SURTRON FLASH 200
$0.00
Shipped From Abroad
The SURTRON FLASH 200 is a high-frequency electrosurgical unit designed for precision monopolar and bipolar surgeries, including microsurgical procedures, without causing tissue alterations. It offers programmable RF power emissions, allowing for operations with durations as short as 10 milliseconds. The device supports various surgical modes such as pure CUT, cut-coagulation BLEND, incision with reduced eschar production (ENHANCED), superficial coagulation (FORCED COAG), deep coagulation without necrosis (SOFT COAG), BIPOLAR coagulation, and ABLATION. Its digital interface, managed by a microcontroller, ensures accurate power delivery and operational reliability. Safety features include continuous monitoring of the neutral electrode connection and patient/plate contact, with the capability to control output functions directly from the handle, allowing surgeons to maintain focus on the surgical field.
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
SURTRON FLASH 200 is an electrosurgical equipment that is suitable for precision monopolar and bipolar surgery and micro-surgery without tissue alterations. SURTRON FLASH 200 can supply RF operative powers either for programmable times as short as hundreds of seconds. Through its performances, SURTRON FLASH 200 allows pure CUT, cut-coagulation BLEND, incision with reduced production of eschar ENHANCED, superficial coagulation FORCED COAG, deep coagulation in the absence of necrosis SOFT COAG, BIPOLAR coagulation, and ABLATION. The digital reading of the delivered power and the oversight through a microcontroller of the operational functions assure the absolute reliability of the conditions of the job. SURTRON FLASH 200 allows a highly professional surgery thanks to the user-friendly and safety solutions normally used. The connection of the neutral electrode is constantly monitored. Safety control of patient/plate contact using split neutral electrode. The possibility to control by the handle the output functions as well as the delivery of output power, allows for the implementation of the surgical operation without turning the surgeon’s attention from the surgical field.
Key Features
-
Surgical Modes: Supports pure CUT, BLEND, ENHANCED incision, FORCED COAG, SOFT COAG, BIPOLAR coagulation, and ABLATION. led.it
-
Programmable RF Emission: Allows RF power emissions for programmable times as short as 10 milliseconds.
-
Digital Control: Microcontroller-managed digital interface for precise power delivery and operational oversight.
-
Safety Monitoring: Continuous monitoring of neutral electrode connection and patient/plate contact using a split neutral electrode. led.it
-
User-Friendly Operation: Control of output functions and power delivery directly from the handle, minimizing the need for the surgeon to divert attention from the surgical field.
Technical Data
Max output power CUT 200 W- 250 Ω
Max output power BLEND 120 W- 200 Ω
Max output power ENHANCED 120 W- 250 Ω
Max output power FORCED COAG 150 W- 150 Ω
Max output power SOFT COAG 90 W-100 Ω
Max output power BIPOLAR COAG 80 W-50 Ω
Working frequency 600 KHz
RF power pulse emission time 10 ms – 30 sec
RF power pulse interval 1 – 9
Patient circuit F
Selectable input voltage 115 – 230 VAC
Main frequency 50 – 60 Hz
Electrical input power: 350 VA
Size WxHxDÂ 370x144x319 mm
Weight 6 Kgs
CONTROLS
Control Plate Circuit / OC patient
Control of the emitted power
Self-diagnosis
SAFETY
EN60601-1
EN60601-1-2
EN60601-2-2
Electrical classification: CF
Quick Comparison
SURTRON FLASH 200 remove | Electrosurgical Forceps remove | OBS-100C(I) Intelligent Electrosurgical Unit remove | Bipolar Artery Forceps remove | Disposable Subdermal Needle Electrodes remove | Arthroscopic Ablator remove | |||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | SURTRON FLASH 200 remove | Electrosurgical Forceps remove | OBS-100C(I) Intelligent Electrosurgical Unit remove | Bipolar Artery Forceps remove | Disposable Subdermal Needle Electrodes remove | Arthroscopic Ablator remove | ||||||||||||||||||||||||||||
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||||||||||||||||||||||||
SKU | SF1033560130165-19 | SF1033560130165-2 | SF1033560130165-20 | SF1033560130165-25 | SF1033560130165-13 | |||||||||||||||||||||||||||||
Rating | ||||||||||||||||||||||||||||||||||
Price |
|
|
|
|
|
| ||||||||||||||||||||||||||||
Stock | ||||||||||||||||||||||||||||||||||
Availability | ||||||||||||||||||||||||||||||||||
Add to cart | ||||||||||||||||||||||||||||||||||
Description | Shipped From Abroad
The SURTRON FLASH 200 is a high-frequency electrosurgical unit designed for precision monopolar and bipolar surgeries, including microsurgical procedures, without causing tissue alterations. It offers programmable RF power emissions, allowing for operations with durations as short as 10 milliseconds. The device supports various surgical modes such as pure CUT, cut-coagulation BLEND, incision with reduced eschar production (ENHANCED), superficial coagulation (FORCED COAG), deep coagulation without necrosis (SOFT COAG), BIPOLAR coagulation, and ABLATION. Its digital interface, managed by a microcontroller, ensures accurate power delivery and operational reliability. Safety features include continuous monitoring of the neutral electrode connection and patient/plate contact, with the capability to control output functions directly from the handle, allowing surgeons to maintain focus on the surgical field.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Mainly used for bipolar subtle coagulation in microsurgery, neurosurgery, spine surgery, and medical cosmetology
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Portable in size, available in both monopolar and bipolar modes, convenient handle power control and memory function, suitable for microsurgery, gynecology, and arthroscopy.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| ||||||||||||||||||||||||||||
Content | SURTRON FLASH 200 is an electrosurgical equipment that is suitable for precision monopolar and bipolar surgery and micro-surgery without tissue alterations. SURTRON FLASH 200 can supply RF operative powers either for programmable times as short as hundreds of seconds. Through its performances, SURTRON FLASH 200 allows pure CUT, cut-coagulation BLEND, incision with reduced production of eschar ENHANCED, superficial coagulation FORCED COAG, deep coagulation in the absence of necrosis SOFT COAG, BIPOLAR coagulation, and ABLATION. The digital reading of the delivered power and the oversight through a microcontroller of the operational functions assure the absolute reliability of the conditions of the job. SURTRON FLASH 200 allows a highly professional surgery thanks to the user-friendly and safety solutions normally used. The connection of the neutral electrode is constantly monitored. Safety control of patient/plate contact using split neutral electrode. The possibility to control by the handle the output functions as well as the delivery of output power, allows for the implementation of the surgical operation without turning the surgeon's attention from the surgical field.
Key Features
Technical DataMax output power CUT 200 W- 250 Ω Max output power BLEND 120 W- 200 Ω Max output power ENHANCED 120 W- 250 Ω Max output power FORCED COAG 150 W- 150 Ω Max output power SOFT COAG 90 W-100 Ω Max output power BIPOLAR COAG 80 W-50 Ω Working frequency 600 KHz RF power pulse emission time 10 ms – 30 sec RF power pulse interval 1 – 9 Patient circuit F Selectable input voltage 115 – 230 VAC Main frequency 50 – 60 Hz Electrical input power: 350 VA Size WxHxD 370x144x319 mm Weight 6 Kgs CONTROLS Control Plate Circuit / OC patient Control of the emitted power Self-diagnosis SAFETY EN60601-1 EN60601-1-2 EN60601-2-2 Electrical classification: CF |
Features
|
Key FeaturesOBS-100 Electrosurgical Generator with state-of-art technology offers superb performance on the electro-surgery, and shows remarkable safety, reliability and convenience. 1. Two levels of coagulation: pinpoint coagulation and fulguration Pinpoint coagulation provides precise control of bleeding in localized areas. Fulguration provides greater control of bleeding in highly vascular over-surface areas. 2. Presets The unit incorporates as many as ten user-defined presets for easy recall of frequency and settings. 3. Isolated RF output for Cut, Blend, and Coag modes This minimizes the potential of alternate site burns. 4. Ground Referenced RF output for Fulguration modes 5. Self-diagnostics These diagnostics continually monitor the unit to ensure proper performance. If the diagnostics is unsuccessful, the warning tones can be heard.Technical parameters:
| Features1. Intended for ablation,tissue modification, and coagulation of soft tissue in arthroscopic procedures such as hip, shoulder, ankle, wrist, elbow, and knee. 2. The Extending shaft enables good visualization and easy insertion through subcutaneous tissue,and well insulated coating guarantee its safety and reliability. 3.Irrigation/suction solution is available with a cannula and an adjustable flow control valve. 4. Tips in different shapes and angles fit in particular arthroscopic procedures. 5. Compatible with most electrosurgical generators. Use IndicationThis device should never be used when:
| ||||||||||||||||||||||||||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||
Additional information |
Reviews
There are no reviews yet.