Features:
  • Pure sine wave output
  • DSP digital control
  • Boost and buck AVR for voltage stabilization
  • Cold start function
  • Intelligent battery management
  • Short circuit and overload protection
  • Off-mode charging
  • Offering LED and LCD panels for selection
  • Optional USB/RS232/RJ45/SNMP communication port
 
Technical Specifications
 
MODEL UPS-AP1K ( L ) UPS-AP2K ( L ) UPS-AP3K ( L )
Capacity 1000VA/700W 2000VA/1400W 3000VA/2100W
INPUT
Voltage range 145~275VAC±5V
Frequency range 50Hz-60Hz
OUTPUT
Output voltage 220VAC
AC voltage range ±10%
Frequency range(batt.mode) 50Hz ± 0.25Hz or 60Hz ± 0.3Hz
Overload 105%-110%: UPS beep alarm, do not shut down.
110%-130%: auto shut down after 30 seconds
> 130%: auto shut down immediately
Transfer time <typical 4ms
Waveform(batt.mode) Pure sine wave
BATTERY
Standard model Battery type 12V7Ah
Numbers 2 4 6
Charging current(Max.) Assume: 1A± 10%; Max: 1A or 2A for option
Charging voltage 27.3VDC±1% 54.7VDC±1% 82.0VDC±1%
Long-run model Battery type 12V, AH depending on applicant
Numbers 3 6 8
Charging current(Max.) > 5A
Charging voltage 27.4VDC±1% 82.1VDC±1% 109.4VDC±1%
PHYSICAL
Standard model Dimension, LxWxH(mm) 360x147x220 440x192x340 440x192x340
Net weight(kgs) 11.9 22 27.9
Long-run model Dimension, LxWxH(mm) 360x147x220 440x192x340 440x192x340
Net weight(kgs) 8.5 16 18.2
ENVIRONMENT
Humidity 20-90%RH @0-40°C (non-condensing)
Noise level Less than 55dBA@1 Meter
MANAGEMENT
Smart RS-232 Support windows 2000/2003/XP/Vista/2008, Windows7/8, Linux, Unix, and MAC
Optional SNMP Power management from SNMP Management and web browser
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare