Erma B-111 Bilirubin Meter

750,000.00

Shipped From Aboard 
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.

SF1033560084-6

Description

The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric
analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.

Feature

  • Auto zero function: Manual blanking not required
  • Dual wavelength measurement system:
  • 2 wave lengths 455nm and 575nm
  • Plays major role to remove the interference caused due to Hemolysis & turbidity of sample
  • LED Light source:
  • LED does not require replacement as it lasts longer
  • As compared to Lamp, LED are more suitable as there is no intensity fluctuations
  • No warm up time required.
  • Flexible unit selection:
  • Two units either mg/dl or umol/L are selectable, ease of reporting
  • Compact slot for Capillary:
  • Accuracy of results are directly related to proper alignment of Capillary
  • B-111 has the easiest mode to ensure precise values
  • Data transfer:
  • External device can be connected to instrument through RS232 por
  • USB port

Technical Specification

  • Light source – LED
  • Wavelength – 455nm and 575nm
  • Net weight – 1kg
  • Measuring range – 0-30 mg/dl , 510 umol/L
  • Display – 16×2 LCD module with backlight
  • Auto calibration – Yes
  • Sample type – Serum or plasma
  • Sample volume – 40-80μL
  • Test time – <5sec
  • Units – mg/dl or umol/L
  • Dimensions – 150 (W) × 115 (H) × 190 (D) mm
  • Interface – RS232
  • Reading cuvette – Heparinized micro capillary holder
  • Storage temperature – 15-40°c
  • Power supply – DC 9V(DC adapter)
  • Power consumption – <2W