SURTRON FLASH 120

$0.00

Shipped From Abroad

SURTRON FLASH 120 is a high-frequency electrosurgical unit offering precise monopolar and bipolar cutting, coagulation, and ablation modes, ideal for minor to medium surgeries with digital control and safety features.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Brands:: LED Surtron

Description

SURTRON FLASH 120 is an electrosurgical equipment that is suitable for precision monopolar and bipolar surgery and micro-surgery without tissue alterations. SURTRON FLASH 120 can supply RF operative powers either for programmable times as short as hundreds of a seconds. Through its performances, SURTRON FLASH 120 allows pure CUT,  cut-coagulation BLEND, incision with reduced production of eschar ENHANCED, superficial coagulation FORCED COAG, deep coagulation in the absence of necrosis SOFT COAG, BIPOLAR coagulation, and ABLATION. The digital reading of the delivered power and the overseeing through a microcontroller of the operational functions, assure the absolute reliability of the conditions of the job. SURTRON FLASH 120 allows a highly professional surgery thanks to the user-friendly and safety solutions normally used. The connection of the neutral electrode is constantly monitored. Safety control of patient/plate contact using split neutral electrode. The possibility to control by the handle the output functions as well as the delivery of output power, allows to implementation of the surgical operation without turning the surgeon’s attention away from the surgical field.

Key Features
  • Operating Modes: Supports multiple modes, including pure CUT, cut-coagulation BLEND, incision with reduced eschar production (ENHANCED), superficial coagulation (FORCED COAG), deep coagulation without necrosis (SOFT COAG), BIPOLAR coagulation, and ABLATION. MedicalExpo+2pekamol.com+2Schuco+2

  • Digital Interface: Equipped with a microcontroller for digital reading of delivered power and monitoring of operational functions, ensuring reliable performance. Schuco

  • Safety Measures: Features patient/plate circuit monitoring, output power monitoring, and self-check control. The connection of the neutral electrode is constantly monitored, with safety control of patient/plate contact using a split neutral electrode.

  • Underwater Cutting and Coagulation: Capable of performing procedures in wet environments, expanding its range of applications.

 

Technical Data
  • Max output power CUT 120 W-250 Ω
  • Max output power BLEND 90 W-200 Ω
  • Max output power ENHANCED 90 W-250 Ω
  • Max output power FORCED COAG 80 W-150 Ω
  • Max output power SOFT COAG 60 W-100 Ω
  • Max output power BIPOLAR COAG 60 W-50 Ω
  • Working frequency 600 KHz
  • RF power pulse emission time 10 ms – 30 sec
  • RF power pulse interval 1 – 9
  • Patient circuit F
  • Selectable input voltage 115 – 230 Vac
  • Mains frequency 50 – 60 Hz
  • Electrical input power 350 VA
  • Size WxHxD 370x144x319 mm
  • Weight 6 Kgs

 

CONTROLS

  • Control Plate Circuit / OC patient
  • Control of the emitted power
  • Self-diagnosis

 

SAFETY

  • EN60601-1
  • EN60601-1-2
  • EN60601-2-2
  • Electrical classification: CF
  • MDR 2017/745/UE Class: II b

Reviews

There are no reviews yet.

Be the first to review “SURTRON FLASH 120”

Your email address will not be published. Required fields are marked *

Quick Comparison

SURTRON FLASH 120 removeBipolar Artery Forceps removeDisposable Skin Stapler removeReusable Electrosurgical Pencil removeBipolar Irrigated Coagulator removeSS-100 Smoke Evacuation System remove
NameSURTRON FLASH 120 removeBipolar Artery Forceps removeDisposable Skin Stapler removeReusable Electrosurgical Pencil removeBipolar Irrigated Coagulator removeSS-100 Smoke Evacuation System remove
Image
SKUSF1033560130165-20SF1033560130165-21SF1033560130165-11SF1033560130165-12SF1033560130165-9
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad SURTRON FLASH 120 is a high-frequency electrosurgical unit offering precise monopolar and bipolar cutting, coagulation, and ablation modes, ideal for minor to medium surgeries with digital control and safety features.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Sterile Disposable Skin Stapler is a disposable equipment that applies to skin sutures during general surgical operation, Cardiothoracic Surgery, plastic surgery, neurosurgery operation, gynecologic surgery, burn surgery, emergency operation, and field rescue. It can be used in operating room, delivery room, emergency department, outpatient surgery, and clinics.Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad

The SS-100 Smoke Evacuation System is designed to protect medical staff and patients from harmful surgical smoke generated during electrosurgical procedures

Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
ContentSURTRON FLASH 120 is an electrosurgical equipment that is suitable for precision monopolar and bipolar surgery and micro-surgery without tissue alterations. SURTRON FLASH 120 can supply RF operative powers either for programmable times as short as hundreds of a seconds. Through its performances, SURTRON FLASH 120 allows pure CUT,  cut-coagulation BLEND, incision with reduced production of eschar ENHANCED, superficial coagulation FORCED COAG, deep coagulation in the absence of necrosis SOFT COAG, BIPOLAR coagulation, and ABLATION. The digital reading of the delivered power and the overseeing through a microcontroller of the operational functions, assure the absolute reliability of the conditions of the job. SURTRON FLASH 120 allows a highly professional surgery thanks to the user-friendly and safety solutions normally used. The connection of the neutral electrode is constantly monitored. Safety control of patient/plate contact using split neutral electrode. The possibility to control by the handle the output functions as well as the delivery of output power, allows to implementation of the surgical operation without turning the surgeon's attention away from the surgical field.
Key Features
  • Operating Modes: Supports multiple modes, including pure CUT, cut-coagulation BLEND, incision with reduced eschar production (ENHANCED), superficial coagulation (FORCED COAG), deep coagulation without necrosis (SOFT COAG), BIPOLAR coagulation, and ABLATION. MedicalExpo+2pekamol.com+2Schuco+2

  • Digital Interface: Equipped with a microcontroller for digital reading of delivered power and monitoring of operational functions, ensuring reliable performance. Schuco

  • Safety Measures: Features patient/plate circuit monitoring, output power monitoring, and self-check control. The connection of the neutral electrode is constantly monitored, with safety control of patient/plate contact using a split neutral electrode.

  • Underwater Cutting and Coagulation: Capable of performing procedures in wet environments, expanding its range of applications.

 
Technical Data
  • Max output power CUT 120 W-250 Ω
  • Max output power BLEND 90 W-200 Ω
  • Max output power ENHANCED 90 W-250 Ω
  • Max output power FORCED COAG 80 W-150 Ω
  • Max output power SOFT COAG 60 W-100 Ω
  • Max output power BIPOLAR COAG 60 W-50 Ω
  • Working frequency 600 KHz
  • RF power pulse emission time 10 ms – 30 sec
  • RF power pulse interval 1 – 9
  • Patient circuit F
  • Selectable input voltage 115 – 230 Vac
  • Mains frequency 50 – 60 Hz
  • Electrical input power 350 VA
  • Size WxHxD 370x144x319 mm
  • Weight 6 Kgs
  CONTROLS
  • Control Plate Circuit / OC patient
  • Control of the emitted power
  • Self-diagnosis
  SAFETY
  • EN60601-1
  • EN60601-1-2
  • EN60601-2-2
  • Electrical classification: CF
  • MDR 2017/745/UE Class: II b
Features
  • Concise and reasonable design, which is easy and convenient to operate.
  • Safe and efficient for surgery, and the needle could be withdrawn fluently and accurately.
  • Smooth and beautiful suture, small and micro healing scar.
  • There's good compatibility with tissues and less inflammatory response.
  • It's easy and convenient to take out the stitches, which will promote wound healing.
  • Sterile Disposable Skin Stapler reduces the patient's pain and improves operation efficiency.
Features
  • High-quality tried-and-tested materials guarantee a long service life for OBS reusable electrosurgical pencils.
  • Material is durable for high temperature and high press disinfection for more than 30 times.
  • Cost compared to disposable instruments
  • The initial cost of the reusable electrosurgical pencil is easily recouped after only a fraction of the expected number of uses and compares favorably to the cost of disposable pencils.
Features

1. LED light positioned between the electrodes enhances the vision during surgery.

2. Massive area hemostasis can be performed in a short time in order to reduce intraoperative blood loss 3. Saline line and dripping device are equipped in an attempt to contain the heat on the treated tissue and avoid thermal tissue damage
Indications for Use
  • Ensure that both electrodes are in contact with the tissue to be treated. Activation and saline flow occur simultaneously.
  • Ensure that saline is flowing at the time of activation
  • These devices should never be used when:
  • There is visible evidence of damage to the exterior of the device such as cracked or damaged plastic or connector damage.
  • These devices fail the inspection described herein.
  • In the presence of flammable gases, flammable prep solutions or drapes. Oxidizing. Gases such as Nitrous Oxide (N2O), or in oxygen-riched environments.
  • Do not use monopolar electrosurgery on small appendages, as in circumcision or finger surgery.
Experts have identified harmful smoke which contains a variety of toxic gases and vapors will occur during electrosurgical operation. Medical staff and patients exposure to the smoke in large may cause viral contamination,respiratory problems,nausea and burning eyes.To use a smoke evacuation system is the most effective way of protecting operating room staff and patients from hazards.
 
Features
  • Effective smoke removal: Captures toxic gases and vapors.
  • Compact and portable: Weighs 3.5 kg with a trolley cart for easy mobility.
  • Quiet operation: Works at 55 dB.
  • High efficiency: Processes 3.5-4.2 cubic meters of smoke per hour.
  • Automatic startup: Can be activated by an internal sensor or foot switch
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare