CARBON MONOXIDE MONITORING SYSTEM (AX60+ CO)

$0.00

Shipped From Abroad

The Ax60+ CO protects users in plant rooms, parking garages and anywhere that carbon monoxide can collect. The Ax60+ CO also can be used for online cylinder filling, to protect divers from compressed air contaminated with carbon monoxide related to compressor maintenance or contamination at the compressor inlet.

The Ax60+ CO benefits from the ability to operate as a single sensor and alarm or as part of a system of up to 4 sensors. Each system can also be composed of Ax60+: O2 sensors and Ax60+ CO2 sensors so it can fulfil multiple application needs.

Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130141-1
Brands:: Analox

Description

 

Key Features
  • Ambient CO monitoring
  • Online CO monitoring
  • Can be used with Nitrogen (N2) background gasses or, with calibration, can be used with Helium (He) background gasses
  • Has up to 3 user configurable alarms
  • Can operate as a stand alone sensor or as part of a larger system
  • Compatible with the rest of the Ax60+ range

 

Click here to download Quick Start Guide
Click here to download Manual
Click here to download Service Manual

Reviews

There are no reviews yet.

Be the first to review “CARBON MONOXIDE MONITORING SYSTEM (AX60+ CO)”

Your email address will not be published. Required fields are marked *

Quick Comparison

CARBON MONOXIDE MONITORING SYSTEM (AX60+ CO) removeVENUS SOLO OEM SENSOR removeAx60+ Kiosk removeMeasuring Beaker 250ml removeAtmosphere Protection Module removeDISSUB ANALYSER remove
NameCARBON MONOXIDE MONITORING SYSTEM (AX60+ CO) removeVENUS SOLO OEM SENSOR removeAx60+ Kiosk removeMeasuring Beaker 250ml removeAtmosphere Protection Module removeDISSUB ANALYSER remove
Image
SKUSF1033560130141-1SF1033560130141-15SF1033560130141-6SF1033560084-153SF1033560130141-16SF1033560130141-17
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad

The Ax60+ CO protects users in plant rooms, parking garages and anywhere that carbon monoxide can collect. The Ax60+ CO also can be used for online cylinder filling, to protect divers from compressed air contaminated with carbon monoxide related to compressor maintenance or contamination at the compressor inlet.

The Ax60+ CO benefits from the ability to operate as a single sensor and alarm or as part of a system of up to 4 sensors. Each system can also be composed of Ax60+: O2 sensors and Ax60+ CO2 sensors so it can fulfil multiple application needs.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Key Features
  • Single gas (user defined)
  • Backward compatible with ADC’s ‘Eclipse’
  • Linearised Output
  • Continuous status signal to check device health
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Key Features
  • Low maintenance
  • Quick Connect System
  • Pre-wired, ready to go
  • Can support up to 4 alarm units
  • Push button for unit testing
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock • Height: 95mm • Width: 85mm • Diameter: 75mm • Volume: 250ml
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Key Features
  • Flexible to meet your specific needs and ensures you meet current legislation
  • Measures up to 2 gasses with a choice of; O2 (oxygen), CO2 (carbon dioxide) and R134a (refrigerants). The APM will soon be able to measure VOCs (volatile organic compounds)
  • Uses MODBUS RTU communications protocol
  • Temperature compensated sensors with PressureSync technology
  • Fitted with 2 relays
  • Compatible with the Analox Distributed Atmosphere Monitoring solution (DAMS)
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Key Features
  • Proven hyperbaric sensing capability
  • You have the ability to change sensors and maintain the unit in the dockyard, reducing costs and downtime
  • Backlit display for low/no light situations
  • Portable and lightweight making it easy to use around the submarine
  • Externally accessible batteries making for more convenient and safer changing
  • MODBUS RTU over RS485 digital communications, allowing for easy incorporation into your existing platform management system, including JANUS enabled underwater communication networks
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
https://youtu.be/--wsZFTYVWs?si=nI8q1AThpkBD4yNv https://youtu.be/Bi7CmSLIIbA?si=dVXlyZaRw893no_T  
Key Features
  • Ambient CO monitoring
  • Online CO monitoring
  • Can be used with Nitrogen (N2) background gasses or, with calibration, can be used with Helium (He) background gasses
  • Has up to 3 user configurable alarms
  • Can operate as a stand alone sensor or as part of a larger system
  • Compatible with the rest of the Ax60+ range
 
Click here to download Quick Start Guide
Click here to download Manual
Click here to download Service Manual
Description
The Venus Solo OEM sensor is a self-contained unit designed for integration into other manufacturers’ equipment and provides a measurement of gas concentration according to specific user requirements. These GFC (Gas Filter Correlation) sensors generate a signal proportional to the infrared absorption of the measured gas. Providing the gas concentration lies within the designed range of the sensor, the signal is periodically compared with a reference gas. Gas concentrations are indicated through the non-linearised analogue signal output. Gas connections to and from the sensor are via suitable fittings on the gas measuring cell. The Venus Solo OEM Series sensors electrical supply is designed to accept 24V DC (3amp max). Our Venus Solo OEM sensor uses GFC (Gas Filter Correlation) technology to give highly accurate gas measurements. The Venus Solo can be integrated into your own gas analyzer or management system and offers the user a 0-2.5v analogue output.

The sensor is currently available as either: Carbon dioxide (CO2), carbon monoxide (CO), nitrous oxide (N20), methane (CH4) or nitric oxide (NO). If your application requires a different gas, just let us know and we can customise it to your needs. The Venus Solo is used in Military applications to protect submariners from carbon monoxide (CO) exposure.  

Technical Specification
Venus Solo
CO2 MONITOR & ALARM DESIGNED FOR KIOSKS

The Ax60+ Kiosk is a CO2 monitor and alarm specifically designed by Analox to alert personnel to a build up/leak of CO2 using a state-of-the-art infrared sensor. The alarm provides both audio and visual alerts in the case of increased levels of carbon dioxide (CO2). Up to four alarms can be added as needed and the unit does not need periodic calibration.

CO2 monitoring with the AX60+ Kiosk
The Ax60+ Kiosk is a smaller version of the popular Ax60+ carbon dioxide (CO2) monitor. It is simple to wall mount in the area where carbon dioxide (CO2) is stored or piped. The Ax60+ Kiosk sensor needs to be installed at a height of 12-18 inches (305-457mm) above the floor – this is because the carbon dioxide (CO2) that leaks from a gas cylinder is denser than ambient air and can collect at low levels. The alarm should be located above the sensor at about head height or at the entrance to the kiosk.  
Technical Specification
Sensor Unit
Measuring beaker • Lined with metric increments up to 200ml • Material: Borosilicate glass • Pouring lip • Great for molecular mixology and molecular gastronomy • Height: 95mm • Width: 85mm • Diameter: 75mm • Volume: 250ml
Descriptions
The Analox APM (Atmosphere Protection Module) is a configurable modular system which has the ability to monitor up to 2 gasses. This unique solution can be used as a stand alone atmosphere monitor or it can be integrated into existing PMS systems.  
Technical Specifications
System Specifications
Operating Temperature 0°C to +45°C +32°F to +113°F
Operating pressure 700 to 1300mBar
Humidity Range 0 to 95% RH
Power 24vDC (nominal) as standard
Communications MODBUS RTU
Relays 2 as standard
Calibration interval Before mission and / or every 3 months
Sensor Unit
Sensor type Range Danger
CO2 NDIR 0 to 5% / 0 to 30mBar Toxic
O2 (Depleted) Electrochemical 0 to 25% / 0 to 2500mBar Asphyxiation
O2 (enriched) Electrochemical 0 to 25% / 0 to 2500mBar Fire/explosion
R134a NDIR 0 to 1000ppm Asphyxiation
VOCs PID 0 to 20ppm Toxic
Click here to download Data Sheet
Download Pumped Detectors Technical Manual
Description

The Sub Mk3P Continuous Gas Monitor from Analox is designed specifically to monitor life support gasses aboard a submarine in the event of a distressed submarine (DISSUB) situation.

Portable and lightweight, the Sub Mk3P monitor provides crucial information to the senior survivor about the state of the atmosphere inside the submarine during a time of crisis. This information helps that officer make one of the most challenging decisions any submariner ever has to make – attempt to escape the submarine or wait for rescue teams.
Technical Specification

Temperature & Humidity Sensor

Main Unit
Battery power 4 x ‘D’ alkaline cells (Hyperbaric)
External power 24V dc (9-36V dc), <0.5A
Backup batteries 2 x LR43 alkaline manganese cells
Displays 6 x 4 character LCD, with symbols and LED backlights
Operating temperature -5 to 50°C
Storage temperature -5 to 50°C
Operating pressure 0.7 to 10barA
Operating humidity 0 to 100%RH (Non-condensing)
Standards/ compliance NATO STANAG 1476:2014 ANEP/MNEP 85 & 86 (2014) DEF STAN 59-411:2014 (EMC) IACs E10:2014 (MarED) type tested IP65 CE marked (RoHS)"
Dimensions (W, H, D) 240mm x 198mm x 127mm
Weight 2kg with batteries installed
O2 Sensor
Range 0 to 2000mbar pO2
Accuracy ±10mbar (0 to 300mbar pO2) ±50mbar (300 to 2000mbar pO2)
Response time (t90) 20s
Detection mode Electro-chemical
Shelf life (in sealed packaging) 6 months
Expected life (in air) 12 months
CO2 Sensor
Range 0 to 100mbar pCO2
Accuracy ±10mbar
Response time (t90) 60s
Detection mode Infrared
Expected life (in air) 5 years
Pressure Sensor
Range 0.7 to 10barA (-3 to 90MSW or -10 to 300FSW)
Accuracy (including annual drift) -0.07bar +0.04bar
Response time (t90) <1s
Detection mode Piezoresistive
Expected life (in air) >12 months (Replaced as a part of the O2sensor)
Click here to download Data Sheet
Click here to download Technical Manual
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare