This Atomic Absorption Spectrophotometer measures the concentration of specific elements in a sample by analyzing the wavelengths of light absorbed by free atoms. This technique is highly sensitive and widely used in fields like environmental analysis, food safety, and clinical diagnostics to detect trace elements and metals.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130127-70
Brands:: Scitek

Description

Atomic Absorption Spectrophotometer Features:

The atomic absorption spectrophotometer is PC-controlled and uses advanced graphite furnace temperature control technology. Its unique optical and mechanical design and various convenient features make it ideal for various industries. Here are some of its features:

1. Complete automatic control system, fully PC controlled. You can quickly realize:

  • Automatic ignition and extinguishing
  • Graphite furnace test method setting wavelength scanning and peak seeking determination
  • Selection of atomizer
  • Gas flow control
  • Advanced graphite furnace temperature control technology
  • The setting of the background deduction method
  • Elevator up and down front and back adjustment
  • Adjustment of light energy

2. Integrated floated optical platform design can improve the visual system shock resistance and keep it stable though using the optical signal for a long time.

3. The flame burner can automatically adjust the optimum height

4. Simultaneous preheating of eight lamps with automatic change of selection

5. Fully automatic peak search and wavelength scanning

6. Full range of safety features, including flame anomalies, gas leaks, under-pressure alarms and automatic safety protection.

7. Self-absorbing background and deuterium lamp adjustment

8. Superior data processing capability

Advanced Graphite Furnace Temperature Controlling Technology

1. PID technology ensures more accurate temperature control even with voltage fluctuations and resistance changes.

2. Fast sampling techniques are used to obtain reliable test data

3. The furnace has a fast heat-up capability for increased component flexibility

4. It can be powered by a 220V power supply with a maximum heating capacity set to 20 levels for testing different samples

5. Can adjust the gas flow  to three different levels to suit a variety of applications

6. The Atomic absorption spectrophotometer has an alarm system that alerts the user during a low gas or water supply.

Safe and reliable flame system

1. EPC for more precise control of acetylene (C2H2) flow and easier handling

2. Highly efficient atomization system for higher sensitivity

3. High safety with automatic alarms for flame anomalies, power failures, insufficient pressure, etc.

4. Automatic gas shut-off in case of abnormality

Multifunctional Software Workstation

Supports WINDOWS7

1. Rich menus make operation more convenient

2. Convenient conversion between different menus makes the process easier.

3. Multiple analysis and correction methods provide users with more choices.

4. Supports flexible storage and editing

 

Atomic Absorption Spectrophotometer Specifications:
Model SP-AA4530
Wavelength Range 190-900nm
Spectral Bandwidth 0.1/0.2/0.4/1.0/2.0 nm
Accuracy of the Wavelength ±0.15nm
Receptivity of the Wavelength ≤0.04nm
Base Line Stability ≤0.002A/30min (Cu)
Characteristic Viscosity 0.02μg/ml/1% (Cu)
Checking Limit 0.004μg/ml (Cu)
Preciseness 0.005
Grating 1800 lines/mm
Inflamer All-metal titanium burner
Atomizer Effective glass atomizer
Lamp Stand 8
D2 Background Correction Ability When the background is 1A, the background ability should be deducted not less than 50 times, self absorption background deduction method
Power Source 220V±22V AC
Shipping Size(W×D×H)(mm) 860×705×755(Main instrument)
1170×645×900(Accessories)
G.W. (kg) 105 (Main instrument); 100 (Accessories)
Flame System
Acetylene Air Burner 100mm
Lgnition Dynamic Baseline Drift ≤0.006A/30min
(Cu) Characteristic Viscosity ≤0.025μg/ml/1%
Related Standard Deviation of the Accuracy ≤0.5% (Cu, absorbance>0.8A) (detection limit Cu≤0.008μg/ml)
Safety System Can automatically cut off the gas when the pressure is not enough the power is off flame out and unconformity of the burner
Graphite Furnace
The Highest Temperature 3000℃
The Largest Temperature Rising Speed ≥2000℃/s
Characteristic Quantity Cd≤0.5×10-12g Cu≤0.5×10-11g
Accuracy Cu≤3% Cd≤3%
Size (mm) and Weight 730×625×700; 79.3kg
Safety System Over current protection
Low air pressure alarm/protection
Low cooling water flow alarm/protection
Power Source and Power 220V±22V AC 7000W

Quick Comparison

SettingsAtomic Absorption Spectrophotometer removeEppendorf Pipette Tip 200ul Per Pack removePlastic Urine Container Per Pack removeEppendorf Pipette Tip 20ul Per Pack removeErma B-111 Bilirubin Meter removeAutomatic Pipette remove
NameAtomic Absorption Spectrophotometer removeEppendorf Pipette Tip 200ul Per Pack removePlastic Urine Container Per Pack removeEppendorf Pipette Tip 20ul Per Pack removeErma B-111 Bilirubin Meter removeAutomatic Pipette remove
ImageEppendorf Pipette Tip 200ul Per PackEppendorf Pipette Tip 20ul Per Pack
SKUSF1033560130127-70SF1033560084-137SF1033560084-106SF1033560084-136SF1033560084-6SF1033560084-130
Price

$0.00

$0.00

$8.20

$0.00

$715.00

$0.00

Add to cart
DescriptionShipped From Abroad Model : SP-AA4530 This Atomic Absorption Spectrophotometer measures the concentration of specific elements in a sample by analyzing the wavelengths of light absorbed by free atoms. This technique is highly sensitive and widely used in fields like environmental analysis, food safety, and clinical diagnostics to detect trace elements and metals.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Made of high quality PP material with good transparency.
  • Applied for Gilson/Finland/Eppendorf Pipettors.
  • Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
  • Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
  • Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Total Volume: 60mL.
  • Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
  • Made of premium PP material, it is durable for usage.
  • Some measurements can be used to not only use urine samples, it can also be used for other liquids.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Made of high quality PP material with good transparency.
  • Applied for Gilson/Finland/Eppendorf Pipettors.
  • Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
  • Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
  • Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Aboard  The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
This Automatic Pipette will help you get your lab up and running in no time—at a great price! Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Atomic Absorption Spectrophotometer Features:
The atomic absorption spectrophotometer is PC-controlled and uses advanced graphite furnace temperature control technology. Its unique optical and mechanical design and various convenient features make it ideal for various industries. Here are some of its features: 1. Complete automatic control system, fully PC controlled. You can quickly realize:
  • Automatic ignition and extinguishing
  • Graphite furnace test method setting wavelength scanning and peak seeking determination
  • Selection of atomizer
  • Gas flow control
  • Advanced graphite furnace temperature control technology
  • The setting of the background deduction method
  • Elevator up and down front and back adjustment
  • Adjustment of light energy
2. Integrated floated optical platform design can improve the visual system shock resistance and keep it stable though using the optical signal for a long time. 3. The flame burner can automatically adjust the optimum height 4. Simultaneous preheating of eight lamps with automatic change of selection 5. Fully automatic peak search and wavelength scanning 6. Full range of safety features, including flame anomalies, gas leaks, under-pressure alarms and automatic safety protection. 7. Self-absorbing background and deuterium lamp adjustment 8. Superior data processing capability Advanced Graphite Furnace Temperature Controlling Technology 1. PID technology ensures more accurate temperature control even with voltage fluctuations and resistance changes. 2. Fast sampling techniques are used to obtain reliable test data 3. The furnace has a fast heat-up capability for increased component flexibility 4. It can be powered by a 220V power supply with a maximum heating capacity set to 20 levels for testing different samples 5. Can adjust the gas flow  to three different levels to suit a variety of applications 6. The Atomic absorption spectrophotometer has an alarm system that alerts the user during a low gas or water supply. Safe and reliable flame system 1. EPC for more precise control of acetylene (C2H2) flow and easier handling 2. Highly efficient atomization system for higher sensitivity 3. High safety with automatic alarms for flame anomalies, power failures, insufficient pressure, etc. 4. Automatic gas shut-off in case of abnormality Multifunctional Software Workstation Supports WINDOWS7 1. Rich menus make operation more convenient 2. Convenient conversion between different menus makes the process easier. 3. Multiple analysis and correction methods provide users with more choices. 4. Supports flexible storage and editing  
Atomic Absorption Spectrophotometer Specifications:
Model SP-AA4530
Wavelength Range 190-900nm
Spectral Bandwidth 0.1/0.2/0.4/1.0/2.0 nm
Accuracy of the Wavelength ±0.15nm
Receptivity of the Wavelength ≤0.04nm
Base Line Stability ≤0.002A/30min (Cu)
Characteristic Viscosity 0.02μg/ml/1% (Cu)
Checking Limit 0.004μg/ml (Cu)
Preciseness 0.005
Grating 1800 lines/mm
Inflamer All-metal titanium burner
Atomizer Effective glass atomizer
Lamp Stand 8
D2 Background Correction Ability When the background is 1A, the background ability should be deducted not less than 50 times, self absorption background deduction method
Power Source 220V±22V AC
Shipping Size(W×D×H)(mm) 860×705×755(Main instrument)
1170×645×900(Accessories)
G.W. (kg) 105 (Main instrument); 100 (Accessories)
Flame System
Acetylene Air Burner 100mm
Lgnition Dynamic Baseline Drift ≤0.006A/30min
(Cu) Characteristic Viscosity ≤0.025μg/ml/1%
Related Standard Deviation of the Accuracy ≤0.5% (Cu, absorbance>0.8A) (detection limit Cu≤0.008μg/ml)
Safety System Can automatically cut off the gas when the pressure is not enough the power is off flame out and unconformity of the burner
Graphite Furnace
The Highest Temperature 3000℃
The Largest Temperature Rising Speed ≥2000℃/s
Characteristic Quantity Cd≤0.5×10-12g Cu≤0.5×10-11g
Accuracy Cu≤3% Cd≤3%
Size (mm) and Weight 730×625×700; 79.3kg
Safety System Over current protection
Low air pressure alarm/protection
Low cooling water flow alarm/protection
Power Source and Power 220V±22V AC 7000W
  • Made of high quality PP material with good transparency.
  • Applied for Gilson/Finland/Eppendorf Pipettors.
  • Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
  • Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
  • Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
  Classification: PIPETTE Brand Name: Vchanslab,Yingmed,OEM Model Number: YM-K7028 Place of Origin: China Product name: Pipette Tips Material: Polypropylene Certificate: CE/ISO13485/FDA Color: Natural, Blue, Yellow Application: Laboratory, Teaching, Hospital
  • Total Volume: 60mL.
  • Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
  • Made of premium PP material, it is durable for usage.
  • Some measurements can be used to not only use urine samples, it can also be used for other liquids.
  • Made of high quality PP material with good transparency.
  • Applied for Gilson/Finland/Eppendorf Pipettors.
  • Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
  • Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
  • Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
  Classification: PIPETTE Brand Name: Vchanslab,Yingmed,OEM Model Number: YM-K7028 Place of Origin: China Product name: Pipette Tips Material: Polypropylene Certificate: CE/ISO13485/FDA Color: Natural, Blue, Yellow Application: Laboratory, Teaching, Hospital
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin. Feature
  • Auto zero function: Manual blanking not required
  • Dual wavelength measurement system:
  • 2 wave lengths 455nm and 575nm
  • Plays major role to remove the interference caused due to Hemolysis & turbidity of sample
  • LED Light source:
  • LED does not require replacement as it lasts longer
  • As compared to Lamp, LED are more suitable as there is no intensity fluctuations
  • No warm up time required.
  • Flexible unit selection:
  • Two units either mg/dl or umol/L are selectable, ease of reporting
  • Compact slot for Capillary:
  • Accuracy of results are directly related to proper alignment of Capillary
  • B-111 has the easiest mode to ensure precise values
  • Data transfer:
  • External device can be connected to instrument through RS232 por
  • USB port
Technical Specification
  • Light source - LED
  • Wavelength - 455nm and 575nm
  • Net weight - 1kg
  • Measuring range - 0-30 mg/dl , 510 umol/L
  • Display - 16×2 LCD module with backlight
  • Auto calibration - Yes
  • Sample type - Serum or plasma
  • Sample volume - 40-80μL
  • Test time - <5sec
  • Units - mg/dl or umol/L
  • Dimensions - 150 (W) × 115 (H) × 190 (D) mm
  • Interface - RS232
  • Reading cuvette - Heparinized micro capillary holder
  • Storage temperature - 15-40°c
  • Power supply - DC 9V(DC adapter)
  • Power consumption - <2W
This Automatic Pipette will help you get your lab up and running in no time—at a great price! Features:
  • Lowest operation and tip ejection forces
  • Fully autoclavable
  • Ultra light weight with space-age materials
  • Secondary adjustment option for various liquid classes
  • Spring loaded tip con
  • For transferring molecular samples and PCR mix solutions.
  • One set is for DNA work and the other for RNA work. Each with the following specs
  • Light weight, traditional tip shaft, and will fit all generic brands of tips
  • Equal to or better than accuracy and precision compared to ISO 8655, so results can be trusted.
  • Easy and quick volume adjustment with or without gloves. Foolproof volume lock prevents accidental volume changes.
  • Low maintenance and autoclavable 121° for at least 20 minutes
  • Quick release
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
en English
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare