SURTRON FLASH 160 HF

$0.00

Shipped From Abroad

The SURTRON FLASH 160 HF is a high-frequency electrosurgical unit engineered for precision monopolar and bipolar procedures, including microsurgery, without causing tissue alterations. It offers programmable RF power emissions, enabling operations with durations as short as 10 milliseconds. The device supports various surgical modes such as pure CUT, cut-coagulation BLEND, incision with reduced eschar production (ENHANCED), superficial coagulation (FORCED COAG), deep coagulation without necrosis (SOFT COAG), BIPOLAR coagulation, and ABLATION. Its digital interface, managed by a microcontroller, ensures accurate power delivery and operational reliability. Safety features include continuous monitoring of the neutral electrode connection and patient/plate contact, with the capability to control output functions directly from the handle, allowing surgeons to maintain focus on the surgical field.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Brands:: LED Surtron

Description

SURTRON FLASH 160HF is a High-Frequency RadioSurgical equipment which is suitable for precision monopolar and bipolar surgery and micro-surgery without tissue alterations. SURTRON FLASH 160HF can supply RF operative powers either for programmable times as short as hundreds of a seconds. Through its performances, SURTRON FLASH 160HF allows pure CUT,  cut-coagulation BLEND, incision with reduced production of eschar ENHANCED, superficial coagulation FORCED COAG, deep coagulation in the absence of necrosis SOFT COAG, BIPOLAR coagulation, and ABLATION. The digital reading of the delivered power and the oversight through a microcontroller of the operational functions assure the absolute reliability of the conditions of the operation. SURTRON FLASH 160HF allows a highly professional surgery, thanks to the user-friendly and safety solutions normally used. The connection of the neutral electrode is constantly monitored. Safety control of patient/plate contact using split neutral electrode. The possibility to control by the handle the output functions as well as the delivery of output power, allows for the implementation of the surgical operation without diverting the surgeon’s attention from the surgical field.

Key Features
  • Surgical Modes: Supports pure CUT, BLEND, ENHANCED incision, FORCED COAG, SOFT COAG, BIPOLAR coagulation, and ABLATION.

  • Programmable RF Emission: Allows RF power emissions for programmable times as short as 10 milliseconds. avrasyamed.com.tr+5Walen Tec Asia Pte Ltd+5MedicalExpo+5

  • Digital Control: Microcontroller-managed digital interface for precise power delivery and operational oversight.

  • Safety Monitoring: Continuous monitoring of neutral electrode connection and patient/plate contact using a split neutral electrode.

  • User-Friendly Operation: Control of output functions and power delivery directly from the handle, minimizing the need for the surgeon to divert attention from the surgical field.

Technical Data
  • Max output power CUT 150 W-500 Ω
  • Max output power BLEND 100 W-500 Ω
  • Max output power ENHANCED 100 W-500 Ω
  • Max output power FORCED COAG 100 W-150 Ω
  • Max output power SOFT COAG 80 W-100 Ω
  • Max output power BIPOLAR COAG 60 W-50 Ω
  • Working frequency 60 W-100 Ω
  • Working frequency 600 KHz – 4.0 MHz
  • RF power pulse emission time 10 ms – 30 sec
  • RF power pulse interval 1 – 9
  • Patient circuit F
  • Selectable input voltage 115 – 230 VAC
  • Main frequency 50 – 60 Hz
  • Electrical input power: 350 VA
  • Size WxHxD 370x144x319 mm
  • Weight 6 Kgs

 

CONTROLS
Control Plate Circuit / OC patient
Control of the emitted power
Self-diagnosis

 

SAFETY
EN60601-1
EN60601-1-2
EN60601-2-2
Electrical classification: CF

Reviews

There are no reviews yet.

Be the first to review “SURTRON FLASH 160 HF”

Your email address will not be published. Required fields are marked *

Quick Comparison

SURTRON FLASH 160 HF removeOBS-50 High Frequency Coagulator removeOBS-100C LCD Version Dual cold RF Electrosurgical Unit removeBipolar Irrigated Coagulator removeOBS-100A Monopolar Electrosurgical Unit removeDisposable ECG Monitoring Electrode remove
NameSURTRON FLASH 160 HF removeOBS-50 High Frequency Coagulator removeOBS-100C LCD Version Dual cold RF Electrosurgical Unit removeBipolar Irrigated Coagulator removeOBS-100A Monopolar Electrosurgical Unit removeDisposable ECG Monitoring Electrode remove
Image
SKUSF1033560130165-3SF1033560130165-1SF1033560130165-12SF1033560130165-7SF1033560130165-24
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad The SURTRON FLASH 160 HF is a high-frequency electrosurgical unit engineered for precision monopolar and bipolar procedures, including microsurgery, without causing tissue alterations. It offers programmable RF power emissions, enabling operations with durations as short as 10 milliseconds. The device supports various surgical modes such as pure CUT, cut-coagulation BLEND, incision with reduced eschar production (ENHANCED), superficial coagulation (FORCED COAG), deep coagulation without necrosis (SOFT COAG), BIPOLAR coagulation, and ABLATION. Its digital interface, managed by a microcontroller, ensures accurate power delivery and operational reliability. Safety features include continuous monitoring of the neutral electrode connection and patient/plate contact, with the capability to control output functions directly from the handle, allowing surgeons to maintain focus on the surgical field.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad This unit is widely used in many different sectors including plastic surgery, dermatology, ENT, Ophthalmology, somatology, gynecology, proctology, and urology.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad Unique dual radio frequency design. Combines 4Mhz and 1.7Mhz into one generator. Realizes the best operation result effectively. Suitable for  Plastic, Dermatology, ENT, Ophthalmology, Dentistry, Podiatry and Spinal surgery
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad Disposable ECG Electrodes consist of snap set, conductive gel, backing material with medical adhesive, and release film. OBS Disposable ECG Electrodes model 301 are Non-woven, Micropore fabric backing Electrodes . These electrodes are applied by or on the order of a physician on a patient’s skin, the model 301 is fit for the general electrocardiographic application of both adults and children.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
ContentSURTRON FLASH 160HF is a High-Frequency RadioSurgical equipment which is suitable for precision monopolar and bipolar surgery and micro-surgery without tissue alterations. SURTRON FLASH 160HF can supply RF operative powers either for programmable times as short as hundreds of a seconds. Through its performances, SURTRON FLASH 160HF allows pure CUT,  cut-coagulation BLEND, incision with reduced production of eschar ENHANCED, superficial coagulation FORCED COAG, deep coagulation in the absence of necrosis SOFT COAG, BIPOLAR coagulation, and ABLATION. The digital reading of the delivered power and the oversight through a microcontroller of the operational functions assure the absolute reliability of the conditions of the operation. SURTRON FLASH 160HF allows a highly professional surgery, thanks to the user-friendly and safety solutions normally used. The connection of the neutral electrode is constantly monitored. Safety control of patient/plate contact using split neutral electrode. The possibility to control by the handle the output functions as well as the delivery of output power, allows for the implementation of the surgical operation without diverting the surgeon's attention from the surgical field.
Key Features
  • Surgical Modes: Supports pure CUT, BLEND, ENHANCED incision, FORCED COAG, SOFT COAG, BIPOLAR coagulation, and ABLATION.

  • Programmable RF Emission: Allows RF power emissions for programmable times as short as 10 milliseconds. avrasyamed.com.tr+5Walen Tec Asia Pte Ltd+5MedicalExpo+5

  • Digital Control: Microcontroller-managed digital interface for precise power delivery and operational oversight.

  • Safety Monitoring: Continuous monitoring of neutral electrode connection and patient/plate contact using a split neutral electrode.

  • User-Friendly Operation: Control of output functions and power delivery directly from the handle, minimizing the need for the surgeon to divert attention from the surgical field.

Technical Data
  • Max output power CUT 150 W-500 Ω
  • Max output power BLEND 100 W-500 Ω
  • Max output power ENHANCED 100 W-500 Ω
  • Max output power FORCED COAG 100 W-150 Ω
  • Max output power SOFT COAG 80 W-100 Ω
  • Max output power BIPOLAR COAG 60 W-50 Ω
  • Working frequency 60 W-100 Ω
  • Working frequency 600 KHz – 4.0 MHz
  • RF power pulse emission time 10 ms – 30 sec
  • RF power pulse interval 1 – 9
  • Patient circuit F
  • Selectable input voltage 115 – 230 VAC
  • Main frequency 50 – 60 Hz
  • Electrical input power: 350 VA
  • Size WxHxD 370x144x319 mm
  • Weight 6 Kgs
  CONTROLS Control Plate Circuit / OC patient Control of the emitted power Self-diagnosis   SAFETY EN60601-1 EN60601-1-2 EN60601-2-2 Electrical classification: CF
  The OBS-50 is a market leader across the world due to its ease of use, high security, power on self test, full-range monitoring, remote control and precise output.
  • Power output can be controlled by the easy to use power adjustment button on the electrosurgical hand pencil which can shorten the operation time.
  • With the inbuilt memory function on the device, you can set the required function parameters then power off the unit, next time the unit is powered on, the unit the last set parameter will be displayed.
  • Output power of between 10 and 30 watts or less can be adjusted up and down by 0.1-watt increments, which is suitable for various delicate procedures.
  • It can be used with disposable dispersive electrode
 What's in the box?
  • x1 OBS-50 High-Frequency Electric Coagulator Unit
  • x1 Reusable power control electrosurgical pencil
  • x10 Non-Sterile Single-Use Short Sharp Tips
  • x10 Non-Sterile Single-Use Short Blunt Tips
  • x1 Power cord
  • x1 Instruction manual
Multiple Applications to meet your different clinic demands
Desiccation 
  • Monopolar output mode without using the dispersive electrode
  • Contact or insert into the tissue with the electrode
  • The unit produces a high-frequency current, which runs through the patient via the electrode and then returns to the unit through grounding.
  • High-frequency current vaporises the liquid inside the tissue cell therefore causing denaturation on the protein
Fulguration
  • Another monopoly output mode without using a dispersive electrode
  • Holding the electrode above the lesions rather than contact directly, will release an electric arc to the tissue.
  • Range of action in this mode is limited to the surface where the arc contacts the tissue
Coagulation
  • Suitable for hemostasis and shrinkage of tissue
  • Used in control of hemostasis
  • Suitable for more difficult cutting procedures for good hemostasis
Monopolar coagulation
  • Monopolar output mode using the dispersive electrode
  • Under this mode, the high-frequency current that is produced from the unit flows through the patient and then returns to the unit via a dispersive electrode
  • The dispense electrode can draw more high-frequency current to the electrode, making the tip of electrode produce a more powerful desiccation to the tissue.
Bipolar Coagulation
  • An Output mode in which the high-frequency current circulates between two nearby electrodes (bipolar forceps), without using the dispersive electrode.
  • In contrast to the effect of monopolar coagulation, since the high-frequency current is only circulated separately in the forceps, the bipolar coagulation effect acts only on the tissue surface, causing minimal damage to the tissue.
Standard Accessories (Can be purchased Separately)
  • Single foot switch
  • Reusable power control electrosurgical pencil
  • Reusable dispersive electrode (Patient Plate) & Cable
  • Reusable bipolar forceps & cable
  • Reusable Connecting Cable (for disposable dispersive electrode)
  • Disposable dispersive electrodes
  • Wall mounting Plate
Output Mode  Monopolar coagulation: (30W, load:1000Ω) Bipolar coagulation: (30W, load:200Ω) Technical parameters
Ambient Temperature  10°C - 40°C
RH Range ≤80%
atmospheric pressure range 50.0kPa-106.0kPa
Power supply 220/110V,50/60Hz
operating Frequency 550kHz+10%
Features
  • Clinic result proves that higher frequency can get less tissue resists nee. 4Mhz frequency can reduces heat injury a ind carbonizing to tissue at maximum. It realizes low temperature cutting.
  • The antenna pad is unnecessary for skin touch, no current goes through the body, and no possibility of burning
  • No pressure cutting and the pencil is operated easily and it's full of flexibility.
  • No carbonation, less bleeding, and no adhesions.
  • Less pain, scarring, and fast healing after operation.
Technical Parameters
Image
Product Details
OUTPUT MODE 
  • CUT - For micro-smooth cutting
  • BLEND - For cutting with coagulation
  • HEMO - For pure Hemostasis-Coagulation to control most forms of bleeding
  • FULGURATION - For desiccation or fulgurate spark-gap
  • BIPOLAR - For precise coagulation utilizing bipolar energy
INTENDED USE
  • Cutting: snoring, submucosal palatal shrinkage, traditional uvulopalatoplasty (RAUP), myringotomy with effective hemorrhage control, epistaxis treatment, turbinate shrinkage, skin incisions, biopsy, cysts, abscesses, tumors, cosmetic repairs, development of skin flaps, skin tags and blepharoplasty.
  • Blended (cutting and coagulation): snoring, submucosal palatal shrinkage, traditional uvulopalatoplasty (RAUP), myringotomy with effective hemorrhage control, epistaxis treatment, turbinate shrinkage, skin tags, papilloma keloids, keratosis, verrucae. basal cell carcinoma, nevi, fistulas, epithelioma, cosmetic repairs, cysts, abscesses, and development of skin flaps.
  • Hemostasis: control of bleeding, epilation, telangiectasia.
  • Fulguration: basal cell carcinoma, papilloma, cyst destruction, tumors, verrucae, hemostasis.
  • Bipolar: pinpoint precise coagulation, pinpoint hemostasis in any field (wet or dry), snoring, submucosal palatal shrinkage, traditional uvulopalatoplasty (RAUP), myringotomy with effective hemorrhage control, epistaxis treatment and turbinate shrinkage.
Transportation Data :
  • WxHxD:34(L)'23.5(W)*10.6(H) 49(L)*35.5(W)'31(H)cn Weight:8.2kg(NetWeight);12. cm(Generator) i(outer carton) 1kg(Gross Weight)
  • Standard Matching Accessories
  • Instruction for Use: 1pc
  • Power Cord: 1pc
  • Dual Pedal Switch: 1pc
  • Disposable ESU Pencil: 2 pes
  • Reusable Antenna Pad with cable: 1 set
  • Reusable Bipolar Forceps with Cable: 1 set
  • Reusable ESU pencil: 1 pc
  • Reusable Fine Electrode tips (Needle, curved, Needle .Ball): 7pcs
  • Disposable leep Electrode tips: 5pcs
Features

1. LED light positioned between the electrodes enhances the vision during surgery.

2. Massive area hemostasis can be performed in a short time in order to reduce intraoperative blood loss 3. Saline line and dripping device are equipped in an attempt to contain the heat on the treated tissue and avoid thermal tissue damage
Indications for Use
  • Ensure that both electrodes are in contact with the tissue to be treated. Activation and saline flow occur simultaneously.
  • Ensure that saline is flowing at the time of activation
  • These devices should never be used when:
  • There is visible evidence of damage to the exterior of the device such as cracked or damaged plastic or connector damage.
  • These devices fail the inspection described herein.
  • In the presence of flammable gases, flammable prep solutions or drapes. Oxidizing. Gases such as Nitrous Oxide (N2O), or in oxygen-riched environments.
  • Do not use monopolar electrosurgery on small appendages, as in circumcision or finger surgery.
 
Features

1. Portable and  affordable

2. Suitable for general surgery and veterinary
Technical Details
Environmental temperature range: 5°C~ 40°C
Relative moisture range: ≤80%
Atmosphere pressure range: 86.0 Kpa ~ 106.0 Kpa
Working modes:
Pure cut: 5w ~ 100w (Load:300Ω)
Blend cut: 5w ~ 50w (Load:300Ω)
Forced coagulation: 5w ~ 80w (Load:500Ω)
Soft coagulation: 5w ~ 50w (Load:500Ω)
Technology data:
Voltage: 230V±10V, 50Hz
Working frequency: 330KHz ~ 460KHz
Leakage currents to ground: Less than 0.5mA
Leakage currents to patient: Less than 0.01mA
Indications for Use:

Disposable ECG Electrodes are pre-gelled, non-sterile, single use disposable electrocardiographic electrodes which are intended for use as an accessory to ECG equipment for ECG monitoring , diagnostic procedures and can used for stress test & holter.

Instruction for Use:

1. Clean the skin area where the electrode will stick on. Make sure the skin area for sticking is intact (uninjured). 2. Connect the leadwire with the electrode. Make sure it is fastened and in good contact. 3. Tear off the release film from the bottom (the part away from metal stud) of electrode. 4. Press lightly when stick the electrodes to the skin and make sure the conductive gel and adhesive backing stick on the skin tightly. Caution

  • Don’t peel the release film from the metal stud of the electrode. It may break the structure and affect the function of electrodes.
  • ECG electrodes should only be used by or in consultation with a healthcare provider familiar with their proper placement and use.
  • ECG electrodes may damage the skin if removed carelessly.
  • ECG electrodes should be applied only to intact, clean skin (e.g., not over open wounds, lesions, or infected, or inflamed areas).
  • Do not reuse this device. It may cause infection and affect the performance of the reuse of this device.
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare