| In stock
Theory: |
Psa |
Certification: |
CE, ISO13485 |
LCD Display: |
With LCD Display |
Group: |
Adult |
Oxygen Flow Rate: |
0.5~8L/Min |
Oxygen Density: |
>90% |
Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In Stock
FVC, VC, MVV, PRE/POST Bronchodilator comparison with a wide range of selectable parameters.
Pediatric Incentive for Spirometry. Each function can be easily activated by a simple touch on the bar menu Stand Alone Mode
Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In Stock
Max loading:180KG(400lb) in movement
Backrest tilting From 0°to 75°±5°
Footrest tilting From 0°to 40°±5°
Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from Abroad
Bistos BT - 740 Patient Monitor: Bistos Patient Vital Signs Monitor, ECG, Resp., SpO2, NIBP, Temp., BT-740. The Bistos BT-740 is a multi-parameter patient monitor with an 8.4" TFT Color screen. The standard paramaters are ECG, respiratory, SpO2, NIBP and temperature. Additional options are EtCO2, IBP, Multi-gas, CO and Masimo SpO2. The BT-740 has a fanless design for quiet operation.
Delivery & Availability:
Typically 7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from Abroad
TouchTymp MI 36 combines diagnostic middle ear analyzer and audiometry tests in one exceptional device. The full 10.4" touchscreen with its user-friendly interface guarantees a unique intuitive operation and allows to quickly change parameters. You can easily switch between the tests without reorganizing from one to another device and beneft from its small footprint when facing limited desk space. touchTymp MI 36 really improves your workflow every day.
Delivery & Availability:
Typically 10 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. |
Content |
Available in: 50mL 100mL 500mL bottle and 2L Can
Uses:
- Versatile cleaning solvent to remove resins
- Can be used as a paint thinner or nail polish remover
Warning: Flammable Liquid. 
Avoid contact with eyes and skin. Avoid breathing vapour. If poisoning occurs, contact a doctor or Poisons information Centre (Tel: 13 11 26). If swallowed, do not induce vomiting. Give a glass of water. Keep out of reach of children
Store below 30°C
|
* French imported molecule sieve, long life and more efficiency.
* Adopts american PSA technology, use Physical method to separate pure oxygen from air.
* Brand-new design, Small size and nice looking
* Compact structure design, light weight, easy to move
* Advanced oil-free compressor, save 30% power energy
* Big LCD Screen easy to operate
* Displaying the oxygen concentration in real time.
* Optional nebuylizer and oxygen purity alarm function
* Power off alarm, abnormal voltage alarm
|
FVC, VC, MVV, PRE/POST Bronchodilator comparison with a wide range of selectable parameters.
Paediatric Incentive for Spirometry. Each function can be easily activated by a simple touch on the bar menu Stand Alone Mode.
Colour screen
Touchscreen 7 inches TFT display
Database up to 10,000 Spirometry tests
or 900 hours of Oximetry recording coupled with powerful and flexible search services.
Optional function available:
Oximeter with adult or paediatric finger probe.
Long life Rechargeable Battery.
Available with both DISPOSABLE or REUSABLE turbine flowmeter.
PC based mode, using WinspiroPRO®
Bluetooth® 2.1 and USB Connectivity
Wireless or via cable Real Time test directly on your PC.
Winspiro PRO® PC software
provides Real Time Flow/Volume and Volume/Time curves with PRE/POST Bronchodilator comparison on your PC. Includes free online updates.
Paediatric Incentive for Spirometry with wide choice of pictures and animations.
Spirometry test after drug adminitration
Bronchodilator Reversibility, Bronchial Challenge with FEV1-response curve with protocols for both Methacholine and Mannitol.
Quanjer 2012-GLI Predicted values with LLN and Z-score
Patient Trend Charts for easy follow-up Search engine for instant access to database. Wide choice of communication protocols for integration with EMR.
Spirometry parameters:
FVC, FEV1, FEV1/FVC, FEV1/VC, PEF, FEF25, FEF50, FEF75, FEF25–75, FEF75–85, Lung Age, Extrapolated Volume, FET, Time to PEF, FEV0.5, FEV0.5/FVC, FEV0.75, FEV0.75/FVC, FEV2, FEV2/FVC, FEV3, FEV3/FVC, FEV6, FEV1/ FEV6, FEV1/PEF, FEV1/ FEV0.5, FIVC, FIV1, FIV1/FIVC, PIF, FIF25, FIF50, FIF75, FEF50/FIF50, VC, IVC, IC, ERV, IRV, Rf, VE, VT, tI, tE, VT/tI, tE/tTOT, MVV (measured), MVV (calculated).
| Product Size:2125*970*540mm
Packing size: 205*96*26cm/2pcs
Max loading:180KG(400lb) in movement
Backrest tilting From 0°to 75°±5°
Footrest tilting From 0°to 40°±5°
Standard Accessories:
4pcs 5” standard castor two with brake,
1 pair aluminum side rail,
2pcs ABS head and foot board,
4pcs urine hooks,
2pcs cranks system | Bistos BT - 740 Patient Monitor: Bistos Patient Vital Signs Monitor, ECG, Resp., SpO2, NIBP, Temp., BT-740. The Bistos BT-740 is a multi-parameter patient monitor with an 8.4" TFT Color screen. The standard paramaters are ECG, respiratory, SpO2, NIBP and temperature. Additional options are EtCO2, IBP, Multi-gas, CO and Masimo SpO2. The BT-740 has a fanless design for quiet operation.
Features:
- 8.4" TFT Color Screen - (Optional Touch Screen Upgrade)
- Standard parameters are ECG, Resp., SpO2, NIBP, Temp.
- Ultra-low power consumption
- Quiet operation
- High accuracy SpO2 reading
- Data transfer or firmware upgrade via USB
- 2 Years Manufacturer's Warranty
Technical Specifications:
Model |
BT-740 |
Display |
8.4" Color TFT Screen |
ECG |
Lead type |
3/5 Lead |
Gain Selection |
x0.25, x0.5, x1, x2, x4, auto |
Sweep speed (mm/s) |
12.5, 25, 50 |
Bandwith:(Diagnostic Mode) |
0.05-130Hz |
Monitoring Mode |
0.5-40Hz |
Surgery Mode |
1-25Hz |
Strong Mode |
5-20Hz |
Heart Rate Range (bpm) |
Adult:15-300 |
Pediatric/neonate: 15-350 |
Respiration |
Method |
Trance-thoracic Impedance |
Measurement Range |
0-120rpm |
Sweep Speed (mm/s) |
6.25, 12.5, 25 |
SpO2 |
Measurement Range |
0-100% |
Accuracy (70-100%) |
Adult/Pediatric |
+/-2% |
Neonate |
+/-3% |
Accuracy (0-69%) |
Unspecified |
Perfusion Index |
0.05-20% |
Pulse Rate |
Range (bpm) |
25-250bpm |
NIBP** |
Method |
Automatic (Oscillometric) |
Operation Mode |
Manual/Auto/STAT |
Parameter |
Systolic, Diastolic, Mean |
Systolic Range (mmHg) |
Adult |
40-270 |
Pediatric |
40-200 |
Neonate |
40-130 |
Diastolic Range (mmHg) |
Adult |
10-210 |
Pediatric |
10-160 |
Neonate |
10-90 |
Mean Range (mmHg) |
Adult |
20-230 |
Pediatric |
20-175 |
Neonate |
20-100 |
Temperature |
Range |
0-50°C |
Parameter |
T1, T2 and TD |
IBP" |
Channel |
2 Channel, 4 Channel |
Range (mmHg) |
-50-400 |
Printer* |
Type |
Thermal dot array |
Print Speed (mm/s) |
12.5, 25, 50 |
Paper Size (mm) |
50 |
CO2* |
Sidestream |
Masimo ISA / Bistos |
Mainstream |
Masimo IRMA / Bistos |
Multi-gas O2* |
Masimo ISA |
SpO2 Masimo* |
Masimo SpO2 |
CO* |
Method |
Thermodilution |
Range |
0.2-20 L/min |
Battery |
Type (Capacity) |
Li-ion (440mAh) |
Run Time |
6 hour |
Charging Time |
4 hour |
Interface |
RJ45, USB, Nursing Call |
Warranty |
2 Years |
| TouchTymp MI 36 combines diagnostic middle ear analyzer and audiometry tests in one exceptional device. The full 10.4" touchscreen with its user-friendly interface guarantees a unique intuitive operation and allows to quickly change parameters. You can easily switch between the tests without reorganizing from one to another device and beneft from its small footprint when facing limited desk space. touchTymp MI 36 really improves your workflow every day.
FEATURES AT A GLANCE
- Combo device with small footprint
- Customizable to suit individual needs
- High resolution and quick screen transitions
- Full touch-based interface for intuitive handling
- Probe tone 226 Hz, 678 Hz, 800 Hz
- Optional high-frequency probe tone 1 kHz
- Acoustic reflex stimuli 500 Hz,1 kHz, 2 kHz, 4 kHz, BB, HP, LP (ipsilateral and contralateral)
- Reflex Decay test (ipsilateral and contralateral)
- ETF test for intact and perforated eardrums
- Air conduction audiometry
- Bone conduction audiometry
- Built-in printer or data transfer to PC
- Optional MAICO Sessions PC Software connectable with OtoAccess® or Noah patient database for easy data management
Comprehensive test protocols
- Our touchTymp MI 36 provides comprehensive standard protocols for immediate operation of screening and diagnostic test processes: tympanometry with 226 Hz, tympanometry with automatic or fxed acoustic reflexes, reflex decay, Eustachian tube function testing (ETF) plus air conduction and bone conduction audiometry. The optional high-frequency probe tone of 1 kHz is ideal for providing reliable results when testing newborns
Stay focused on your patients
- The unique touchTymp light bar on our shoulder box probe provides a real-time progression of the immittance test. The shoulder box can easily be clipped to your patient's top for controlled handling of the diagnostic probe. The light indicator shows you which ear is tested and the test result.
Printing made easy
- Print test results instantly by using the touchTymp built-in printer. Place the shoulder box into its holder to automatically start printing. You can transfer the results to a PC to allow long term storage, full page printout and PDF creation for EMR integration.
Compatible to Sessions: Get ready for fast data transfer!
- Use the touchTymp MI 36 with our intuitive data transfer solution Sessions, for easy management and visualization of your immittance measurements.
TECHNICAL SPECIFICATION
Tympanometry
- Probe Frequency - 226 Hz ± 1 %, 85 dBSPL ± 1.5 dB, 678 Hz ± 1%, 72 dBSPL ± 1.5 dB, 800 Hz ± 1%, 70.5 dBSPL ± 1.5 dB
- Optional High Frequency - 1 kHz ± 1%, 69 dBSPL ± 1.5 dB
- Pressure Range - -600 to + 400 daPa
- Accuracy of Pressure - ± 5 % or ± 10 daPa
- Volume Range - 0.0 to 6.0 ml (compensated)
- Compliance Range - 0.1 to 8.0 ml at 226 Hz, 0.1 to 15.0 mmho at 678, 800 and 1000 Hz
- Accuracy of Volume - ± 5 % or 0.1 ml
- Test Time Measurement - 3 - 5 seconds
Acoustic Reflexes
- Test Frequencies - 0.5, 1, 2, 4 kHz ± 1 %
- Test Noise - BB, LP, HP
- Test Methods - Ipsilateral, contralateral
- Level Ipsilateral - 70 to 105 dBHL
- Level Contralateral - 70 to 120 dBHL
- Level Setting - Automatic, fxed
- Ipsilateral Reflex - Test With AGC
Reflex Decay
- Standard - Probe frequency 226 Hz
- Test Frequencies - 0.5, 1, 2, 4 kHz ± 1 %
- Test Noise - BB, LP, HP
- Level Ipsilateral - 70 to 105 dBHL
- Level Contralateral - 70 to 120 dBHL
Eustachian Tube Function
- Test Methods - Intact and perforated
- Pressure Range - -600 to + 400 daPa
Audiometry
- Test Signals - Sinus and warble tone, (pulsed and continuous)
- Test Frequencies - 125, 250, 500, 750, 1000, 1500, 2000, 3000, 4000, 6000, 8000 Hz (125 Hz excluded
- from bone conduction test frequencies)
- Level Steps - 5 or 1 dB
- Hearing Level Range AC - -10 to 120 dBHL
- Hearing Level Range BC - -10 to 80 dBHL
- Masking Noise - Narrow band and white noise
Device General
- Display - 10.4" Graphic LED-Display with resistive touchscreen
- PC Interface - USB
- Probe - Lightweight diagnostic Shoulder-Box with built-in control light and switch
- Printer - Fast 4 inch thermal printer
- Power Supply - Mains 100 to 240 V~ ± 10 %, 50 - 60 Hz ± 10 %
- Dimensions / Weight - W 30 x D 34.5 x H 14.8 cm / 3.2 kg
- Languages - English, German, Spanish, French, Polish, Turkish, Russian, Chinese
|