/

Visible Spectrophotometer, Band Width 5nm

$0.00

Shipped From Abroad

Visible Spectrophotometer with a 5 nm bandwidth measures the light absorption of a sample within the visible spectrum (400-800 nm). The 5 nm bandwidth offers a balance between resolution and sensitivity, making it suitable for a variety of applications in research and chemical analysis.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130127-54
Brands:: Scitek

Description

Visible Spectrophotometer Features:

SP-VP722 spectrophotometer is a compact and easy-to-operate instrument. We can apply it to the measurement of transparent materials’ transmittance and absorbance and the concentration’s direct reading. They are widely used in clinical testing, petrochemical, health medicine, environmental monitoring, biochemistry and other fields.

  1. Aspherical light source optics, curny-terner configuration diffraction grating monochromator.
  2. Simple and clear keyboard operation, easy to realize automatic 0%T and 100%T adjustment T/A transformation, coefficient setting, and concentration direct readout function.
  3. RS232 parallel interface.
  4. With RS232 serial interface, optional micro-printer to print data directly.
  5. Spacious sample chamber, 4-position cuvette holder, can be adapted to 1-5 cm optical path rectangular cuvettes.
Visible Spectrophotometer Specifications:
Model SP-VP722
Display Mode 4 digits LED
Wavelength Range 325-1000nm
Light Source Lamp Halogen-Tungsten Lamp 20W/12V
Wavelength Accuracy ±2 nm
Wavelength Reproducibility 1 nm
Band Width 5 nm
Photometric Accuracy ±0.5%(T)(SRM930D)
Photometric Reproducibility 0.2%(T)
Stray Light ≤0.2%(T)
Noise ±0.5%(T)
Scale Display TRANS: 0-199.9%
ABS -3.299
FACT 1-9999
CONC 0-9999
Power Requirement 220V/110V±10%; 50/60 Hz
Interface RS232 serial & parallel l interface
Print Serial printer/general printer (windows compatible; use software package)
Size(W×D×H)(mm) 450×420×280
Shipping Size(W×D×H)(mm) 460x430x320
N.W./G.W. (kg) 7/10

Reviews

There are no reviews yet.

Be the first to review “Visible Spectrophotometer, Band Width 5nm”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsVisible Spectrophotometer, Band Width 5nm removeSkyla HB1 POC Clinical Chemistry Auto Analyzer removeAlcohol Pad Per Pack remove8 Bucket Centrifuge removeErma B-111 Bilirubin Meter removeAvalun LabPad Device remove
NameVisible Spectrophotometer, Band Width 5nm removeSkyla HB1 POC Clinical Chemistry Auto Analyzer removeAlcohol Pad Per Pack remove8 Bucket Centrifuge removeErma B-111 Bilirubin Meter removeAvalun LabPad Device remove
ImageAvalun Labpad machine
SKUSF1033560130127-54SF1033560060-1SF1033560084-64SF1033560084-114SF1033560084-6SF1033560084-65
Rating
Price

$0.00

$0.00

$4.25

$72.50

$715.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From AbroadVisible Spectrophotometer with a 5 nm bandwidth measures the light absorption of a sample within the visible spectrum (400-800 nm). The 5 nm bandwidth offers a balance between resolution and sensitivity, making it suitable for a variety of applications in research and chemical analysis.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The skyla HB1 Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. The portable design of the clinical chemistry analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
Classification: Laboratory Centrifuge
Brand Name: xiangtian
Model Number: 800-1
Place of Origin: Jiangsu, China
Time range: 0-60min
Max speed: 4000r/min
Max RCF: 1790xg
Capacity: 20ml*6
  Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Aboard  The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Visible Spectrophotometer Features:
SP-VP722 spectrophotometer is a compact and easy-to-operate instrument. We can apply it to the measurement of transparent materials' transmittance and absorbance and the concentration's direct reading. They are widely used in clinical testing, petrochemical, health medicine, environmental monitoring, biochemistry and other fields.
  1. Aspherical light source optics, curny-terner configuration diffraction grating monochromator.
  2. Simple and clear keyboard operation, easy to realize automatic 0%T and 100%T adjustment T/A transformation, coefficient setting, and concentration direct readout function.
  3. RS232 parallel interface.
  4. With RS232 serial interface, optional micro-printer to print data directly.
  5. Spacious sample chamber, 4-position cuvette holder, can be adapted to 1-5 cm optical path rectangular cuvettes.
Visible Spectrophotometer Specifications:
Model SP-VP722
Display Mode 4 digits LED
Wavelength Range 325-1000nm
Light Source Lamp Halogen-Tungsten Lamp 20W/12V
Wavelength Accuracy ±2 nm
Wavelength Reproducibility 1 nm
Band Width 5 nm
Photometric Accuracy ±0.5%(T)(SRM930D)
Photometric Reproducibility 0.2%(T)
Stray Light ≤0.2%(T)
Noise ±0.5%(T)
Scale Display TRANS: 0-199.9%
ABS -3.299
FACT 1-9999
CONC 0-9999
Power Requirement 220V/110V±10%; 50/60 Hz
Interface RS232 serial & parallel l interface
Print Serial printer/general printer (windows compatible; use software package)
Size(W×D×H)(mm) 450×420×280
Shipping Size(W×D×H)(mm) 460x430x320
N.W./G.W. (kg) 7/10
Skyla HB1 Clinical Chemistry Analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. HB1 provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. Only needs 200µl of blood (whole blood, serum or plasma is accepted.) and no sample preparation is required. All steps are designed automatically from checking the validity of reagent discs and cartridges to printing the results. Over 30 test parameters are allowed with fast analysis and results in 15 minutes. Internal Quality Control (IQC) with self-calibration of optical system, chemicals stability and interference alerts functions monitor and ensure the results with high accuracy. Available Test Panels
  • Renal Function - BUN, CREA eGFR
  • Liver Function - ALB, TP, ALP, ALT, AST, TBIL, DBIL, GGT, LDH A/G#, GLOB#, IBIL
  • Lipid Metabolism - TG, TC, HDL LDL#, VLDL
  • Pancreatitis Markers - AMY, LIPA
  • Carbohydrate Metabolism and Others - GLU , CPK, UA, LAC
  • Inflammatory Markers - CRP
  • Electrolyte - Na, K, Cl, Ca, PHOS, Mg, tCO2
SPECIFICATION Principle
  • Colormetric System : LEDs 340nm~940nm wavelength
Sample & Panel
  • Test Profiles : Panels
  • Measurement Time - Panel: up to 15 tests/ 15 min
  • Sample Type & Volume : 200 μl whole blood (PCV<60%), plasma, serum 
Device
  • User Interface : 5 inch color LCD touch screen
  • Internal Memory : Store up to 50,000 analysis results
  • Printer : Built in thermal printer or external USB printer (PCL 3GUI)
  • USB Socket : USB type A (Host) for external USB Printer, USB flash drive (FAT) or external barcode scanner
  • Data transmission to PC : RS232 serial port or RJ45 (LAN)
  • Dimensions : 233 (W) X 285 (D) X 300 (H) mm
  • Weight : 5.5 kg
Operating Condition
  • Temperature / Humidity : 10 to 32˚C / 5 to 90 %
 
Click Here To Download Catalogue
Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use. Size and packing of Medical Alcohol pad:
  • Pad Size: Unfolded: 30 x 60 mm (other size can be request ).
  • Folded: 30x30 mm, 30 x 35mm,can be 2ply or 4ply ( other size, ply can be request ).
  • Aluminum Package: 60 x 50 mm , 50 x 50mm approximate ( other size can be request ).
  • Packing: 100/200 pcs per inner box, 50/ 100 boxes per carton(packing can be request).
Use of Medical Alcohol pad:
  • For cleaning prior to injection or to disinfect the hurted skin for family and medical treatment organization use.
  • For preparation and immediate disinfection of skin, wound area orr Instrument and utensil.
Notice of Medical Alcohol pad:
  • Not for eyes;
  • keep out of reach of children;
  • For external use only;
  • please stop using if you feel allergic or amyctic
Materials - Non-Woven Fabric
Trademark - OEM/ODM
Specification - CE&ISO13485
   
800-1  electric centrifuge is widely used in hospitals, chemical and Biological Chemistry Laboratory for serum, plasma, immune qualitative analysis experiment. Has beautiful shape, large capacity, small volume, complete function. Its performance is stable, the speed is adjustable and can automatically adjust the balance, low temperature, high efficiency and wide applicability and advantages. Technical Specifications:
Type No.
800-1
Power  source
220V 50HZ     110V  60HZ
Speed Range (rpm)
0~4000(rpm)
Time Range(min)
0-60min
Capacity (ml)
20(ml)×6
Maximum centrifugal force(xg)
1790(xg)
Package Size (cm)
29*29*26
 
Click Here To Download Catalogue
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin. Feature
  • Auto zero function: Manual blanking not required
  • Dual wavelength measurement system:
  • 2 wave lengths 455nm and 575nm
  • Plays major role to remove the interference caused due to Hemolysis & turbidity of sample
  • LED Light source:
  • LED does not require replacement as it lasts longer
  • As compared to Lamp, LED are more suitable as there is no intensity fluctuations
  • No warm up time required.
  • Flexible unit selection:
  • Two units either mg/dl or umol/L are selectable, ease of reporting
  • Compact slot for Capillary:
  • Accuracy of results are directly related to proper alignment of Capillary
  • B-111 has the easiest mode to ensure precise values
  • Data transfer:
  • External device can be connected to instrument through RS232 por
  • USB port
Technical Specification
  • Light source - LED
  • Wavelength - 455nm and 575nm
  • Net weight - 1kg
  • Measuring range - 0-30 mg/dl , 510 umol/L
  • Display - 16×2 LCD module with backlight
  • Auto calibration - Yes
  • Sample type - Serum or plasma
  • Sample volume - 40-80μL
  • Test time - <5sec
  • Units - mg/dl or umol/L
  • Dimensions - 150 (W) × 115 (H) × 190 (D) mm
  • Interface - RS232
  • Reading cuvette - Heparinized micro capillary holder
  • Storage temperature - 15-40°c
  • Power supply - DC 9V(DC adapter)
  • Power consumption - <2W
The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes.
  • User-friendly: the LabPad® INR is designed to be easy to use especially thanks to its 3D-shaped microcuvette that only requires a small drop of blood from a fingertip. Thanks to the color screen, both measurement steps and browsing the list of results are easy to visualize.
  • Quick and reliable: the reliability of INR results is obtained by quality controls that are performed automatically before each measurement. In less than one minute, you can see if you are in your therapeutic range.
  • Connected: the result obtained after performing the test can be transferred to healthcare professionals in charge of your treatment monitoring. This result is complementary to the pie charts and trend reports directly displayed on the LabPad® INR to help you monitoring your treatment
 
Click Here To Download Catalogue
   
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare