Atomic Absorption Spectrophotometer with Double Beam

$0.00

Shipped From Abroad

Model : SP-AA3618

The atomic absorption spectrophotometer is widely used in the analysis of major and trace elements in metallurgy, geology, mining, petroleum, light industry, agriculture, medicine, health, food and environmental monitoring.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130127-71
Brands:: Scitek

Description

Atomic Absorption Spectrophotometer Features:
  1. The atomic absorption spectrophotometer is quipped with a complete software and hardware system. It is highly intelligent, easy to use and simple to operate, and meets the requirements of authority management, audit tracking and other requirements.
  2. Working methods can be stored, eliminating the need to repeatedly set test conditions, streamlining the detection process, avoiding duplication of work, and greatly saving users’ time and cost.
  3. Fully automatic eight-lamp position rotating lamp stand, automatic switching, free setting of work lamp/preheating lamp, automatic call of optimal analysis parameters and analysis conditions.
  4. Total reflection optical system, full-band achromatic, automatic wavelength scanning, automatic peak search.
  5. It has both deuterium lamp and self-priming background subtraction to meet the detection needs of complex matrix samples.
  6. Full titanium burner, stable combustion and fast heat balance.
  7. Reliable multiple protection systems, real-time flame monitoring, acetylene leakage monitoring and protection, real-time monitoring of abnormal pressure, and cooling water monitoring.
  8. The laughing gas-acetylene flame effectively increases the types of test elements, with a wide analysis range and strong selectivity. Test interference is small.
  9. Paired with the hydride generator produced by our company, it can expand the detection of arsenic, selenium, mercury, and antimony lamp elements, easily cope with the diversified problems of analysis samples, and meet the analysis needs of multiple elements.
  10. An atomic absorption spectrophotometer is optional and can be installed freely.

 

Atomic Absorption Spectrophotometer Specifications:
Model SP-AA3618
Optical System Optical System Double Beam
Monochromator Czerny-Turner type, focal lengths at 350mm
Grating Grating 1800 lines/mm, scintillation wavelength 250nm
Spectral Bandwidth (nm) 0.1, 0.2, 0.4, 0.7, 1.4, 2nm Automated slit selection
Wavelength Range (nm) 185-900nm
Wavelength Accuracy (nm) 0.15 nm
Wavelength Repeatability (nm) ≤0.05nm
Spectral Bandwidth Deviation ±0.02 nm
Lamp Stand 8
Element Lamp Type Cu lamp (Standard accessory)
Other element lamp is optional accessory
Photometric Performance Reading Mode Transmittance, absorbance, concentration
Photometric Range 0-125%, -0.1-3.00A
Static Baseline Drift (Cu) ±0.002A/30min
Dynamic Baseline Drift (Cu) ±0.004A/15min
Background Correction Deuterium lamp≥ 40x (1Abs), self-priming≥ 80x (1Abs)
Flame System Characteristic Concentration (Cu) ≤0.035ug/ml
Detection Limit (Cu) ≤0.004ug/ml
Repeatability (Cu) RSD ≤0.5%
Acetylene Flow Control Auto 12-Level
Air Assist Control Auto 4-Level
Burner Lift Automatic lifting
Burner Head Titanium 100mm burner
Nebulizer High efficiency glass nebulizer
Spray Chamber Corrosion-resistant material spray chamber
Safety Protection Automatically cut off gas in case of low pressure, power failure, flame out, or burner mismatched
Data Processing Measuring Method Flame method, Hydride generation-Atomic absorption method, Flame emission method
Concentration Calculation Method Standard curve method (6 linear/non-linear fitting methods), Standard addition method, Interpolation method
Repeat Measurement Times 1-30 times. Calculate and give the average value of absorbance /concentration. Standard deviation and relative standard deviation
Report Printing Parameter printing, Data result printing
Other Computer External connect
Ambient Temp 10℃-30℃
Ambient Humidity 40%-85%
Power Supply 220/110V, 50/60HZ
External Size (WxDxH)(mm) 830x650x560
Shipping Size (WxDxH)(mm) 1000x780x810
N.W./G.W. (kg) 95/115
Standard Accessory Software, Air compressor, Cu Hollow cathode lamp
Optional Accessory Computer, Printer, Hydride generator, Autosampler

Reviews

There are no reviews yet.

Be the first to review “Atomic Absorption Spectrophotometer with Double Beam”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsAtomic Absorption Spectrophotometer with Double Beam removeZenithlab (IB-9025A) Laboratory Incubator removeDiscover 14 Panel Cup with Adulterants Per Pack removeMotic BA210 Series Biomedical Microscope removePlastic Urine Container Per Pack removeDiscover 5 Panel Cup with Adulterants Per Pack remove
NameAtomic Absorption Spectrophotometer with Double Beam removeZenithlab (IB-9025A) Laboratory Incubator removeDiscover 14 Panel Cup with Adulterants Per Pack removeMotic BA210 Series Biomedical Microscope removePlastic Urine Container Per Pack removeDiscover 5 Panel Cup with Adulterants Per Pack remove
ImageDrug Test CupDrug Test Cup
SKUSF1033560130127-71SF1033560084-109SF1033560084-28SF1033560084-78SF1033560084-106SF1033560084-23
Rating
Price

$0.00

$350.00

$0.00

$0.00

$8.20

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad Model : SP-AA3618 The atomic absorption spectrophotometer is widely used in the analysis of major and trace elements in metallurgy, geology, mining, petroleum, light industry, agriculture, medicine, health, food and environmental monitoring.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Microprocessor control.
  • Digital display setting and actual temperature.
  • Over temperature alarm, PID self-tuning.
  • Digital display running timer.
  • Stainless steel interior.
  • Electricity leakage protection.
  • With glass inner door, With hidden door locks.
  • Mechanical overheat protection, cut off the heating sources.
  • Automatic alarm after operation.
  • Suitable for constant temperature tests.
  • Suitable for bacteria cultivation, breeding, ferment.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self contained and the entire cup is tamper resistant. Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock The BA210 series is a line of basic biological microscopes manufactured by Motic. The unit is equipped with Motic Infinity Optics (CCIS®, offering quality performance in the fields of education and training. The device features a coaxial coarse and fine housing with a quadruple reverse-mounted nose piece. Its contrast methods, such as phase contrast, polarization and dark field, are easily performed through optional accessories. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
  • Total Volume: 60mL.
  • Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
  • Made of premium PP material, it is durable for usage.
  • Some measurements can be used to not only use urine samples, it can also be used for other liquids.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self-contained and the entire cup is tamper resistant. Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Atomic Absorption Spectrophotometer Features:
  1. The atomic absorption spectrophotometer is quipped with a complete software and hardware system. It is highly intelligent, easy to use and simple to operate, and meets the requirements of authority management, audit tracking and other requirements.
  2. Working methods can be stored, eliminating the need to repeatedly set test conditions, streamlining the detection process, avoiding duplication of work, and greatly saving users' time and cost.
  3. Fully automatic eight-lamp position rotating lamp stand, automatic switching, free setting of work lamp/preheating lamp, automatic call of optimal analysis parameters and analysis conditions.
  4. Total reflection optical system, full-band achromatic, automatic wavelength scanning, automatic peak search.
  5. It has both deuterium lamp and self-priming background subtraction to meet the detection needs of complex matrix samples.
  6. Full titanium burner, stable combustion and fast heat balance.
  7. Reliable multiple protection systems, real-time flame monitoring, acetylene leakage monitoring and protection, real-time monitoring of abnormal pressure, and cooling water monitoring.
  8. The laughing gas-acetylene flame effectively increases the types of test elements, with a wide analysis range and strong selectivity. Test interference is small.
  9. Paired with the hydride generator produced by our company, it can expand the detection of arsenic, selenium, mercury, and antimony lamp elements, easily cope with the diversified problems of analysis samples, and meet the analysis needs of multiple elements.
  10. An atomic absorption spectrophotometer is optional and can be installed freely.
 
Atomic Absorption Spectrophotometer Specifications:
Model SP-AA3618
Optical System Optical System Double Beam
Monochromator Czerny-Turner type, focal lengths at 350mm
Grating Grating 1800 lines/mm, scintillation wavelength 250nm
Spectral Bandwidth (nm) 0.1, 0.2, 0.4, 0.7, 1.4, 2nm Automated slit selection
Wavelength Range (nm) 185-900nm
Wavelength Accuracy (nm) 0.15 nm
Wavelength Repeatability (nm) ≤0.05nm
Spectral Bandwidth Deviation ±0.02 nm
Lamp Stand 8
Element Lamp Type Cu lamp (Standard accessory) Other element lamp is optional accessory
Photometric Performance Reading Mode Transmittance, absorbance, concentration
Photometric Range 0-125%, -0.1-3.00A
Static Baseline Drift (Cu) ±0.002A/30min
Dynamic Baseline Drift (Cu) ±0.004A/15min
Background Correction Deuterium lamp≥ 40x (1Abs), self-priming≥ 80x (1Abs)
Flame System Characteristic Concentration (Cu) ≤0.035ug/ml
Detection Limit (Cu) ≤0.004ug/ml
Repeatability (Cu) RSD ≤0.5%
Acetylene Flow Control Auto 12-Level
Air Assist Control Auto 4-Level
Burner Lift Automatic lifting
Burner Head Titanium 100mm burner
Nebulizer High efficiency glass nebulizer
Spray Chamber Corrosion-resistant material spray chamber
Safety Protection Automatically cut off gas in case of low pressure, power failure, flame out, or burner mismatched
Data Processing Measuring Method Flame method, Hydride generation-Atomic absorption method, Flame emission method
Concentration Calculation Method Standard curve method (6 linear/non-linear fitting methods), Standard addition method, Interpolation method
Repeat Measurement Times 1-30 times. Calculate and give the average value of absorbance /concentration. Standard deviation and relative standard deviation
Report Printing Parameter printing, Data result printing
Other Computer External connect
Ambient Temp 10℃-30℃
Ambient Humidity 40%-85%
Power Supply 220/110V, 50/60HZ
External Size (WxDxH)(mm) 830x650x560
Shipping Size (WxDxH)(mm) 1000x780x810
N.W./G.W. (kg) 95/115
Standard Accessory Software, Air compressor, Cu Hollow cathode lamp
Optional Accessory Computer, Printer, Hydride generator, Autosampler
Features:
  • Microprocessor control.
  • Digital display setting and actual temperature.
  • Over temperature alarm, PID self-tuning.
  • Digital display running timer.
  • Stainless steel interior.
  • Electricity leakage protection.
  • With glass inner door, With hidden door locks.
  • Mechanical overheat protection, cut off the heating sources.
  • Automatic alarm after operation.
  • Suitable for constant temperature tests.
  • Suitable for bacteria cultivation, breeding, ferment.
  Technical Specification: Model: IB-9025A Working size: 250x250x250mm/9.84x9.84x9.84inch Power: 150W Temperature range: Room temperature+5~65℃ Temperature resolution: 0.1℃ Temperature fluctuation: ±0.5℃ Timer: 0-9999min Voltage: 110V 60Hz / 220V 50Hz Dimension: 380x370x580mm/14.96x14.57x22.83inch Size: 52cm*46cm*75cm / 20.5in*18.2in*29.6in Gross Weight:42kg / 93lb Net Weight: 23kg / 51lb Warranty: 1 year
All-in-One Design
FDA 510(K) & CLIA Waived Up to 99% accuracy rate Results in as little as 1 minute 24 Month Shelf Life from Date of Manufacture Secure, seal and send to lab for confirmation Built in temperature strip Available to test up to 17 substances with adulterants or 18 without adulterants Adulterants available
 
 
The BA210 series is a line of basic biological microscopes manufactured by Motic. The unit is equipped with Motic Infinity Optics (CCIS®, offering quality performance in the fields of education and training. The device features a coaxial coarse and fine housing with a quadruple reverse-mounted nose piece. Its contrast methods, such as phase contrast, polarization and dark field, are easily performed through optional accessories. Technical applications: Biomedical Type: Optical Observation technique: Dark field Magnification: 4 unit, 10 unit, 40 unit, 100 unit  
  • Total Volume: 60mL.
  • Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
  • Made of premium PP material, it is durable for usage.
  • Some measurements can be used to not only use urine samples, it can also be used for other liquids.
All-in-One Design
FDA 510K & CLIA Waived 99% Accurate Results in as little as 1 minute 24 Month Shelf Life from Date of Manufacture Secure, seal and send to lab for confirmation Built in temperature strip Available to test up to 14 substances Adulterants available
 
 
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare