Sugentech Inclix Troponin I Test Kit

Ask for Price$0.00

Shipped From Abroad

  • INCLIX™ Troponin I quantitatively measures troponin I concentration in whole blood, serum or plasma. using the INCLIX™ analyzer. For in vitro diagnostic use only.

Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.

SF1033560084-230
Brands:: Sugentech
Brands

Description

  • INCLIX™ Troponin I quantitatively measures troponin I concentration in whole blood, serum or plasma. using the INCLIX™ analyzer. For in vitro diagnostic use only.
  • Cardiac troponin I (Tn I) is a protein found in myocardial muscle and the most sensitive biomarker for detection of acute myocardial infarction (AMI).The concentration of Tn I in the healthy human is below about 0.5 ng/ml and the level of Tn I is increased within 4-6 hours after the onset of chest pain. After cardiac injury occurs, peak in approximately 8 to 28 hours, and remain elevated for 3 to 10 days following AMI. The Tn I test is well known to be an important prognostic indicator of heart disease.
  • The Tn I Test is based on immunochromatography technology. When the sample is loaded to the device, the detection antibody which is conjugated with the colloidal gold in the dried pad binds to Tn I and flows through the membrane. The detection antibody-gold conjugate and Tn I move to the test line area and are accumulated by the capture antibody immobilized on the membrane. This leads to the generation of a reddish colored band. The intensity of the band depends on quantity of Tn I molecules and is analyzed by INCLIX™ analyzer for quantitative readout

Reviews

There are no reviews yet.

Be the first to review “Sugentech Inclix Troponin I Test Kit”

Your email address will not be published. Required fields are marked *

Quick Comparison

Sugentech Inclix Troponin I Test Kit removeErma B-111 Bilirubin Meter removeZenithlab (IB-9025A) Laboratory Incubator removeAvalun 48 INR Microcuvette removeDiscover 14 Panel Cup with Adulterants Per Pack removeHawksley 1400 Haematocrit Centrifuge remove
NameSugentech Inclix Troponin I Test Kit removeErma B-111 Bilirubin Meter removeZenithlab (IB-9025A) Laboratory Incubator removeAvalun 48 INR Microcuvette removeDiscover 14 Panel Cup with Adulterants Per Pack removeHawksley 1400 Haematocrit Centrifuge remove
ImageSugentech Inclix Troponin I Test KitAvalun 48 INR MicrocuvetteDrug Test Cup
SKUSF1033560084-230SF1033560084-6SF1033560084-109SF1033560084-74SF1033560084-28SF1033560084-118
Rating
Price

Ask for Price$0.00

Ask for Price$0.00

$350.00

Ask for Price$0.00

Ask for Price$0.00

$690.00

Stock

Out of stock

AvailabilityOut of stock
Add to cart

DescriptionShipped From Abroad
  • INCLIX™ Troponin I quantitatively measures troponin I concentration in whole blood, serum or plasma. using the INCLIX™ analyzer. For in vitro diagnostic use only.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Aboard  The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Microprocessor control.
  • Digital display setting and actual temperature.
  • Over temperature alarm, PID self-tuning.
  • Digital display running timer.
  • Stainless steel interior.
  • Electricity leakage protection.
  • With glass inner door, With hidden door locks.
  • Mechanical overheat protection, cut off the heating sources.
  • Automatic alarm after operation.
  • Suitable for constant temperature tests.
  • Suitable for bacteria cultivation, breeding, ferment.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Out stock LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self contained and the entire cup is tamper resistant. Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
The Hawksley Haematospin 1400 Centrifuges are built in the UK and are made from durable and high-quality components. These centrifuges are ideal for veterinary laboratories and practices specifically designed to produce reliable and accurate results on blood and urine. One of the main features of this centrifuge is that it takes both 2ml microtubes and 75mm microhaematocrits. The classic design of these centrifuges is used worldwide with guaranteed support for all servicing and parts. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
  • INCLIX™ Troponin I quantitatively measures troponin I concentration in whole blood, serum or plasma. using the INCLIX™ analyzer. For in vitro diagnostic use only.
  • Cardiac troponin I (Tn I) is a protein found in myocardial muscle and the most sensitive biomarker for detection of acute myocardial infarction (AMI).The concentration of Tn I in the healthy human is below about 0.5 ng/ml and the level of Tn I is increased within 4-6 hours after the onset of chest pain. After cardiac injury occurs, peak in approximately 8 to 28 hours, and remain elevated for 3 to 10 days following AMI. The Tn I test is well known to be an important prognostic indicator of heart disease.
  • The Tn I Test is based on immunochromatography technology. When the sample is loaded to the device, the detection antibody which is conjugated with the colloidal gold in the dried pad binds to Tn I and flows through the membrane. The detection antibody-gold conjugate and Tn I move to the test line area and are accumulated by the capture antibody immobilized on the membrane. This leads to the generation of a reddish colored band. The intensity of the band depends on quantity of Tn I molecules and is analyzed by INCLIX™ analyzer for quantitative readout
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin. Feature
  • Auto zero function: Manual blanking not required
  • Dual wavelength measurement system:
  • 2 wave lengths 455nm and 575nm
  • Plays major role to remove the interference caused due to Hemolysis & turbidity of sample
  • LED Light source:
  • LED does not require replacement as it lasts longer
  • As compared to Lamp, LED are more suitable as there is no intensity fluctuations
  • No warm up time required.
  • Flexible unit selection:
  • Two units either mg/dl or umol/L are selectable, ease of reporting
  • Compact slot for Capillary:
  • Accuracy of results are directly related to proper alignment of Capillary
  • B-111 has the easiest mode to ensure precise values
  • Data transfer:
  • External device can be connected to instrument through RS232 por
  • USB port
Technical Specification
  • Light source - LED
  • Wavelength - 455nm and 575nm
  • Net weight - 1kg
  • Measuring range - 0-30 mg/dl , 510 umol/L
  • Display - 16×2 LCD module with backlight
  • Auto calibration - Yes
  • Sample type - Serum or plasma
  • Sample volume - 40-80μL
  • Test time - <5sec
  • Units - mg/dl or umol/L
  • Dimensions - 150 (W) × 115 (H) × 190 (D) mm
  • Interface - RS232
  • Reading cuvette - Heparinized micro capillary holder
  • Storage temperature - 15-40°c
  • Power supply - DC 9V(DC adapter)
  • Power consumption - <2W
Features:
  • Microprocessor control.
  • Digital display setting and actual temperature.
  • Over temperature alarm, PID self-tuning.
  • Digital display running timer.
  • Stainless steel interior.
  • Electricity leakage protection.
  • With glass inner door, With hidden door locks.
  • Mechanical overheat protection, cut off the heating sources.
  • Automatic alarm after operation.
  • Suitable for constant temperature tests.
  • Suitable for bacteria cultivation, breeding, ferment.
  Technical Specification: Model: IB-9025A Working size: 250x250x250mm/9.84x9.84x9.84inch Power: 150W Temperature range: Room temperature+5~65℃ Temperature resolution: 0.1℃ Temperature fluctuation: ±0.5℃ Timer: 0-9999min Voltage: 110V 60Hz / 220V 50Hz Dimension: 380x370x580mm/14.96x14.57x22.83inch Size: 52cm*46cm*75cm / 20.5in*18.2in*29.6in Gross Weight:42kg / 93lb Net Weight: 23kg / 51lb Warranty: 1 year
LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users.
Features:
  • Fully automated "plug-and-play"   behavior
  • Reduced blood volume (only 3µL)
  • A large space for blood drop-off
  • Fills up quickly, using just capillarity
  • Easy handling, thanks to its 3D shape
  • Optimized preservation in individual pouches, in boxes of 12, 24, or 48 units
All-in-One Design
FDA 510(K) & CLIA Waived Up to 99% accuracy rate Results in as little as 1 minute 24 Month Shelf Life from Date of Manufacture Secure, seal and send to lab for confirmation Built in temperature strip Available to test up to 17 substances with adulterants or 18 without adulterants Adulterants available
 
 
The Hawksley Haematospin 1400 Centrifuges are built in the UK and are made from durable and high-quality components. These centrifuges are ideal for veterinary laboratories and practices specifically designed to produce reliable and accurate results on blood and urine. One of the main features of this centrifuge is that it takes both 2ml microtubes and 75mm microhaematocrits. The classic design of these centrifuges is used worldwide with guaranteed support for all servicing and parts. Technical specifications:
  • Speed: 11,800rpm with 24- place rotor
  • RCF: 14,000g with 24-place rotor
  • Acceleration: 0-11,800rpm in 60 seconds, with 24-place rotor
  • Brake: Automatic
  • Noise: 62dB running with 24-place rotor
  • Motor: High precision AC/DC series wound motor, brush gear, computer wound coil winding, balance armature and high speed bearings.
  • Timer: 0-15 minute timer, graduated in 1 minute increments. Automatic switch at zero
  • Weight: 5.1Kg net (without rotor)
  • Dimensions: 23.5cm height x 27cm diameter, footprint 16cm diameter
  • Construction: Aluminium casing with a steel lid
  • Finish: Body cream white baked enamel, with matt black baked enamel lid
 
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar