ACETIC ACID 5% v/v

$0.00

Shipped From Abroad

Available in 100mL Bottles and 500mL Bottles

Composition Acetic Acid 5% v/v in Purified Water.

Use An acidic solution, which decreases the pH of the surrounding environment in laboratory applications

Warnings Not for personal use.

Delivery & Availability:

Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF103356013099-21
Brands:: PharmAust

Description

Product Description

Composition Acetic Acid 5% v/v in Purified Water.

Use An acidic solution, which decreases the pH of the surrounding environment in laboratory applications

Warnings Not for personal use.

Do not irrigate the brain, meninges or perforated eardrum.

The solution is not isotonic.

The solution is haemolytic.

Adverse Effects A transient stinging sensation may occur if spilt on skin.

Directions for Use Use as necessary to acidify surrounding media.

Safety Directions Avoid contact with eyes and skin. Avoid breathing vapour.

First Aid For advice, contact a Poisons Information Centre (phone Australia 131126) or a doctor. If swallowed, do NOT induce vomiting. If in eyes, hold eyelids apart and flush the eye continuously with running water. Continue flushing until advised to stop by the Poisons Information Centre or doctor, or for at least 15 minutes. Storage Store below 25oC

Poison Schedule Not scheduled.

Available in 100mL Bottles and 500mL Bottles

Quick Comparison

SettingsACETIC ACID 5% v/v removeiSED Fully Automated ESR Analyzer removePlastic Urine Container Per Pack removeEppendorf Pipette Tip 200ul Per Pack removeLittle Sister Table Top Autoclave removeDiscover 5 Panel Cup with Adulterants Per Pack remove
NameACETIC ACID 5% v/v removeiSED Fully Automated ESR Analyzer removePlastic Urine Container Per Pack removeEppendorf Pipette Tip 200ul Per Pack removeLittle Sister Table Top Autoclave removeDiscover 5 Panel Cup with Adulterants Per Pack remove
ImageEppendorf Pipette Tip 200ul Per PackDrug Test Cup
SKUSF103356013099-21SF1033560084-129SF1033560084-106SF1033560084-137SF1033560084-46SF1033560084-23
Price

$0.00

$0.00

$8.20

$0.00

$1,350.00

$0.00

Add to cart
DescriptionShipped From Abroad
Available in 100mL Bottles and 500mL Bottles Composition Acetic Acid 5% v/v in Purified Water. Use An acidic solution, which decreases the pH of the surrounding environment in laboratory applications Warnings Not for personal use. Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Total Volume: 60mL.
  • Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
  • Made of premium PP material, it is durable for usage.
  • Some measurements can be used to not only use urine samples, it can also be used for other liquids.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Made of high quality PP material with good transparency.
  • Applied for Gilson/Finland/Eppendorf Pipettors.
  • Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
  • Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
  • Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Out stock Little Sister Table Top Autoclave: This sterilizer is a table type in safety and auto controlled,which is designed for the unit of medical health, pharmacy, science and technology and mostly suitable for sterilizing of surgical,dental and eye instruments, glassware medicine, culture medium and biological dressing, food and other goods. Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self-contained and the entire cup is tamper resistant. Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Product Description
Composition Acetic Acid 5% v/v in Purified Water. Use An acidic solution, which decreases the pH of the surrounding environment in laboratory applications Warnings Not for personal use. Do not irrigate the brain, meninges or perforated eardrum. The solution is not isotonic. The solution is haemolytic. Adverse Effects A transient stinging sensation may occur if spilt on skin. Directions for Use Use as necessary to acidify surrounding media. Safety Directions Avoid contact with eyes and skin. Avoid breathing vapour. First Aid For advice, contact a Poisons Information Centre (phone Australia 131126) or a doctor. If swallowed, do NOT induce vomiting. If in eyes, hold eyelids apart and flush the eye continuously with running water. Continue flushing until advised to stop by the Poisons Information Centre or doctor, or for at least 15 minutes. Storage Store below 25oC Poison Schedule Not scheduled. Available in 100mL Bottles and 500mL Bottles
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Unlike traditional ESR methodologies that measure the aggregation of the red blood cells indirectly, the iSED measures it directly and expresses the values in mm/hr. Features:
  • Results in 20 Seconds

  • 100µL sample drawn directly from primary EDTA tube

  • Fully automated, walk-away operation

  • Random access

  • Positive patient identification via internal barcode reader

  • Compatible with pediatric tube

     
Technical Specifications: 
Principle of Measure: Photometrical
Results: “Printed mm/hr, Range from 1-130 mm/hr”
Sample Requirements: 500uL whole blood, collected in EDTA anti-coagulant tested 24 hours from venipuncture at room temperature or refrigerated.
Tube Requirements: 13 x 75 mm, pierceable capped tube
Quality Control: Barcoded Seditrol® QC
Barcode Reader: Internal
Printer: Internal
Interface Specifications: serial RS232 port for LIS connection
Weight: 14 kg
Dimensions (H x W x D): 36 x 27 x 34 (cm) /14.3 x 10.5 x13.4 (in)
Voltage: 100-240VAC
Frequency Range: 50-60 Hz
Power: 160W
Click Here To Download Catalogue
  • Total Volume: 60mL.
  • Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
  • Made of premium PP material, it is durable for usage.
  • Some measurements can be used to not only use urine samples, it can also be used for other liquids.
  • Made of high quality PP material with good transparency.
  • Applied for Gilson/Finland/Eppendorf Pipettors.
  • Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
  • Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
  • Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
  Classification: PIPETTE Brand Name: Vchanslab,Yingmed,OEM Model Number: YM-K7028 Place of Origin: China Product name: Pipette Tips Material: Polypropylene Certificate: CE/ISO13485/FDA Color: Natural, Blue, Yellow Application: Laboratory, Teaching, Hospital
Little Sister Table Top Autoclave: This sterilizer is a table type in safety and auto controlled,which is designed for the unit of medical health, pharmacy, science and technology and mostly suitable for sterilizing of surgical,dental and eye instruments, glassware medicine, culture medium and biological dressing, food and other goods. Features:
  • Indicator light indicates working state.
  • For 4~6 minutes rapidly sterilizing.
  • Sterilizing temperature and time can be preset.
  • Steam-water inner circulation system: no steam discharge, and the environment for sterilizing will be clean and dry.
  • Over temperature & over pressure auto-protection.
  • Safe protection of water lacking.
  • Exhaust the cool air automatically.
  • With three stainless steel sterilizing plates.
  • The chamber of the sterilizer is made of stainless steel.
  • Automatically shut off with beep reminding after sterilization.
Technical Specifications:
   MODEL   MC-XB20J MC-XB24J

Sterilizing chamber volume

20L(φ250×420 mm) 24L(φ250×520 mm)
Maximum working pressure 0.22Mpa
Maximum working temperature 134℃
Adjustment of temperature 105-134℃
Timer 0-60 min
Chamber temperature equal ≤ ± 1℃
Source power 1.5KW/AC 220V 50Hz (AC110V 60HZ)
Sterilizing plate 340×200×30 mm (3 piece) 400×200×30 mm (3 piece)
Dimension 480×480×384 mm 580×480×384 mm
Package dimension 700×580×500 mm 800×580×500 mm
 G. W/N.W 44/40 kg

50/45 kg

   
 
 
All-in-One Design
FDA 510K & CLIA Waived 99% Accurate Results in as little as 1 minute 24 Month Shelf Life from Date of Manufacture Secure, seal and send to lab for confirmation Built in temperature strip Available to test up to 14 substances Adulterants available
 
 
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
en English
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare