Sugentech Inclix Troponin I Test Kit

$0.00

Shipped From Abroad

  • INCLIX™ Troponin I quantitatively measures troponin I concentration in whole blood, serum or plasma. using the INCLIX™ analyzer. For in vitro diagnostic use only.

Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.

SF1033560084-230
Brands:: Sugentech
Brands

Description

  • INCLIX™ Troponin I quantitatively measures troponin I concentration in whole blood, serum or plasma. using the INCLIX™ analyzer. For in vitro diagnostic use only.
  • Cardiac troponin I (Tn I) is a protein found in myocardial muscle and the most sensitive biomarker for detection of acute myocardial infarction (AMI).The concentration of Tn I in the healthy human is below about 0.5 ng/ml and the level of Tn I is increased within 4-6 hours after the onset of chest pain. After cardiac injury occurs, peak in approximately 8 to 28 hours, and remain elevated for 3 to 10 days following AMI. The Tn I test is well known to be an important prognostic indicator of heart disease.
  • The Tn I Test is based on immunochromatography technology. When the sample is loaded to the device, the detection antibody which is conjugated with the colloidal gold in the dried pad binds to Tn I and flows through the membrane. The detection antibody-gold conjugate and Tn I move to the test line area and are accumulated by the capture antibody immobilized on the membrane. This leads to the generation of a reddish colored band. The intensity of the band depends on quantity of Tn I molecules and is analyzed by INCLIX™ analyzer for quantitative readout

Reviews

There are no reviews yet.

Be the first to review “Sugentech Inclix Troponin I Test Kit”

Your email address will not be published. Required fields are marked *

Quick Comparison

Sugentech Inclix Troponin I Test Kit removeAGD Erma EL-120 ELectrolyte Analyzer removeAlcohol Pad Per Pack removeApexBio HemoSmart Gold Hemoglobin Meter removeAutomatic Pipette removeSkyla Hi POC Clinical Chemistry Analyzer remove
NameSugentech Inclix Troponin I Test Kit removeAGD Erma EL-120 ELectrolyte Analyzer removeAlcohol Pad Per Pack removeApexBio HemoSmart Gold Hemoglobin Meter removeAutomatic Pipette removeSkyla Hi POC Clinical Chemistry Analyzer remove
ImageSugentech Inclix Troponin I Test Kit
SKUSF1033560084-230SF1033560084-125SF1033560084-64SF1033560084-29SF1033560084-130SF1033560060-2
Rating
Price

$0.00

$1,320.00

$4.25

$55.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
  • INCLIX™ Troponin I quantitatively measures troponin I concentration in whole blood, serum or plasma. using the INCLIX™ analyzer. For in vitro diagnostic use only.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In Stock HemoSmart GOLD offers a fast and easy way to measure hemoglobin level and is the first biosensor-based palm sized hemoglobin testing system in the world.The one of its kind strip-based testing method offers ease of use and portability and requires only 1μL of blood.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
This Automatic Pipette will help you get your lab up and running in no time—at a great price! Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The skyla Hi POC Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results.The use of skyla Hi in the management of diabetes enables better access to testing and rapid clinical decision making, discussion,and implementation of optimized treatment. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
  • INCLIX™ Troponin I quantitatively measures troponin I concentration in whole blood, serum or plasma. using the INCLIX™ analyzer. For in vitro diagnostic use only.
  • Cardiac troponin I (Tn I) is a protein found in myocardial muscle and the most sensitive biomarker for detection of acute myocardial infarction (AMI).The concentration of Tn I in the healthy human is below about 0.5 ng/ml and the level of Tn I is increased within 4-6 hours after the onset of chest pain. After cardiac injury occurs, peak in approximately 8 to 28 hours, and remain elevated for 3 to 10 days following AMI. The Tn I test is well known to be an important prognostic indicator of heart disease.
  • The Tn I Test is based on immunochromatography technology. When the sample is loaded to the device, the detection antibody which is conjugated with the colloidal gold in the dried pad binds to Tn I and flows through the membrane. The detection antibody-gold conjugate and Tn I move to the test line area and are accumulated by the capture antibody immobilized on the membrane. This leads to the generation of a reddish colored band. The intensity of the band depends on quantity of Tn I molecules and is analyzed by INCLIX™ analyzer for quantitative readout
Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface. Features:
  • Parameters: Na+,K+,Cl-, iCa++ / Li
  • It works on ISE principle
  • Sample Type: Whole blood, Serum, Plasma, Urine
  • Low reagent consumption
  • Sample requirement is only 90ul
  • 60 samples per hour
  • Automatic two point calibration after 4hrs and one point calibration with each sample analysis
  • Air bubble detection
  • Track reagents consumption and provides alerts
  • For low reagent volume
  • Precision testing facility to get CV and SD
  • Trilevel Quality Control with LJ plots of last 30days
  • Low aspiration volume
  • Fast sample processing
  • Accurate and Precise results
Technical Specifications:
Parameters Na+, K+, Cl– /Ca++
Principle Ion Selective Electrode (ISE)
Sample Type Analyses whole blood, serum, plasma and urine
Sample Volume ≤100 µL
Analysis Time ≤60 seconds
Throughout ≤60 samples per hour
Data Link Serial (RS232)
External Interface USB (Keyboard, Mouse)
Operating Condition 10° C to 35° C, Relative Humidity up to 85%
Storage Condition Temp: 10° C to 40° C
Relative Humidity up to 85% non- condensing
Power Supply 100 to 240 VAC ±10%, 50Hz
Dimensions 395 x 260 x 375 mm
Weight 7.5 kg
 
Click Here To Download Catalogue
Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use. Size and packing of Medical Alcohol pad:
  • Pad Size: Unfolded: 30 x 60 mm (other size can be request ).
  • Folded: 30x30 mm, 30 x 35mm,can be 2ply or 4ply ( other size, ply can be request ).
  • Aluminum Package: 60 x 50 mm , 50 x 50mm approximate ( other size can be request ).
  • Packing: 100/200 pcs per inner box, 50/ 100 boxes per carton(packing can be request).
Use of Medical Alcohol pad:
  • For cleaning prior to injection or to disinfect the hurted skin for family and medical treatment organization use.
  • For preparation and immediate disinfection of skin, wound area orr Instrument and utensil.
Notice of Medical Alcohol pad:
  • Not for eyes;
  • keep out of reach of children;
  • For external use only;
  • please stop using if you feel allergic or amyctic
Materials - Non-Woven Fabric
Trademark - OEM/ODM
Specification - CE&ISO13485
   
HemoSmart GOLD offers a fast and easy way to measure hemoglobin level and is the first biosensor-based palm sized hemoglobin testing system in the world.The one of its kind strip-based testing method offers ease of use and portability and requires only 1μL of blood. Feature
  • LCD Backlight
  • Small Blood Sample
  • Splash Proof
  • Strip Ejection
  • Hgb/Hct
  • Fast Result
Specification
  • Measurement Range: 0-24.0 g/dL
  • Power Supply: 3A battery X 2
  • Testing Time (seconds): 5 seconds
  • Sample Volume (μL): 1 μL
  • Memory Capabilities: 100 sets with date and time
  • Operating Temperature (°C): 10 °C~40 °C
 
Click Here To Download Catalogue
This Automatic Pipette will help you get your lab up and running in no time—at a great price! Features:
  • Lowest operation and tip ejection forces
  • Fully autoclavable
  • Ultra light weight with space-age materials
  • Secondary adjustment option for various liquid classes
  • Spring loaded tip con
  • For transferring molecular samples and PCR mix solutions.
  • One set is for DNA work and the other for RNA work. Each with the following specs
  • Light weight, traditional tip shaft, and will fit all generic brands of tips
  • Equal to or better than accuracy and precision compared to ISO 8655, so results can be trusted.
  • Easy and quick volume adjustment with or without gloves. Foolproof volume lock prevents accidental volume changes.
  • Low maintenance and autoclavable 121° for at least 20 minutes
  • Quick release
skyla Hi Analyzer enables better access to testing and rapid clinical decision making, discussion, and implementation of optimized treatment. To get the result, only prepare <1 μl fingertips blood or venous blood (depends on test item) without pretreatment with easy steps and then read the result after 6 mins. The device allows two specimens be tested in one run and provides fully automatic procedures from checking the validity of cartridge to printing the results. Reagent Kit
  • HbA1C
  • CRP
  • Lipid Panel (TC,TG, HDL, LDL#)
  • Lipid Plus Panel (Glu,TC,TG, HDL, LDL#)
Main Specification
Principle
Turbidimetric Method / Biochemistry
Device
Testing Time
5~20 minutes (depends on test items)
Display and Interface
5″ TFT color touch screen LCD
Memory Capacity
50,000 test results
Dimension of Analyzer
270 x 188 x 148 mm
Weight of Analyzer
1.7 kg
Dimension of Printer Module
134 x 100 x 82.7 mm
Weight of Printer Module
0.37 kg
Power Supply
100~240 volts AC, 50-60Hz
Data Transmission
USB 2.0*4 / USB 3.0*1 / RS232*1 / RJ45*1 / Wi-Fi (optional)
Reagent and Samples
Samples
Fingertips blood or venous blood
Samples Volume
0.8 ~ 30 μL (depends on test item)
Storage Temperature (Reagent)
2 ~ 8˚C
Humidity
Relative humidity < 95% (Non-condensing)
Temperature
10 ~ 32 ˚C
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description