New

Auto Lensmeter D-910

$0.00

Shipped From Abroad

An auto lensmeter D-910 measures the prescription of eyeglass lenses. It determines sphere, cylinder, axis, prism and distance between each optical center (pupillary distance). The lensometer is also used to accurately mount lenses into their frames as well as for orienting and marking lenses prior to cutting the lenses.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Brands:: zbxyoptics

Description

The Auto Lensmeter D-910 is a high-precision, fast, and versatile lens measuring device. It captures sphere, cylinder, axis, prism, PD, PH, and PCL in just 0.1 seconds. With a capacitive touchscreen, multi-wavelength detection, and multiple connectivity options, it ensures reliability, accuracy, and efficiency in optical practices.

Features
  • Measures sphere, cylinder, axis, prism, pupillary distance (PD), pupillary height (PH), and progressive channel length (PCL).

  • High-resolution capacitive touch panel for easy operation.

  • Simultaneous multi-wavelength measurement for advanced accuracy.

  • Four connectivity modes: Bluetooth, RS-232, USB, and Wi-Fi.

  • Stable magnetic sliding nosepiece and refined lens holder.

  • Fast measurement speed of approximately 0.1 seconds.

Benefits of Auto Lensmeter D-910
  • Precision
    Auto lensmeter D-910 uses advanced technologies to provide precise and reliable refraction measurements, reducing the risk of human error.
  • Speed

Auto lensmeter D-910 can quickly and efficiently measure lens power, allowing eye care professionals to see more patients in less time.

  • Versatility

Auto lensmeter D-910 can be used for a variety of measurements, including pupillary distance measurement, optical center height, automatic measurement taking, etc., offering great versatility for eye care professionals.

  • Complete optical measurements in one device, suitable for all lens types.

  • User-friendly touchscreen ensures fast, intuitive operation.

  • Multi-wavelength analysis enhances accuracy for coated and treated lenses.

  • Flexible connectivity options streamline data sharing and workflow.

  • Robust design with improved marking and lens holding for consistent results.

  • Ultra-fast readings improve patient flow and clinic efficiency.

Technical Specifications

Measurement Capabilities

  • Sphere: ±25 D (steps: 0.01 / 0.12 / 0.25 D)

  • Cylinder: ±9.99 D (steps: 0.01 / 0.12 / 0.25 D)

  • Axis: 0°–180° (1° increments)

  • Addition (Add): ±9.99 D

  • Prism: Up to 15 D (steps: 0.01 / 0.12 / 0.25 D)

  • Pupillary Distance (PD): 40–90 mm, 0.5 mm increments

  • Lens Diameter Range: 12–112 mm

  • Measurement Speed: Approx. 0.1 seconds per lens

  • Abbe Number: 30–60

Display & User Interface

  • 7-inch TFT LCD capacitive touchscreen

  • Automatic recognition of single-vision, progressive, and contact lenses

Connectivity & Printing

  • Communication: Bluetooth, RS-232, USB, Wi-Fi

  • Built-in thermal printer

Physical & Electrical Specifications

  • Dimensions: 180 × 255 × 455 mm

  • Packaging Size: 620 × 390 × 390 mm

  • Weight: Approx. 12 kg

  • Power Supply: AC 100–240 V, 50/60 Hz, approx. 25 VA

Reviews

There are no reviews yet.

Be the first to review “Auto Lensmeter D-910”

Your email address will not be published. Required fields are marked *

Quick Comparison

Auto Lensmeter D-910 removeAutomatic Computer Goldmann (Visual Field Analyzer) removeEar Irrigation and acumen removal removeApplanation Tonometer removeAuto Refractometer removePortable Rebound Tonometer remove
NameAuto Lensmeter D-910 removeAutomatic Computer Goldmann (Visual Field Analyzer) removeEar Irrigation and acumen removal removeApplanation Tonometer removeAuto Refractometer removePortable Rebound Tonometer remove
ImageMecan Applanation Tonometer YZ30XMecan RM-9000 Auto RefractometerMecan SW-500 Portable Rebound Tonometer
SKUSF103356013013SF103356013012SF1033560107-1SF1033560107-14SF1033560107-17
Rating
Price

$0.00

$3,850.00

$0.00

$0.00

$2,035.00

$1,815.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad An auto lensmeter D-910 measures the prescription of eyeglass lenses. It determines sphere, cylinder, axis, prism and distance between each optical center (pupillary distance). The lensometer is also used to accurately mount lenses into their frames as well as for orienting and marking lenses prior to cutting the lenses.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock
Features: The Bio-1000 automated perimeter absorbs the advantages of international advanced perimetry devices. It comprises the highly integrated computer, optics, machinery and electronics systems.   Delivery & Availability: Typically 7-14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock
Features: ●Professional Same ear wax removal tool as those used by doctors, you can easily eliminate ear wax buildup at home, really save your money and time on medical visiting. Safe and Environmentally Friendly. ●Quick & Easy This ear wax removal kit is a quick, effective treatment for excess ear wax buildup. Fill the bottle with solution, Twist on the disposable tip, Use the trigger handle to spray solution into the ear canal. So Easy.   Delivery & Availability: Typically 7-14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from abroad The product is designed on the principle basis of Goldman tonometer. It can be connected with slit lamp(Carl Zeiss type).
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Shipped from abroad
  • Light rack with integral casting, CNC machining, the measuring system is more stable, good consistency.
  • Color LCD display, 5.7 inches man-machine interface is more comfortable.
  • PD automatic measurement function, automatically PD value.
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Shipped from abroad Tonometer SW-500 with vertical and horizontal two working modes, wireless output print data.
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
ContentThe Auto Lensmeter D-910 is a high-precision, fast, and versatile lens measuring device. It captures sphere, cylinder, axis, prism, PD, PH, and PCL in just 0.1 seconds. With a capacitive touchscreen, multi-wavelength detection, and multiple connectivity options, it ensures reliability, accuracy, and efficiency in optical practices.
Features
  • Measures sphere, cylinder, axis, prism, pupillary distance (PD), pupillary height (PH), and progressive channel length (PCL).

  • High-resolution capacitive touch panel for easy operation.

  • Simultaneous multi-wavelength measurement for advanced accuracy.

  • Four connectivity modes: Bluetooth, RS-232, USB, and Wi-Fi.

  • Stable magnetic sliding nosepiece and refined lens holder.

  • Fast measurement speed of approximately 0.1 seconds.

Benefits of Auto Lensmeter D-910
  • Precision Auto lensmeter D-910 uses advanced technologies to provide precise and reliable refraction measurements, reducing the risk of human error.
  • Speed
Auto lensmeter D-910 can quickly and efficiently measure lens power, allowing eye care professionals to see more patients in less time.
  • Versatility
Auto lensmeter D-910 can be used for a variety of measurements, including pupillary distance measurement, optical center height, automatic measurement taking, etc., offering great versatility for eye care professionals.
  • Complete optical measurements in one device, suitable for all lens types.

  • User-friendly touchscreen ensures fast, intuitive operation.

  • Multi-wavelength analysis enhances accuracy for coated and treated lenses.

  • Flexible connectivity options streamline data sharing and workflow.

  • Robust design with improved marking and lens holding for consistent results.

  • Ultra-fast readings improve patient flow and clinic efficiency.

Technical Specifications

Measurement Capabilities

  • Sphere: ±25 D (steps: 0.01 / 0.12 / 0.25 D)

  • Cylinder: ±9.99 D (steps: 0.01 / 0.12 / 0.25 D)

  • Axis: 0°–180° (1° increments)

  • Addition (Add): ±9.99 D

  • Prism: Up to 15 D (steps: 0.01 / 0.12 / 0.25 D)

  • Pupillary Distance (PD): 40–90 mm, 0.5 mm increments

  • Lens Diameter Range: 12–112 mm

  • Measurement Speed: Approx. 0.1 seconds per lens

  • Abbe Number: 30–60

Display & User Interface

  • 7-inch TFT LCD capacitive touchscreen

  • Automatic recognition of single-vision, progressive, and contact lenses

Connectivity & Printing

  • Communication: Bluetooth, RS-232, USB, Wi-Fi

  • Built-in thermal printer

Physical & Electrical Specifications

  • Dimensions: 180 × 255 × 455 mm

  • Packaging Size: 620 × 390 × 390 mm

  • Weight: Approx. 12 kg

  • Power Supply: AC 100–240 V, 50/60 Hz, approx. 25 VA

The Bio-1000 automated perimeter absorbs the advantages of international advanced perimetry devices. It comprises the highly integrated computer, optics, machinery and electronics systems. Incorporated with the advanced configuration, comprehensive software inspection categories, and strictly in accordance with international Goldman standard, it provide scientific means for glaucoma, fundus disease, visual pathway injury and neurological diseases. Feature:         * Comprehensive real-time monitoring,Heiji-krakau physiological blind spot monitoring,gaze tracking/head position tracking,automatic measurement of pupil diameter, reduce the impact of pupil effect on visual field detection. * Personalized design,accurate clinical analysis,accurate and repid examination strategy. * Under international Goldman standard,providing a variety of classic test procedures and report analysis. Technical Specification:
Inspection range 90°
Inspection distance 30cm
Background light brightness White 31.5abs
Visual target brightness 1abs --- 10000abs
Visual target size Goldmann III
Visual target interval time 200ms
Visual target interval time Stardard or adjustment according to patient reflection
Threshold test model Center5°- 16°,center10°- 68, 24-2, 30-2, 30°- 60°,nasal step
Upper threshold test model 30°-40,30°-76,P-60,60°-81,60°-120,190°-135,nasal side
Special detection strategy Esterman monocular,Esterman binocular,user-customized test,150°driver monocular fast detection, 150°driver monocular standard detection, upper36°detection, blind spot detection, 150° horizontal straightness detection
Pupil size test Automatic
Fixation monitoring Blind spot monitoring, eye position deviation alarm, eyedeviation curve
Enviroment light detection Automatic
Analysis software Reliability analysis,single vision report,triple visionreport,GPA half vision analysis, GPA glaucoma developing analysis, VFI vision index analysis
Operation system Win7 above
 
Click Here To Download Catalogue
Features: ●Professional Same ear wax removal tool as those used by doctors, you can easily eliminate ear wax buildup at home, really save your money and time on medical visiting. Safe and Environmentally Friendly. ●Quick & Easy This ear wax removal kit is a quick, effective treatment for excess ear wax buildup. Fill the bottle with solution, Twist on the disposable tip, Use the trigger handle to spray solution into the ear canal. So Easy. ●Standard Capacity of the ear cleaner solution bottle is 10.6Oz, it has the most suitable size to hold in hand. Working at condition 32-122℉(0-50℃). Recommend to fill 1/5 of the bottle with OTC hydrogen peroxide, and 4/5 with very warm water. ●Complete Ear Washer System Our earwax removal kit comes with 1× Ear Washer Bottle, 1× Wash Basin, 1× Rubber Bulb, 1× Short Injection Head, 1× Long Hose Injection Head, 5× Disposable Tip, 1× User Manual.Applanation Tonometer is designed on the principle basis of Goldman tonometer. It can be connected with slit lamp(Carl Zeiss type). Features of Applanation Tonometer:
  • When used with slit lamp, it can be used to examine the eyes and measure ocular pressure.
  • Accurate measurement and total tolerance are less than 0.066KPa(0.55Hg).
  • Directly get the ocular pressure and do not need to look up the conversion table.
  • The measured ocular pressure is not affected by hardness of eye.
  • The affected?ocular volume is just 0.56 cubic millimeter.
  • Adjustable measuring pressure ensures the long-term stability and reliability.
Technical Specifications Applanation Tonometer:
  • Measuring Range: 0~1064 Kpa
  • Light Ring Displacement: 1.53×2=3.06mm
  • Diameter of Prism Head: 7mm
  • Moving Range of Prism Head: 3mm
Features:
  • Using the ARM processor and the latest domestic image processing, the system is fast and the image is clear.
  • Japan’s mature optical path system, humanized automatic mist measurement process, to reduce the error caused by adjustment, more precise measurements.
  • Light rack with integral casting, CNC machining, the measuring system is more stable, good consistency.
  • Color LCD display, 5.7 inches man-machine interface is more comfortable.
  • PD automatic measurement function, automatically PD value.
  • One key lock function, quickly locking mobile platforms.
  • Innovative designs, according to the structure of human body engineering, to bring customers good aesthetic feeling and comfortable.
  • Data transmission with CV7200, improved efficiency of online 5x magnification options, respond to different viewing needs.
  Technical Specifications: Measurement Range Vertex distance.......................................0.0,12.0,13.75,15mm Sphere.......................................-20D~+20D(0.12/0.25D step) Cylinder...........................................0~±10D(0.12/0.25D step) Axis...............................................................1~180°(1° step) PD distance............................................................30~85mm PD..........................................................................10~86mm Minimum pupil diameter..............................................Ø2.0mm Target................................................automatic fogging target Hardware specifications Monitor.............................................................5.7" color LCD Printer......................................................Fast thermal printer Power saving function....................OFF, 5/15 mins (selectable) Power supply................................AC110~220V, 60/50Hz, 50W Dimension/weight..............................288x500x480mm(14kgs)
Tonometer SW-500 with vertical and horizontal two working modes, wireless output print data. The equipment is used to measure intraocular pressure, using the principle of:  the probe hits the surfaces of different hardness at a certain speed, has a different reaction when the probe rebounds. Be of advantages of high accuracy, portable, without anesthesia, without the cross-infection, etc. Features:
  • Measurement can go along both in standing and lying posture
  • Wireless data printing
  • Easy to learn, easy to use
  • Lightweight and handy
  • No anesthesia, avoiding discomfort reaction
Technical Specifications:
Performance Index:
Measuring Range : 3mmHg~70mmHg
Measuring Error: ±1.5mmHg(3mmHg≤intraocular pressure≤25mmHg)
±2.5mmHg(25mmHg<intraocular pressure≤70mmHg)
Environment Requirement:
Transport and Storage: Ambient temperature:-20℃~+55℃
Relative moisture:≦95%
Atmosphere pressure:500hPa~1060hPa
Running: Ambient temperature:+5℃~+40℃
Relative moisture:≦80%
Atmosphere pressure:700hPa~1060hPa
Rating voltage: DC3V(2 AA Batteries)
Rating input power:1VA
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar