This Atomic Absorption Spectrophotometer measures the concentration of specific elements in a sample by analyzing the wavelengths of light absorbed by free atoms. This technique is highly sensitive and widely used in fields like environmental analysis, food safety, and clinical diagnostics to detect trace elements and metals.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130127-70
Brands:: Scitek

Description

Atomic Absorption Spectrophotometer Features:

The atomic absorption spectrophotometer is PC-controlled and uses advanced graphite furnace temperature control technology. Its unique optical and mechanical design and various convenient features make it ideal for various industries. Here are some of its features:

1. Complete automatic control system, fully PC controlled. You can quickly realize:

  • Automatic ignition and extinguishing
  • Graphite furnace test method setting wavelength scanning and peak seeking determination
  • Selection of atomizer
  • Gas flow control
  • Advanced graphite furnace temperature control technology
  • The setting of the background deduction method
  • Elevator up and down front and back adjustment
  • Adjustment of light energy

2. Integrated floated optical platform design can improve the visual system shock resistance and keep it stable though using the optical signal for a long time.

3. The flame burner can automatically adjust the optimum height

4. Simultaneous preheating of eight lamps with automatic change of selection

5. Fully automatic peak search and wavelength scanning

6. Full range of safety features, including flame anomalies, gas leaks, under-pressure alarms and automatic safety protection.

7. Self-absorbing background and deuterium lamp adjustment

8. Superior data processing capability

Advanced Graphite Furnace Temperature Controlling Technology

1. PID technology ensures more accurate temperature control even with voltage fluctuations and resistance changes.

2. Fast sampling techniques are used to obtain reliable test data

3. The furnace has a fast heat-up capability for increased component flexibility

4. It can be powered by a 220V power supply with a maximum heating capacity set to 20 levels for testing different samples

5. Can adjust the gas flow  to three different levels to suit a variety of applications

6. The Atomic absorption spectrophotometer has an alarm system that alerts the user during a low gas or water supply.

Safe and reliable flame system

1. EPC for more precise control of acetylene (C2H2) flow and easier handling

2. Highly efficient atomization system for higher sensitivity

3. High safety with automatic alarms for flame anomalies, power failures, insufficient pressure, etc.

4. Automatic gas shut-off in case of abnormality

Multifunctional Software Workstation

Supports WINDOWS7

1. Rich menus make operation more convenient

2. Convenient conversion between different menus makes the process easier.

3. Multiple analysis and correction methods provide users with more choices.

4. Supports flexible storage and editing

 

Atomic Absorption Spectrophotometer Specifications:
Model SP-AA4530
Wavelength Range 190-900nm
Spectral Bandwidth 0.1/0.2/0.4/1.0/2.0 nm
Accuracy of the Wavelength ±0.15nm
Receptivity of the Wavelength ≤0.04nm
Base Line Stability ≤0.002A/30min (Cu)
Characteristic Viscosity 0.02μg/ml/1% (Cu)
Checking Limit 0.004μg/ml (Cu)
Preciseness 0.005
Grating 1800 lines/mm
Inflamer All-metal titanium burner
Atomizer Effective glass atomizer
Lamp Stand 8
D2 Background Correction Ability When the background is 1A, the background ability should be deducted not less than 50 times, self absorption background deduction method
Power Source 220V±22V AC
Shipping Size(W×D×H)(mm) 860×705×755(Main instrument)
1170×645×900(Accessories)
G.W. (kg) 105 (Main instrument); 100 (Accessories)
Flame System
Acetylene Air Burner 100mm
Lgnition Dynamic Baseline Drift ≤0.006A/30min
(Cu) Characteristic Viscosity ≤0.025μg/ml/1%
Related Standard Deviation of the Accuracy ≤0.5% (Cu, absorbance>0.8A) (detection limit Cu≤0.008μg/ml)
Safety System Can automatically cut off the gas when the pressure is not enough the power is off flame out and unconformity of the burner
Graphite Furnace
The Highest Temperature 3000℃
The Largest Temperature Rising Speed ≥2000℃/s
Characteristic Quantity Cd≤0.5×10-12g Cu≤0.5×10-11g
Accuracy Cu≤3% Cd≤3%
Size (mm) and Weight 730×625×700; 79.3kg
Safety System Over current protection
Low air pressure alarm/protection
Low cooling water flow alarm/protection
Power Source and Power 220V±22V AC 7000W

Quick Comparison

SettingsAtomic Absorption Spectrophotometer removeSkyla HB1 POC Clinical Chemistry Auto Analyzer removeNikon SMZ745 Stereoscopic Microscope removeAGD Erma EL-120 ELectrolyte Analyzer removeSkyla Hi POC Clinical Chemistry Analyzer removeDiscover 14 Panel Cup with Adulterants Per Pack remove
NameAtomic Absorption Spectrophotometer removeSkyla HB1 POC Clinical Chemistry Auto Analyzer removeNikon SMZ745 Stereoscopic Microscope removeAGD Erma EL-120 ELectrolyte Analyzer removeSkyla Hi POC Clinical Chemistry Analyzer removeDiscover 14 Panel Cup with Adulterants Per Pack remove
ImageNikon SMZ745 Stereoscopic MicroscopeDrug Test Cup
SKUSF1033560130127-70SF1033560060-1SF1033560084-49SF1033560084-125SF1033560060-2SF1033560084-28
Rating
Price

$0.00

$0.00

$0.00

$1,320.00

$0.00

$0.00

Add to cart
DescriptionShipped From Abroad Model : SP-AA4530 This Atomic Absorption Spectrophotometer measures the concentration of specific elements in a sample by analyzing the wavelengths of light absorbed by free atoms. This technique is highly sensitive and widely used in fields like environmental analysis, food safety, and clinical diagnostics to detect trace elements and metals.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The skyla HB1 Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. The portable design of the clinical chemistry analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock Nikon SMZ745 Stereoscopic Microscope: Featuring a zoom magnification of 7.5X and a long working distance of 115mm, Nikon SMZ745 microscopes are well suited for both industrial and biomedical applications. The adoption of a new total reflection prism produces brighter images with higher contrast, and the anti-mold design allows the microscope to be used in environments where the temperature and humidity are high. The SMZ-745T trinocular model comes equipped with a microscope camera port and a built-in 0.55x c-mount adapter, permitting direct mounting of Nikon DS Series Digital Cameras. Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped From Abroad
Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The skyla Hi POC Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results.The use of skyla Hi in the management of diabetes enables better access to testing and rapid clinical decision making, discussion,and implementation of optimized treatment. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self contained and the entire cup is tamper resistant. Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Atomic Absorption Spectrophotometer Features:
The atomic absorption spectrophotometer is PC-controlled and uses advanced graphite furnace temperature control technology. Its unique optical and mechanical design and various convenient features make it ideal for various industries. Here are some of its features: 1. Complete automatic control system, fully PC controlled. You can quickly realize:
  • Automatic ignition and extinguishing
  • Graphite furnace test method setting wavelength scanning and peak seeking determination
  • Selection of atomizer
  • Gas flow control
  • Advanced graphite furnace temperature control technology
  • The setting of the background deduction method
  • Elevator up and down front and back adjustment
  • Adjustment of light energy
2. Integrated floated optical platform design can improve the visual system shock resistance and keep it stable though using the optical signal for a long time. 3. The flame burner can automatically adjust the optimum height 4. Simultaneous preheating of eight lamps with automatic change of selection 5. Fully automatic peak search and wavelength scanning 6. Full range of safety features, including flame anomalies, gas leaks, under-pressure alarms and automatic safety protection. 7. Self-absorbing background and deuterium lamp adjustment 8. Superior data processing capability Advanced Graphite Furnace Temperature Controlling Technology 1. PID technology ensures more accurate temperature control even with voltage fluctuations and resistance changes. 2. Fast sampling techniques are used to obtain reliable test data 3. The furnace has a fast heat-up capability for increased component flexibility 4. It can be powered by a 220V power supply with a maximum heating capacity set to 20 levels for testing different samples 5. Can adjust the gas flow  to three different levels to suit a variety of applications 6. The Atomic absorption spectrophotometer has an alarm system that alerts the user during a low gas or water supply. Safe and reliable flame system 1. EPC for more precise control of acetylene (C2H2) flow and easier handling 2. Highly efficient atomization system for higher sensitivity 3. High safety with automatic alarms for flame anomalies, power failures, insufficient pressure, etc. 4. Automatic gas shut-off in case of abnormality Multifunctional Software Workstation Supports WINDOWS7 1. Rich menus make operation more convenient 2. Convenient conversion between different menus makes the process easier. 3. Multiple analysis and correction methods provide users with more choices. 4. Supports flexible storage and editing  
Atomic Absorption Spectrophotometer Specifications:
Model SP-AA4530
Wavelength Range 190-900nm
Spectral Bandwidth 0.1/0.2/0.4/1.0/2.0 nm
Accuracy of the Wavelength ±0.15nm
Receptivity of the Wavelength ≤0.04nm
Base Line Stability ≤0.002A/30min (Cu)
Characteristic Viscosity 0.02μg/ml/1% (Cu)
Checking Limit 0.004μg/ml (Cu)
Preciseness 0.005
Grating 1800 lines/mm
Inflamer All-metal titanium burner
Atomizer Effective glass atomizer
Lamp Stand 8
D2 Background Correction Ability When the background is 1A, the background ability should be deducted not less than 50 times, self absorption background deduction method
Power Source 220V±22V AC
Shipping Size(W×D×H)(mm) 860×705×755(Main instrument)
1170×645×900(Accessories)
G.W. (kg) 105 (Main instrument); 100 (Accessories)
Flame System
Acetylene Air Burner 100mm
Lgnition Dynamic Baseline Drift ≤0.006A/30min
(Cu) Characteristic Viscosity ≤0.025μg/ml/1%
Related Standard Deviation of the Accuracy ≤0.5% (Cu, absorbance>0.8A) (detection limit Cu≤0.008μg/ml)
Safety System Can automatically cut off the gas when the pressure is not enough the power is off flame out and unconformity of the burner
Graphite Furnace
The Highest Temperature 3000℃
The Largest Temperature Rising Speed ≥2000℃/s
Characteristic Quantity Cd≤0.5×10-12g Cu≤0.5×10-11g
Accuracy Cu≤3% Cd≤3%
Size (mm) and Weight 730×625×700; 79.3kg
Safety System Over current protection
Low air pressure alarm/protection
Low cooling water flow alarm/protection
Power Source and Power 220V±22V AC 7000W
Skyla HB1 Clinical Chemistry Analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. HB1 provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. Only needs 200µl of blood (whole blood, serum or plasma is accepted.) and no sample preparation is required. All steps are designed automatically from checking the validity of reagent discs and cartridges to printing the results. Over 30 test parameters are allowed with fast analysis and results in 15 minutes. Internal Quality Control (IQC) with self-calibration of optical system, chemicals stability and interference alerts functions monitor and ensure the results with high accuracy. Available Test Panels
  • Renal Function - BUN, CREA eGFR
  • Liver Function - ALB, TP, ALP, ALT, AST, TBIL, DBIL, GGT, LDH A/G#, GLOB#, IBIL
  • Lipid Metabolism - TG, TC, HDL LDL#, VLDL
  • Pancreatitis Markers - AMY, LIPA
  • Carbohydrate Metabolism and Others - GLU , CPK, UA, LAC
  • Inflammatory Markers - CRP
  • Electrolyte - Na, K, Cl, Ca, PHOS, Mg, tCO2
SPECIFICATION Principle
  • Colormetric System : LEDs 340nm~940nm wavelength
Sample & Panel
  • Test Profiles : Panels
  • Measurement Time - Panel: up to 15 tests/ 15 min
  • Sample Type & Volume : 200 μl whole blood (PCV<60%), plasma, serum 
Device
  • User Interface : 5 inch color LCD touch screen
  • Internal Memory : Store up to 50,000 analysis results
  • Printer : Built in thermal printer or external USB printer (PCL 3GUI)
  • USB Socket : USB type A (Host) for external USB Printer, USB flash drive (FAT) or external barcode scanner
  • Data transmission to PC : RS232 serial port or RJ45 (LAN)
  • Dimensions : 233 (W) X 285 (D) X 300 (H) mm
  • Weight : 5.5 kg
Operating Condition
  • Temperature / Humidity : 10 to 32˚C / 5 to 90 %
 
Click Here To Download Catalogue
Nikon SMZ745 Stereoscopic Microscope: Featuring a zoom magnification of 7.5X and a long working distance of 115mm, Nikon SMZ745 microscopes are well suited for both industrial and biomedical applications. The adoption of a new total reflection prism produces brighter images with higher contrast, and the anti-mold design allows the microscope to be used in environments where the temperature and humidity are high. The SMZ-745 trinocular model comes equipped with a microscope camera port and a built-in 0.55x c-mount adapter, permitting direct mounting of Nikon DS Series Digital Cameras. Features:
  • Trinocular optical head for monitoring and digital imaging
  • Impressive 7.5x zoom magnification
  • 115 mm working distance
  • Maximum ergonomics
  • Rugged, durable design suits a variety of applications and environments
Technical Specifications:
Optical system Greenough optical system
Total magnification 3.35-300x, depending on eyepiece and auxiliary objective used
Vertical tube Built-in C-mount 0.55x magnification lens (F.N. 11), compatible with 2/3 in. or smaller CCD
Eyepiece tube Fixed type
Eyepiece inclination 45°
Interpupillary distance adjustment 52-75 mm
Eyepieces (with diopter adjustment) C-W 10xB (F.N. 22), C-W 15x (F.N. 16), C-W 20x (F.N. 12.5), C-W 30x (F.N. 7)
Zooming ratio 7.5:1 (approx.)
Zooming range 0.67-5x
Auxiliary objectives G-AL 0.5x (W.D. 211 mm), G-AL 0.7x (W.D. 150 mm), G-AL 1.5x (W.D. 61 mm), G-AL 2x (W.D. 43.5 mm)
Working distance 115 mm
     
 
 
Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface. Features:
  • Parameters: Na+,K+,Cl-, iCa++ / Li
  • It works on ISE principle
  • Sample Type: Whole blood, Serum, Plasma, Urine
  • Low reagent consumption
  • Sample requirement is only 90ul
  • 60 samples per hour
  • Automatic two point calibration after 4hrs and one point calibration with each sample analysis
  • Air bubble detection
  • Track reagents consumption and provides alerts
  • For low reagent volume
  • Precision testing facility to get CV and SD
  • Trilevel Quality Control with LJ plots of last 30days
  • Low aspiration volume
  • Fast sample processing
  • Accurate and Precise results
Technical Specifications:
Parameters Na+, K+, Cl– /Ca++
Principle Ion Selective Electrode (ISE)
Sample Type Analyses whole blood, serum, plasma and urine
Sample Volume ≤100 µL
Analysis Time ≤60 seconds
Throughout ≤60 samples per hour
Data Link Serial (RS232)
External Interface USB (Keyboard, Mouse)
Operating Condition 10° C to 35° C, Relative Humidity up to 85%
Storage Condition Temp: 10° C to 40° C
Relative Humidity up to 85% non- condensing
Power Supply 100 to 240 VAC ±10%, 50Hz
Dimensions 395 x 260 x 375 mm
Weight 7.5 kg
 
Click Here To Download Catalogue
skyla Hi Analyzer enables better access to testing and rapid clinical decision making, discussion, and implementation of optimized treatment. To get the result, only prepare <1 μl fingertips blood or venous blood (depends on test item) without pretreatment with easy steps and then read the result after 6 mins. The device allows two specimens be tested in one run and provides fully automatic procedures from checking the validity of cartridge to printing the results. Reagent Kit
  • HbA1C
  • CRP
  • Lipid Panel (TC,TG, HDL, LDL#)
  • Lipid Plus Panel (Glu,TC,TG, HDL, LDL#)
Main Specification
Principle
Turbidimetric Method / Biochemistry
Device
Testing Time
5~20 minutes (depends on test items)
Display and Interface
5″ TFT color touch screen LCD
Memory Capacity
50,000 test results
Dimension of Analyzer
270 x 188 x 148 mm
Weight of Analyzer
1.7 kg
Dimension of Printer Module
134 x 100 x 82.7 mm
Weight of Printer Module
0.37 kg
Power Supply
100~240 volts AC, 50-60Hz
Data Transmission
USB 2.0*4 / USB 3.0*1 / RS232*1 / RJ45*1 / Wi-Fi (optional)
Reagent and Samples
Samples
Fingertips blood or venous blood
Samples Volume
0.8 ~ 30 μL (depends on test item)
Storage Temperature (Reagent)
2 ~ 8˚C
Humidity
Relative humidity < 95% (Non-condensing)
Temperature
10 ~ 32 ˚C
Click Here To Download Catalogue
All-in-One Design
FDA 510(K) & CLIA Waived Up to 99% accuracy rate Results in as little as 1 minute 24 Month Shelf Life from Date of Manufacture Secure, seal and send to lab for confirmation Built in temperature strip Available to test up to 17 substances with adulterants or 18 without adulterants Adulterants available
 
 
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
en English
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare