/ /

AB Diagnostic Toxo Ab Igm Elisa Kit

$0.00

In stock

Abia Toxo Ab IgM is an enzyme immunoassay for the quantitative determination of thyroid-stimulating hormone (TSH) concentration in human serum. The assay is intended for aid in the assessment of thyroid status and diagnosis of thyroid disease. For professional use only.

Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.

SF1033560084-277
Brands:: Ab Diagonstic
Brands

Description

Abia TSH is an enzyme immunoassay for the quantitative determination of thyroid-stimulating hormone (TSH) concentration in human serum. The assay is intended for aid in the assessment of thyroid status and diagnosis of thyroid disease. For professional use only.

Abia Toxo Ab IgM DK.303.01.3:

Toxo Ab IgM coated plate: 1 plate
Conjugate: 6 ml
Calibrator 0: 2 ml
Calibrator 1: 0.5 ml
Calibrator 2: 0.5 ml
Calibrator 3: 0.5 ml
Calibrator 4:0.5 ml
Calibrator 5: 0.5 ml
Control serum: 0.5 ml
Washing solution (concentrated 25-fold): 50 ml
TMB/substrate solution: 12 ml
Stopping reagent 0.2M H2SO4: 25 ml
Protective film: 1
Plastic dish: 2
Plastic zip-lock bag: 1

Reviews

There are no reviews yet.

Be the first to review “AB Diagnostic Toxo Ab Igm Elisa Kit”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsAB Diagnostic Toxo Ab Igm Elisa Kit removeDiscover 14 Panel Cup with Adulterants Per Pack removeErma B-111 Bilirubin Meter remove8 Bucket Centrifuge removeTest Strip for ApexBio HemoSmart Gold Hemoglobin Meter removeiSED Fully Automated ESR Analyzer remove
NameAB Diagnostic Toxo Ab Igm Elisa Kit removeDiscover 14 Panel Cup with Adulterants Per Pack removeErma B-111 Bilirubin Meter remove8 Bucket Centrifuge removeTest Strip for ApexBio HemoSmart Gold Hemoglobin Meter removeiSED Fully Automated ESR Analyzer remove
ImageDrug Test Cup
SKUSF1033560084-277SF1033560084-28SF1033560084-6SF1033560084-114SF1033560084-30SF1033560084-129
Rating
Price

$0.00

$0.00

$715.00

$72.50

$9.50

$0.00

Stock
Availability
Add to cart

DescriptionIn stock Abia Toxo Ab IgM is an enzyme immunoassay for the quantitative determination of thyroid-stimulating hormone (TSH) concentration in human serum. The assay is intended for aid in the assessment of thyroid status and diagnosis of thyroid disease. For professional use only.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self contained and the entire cup is tamper resistant. Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Aboard  The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
Classification: Laboratory Centrifuge
Brand Name: xiangtian
Model Number: 800-1
Place of Origin: Jiangsu, China
Time range: 0-60min
Max speed: 4000r/min
Max RCF: 1790xg
Capacity: 20ml*6
  Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock Twenty Five (25) Test Strip per Pack

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
ContentAbia TSH is an enzyme immunoassay for the quantitative determination of thyroid-stimulating hormone (TSH) concentration in human serum. The assay is intended for aid in the assessment of thyroid status and diagnosis of thyroid disease. For professional use only. Abia Toxo Ab IgM DK.303.01.3:
Toxo Ab IgM coated plate: 1 plate Conjugate: 6 ml
Calibrator 0: 2 ml
Calibrator 1: 0.5 ml
Calibrator 2: 0.5 ml
Calibrator 3: 0.5 ml
Calibrator 4:0.5 ml
Calibrator 5: 0.5 ml
Control serum: 0.5 ml
Washing solution (concentrated 25-fold): 50 ml
TMB/substrate solution: 12 ml
Stopping reagent 0.2M H2SO4: 25 ml
Protective film: 1
Plastic dish: 2
Plastic zip-lock bag: 1
All-in-One Design
FDA 510(K) & CLIA Waived Up to 99% accuracy rate Results in as little as 1 minute 24 Month Shelf Life from Date of Manufacture Secure, seal and send to lab for confirmation Built in temperature strip Available to test up to 17 substances with adulterants or 18 without adulterants Adulterants available
 
 
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin. Feature
  • Auto zero function: Manual blanking not required
  • Dual wavelength measurement system:
  • 2 wave lengths 455nm and 575nm
  • Plays major role to remove the interference caused due to Hemolysis & turbidity of sample
  • LED Light source:
  • LED does not require replacement as it lasts longer
  • As compared to Lamp, LED are more suitable as there is no intensity fluctuations
  • No warm up time required.
  • Flexible unit selection:
  • Two units either mg/dl or umol/L are selectable, ease of reporting
  • Compact slot for Capillary:
  • Accuracy of results are directly related to proper alignment of Capillary
  • B-111 has the easiest mode to ensure precise values
  • Data transfer:
  • External device can be connected to instrument through RS232 por
  • USB port
Technical Specification
  • Light source - LED
  • Wavelength - 455nm and 575nm
  • Net weight - 1kg
  • Measuring range - 0-30 mg/dl , 510 umol/L
  • Display - 16×2 LCD module with backlight
  • Auto calibration - Yes
  • Sample type - Serum or plasma
  • Sample volume - 40-80μL
  • Test time - <5sec
  • Units - mg/dl or umol/L
  • Dimensions - 150 (W) × 115 (H) × 190 (D) mm
  • Interface - RS232
  • Reading cuvette - Heparinized micro capillary holder
  • Storage temperature - 15-40°c
  • Power supply - DC 9V(DC adapter)
  • Power consumption - <2W
800-1  electric centrifuge is widely used in hospitals, chemical and Biological Chemistry Laboratory for serum, plasma, immune qualitative analysis experiment. Has beautiful shape, large capacity, small volume, complete function. Its performance is stable, the speed is adjustable and can automatically adjust the balance, low temperature, high efficiency and wide applicability and advantages. Technical Specifications:
Type No.
800-1
Power  source
220V 50HZ     110V  60HZ
Speed Range (rpm)
0~4000(rpm)
Time Range(min)
0-60min
Capacity (ml)
20(ml)×6
Maximum centrifugal force(xg)
1790(xg)
Package Size (cm)
29*29*26
 
Click Here To Download Catalogue
Twenty Five (25) Test Strip per PackThe technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Unlike traditional ESR methodologies that measure the aggregation of the red blood cells indirectly, the iSED measures it directly and expresses the values in mm/hr. Features:
  • Results in 20 Seconds

  • 100µL sample drawn directly from primary EDTA tube

  • Fully automated, walk-away operation

  • Random access

  • Positive patient identification via internal barcode reader

  • Compatible with pediatric tube

     
Technical Specifications: 
Principle of Measure: Photometrical
Results: “Printed mm/hr, Range from 1-130 mm/hr”
Sample Requirements: 500uL whole blood, collected in EDTA anti-coagulant tested 24 hours from venipuncture at room temperature or refrigerated.
Tube Requirements: 13 x 75 mm, pierceable capped tube
Quality Control: Barcoded Seditrol® QC
Barcode Reader: Internal
Printer: Internal
Interface Specifications: serial RS232 port for LIS connection
Weight: 14 kg
Dimensions (H x W x D): 36 x 27 x 34 (cm) /14.3 x 10.5 x13.4 (in)
Voltage: 100-240VAC
Frequency Range: 50-60 Hz
Power: 160W
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare