AVE-766 Urine Formed Elements Analyzer
$0.00
Shipped From Abroad
The AVE-766 Urine Formed Elements Analyzer automates the quantitative analysis of urine sediment, delivering precise results in under 4 minutes. Featuring advanced digital imaging and AI algorithms, this compact, user‑friendly device is ideal for modern clinical laboratories and point‑of‑care diagnostics.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
Parameters Detected
- All types of Urine Formed Elements are classified and counted, with automatic erythrocytes morphological analysis available and real images and statistical diagrams displayable and printable;
- It is connectable to Automatic Urine Analyzers and a comprehensive report is generated;
- Urine physical indexes are reportable;
- Extensible tests of Hydrothoax, Cerebrospinal Fluid etc. can be don as well.
Work Principle
Use automated morphological microscopy technology to capture real images of urine formed elements, and then locate and track, recognize, classify and count them
Product Features
- Made strictly according to ISLH Recommended Reference Procedure for the Enumeration of Particles in Urine;
- Double microscope works simultaneously to improve throughput sharply up to 200 tests / hour;
- Un-centrifuged urine samples at cutoff concentration level of 3-5cell/µl are detectable;
- Automatic sampling system with liquid level detection;
- Automatic recognition, classification and quantitation of urine formed elements;
- Precise erythrocytes morphological analysis helps to determine the source of hematuria;
- Real whole view-field microscopic images of urine formed elements are presented;
- Automatic notice of verification and on-screen verification, no additional microscopic review needed;
- Characteristic parameters of urine formed elements are available for further clinical research;
- Standardized and confirmatory analysis report with both images and diagrams available;
- Self-learning ability continuously improves the recognition accuracy;
- Unique morphological quality control available;
- Unidirectional or bidirectional interface with LIS/HIS;
- Software and language upgrades by USB stick;
- Combinable with automatic urine analyzers.
Technical Parameters
- Auto-detected Urine Formed Elements: Normal red blood cells (NRBC), Abnormal red blood cells (ARBC), White blood cells (WBC), Casts (CAST), Epithelial cells( EPI), Yeast (YST), Crystals (CRYS), Mucus (MUC) and Bacteria (BAC). Further sub-classification is available with manual on-screen verification!
- Magnification: Standard 10X & 40X images
- Memory: Min. 200,000 results (including all images captured)
- Min. Sample volume: 2.0 ml
- Sample level detection: Yes
- Max. Sample loading number: 6 racks of 10 tubes
- Throughput: Up to 200 tests / hour
- Built-in Barcode reader: Yes
- Printer: Laser, external, optional
- Interfaces: USB, RS232, LAN
- Dimensions (main unit): 825 x 650 x 545mm (L x D x H)
- Weight (main unit): 79kg
- Power (main unit): 100-240V~50/60Hz, 450VA
Additional information
Weight | 79 kg |
---|---|
Dimensions | 82.5 × 65 × 54.5 cm |
Quick Comparison
Settings | AVE-766 Urine Formed Elements Analyzer remove | AGD Erma EL-120 ELectrolyte Analyzer remove | Skyla HB1 POC Clinical Chemistry Auto Analyzer remove | ApexBio HemoSmart Gold Hemoglobin Meter remove | Hawksley 1400 Haematocrit Centrifuge remove | Skyla Hi POC Clinical Chemistry Analyzer remove | ||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | AVE-766 Urine Formed Elements Analyzer remove | AGD Erma EL-120 ELectrolyte Analyzer remove | Skyla HB1 POC Clinical Chemistry Auto Analyzer remove | ApexBio HemoSmart Gold Hemoglobin Meter remove | Hawksley 1400 Haematocrit Centrifuge remove | Skyla Hi POC Clinical Chemistry Analyzer remove | ||||||||||||||||||||||||||||
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||||||||||||||||||||||||
SKU | SF1033560130181-10 | SF1033560084-125 | SF1033560060-1 | SF1033560084-29 | SF1033560084-118 | SF1033560060-2 | ||||||||||||||||||||||||||||
Rating | ||||||||||||||||||||||||||||||||||
Price |
| $1,320.00 |
| $55.00 | $690.00 |
| ||||||||||||||||||||||||||||
Stock | ||||||||||||||||||||||||||||||||||
Availability | ||||||||||||||||||||||||||||||||||
Add to cart | ||||||||||||||||||||||||||||||||||
Description | Shipped From Abroad
The AVE-766 Urine Formed Elements Analyzer automates the quantitative analysis of urine sediment, delivering precise results in under 4 minutes. Featuring advanced digital imaging and AI algorithms, this compact, user‑friendly device is ideal for modern clinical laboratories and point‑of‑care diagnostics.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
| Shipped from Abroad The skyla HB1 Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. The portable design of the clinical chemistry analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In Stock
HemoSmart GOLD offers a fast and easy way to measure hemoglobin level and is the first biosensor-based palm sized hemoglobin testing system in the world.The one of its kind strip-based testing method offers ease of use and portability and requires only 1μL of blood.
Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
| Shipped from Abroad The skyla Hi POC Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results.The use of skyla Hi in the management of diabetes enables better access to testing and rapid clinical decision making, discussion,and implementation of optimized treatment. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | ||||||||||||||||||||||||||||
Content | Parameters Detected
Work PrincipleUse automated morphological microscopy technology to capture real images of urine formed elements, and then locate and track, recognize, classify and count themProduct Features
Technical Parameters
| Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface.
Features:
Click Here To Download Catalogue | Skyla HB1 Clinical Chemistry Analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. HB1 provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. Only needs 200µl of blood (whole blood, serum or plasma is accepted.) and no sample preparation is required. All steps are designed automatically from checking the validity of reagent discs and cartridges to printing the results. Over 30 test parameters are allowed with fast analysis and results in 15 minutes. Internal Quality Control (IQC) with self-calibration of optical system, chemicals stability and interference alerts functions monitor and ensure the results with high accuracy.
Available Test Panels
Click Here To Download Catalogue | HemoSmart GOLD offers a fast and easy way to measure hemoglobin level and is the first biosensor-based palm sized hemoglobin testing system in the world.The one of its kind strip-based testing method offers ease of use and portability and requires only 1μL of blood.
Feature
Click Here To Download Catalogue | The Hawksley Haematospin 1400 Centrifuges are built in the UK and are made from durable and high-quality components. These centrifuges are ideal for veterinary laboratories and practices specifically designed to produce reliable and accurate results on blood and urine. One of the main features of this centrifuge is that it takes both 2ml microtubes and 75mm microhaematocrits. The classic design of these centrifuges is used worldwide with guaranteed support for all servicing and parts.
Technical specifications:
Click Here To Download Catalogue | skyla Hi Analyzer enables better access to testing and rapid clinical decision making, discussion, and implementation of optimized treatment. To get the result, only prepare <1 μl fingertips blood or venous blood (depends on test item) without pretreatment with easy steps and then read the result after 6 mins. The device allows two specimens be tested in one run and provides fully automatic procedures from checking the validity of cartridge to printing the results.
Reagent Kit
Main SpecificationPrinciple
Turbidimetric Method / Biochemistry
Device
Testing Time
5~20 minutes (depends on test items)
Display and Interface
5″ TFT color touch screen LCD
Memory Capacity
50,000 test results
Dimension of Analyzer
270 x 188 x 148 mm
Weight of Analyzer
1.7 kg
Dimension of Printer Module
134 x 100 x 82.7 mm
Weight of Printer Module
0.37 kg
Power Supply
100~240 volts AC, 50-60Hz
Data Transmission
USB 2.0*4 / USB 3.0*1 / RS232*1 / RJ45*1 / Wi-Fi (optional)
Reagent and SamplesSamples
Fingertips blood or venous blood
Samples Volume
0.8 ~ 30 μL (depends on test item)
Storage Temperature (Reagent)
2 ~ 8˚C
HumidityRelative humidity < 95% (Non-condensing)
| ||||||||||||||||||||||||||||
Weight | 79 kg | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||
Dimensions | 82.5 × 65 × 54.5 cm | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||