Description

Atomic Absorption Spectrophotometer Features:
  1. Equipped with a complete software and hardware system, it is highly intelligent, easy to use and simple to operate, and meets the requirements of authority management, audit tracking and other requirements.
  2. It has both flame and graphite furnace atomizers. The two test modes can be switched freely and matched automatically.
  3. Fully automatic eight-lamp position rotating lamp stand, automatic switching, free setting of work lamp/preheating lamp, automatic call of optimal analysis parameters and analysis conditions.
  4. Total reflection optical system, full-band achromatic, automatic wavelength scanning, automatic peak search.
  5. Both the flame and graphite furnace systems have deuterium lamps and self-priming background subtraction to meet the detection needs of complex matrix samples.
  6. Full titanium burner, stable combustion and fast heat balance.
  7. Longitudinal heating graphite furnace technology achieves uniform temperature of the graphite tube.
  8. Reliable multiple protection systems, real-time flame monitoring, acetylene leakage monitoring and protection, real-time monitoring of abnormal pressure, and cooling water monitoring.
  9. The graphite furnace atomization system has alarm functions for insufficient cooling water flow, insufficient argon pressure, excessive temperature of the graphite furnace, abnormal power supply temperature, and poor contact during graphite tube installation, and automatically cuts off the temperature rise program to ensure the safety of the operation and use process.
Advantages

1.Equipped with a complete software and hardware system, it is highly intelligent, easy to use and simple to operate, and meets the requirements of authority management, audit tracking and other requirements.

2.It has both flame and graphite furnace atomizers. The two test modes can be switched freely and matchedautomatically.

3.Fully automatic eight-lamp position rotating lamp stand, automatic switching, free setting of work lamp/preheating lamp, automatic call of optimal analysis parameters and analysis conditions.

Applications

The Atomic Absorption Spectrophotometer is widely used in the analysis of major and trace elements in metallurgy, geology, mining, petroleum, light industry, agriculture, medicine, health, food and environmental monitoring.

 

Atomic Absorption Spectrophotometer Specifications:
Model SP-AA3638 SP-AA3668
Optical System Optical System Single Beam Double Beam
Monochromator Czerny-Turner type, focal lengths at 350mm
Grating Grating 1800 lines/mm, scintillation wavelength 250nm
Spectral Bandwidth (nm) 0.1, 0.2, 0.4, 0.7, 1.4, 2nm
Automated slit selection
Wavelength Range (nm) 185-900nm
Wavelength Accuracy (nm) 0.20 nm 0.15nm
Wavelength Repeatability (nm) ≤0.10nm ≤0.05nm
Spectral Bandwidth Deviation ±0.02 nm
Lamp Stand 8
Element Lamp Type Cu lamp, Cd lamp(Standard accessory)
Other element lamp is optional accessory
Photometric Performance Reading Mode Transmittance, absorbance, concentration
Photometric Range 0-125%, -0.1-3.00A
Static Baseline Drift (Cu) ±0.003A/30min ±0.003A/30min
Dynamic Baseline Drift (Cu) ±0.005A/15min ±0.005A/15min
Background Correction Deuterium lamp≥ 40x (1Abs), self-priming≥ 80x (1Abs) (optional) Deuterium lamp≥ 40x (1Abs), self-priming≥ 80x (1Abs) (optional)
Flame System Characteristic Concentration (Cu) ≤0.035ug/ml ≤0.035ug/ml
Detection Limit (Cu) ≤0.006ug/ml ≤0.004ug/ml
Repeatability (Cu) RSD≤0.6% RSD≤0.5%
Acetylene Flow Control Auto 12-Level
Air Assist Control Auto 4-Level
Burner Lift Automatic lifting
Burner Head Titanium 100mm burner
Nebulizer High efficiency glass nebulizer
Spray Chamber Corrosion-resistant material spray chamber
Safety Protection Automatically cut off gas in case of low pressure, power failure, flame out, or burner mismatched
Graphite Furnace Characteristic Amount Cd≤0.8pg,Cu≤20pg Cd≤0.8pg,Cu≤20pg
Detection Limit Cd≤1.0pg,Cu≤10pg Cd≤0.8pg,Cu≤5pg
Repeatability(Cd) RSD≤3% RSD≤2.5%
Heating Range of Graphite Furnace Room temperature-3000℃
High Power Heating Range 1500-3000℃
Slope and Holding Time 1s-255s
Heating Rate Maximum heating rate 2000°C/s
Atomization Heating Mode Light-controlled heating, Time-controlled heating, General heating
Protective Gas Flow Outside Pipe 1 L/min
Protective Gas Flow Inside Pipe 4-speed adjustable (0, 50, 200, 250ml/min flow)
Safety Protection Cooling water flow, Protective gas pressure, Furnace body temperature, Power supply temperature, Graphite furnace installation alarm
Data Processing Measuring Method Measuring method
Concentration Calculation Method Concentration calculation method
Repeat Measurement Times Repeat measurement times
Report Printing Report printing
Other Computer External connect
Ambient Temp 10℃-30℃
Ambient Humidity 40%-85%
Power Supply 220V, 50/60HZ
External Size (WxDxH)(mm) 830x650x560
Shipping Size (WxDxH)(mm) 1000x780x810
N.W./G.W. (kg) 110/130
Standard Accessory Software, Cd Hollow cathode lamp, Pipette
Optional Accessory Computer, Printer, Autosampler, Recirculating cooling water system

Reviews

There are no reviews yet.

Be the first to review “Atomic Absorption Spectrophotometer”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsAtomic Absorption Spectrophotometer removeDiscover 14 Panel Cup with Adulterants Per Pack removeMotic BA210 Series Biomedical Microscope removeAvalun 48 INR Microcuvette removeSugentech Inclix (POCT) Immunoassay Analyzer removeErma B-111 Bilirubin Meter remove
NameAtomic Absorption Spectrophotometer removeDiscover 14 Panel Cup with Adulterants Per Pack removeMotic BA210 Series Biomedical Microscope removeAvalun 48 INR Microcuvette removeSugentech Inclix (POCT) Immunoassay Analyzer removeErma B-111 Bilirubin Meter remove
ImageDrug Test CupAvalun 48 INR Microcuvette
SKUSF1033560130127-34SF1033560084-28SF1033560084-78SF1033560084-74SF1033560084-89SF1033560084-6
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$715.00

Stock

Out of stock

AvailabilityOut of stock
Add to cart

DescriptionShipped From Abroad The atomic absorption spectrophotometer is widely used in the analysis of major and trace elements in metallurgy, geology, mining, petroleum, light industry, agriculture, medicine, health, food and environmental monitoring.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self contained and the entire cup is tamper resistant. Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock The BA210 series is a line of basic biological microscopes manufactured by Motic. The unit is equipped with Motic Infinity Optics (CCIS®, offering quality performance in the fields of education and training. The device features a coaxial coarse and fine housing with a quadruple reverse-mounted nose piece. Its contrast methods, such as phase contrast, polarization and dark field, are easily performed through optional accessories. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Out stock LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock INCLIX™ is an immunochromatographic analyzer providing immediate point-of-care testing (POCT) at patient care settings or clinical laboratories. It facilitates automatic detection of various biomarkers for cardiovascular disease, infectious disease, cancer, diabetes, allergy, and etc. with high accuracy and sensitivity. INCLIX™ analyzer is a compact, easy-to-use and cost-effective multi-parameter POCT instrument and its unique user friendly software provides an efficient data management system. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped From Aboard  The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Atomic Absorption Spectrophotometer Features:
  1. Equipped with a complete software and hardware system, it is highly intelligent, easy to use and simple to operate, and meets the requirements of authority management, audit tracking and other requirements.
  2. It has both flame and graphite furnace atomizers. The two test modes can be switched freely and matched automatically.
  3. Fully automatic eight-lamp position rotating lamp stand, automatic switching, free setting of work lamp/preheating lamp, automatic call of optimal analysis parameters and analysis conditions.
  4. Total reflection optical system, full-band achromatic, automatic wavelength scanning, automatic peak search.
  5. Both the flame and graphite furnace systems have deuterium lamps and self-priming background subtraction to meet the detection needs of complex matrix samples.
  6. Full titanium burner, stable combustion and fast heat balance.
  7. Longitudinal heating graphite furnace technology achieves uniform temperature of the graphite tube.
  8. Reliable multiple protection systems, real-time flame monitoring, acetylene leakage monitoring and protection, real-time monitoring of abnormal pressure, and cooling water monitoring.
  9. The graphite furnace atomization system has alarm functions for insufficient cooling water flow, insufficient argon pressure, excessive temperature of the graphite furnace, abnormal power supply temperature, and poor contact during graphite tube installation, and automatically cuts off the temperature rise program to ensure the safety of the operation and use process.
Advantages
1.Equipped with a complete software and hardware system, it is highly intelligent, easy to use and simple to operate, and meets the requirements of authority management, audit tracking and other requirements. 2.It has both flame and graphite furnace atomizers. The two test modes can be switched freely and matchedautomatically. 3.Fully automatic eight-lamp position rotating lamp stand, automatic switching, free setting of work lamp/preheating lamp, automatic call of optimal analysis parameters and analysis conditions.
Applications
The Atomic Absorption Spectrophotometer is widely used in the analysis of major and trace elements in metallurgy, geology, mining, petroleum, light industry, agriculture, medicine, health, food and environmental monitoring.  
Atomic Absorption Spectrophotometer Specifications:
Model SP-AA3638 SP-AA3668
Optical System Optical System Single Beam Double Beam
Monochromator Czerny-Turner type, focal lengths at 350mm
Grating Grating 1800 lines/mm, scintillation wavelength 250nm
Spectral Bandwidth (nm) 0.1, 0.2, 0.4, 0.7, 1.4, 2nm
Automated slit selection
Wavelength Range (nm) 185-900nm
Wavelength Accuracy (nm) 0.20 nm 0.15nm
Wavelength Repeatability (nm) ≤0.10nm ≤0.05nm
Spectral Bandwidth Deviation ±0.02 nm
Lamp Stand 8
Element Lamp Type Cu lamp, Cd lamp(Standard accessory)
Other element lamp is optional accessory
Photometric Performance Reading Mode Transmittance, absorbance, concentration
Photometric Range 0-125%, -0.1-3.00A
Static Baseline Drift (Cu) ±0.003A/30min ±0.003A/30min
Dynamic Baseline Drift (Cu) ±0.005A/15min ±0.005A/15min
Background Correction Deuterium lamp≥ 40x (1Abs), self-priming≥ 80x (1Abs) (optional) Deuterium lamp≥ 40x (1Abs), self-priming≥ 80x (1Abs) (optional)
Flame System Characteristic Concentration (Cu) ≤0.035ug/ml ≤0.035ug/ml
Detection Limit (Cu) ≤0.006ug/ml ≤0.004ug/ml
Repeatability (Cu) RSD≤0.6% RSD≤0.5%
Acetylene Flow Control Auto 12-Level
Air Assist Control Auto 4-Level
Burner Lift Automatic lifting
Burner Head Titanium 100mm burner
Nebulizer High efficiency glass nebulizer
Spray Chamber Corrosion-resistant material spray chamber
Safety Protection Automatically cut off gas in case of low pressure, power failure, flame out, or burner mismatched
Graphite Furnace Characteristic Amount Cd≤0.8pg,Cu≤20pg Cd≤0.8pg,Cu≤20pg
Detection Limit Cd≤1.0pg,Cu≤10pg Cd≤0.8pg,Cu≤5pg
Repeatability(Cd) RSD≤3% RSD≤2.5%
Heating Range of Graphite Furnace Room temperature-3000℃
High Power Heating Range 1500-3000℃
Slope and Holding Time 1s-255s
Heating Rate Maximum heating rate 2000°C/s
Atomization Heating Mode Light-controlled heating, Time-controlled heating, General heating
Protective Gas Flow Outside Pipe 1 L/min
Protective Gas Flow Inside Pipe 4-speed adjustable (0, 50, 200, 250ml/min flow)
Safety Protection Cooling water flow, Protective gas pressure, Furnace body temperature, Power supply temperature, Graphite furnace installation alarm
Data Processing Measuring Method Measuring method
Concentration Calculation Method Concentration calculation method
Repeat Measurement Times Repeat measurement times
Report Printing Report printing
Other Computer External connect
Ambient Temp 10℃-30℃
Ambient Humidity 40%-85%
Power Supply 220V, 50/60HZ
External Size (WxDxH)(mm) 830x650x560
Shipping Size (WxDxH)(mm) 1000x780x810
N.W./G.W. (kg) 110/130
Standard Accessory Software, Cd Hollow cathode lamp, Pipette
Optional Accessory Computer, Printer, Autosampler, Recirculating cooling water system
All-in-One Design
FDA 510(K) & CLIA Waived Up to 99% accuracy rate Results in as little as 1 minute 24 Month Shelf Life from Date of Manufacture Secure, seal and send to lab for confirmation Built in temperature strip Available to test up to 17 substances with adulterants or 18 without adulterants Adulterants available
 
 
The BA210 series is a line of basic biological microscopes manufactured by Motic. The unit is equipped with Motic Infinity Optics (CCIS®, offering quality performance in the fields of education and training. The device features a coaxial coarse and fine housing with a quadruple reverse-mounted nose piece. Its contrast methods, such as phase contrast, polarization and dark field, are easily performed through optional accessories. Technical applications: Biomedical Type: Optical Observation technique: Dark field Magnification: 4 unit, 10 unit, 40 unit, 100 unit  
LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users.
Features:
  • Fully automated "plug-and-play"   behavior
  • Reduced blood volume (only 3µL)
  • A large space for blood drop-off
  • Fills up quickly, using just capillarity
  • Easy handling, thanks to its 3D shape
  • Optimized preservation in individual pouches, in boxes of 12, 24, or 48 units
INCLIX™ is an immunochromatographic analyzer providing immediate point-of-care testing (POCT) at patient care settings or clinical laboratories. It facilitates automatic detection of various biomarkers for cardiovascular disease, infectious disease, cancer, diabetes, allergy, and etc. with high accuracy and sensitivity. INCLIX™ analyzer is a compact, easy-to-use and cost-effective multi-parameter POCT instrument and its unique user friendly software provides an efficient data management system. Features: • Good accuracy owning to superior CMOS sensor & our own Algorism • 10,000 test results data storage • Instrument Check by Reference Kit • Remote Support available (when connected via Internet) • Built-in Thermal Printer and Barcode Scanner • Data export to USB(PDF, Excel), Email and LIS • Storage Temperature of Test Cassette & Buffer : Room temperature, 2 ~ 30 ℃ • Shelf Life of Test Cassette & Buffer : 24 months  
Click Here To Download Catalogue
 
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin. Feature
  • Auto zero function: Manual blanking not required
  • Dual wavelength measurement system:
  • 2 wave lengths 455nm and 575nm
  • Plays major role to remove the interference caused due to Hemolysis & turbidity of sample
  • LED Light source:
  • LED does not require replacement as it lasts longer
  • As compared to Lamp, LED are more suitable as there is no intensity fluctuations
  • No warm up time required.
  • Flexible unit selection:
  • Two units either mg/dl or umol/L are selectable, ease of reporting
  • Compact slot for Capillary:
  • Accuracy of results are directly related to proper alignment of Capillary
  • B-111 has the easiest mode to ensure precise values
  • Data transfer:
  • External device can be connected to instrument through RS232 por
  • USB port
Technical Specification
  • Light source - LED
  • Wavelength - 455nm and 575nm
  • Net weight - 1kg
  • Measuring range - 0-30 mg/dl , 510 umol/L
  • Display - 16×2 LCD module with backlight
  • Auto calibration - Yes
  • Sample type - Serum or plasma
  • Sample volume - 40-80μL
  • Test time - <5sec
  • Units - mg/dl or umol/L
  • Dimensions - 150 (W) × 115 (H) × 190 (D) mm
  • Interface - RS232
  • Reading cuvette - Heparinized micro capillary holder
  • Storage temperature - 15-40°c
  • Power supply - DC 9V(DC adapter)
  • Power consumption - <2W
WeightN/AN/AN/AN/AN/AN/A