Auto Lensmeter JD-2000

$0.00

Shipped From Abroad

JD-2000 Auto Lensmeter delivers fast, precise lens measurements with LCD display, automatic recognition, and user-friendly operation for eye care professionals.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Brands:: zbxyoptics

Description

The JD-2000 Auto Lensmeter is a precise and user-friendly device designed for quick and accurate measurement of optical lenses. It supports single vision, progressive, and contact lens measurements, offering reliability in both clinical and optical shop settings. With its advanced technology, clear LCD display, and fast processing speed, the JD-2000 ensures efficient workflow and dependable results.

Key Features
  • Automatic measurement of single, progressive, and contact lenses

  • High-precision sphere, cylinder, axis, and prism measurements

  • Easy-to-read LCD display for enhanced visibility

  • Fast measurement response for increased efficiency

  • Compact and ergonomic design for convenience

  • Suitable for optical shops, clinics, and laboratories

Technical Specifications
Range of measurement
Sphere 0~±25m-1 0.01/0.12/0.25m-1 step
Cylinder 0~±9.99m-1 0.01/0.12/0.25m-1 step
Axis 0°~180° (1°step)
Add. 0~+9.99m-1 0.01/0.12/0.25m-1 step
Prism degree 0~15m-1 0.01/0.12/0.25m-1 step
Measurement mode
Cylinder +,+/-,-
Prism X-Y, P-B
Contact lens Soft/hard lens
Measuring mode Single/progressive/ automatic recognition
Specifications
Diameter of lens Φ20~Φ108mm
PD 40~90mm, 0.5mm step
Speed of measurement 0.1second
Display 7″LCD/TFT
Printer Thermal printer
Dimension 196mm*286mm*442mm
Weight ~6kg
Power supply 100~240V 50~60Hz

Reviews

There are no reviews yet.

Be the first to review “Auto Lensmeter JD-2000”

Your email address will not be published. Required fields are marked *

Quick Comparison

Auto Lensmeter JD-2000 removeView Tester (Manual Phoropter) removeTonometer removeManual lensmeter removeENT/Neurosurgery Operating Microscope removePortable Rebound Tonometer remove
NameAuto Lensmeter JD-2000 removeView Tester (Manual Phoropter) removeTonometer removeManual lensmeter removeENT/Neurosurgery Operating Microscope removePortable Rebound Tonometer remove
ImageMecan VT-8 View Tester (Manual Phoropter)Mecan Tonometer YZ7AMecan Manual lensmeter NJC-4Mecan SW-500 Portable Rebound Tonometer
SKUSF1033560107-26SF1033560107-9SF1033560107-22SF1033560109-1SF1033560107-17
Rating
Price

$0.00

$858.00

$220.00

$0.00

$0.00

$1,815.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad JD-2000 Auto Lensmeter delivers fast, precise lens measurements with LCD display, automatic recognition, and user-friendly operation for eye care professionals.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Ship from abroad
  • Equipped with comprehensive measuring functions, it provides SPH, CYL, AXIS and pupil distance optometry
  • Durable and easy to operate
  • Easily and intuitively read the sphere focal scale value
  • High eco-friendly materials
  • Design fitting the face curve and no stimulation
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Shipped from abroad This product is used to measure the intraocular pressure (IOP) by measuring the depth produced on the surface of the cornea by a load of a known weight. Each division on the scale corresponds to 1/20mm corneal depth.
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Shipped from abroad The NJC-4 Lensmeter is used to measure the diopters of spherical lens and cylinder lens, the axis of cylinder lens, the strength and the baseline direction of shuttle lens, it can also stamp the optical center of lens, the axis of cylinder len and the base direction of shuttle lens.
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Shipped from abroad
Delivery & Availability: Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.

Corder Microscope has Fluid, Responsive and Accurate.

Fluid. Responsive. Accurate. These were a few of the principles guiding every phase in the design of the Corder Microscope. With the choicest mechanical machined components, the Corder Microscope has the grace and agility to adjust to every desired position on command. Well designed Apochromatic optics treated with Corder's Mcoatings produce true-to life sharp images with high depth, definition and contrast.
Shipped from abroad Tonometer SW-500 with vertical and horizontal two working modes, wireless output print data.
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
ContentThe JD-2000 Auto Lensmeter is a precise and user-friendly device designed for quick and accurate measurement of optical lenses. It supports single vision, progressive, and contact lens measurements, offering reliability in both clinical and optical shop settings. With its advanced technology, clear LCD display, and fast processing speed, the JD-2000 ensures efficient workflow and dependable results.
Key Features
  • Automatic measurement of single, progressive, and contact lenses

  • High-precision sphere, cylinder, axis, and prism measurements

  • Easy-to-read LCD display for enhanced visibility

  • Fast measurement response for increased efficiency

  • Compact and ergonomic design for convenience

  • Suitable for optical shops, clinics, and laboratories

Technical Specifications
Range of measurement
Sphere 0~±25m-1 0.01/0.12/0.25m-1 step
Cylinder 0~±9.99m-1 0.01/0.12/0.25m-1 step
Axis 0°~180° (1°step)
Add. 0~+9.99m-1 0.01/0.12/0.25m-1 step
Prism degree 0~15m-1 0.01/0.12/0.25m-1 step
Measurement mode
Cylinder +,+/-,-
Prism X-Y, P-B
Contact lens Soft/hard lens
Measuring mode Single/progressive/ automatic recognition
Specifications
Diameter of lens Φ20~Φ108mm
PD 40~90mm, 0.5mm step
Speed of measurement 0.1second
Display 7″LCD/TFT
Printer Thermal printer
Dimension 196mm*286mm*442mm
Weight ~6kg
Power supply 100~240V 50~60Hz
Features:
  • Equipped with comprehensive measuring functions, it provides SPH, CYL, AXIS and pupil distance optometry
  • Durable and easy to operate
  • Easily and intuitively read the sphere focal scale value
  • High eco-friendly materials
  • Design fitting the face curve and no stimulation
  • Easy to take and clean
  • Free switch between the cross-cylindrical lens and the rotary prism
  • When the rotating risk is turning by the sphere, it can make sphere power adjust 3.00D for big scope.
  • It is designed expediently and smartly for a particular cross cylinder. Supporting supplementary lens could increase scope of measurement.
Technical Specifications:
Sphere
Range:-19.00~+16.75m-1 Step: 0.25m-1, 3.00m-1
Cylinder
Range: 0.00~-6.00m-1(Measuring Range With Accessories0.00~-8.00m-1) Step: 0.25m-1
Cylinder Axis
Range: 0~180°, Step:5°
Distance of Optical center (also known as Pupil)
Range: 50~75mmStep: 1mm
Sight Switch
Range:∞~380mm (distance of Optical center is64mm)
Front Chin Test
Range: 0~16mm
Distance (from cornea vertex to the lens surface)
16mm
Standard Accessories Lens
two pieces of Auxiliary Cylinder -2.00m-1 and -0.12m-1 respectively
Standard Accessories
one piece of M2 Hexagon wrench , one piece of a Myopia Standard Card, two piece of Myopia Standard Card , one piece of standard card holder , a dust cover
Auxiliary Lens
“O”:Open aperture “R”:Retinoscope lens “R”:Retinoscope lens “R”:Retinoscope lens *Lens of +1.50m-1 ,It is suit for the distance of 67 centimeters “P”:Polaroid * it is used for examining the dioptric balance of eyes , Implicit strabismus and stereo vision “RMV”:Red Vertical maddox *Be used to examine Implicit strabismus “RMH”:Red horizontal maddox *Be used to examine Implicit strabismus “WMV”:Plane Vertical Maddox *Be used to examine Implicit strabismus “WMH”:Plane horizontal maddox *Be used to examine Implicit strabismus “RL”:Red lens *Be used to examine eye function, Blending function and Implicit strabismus “GL”:Green lens *Be used to examine eye function, Blending function and Implicit strabismus “+”:Test mark of optical center adjustment “+.12”:Dioptric of the Spherical Lens is +0.12m-1 *Be used for the semi-adjustment of sphere lens, 0.25m-1 “PH”:1mmPinhole lens *Be used to exclude visual non-refractive errors of the tested eye “6ΔU”:6ΔBottom-up prism *Be used to examine the rotating prism with the detection of nearly horizontal squint “10ΔI”:10ΔBottom-up prism *Be used to examine the rotating prism with the detection of nearly horizontal squint “±0.50”:Cross-cylindrical lens *Be used to examine the corrected dioptric of the Presbyopia and spherical lens “OC”:Black lens
size
338(L)×99(W)×292(H)mm
NW
about 5kg
This product is used to measure the intraocular pressure (IOP) by measuring the depth produced on the surface of the cornea by a load of a known weight. Each division on the scale corresponds to 1/20mm corneal depth. Features:
  • Schiotz type
  • All the parts that contact the cornea are made of stainless steel and are anti-acid, which does no harm to issues
  • The instrument is safe, reliable, accurate, and convenient to carry
The NJC-4 Lensmeter is used to measure the diopters of the spherical lens and cylinder lens, the axis of cylinder lens, the strength and the baseline direction of shuttle lens, it can also stamp the optical center of the lens, the axis of cylinder lens, and the base direction of shuttle lens. This instrument (Both Ac and Dc are permitted Two cells When Dc) has clear readings and graduations as well as high objective precision and reliabilities except that it can be operated easily and conveniently, AU the lenses and the made glasses can be measured by it, therefore, it is a required and ideal measuring instrument for glasses manufactures, glasses stores and ophthalmological hospitals. Technical Specifications:
  • Eyepiece focusing range: ±5D
  • The top point diopter measuring range: 0—±20D
  • The minimum measuring square value: 0.125D
  • The shuttle lens measuring range: 5A
  • The shuttle lens square value: 1A
  • The cylinder lens axial range: 0—180°
  • The cylinder lens axial square value: 5°
  • The maximum diameter of the measured lenses l00m/m
  • Power supply: AC 110V-6V DC 3V
  • Note: This item is AC 110V; The battery is not included!
 

Features:

Corder Microscope has Fluid, Responsive and Accurate.

Fluid. Responsive. Accurate. These were a few of the principles guiding every phase in the design of the Corder Microscope. With the choicest mechanical machined components, the Corder Microscope has the grace and agility to adjust to every desired position on command. Well designed Apochromatic optics treated with Corder's Mcoatings produce true-to life sharp images with high depth, definition and contrast. More comfortable operation Tiltable binocular tubes available, which can incline more than 60° depending on the posture and physique of the operating surgeon. Movable range: 30° (straight) to 90° (inclined) Corder microscope configured with XYZ motorized movement operated through a comfortable foot /Handle control, a veryeffective co-axial illumnation and 50W halogen light source makes it ideal for Neuro surgeries.

Doctor-patient communication is easier

To address digital documentation needs, a host of digital SLR, video camera, and CCD adapters are made available with the ProLine in addition to Corder's proprietary iVu multi-functional imaging solution. 1080P full hd image quality, efficient image management during the operation. Integrate your digital workflow to facilitate case management and facilitate more intuitive patient communication.   Technical Permeants: Magnification: motorized zoom system, 1:6 zoom ratio, magnification 3x~16x Focusing range: 50mm Binocular tube: 30°~90° tiltable tube ,(0° ~200° optional) Eyepiece: 12.5x / 10x Objective lens: F 300mm(175mm, 250mm, 350mm optional) pupil distance: 55mm~75mm diopter adjustment: +6D ~ -6D Field of view: Φ74~Φ12mm X-Y translator: Motorized by foot switch or handle controller, ±30mm Assistant tube: 360° Rotating assistant tube Reset functions: YES   Illumination System: Coaxial illumination Light source: Halogen lamp Light intensity adjustment: Continuous brightness adjustment 0-100000lux Fiber optic illumination: Dual fiber Field of illumination: Φ50mm Filter: Red free filter, small spot   Accessories CCD Camera system: Beam splitter, CCD adapter, CCD, Display XENON LAMP: 150000lux Integrated Video Adapter: SONY / CANON Camera
Click Here To Download Catalogue
Tonometer SW-500 with vertical and horizontal two working modes, wireless output print data. The equipment is used to measure intraocular pressure, using the principle of:  the probe hits the surfaces of different hardness at a certain speed, has a different reaction when the probe rebounds. Be of advantages of high accuracy, portable, without anesthesia, without the cross-infection, etc. Features:
  • Measurement can go along both in standing and lying posture
  • Wireless data printing
  • Easy to learn, easy to use
  • Lightweight and handy
  • No anesthesia, avoiding discomfort reaction
Technical Specifications:
Performance Index:
Measuring Range : 3mmHg~70mmHg
Measuring Error: ±1.5mmHg(3mmHg≤intraocular pressure≤25mmHg)
±2.5mmHg(25mmHg<intraocular pressure≤70mmHg)
Environment Requirement:
Transport and Storage: Ambient temperature:-20℃~+55℃
Relative moisture:≦95%
Atmosphere pressure:500hPa~1060hPa
Running: Ambient temperature:+5℃~+40℃
Relative moisture:≦80%
Atmosphere pressure:700hPa~1060hPa
Rating voltage: DC3V(2 AA Batteries)
Rating input power:1VA
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare