Atomic Absorption Spectrophotometer

Ask for Price$0.00

Shipped From Abroad

The atomic absorption spectrophotometer is widely used in the analysis of major and trace elements in metallurgy, geology, mining, petroleum, light industry, agriculture, medicine, health, food and environmental monitoring.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130127-34
Brands:: Scitek

Description

Atomic Absorption Spectrophotometer Features:
  1. Equipped with a complete software and hardware system, it is highly intelligent, easy to use and simple to operate, and meets the requirements of authority management, audit tracking and other requirements.
  2. It has both flame and graphite furnace atomizers. The two test modes can be switched freely and matched automatically.
  3. Fully automatic eight-lamp position rotating lamp stand, automatic switching, free setting of work lamp/preheating lamp, automatic call of optimal analysis parameters and analysis conditions.
  4. Total reflection optical system, full-band achromatic, automatic wavelength scanning, automatic peak search.
  5. Both the flame and graphite furnace systems have deuterium lamps and self-priming background subtraction to meet the detection needs of complex matrix samples.
  6. Full titanium burner, stable combustion and fast heat balance.
  7. Longitudinal heating graphite furnace technology achieves uniform temperature of the graphite tube.
  8. Reliable multiple protection systems, real-time flame monitoring, acetylene leakage monitoring and protection, real-time monitoring of abnormal pressure, and cooling water monitoring.
  9. The graphite furnace atomization system has alarm functions for insufficient cooling water flow, insufficient argon pressure, excessive temperature of the graphite furnace, abnormal power supply temperature, and poor contact during graphite tube installation, and automatically cuts off the temperature rise program to ensure the safety of the operation and use process.
Advantages

1.Equipped with a complete software and hardware system, it is highly intelligent, easy to use and simple to operate, and meets the requirements of authority management, audit tracking and other requirements.

2.It has both flame and graphite furnace atomizers. The two test modes can be switched freely and matchedautomatically.

3.Fully automatic eight-lamp position rotating lamp stand, automatic switching, free setting of work lamp/preheating lamp, automatic call of optimal analysis parameters and analysis conditions.

Applications

The Atomic Absorption Spectrophotometer is widely used in the analysis of major and trace elements in metallurgy, geology, mining, petroleum, light industry, agriculture, medicine, health, food and environmental monitoring.

 

Atomic Absorption Spectrophotometer Specifications:
Model SP-AA3638 SP-AA3668
Optical System Optical System Single Beam Double Beam
Monochromator Czerny-Turner type, focal lengths at 350mm
Grating Grating 1800 lines/mm, scintillation wavelength 250nm
Spectral Bandwidth (nm) 0.1, 0.2, 0.4, 0.7, 1.4, 2nm
Automated slit selection
Wavelength Range (nm) 185-900nm
Wavelength Accuracy (nm) 0.20 nm 0.15nm
Wavelength Repeatability (nm) ≤0.10nm ≤0.05nm
Spectral Bandwidth Deviation ±0.02 nm
Lamp Stand 8
Element Lamp Type Cu lamp, Cd lamp(Standard accessory)
Other element lamp is optional accessory
Photometric Performance Reading Mode Transmittance, absorbance, concentration
Photometric Range 0-125%, -0.1-3.00A
Static Baseline Drift (Cu) ±0.003A/30min ±0.003A/30min
Dynamic Baseline Drift (Cu) ±0.005A/15min ±0.005A/15min
Background Correction Deuterium lamp≥ 40x (1Abs), self-priming≥ 80x (1Abs) (optional) Deuterium lamp≥ 40x (1Abs), self-priming≥ 80x (1Abs) (optional)
Flame System Characteristic Concentration (Cu) ≤0.035ug/ml ≤0.035ug/ml
Detection Limit (Cu) ≤0.006ug/ml ≤0.004ug/ml
Repeatability (Cu) RSD≤0.6% RSD≤0.5%
Acetylene Flow Control Auto 12-Level
Air Assist Control Auto 4-Level
Burner Lift Automatic lifting
Burner Head Titanium 100mm burner
Nebulizer High efficiency glass nebulizer
Spray Chamber Corrosion-resistant material spray chamber
Safety Protection Automatically cut off gas in case of low pressure, power failure, flame out, or burner mismatched
Graphite Furnace Characteristic Amount Cd≤0.8pg,Cu≤20pg Cd≤0.8pg,Cu≤20pg
Detection Limit Cd≤1.0pg,Cu≤10pg Cd≤0.8pg,Cu≤5pg
Repeatability(Cd) RSD≤3% RSD≤2.5%
Heating Range of Graphite Furnace Room temperature-3000℃
High Power Heating Range 1500-3000℃
Slope and Holding Time 1s-255s
Heating Rate Maximum heating rate 2000°C/s
Atomization Heating Mode Light-controlled heating, Time-controlled heating, General heating
Protective Gas Flow Outside Pipe 1 L/min
Protective Gas Flow Inside Pipe 4-speed adjustable (0, 50, 200, 250ml/min flow)
Safety Protection Cooling water flow, Protective gas pressure, Furnace body temperature, Power supply temperature, Graphite furnace installation alarm
Data Processing Measuring Method Measuring method
Concentration Calculation Method Concentration calculation method
Repeat Measurement Times Repeat measurement times
Report Printing Report printing
Other Computer External connect
Ambient Temp 10℃-30℃
Ambient Humidity 40%-85%
Power Supply 220V, 50/60HZ
External Size (WxDxH)(mm) 830x650x560
Shipping Size (WxDxH)(mm) 1000x780x810
N.W./G.W. (kg) 110/130
Standard Accessory Software, Cd Hollow cathode lamp, Pipette
Optional Accessory Computer, Printer, Autosampler, Recirculating cooling water system

Reviews

There are no reviews yet.

Be the first to review “Atomic Absorption Spectrophotometer”

Your email address will not be published. Required fields are marked *

Quick Comparison

Atomic Absorption Spectrophotometer removeApexBio HemoSmart Gold Hemoglobin Meter removeErma B-111 Bilirubin Meter remove8 Bucket Centrifuge removeAutomatic Pipette removeMotic BA210 Series Biomedical Microscope remove
NameAtomic Absorption Spectrophotometer removeApexBio HemoSmart Gold Hemoglobin Meter removeErma B-111 Bilirubin Meter remove8 Bucket Centrifuge removeAutomatic Pipette removeMotic BA210 Series Biomedical Microscope remove
Image
SKUSF1033560130127-34SF1033560084-29SF1033560084-6SF1033560084-114SF1033560084-130SF1033560084-78
Rating
Price

Ask for Price$0.00

$55.00

Ask for Price$0.00

$72.50

Ask for Price$0.00

Ask for Price$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad The atomic absorption spectrophotometer is widely used in the analysis of major and trace elements in metallurgy, geology, mining, petroleum, light industry, agriculture, medicine, health, food and environmental monitoring.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock HemoSmart GOLD offers a fast and easy way to measure hemoglobin level and is the first biosensor-based palm sized hemoglobin testing system in the world.The one of its kind strip-based testing method offers ease of use and portability and requires only 1μL of blood.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Aboard  The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
Classification: Laboratory Centrifuge
Brand Name: xiangtian
Model Number: 800-1
Place of Origin: Jiangsu, China
Time range: 0-60min
Max speed: 4000r/min
Max RCF: 1790xg
Capacity: 20ml*6
  Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
This Automatic Pipette will help you get your lab up and running in no time—at a great price! Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock The BA210 series is a line of basic biological microscopes manufactured by Motic. The unit is equipped with Motic Infinity Optics (CCIS®, offering quality performance in the fields of education and training. The device features a coaxial coarse and fine housing with a quadruple reverse-mounted nose piece. Its contrast methods, such as phase contrast, polarization and dark field, are easily performed through optional accessories. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Atomic Absorption Spectrophotometer Features:
  1. Equipped with a complete software and hardware system, it is highly intelligent, easy to use and simple to operate, and meets the requirements of authority management, audit tracking and other requirements.
  2. It has both flame and graphite furnace atomizers. The two test modes can be switched freely and matched automatically.
  3. Fully automatic eight-lamp position rotating lamp stand, automatic switching, free setting of work lamp/preheating lamp, automatic call of optimal analysis parameters and analysis conditions.
  4. Total reflection optical system, full-band achromatic, automatic wavelength scanning, automatic peak search.
  5. Both the flame and graphite furnace systems have deuterium lamps and self-priming background subtraction to meet the detection needs of complex matrix samples.
  6. Full titanium burner, stable combustion and fast heat balance.
  7. Longitudinal heating graphite furnace technology achieves uniform temperature of the graphite tube.
  8. Reliable multiple protection systems, real-time flame monitoring, acetylene leakage monitoring and protection, real-time monitoring of abnormal pressure, and cooling water monitoring.
  9. The graphite furnace atomization system has alarm functions for insufficient cooling water flow, insufficient argon pressure, excessive temperature of the graphite furnace, abnormal power supply temperature, and poor contact during graphite tube installation, and automatically cuts off the temperature rise program to ensure the safety of the operation and use process.
Advantages
1.Equipped with a complete software and hardware system, it is highly intelligent, easy to use and simple to operate, and meets the requirements of authority management, audit tracking and other requirements. 2.It has both flame and graphite furnace atomizers. The two test modes can be switched freely and matchedautomatically. 3.Fully automatic eight-lamp position rotating lamp stand, automatic switching, free setting of work lamp/preheating lamp, automatic call of optimal analysis parameters and analysis conditions.
Applications
The Atomic Absorption Spectrophotometer is widely used in the analysis of major and trace elements in metallurgy, geology, mining, petroleum, light industry, agriculture, medicine, health, food and environmental monitoring.  
Atomic Absorption Spectrophotometer Specifications:
Model SP-AA3638 SP-AA3668
Optical System Optical System Single Beam Double Beam
Monochromator Czerny-Turner type, focal lengths at 350mm
Grating Grating 1800 lines/mm, scintillation wavelength 250nm
Spectral Bandwidth (nm) 0.1, 0.2, 0.4, 0.7, 1.4, 2nm
Automated slit selection
Wavelength Range (nm) 185-900nm
Wavelength Accuracy (nm) 0.20 nm 0.15nm
Wavelength Repeatability (nm) ≤0.10nm ≤0.05nm
Spectral Bandwidth Deviation ±0.02 nm
Lamp Stand 8
Element Lamp Type Cu lamp, Cd lamp(Standard accessory)
Other element lamp is optional accessory
Photometric Performance Reading Mode Transmittance, absorbance, concentration
Photometric Range 0-125%, -0.1-3.00A
Static Baseline Drift (Cu) ±0.003A/30min ±0.003A/30min
Dynamic Baseline Drift (Cu) ±0.005A/15min ±0.005A/15min
Background Correction Deuterium lamp≥ 40x (1Abs), self-priming≥ 80x (1Abs) (optional) Deuterium lamp≥ 40x (1Abs), self-priming≥ 80x (1Abs) (optional)
Flame System Characteristic Concentration (Cu) ≤0.035ug/ml ≤0.035ug/ml
Detection Limit (Cu) ≤0.006ug/ml ≤0.004ug/ml
Repeatability (Cu) RSD≤0.6% RSD≤0.5%
Acetylene Flow Control Auto 12-Level
Air Assist Control Auto 4-Level
Burner Lift Automatic lifting
Burner Head Titanium 100mm burner
Nebulizer High efficiency glass nebulizer
Spray Chamber Corrosion-resistant material spray chamber
Safety Protection Automatically cut off gas in case of low pressure, power failure, flame out, or burner mismatched
Graphite Furnace Characteristic Amount Cd≤0.8pg,Cu≤20pg Cd≤0.8pg,Cu≤20pg
Detection Limit Cd≤1.0pg,Cu≤10pg Cd≤0.8pg,Cu≤5pg
Repeatability(Cd) RSD≤3% RSD≤2.5%
Heating Range of Graphite Furnace Room temperature-3000℃
High Power Heating Range 1500-3000℃
Slope and Holding Time 1s-255s
Heating Rate Maximum heating rate 2000°C/s
Atomization Heating Mode Light-controlled heating, Time-controlled heating, General heating
Protective Gas Flow Outside Pipe 1 L/min
Protective Gas Flow Inside Pipe 4-speed adjustable (0, 50, 200, 250ml/min flow)
Safety Protection Cooling water flow, Protective gas pressure, Furnace body temperature, Power supply temperature, Graphite furnace installation alarm
Data Processing Measuring Method Measuring method
Concentration Calculation Method Concentration calculation method
Repeat Measurement Times Repeat measurement times
Report Printing Report printing
Other Computer External connect
Ambient Temp 10℃-30℃
Ambient Humidity 40%-85%
Power Supply 220V, 50/60HZ
External Size (WxDxH)(mm) 830x650x560
Shipping Size (WxDxH)(mm) 1000x780x810
N.W./G.W. (kg) 110/130
Standard Accessory Software, Cd Hollow cathode lamp, Pipette
Optional Accessory Computer, Printer, Autosampler, Recirculating cooling water system
HemoSmart GOLD offers a fast and easy way to measure hemoglobin level and is the first biosensor-based palm sized hemoglobin testing system in the world.The one of its kind strip-based testing method offers ease of use and portability and requires only 1μL of blood. Feature
  • LCD Backlight
  • Small Blood Sample
  • Splash Proof
  • Strip Ejection
  • Hgb/Hct
  • Fast Result
Specification
  • Measurement Range: 0-24.0 g/dL
  • Power Supply: 3A battery X 2
  • Testing Time (seconds): 5 seconds
  • Sample Volume (μL): 1 μL
  • Memory Capabilities: 100 sets with date and time
  • Operating Temperature (°C): 10 °C~40 °C
 
Click Here To Download Catalogue
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin. Feature
  • Auto zero function: Manual blanking not required
  • Dual wavelength measurement system:
  • 2 wave lengths 455nm and 575nm
  • Plays major role to remove the interference caused due to Hemolysis & turbidity of sample
  • LED Light source:
  • LED does not require replacement as it lasts longer
  • As compared to Lamp, LED are more suitable as there is no intensity fluctuations
  • No warm up time required.
  • Flexible unit selection:
  • Two units either mg/dl or umol/L are selectable, ease of reporting
  • Compact slot for Capillary:
  • Accuracy of results are directly related to proper alignment of Capillary
  • B-111 has the easiest mode to ensure precise values
  • Data transfer:
  • External device can be connected to instrument through RS232 por
  • USB port
Technical Specification
  • Light source - LED
  • Wavelength - 455nm and 575nm
  • Net weight - 1kg
  • Measuring range - 0-30 mg/dl , 510 umol/L
  • Display - 16×2 LCD module with backlight
  • Auto calibration - Yes
  • Sample type - Serum or plasma
  • Sample volume - 40-80μL
  • Test time - <5sec
  • Units - mg/dl or umol/L
  • Dimensions - 150 (W) × 115 (H) × 190 (D) mm
  • Interface - RS232
  • Reading cuvette - Heparinized micro capillary holder
  • Storage temperature - 15-40°c
  • Power supply - DC 9V(DC adapter)
  • Power consumption - <2W
800-1  electric centrifuge is widely used in hospitals, chemical and Biological Chemistry Laboratory for serum, plasma, immune qualitative analysis experiment. Has beautiful shape, large capacity, small volume, complete function. Its performance is stable, the speed is adjustable and can automatically adjust the balance, low temperature, high efficiency and wide applicability and advantages. Technical Specifications:
Type No.
800-1
Power  source
220V 50HZ     110V  60HZ
Speed Range (rpm)
0~4000(rpm)
Time Range(min)
0-60min
Capacity (ml)
20(ml)×6
Maximum centrifugal force(xg)
1790(xg)
Package Size (cm)
29*29*26
 
Click Here To Download Catalogue
This Automatic Pipette will help you get your lab up and running in no time—at a great price! Features:
  • Lowest operation and tip ejection forces
  • Fully autoclavable
  • Ultra light weight with space-age materials
  • Secondary adjustment option for various liquid classes
  • Spring loaded tip con
  • For transferring molecular samples and PCR mix solutions.
  • One set is for DNA work and the other for RNA work. Each with the following specs
  • Light weight, traditional tip shaft, and will fit all generic brands of tips
  • Equal to or better than accuracy and precision compared to ISO 8655, so results can be trusted.
  • Easy and quick volume adjustment with or without gloves. Foolproof volume lock prevents accidental volume changes.
  • Low maintenance and autoclavable 121° for at least 20 minutes
  • Quick release
The BA210 series is a line of basic biological microscopes manufactured by Motic. The unit is equipped with Motic Infinity Optics (CCIS®, offering quality performance in the fields of education and training. The device features a coaxial coarse and fine housing with a quadruple reverse-mounted nose piece. Its contrast methods, such as phase contrast, polarization and dark field, are easily performed through optional accessories. Technical applications: Biomedical Type: Optical Observation technique: Dark field Magnification: 4 unit, 10 unit, 40 unit, 100 unit  
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare