Benchtop Conductivity Meter CON-B11

$0.00

Shipped From Abroad

Model : CON-B11

The CON-B11 benchtop conductivity meter is suitable for routine conductivity, TDS and salinity testing of laboratory samples and provides the essential features required at an affordable price.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130127-123
Brands:: Scitek

Description

Benchtop Conductivity Meter Features:
  1. 7-inch colored capacitive touch screen with high resolution (1024×600) and sensitivity.
  2. Built-in microprocessor chip has Intelligent functions such as automatic calibration, ATC, data storage, clock display, USB output, function settings, wireless printing, and self-diagnosis information,  etc.
  3. It supports wireless bluetooth printing. Real-time data transfer to mobile phone via bluetooth is optional.
  4. Smart electrode status display to ensure accurate use.
  5. Adopt advanced conductivity measurement technology, with conductivity electrode (K=1), it can meet measuring accuracy requirement for range of 0.5μS/cm ~ 200mS/cm.
  6. Ability to switch among conductivity, TDS, salinity and resistivity. Multinomial calculation for TDS and salinity to ensure the conversion precision of the full range.
  7. With ATC conductivity electrode , Its measurement result is fast and precise.
  8. Auto recognition of 8 conductivity standard solution with 2 kinds of options: Europe & USA, and China.
  9. Can store 2000 sets of test data, which can be saved and transferred to USB memory stick and opened with Excel.

 

Benchtop Conductivity Meter Specifications:
Model CON-B11
Conductivity Measuring Range Conductivity:
(0.00~20.00)μS/cm
(20.0~200.0)μS/cm
(200~2000)μS/cm
(2.00~20.00)mS/cm
(20.0~200.0)mS/cm
TDS: (0 ~ 100)g/L
Salinity: (0 ~ 100)ppt
Resistivity: (0 ~ 100)MΩ·cm
Resolution 0.01/0.1/1μS/cm; 0.01/0.1mS/cm
Accuracy Electrode: ±1.0% FS, Meter: ±1.5% FS
Temp. compensation Range (0 ~ 50)℃, auto
Electrode Constant 0.1 / 1 / 10 cm-1
Reference Temp. 25℃, 20℃, 18℃
Temperature Range (-10 ~ 110)℃
Resolution 0.1℃
Accuracy 5 ~ 60℃: ±0.5℃; Others: ±1.0℃
Other Parameters Display 7-inch colored capacitive touch screen
Data Storage 1000 sets
Power 12V (110-220, 50-60Hz adapter)
Communication Interface USB, RS232, Bluetooth
Size & Weight 240×170×70mm/600g
Working Conditions Temperature 5 ~ 35 ℃
Humidity ≤80%
IP grade IP54
Meter Kits 1) Conductivity meter
2) Electrode holder
3) Two-in-one electrode that consists of Platinum black electrode (K=1) and temperature probe.
4) Power adapter
External Size 215x170x40mm
Shipping Size 475x430x75mm
Net /Gross Weight (kg) 0.6/3

Reviews

There are no reviews yet.

Be the first to review “Benchtop Conductivity Meter CON-B11”

Your email address will not be published. Required fields are marked *

Quick Comparison

Benchtop Conductivity Meter CON-B11 removeHawksley 1400 Haematocrit Centrifuge removeAGD Erma EL-120 ELectrolyte Analyzer removePlastic Urine Container Per Pack removeSkyla Hi POC Clinical Chemistry Analyzer removeTest Strip for ApexBio HemoSmart Gold Hemoglobin Meter remove
NameBenchtop Conductivity Meter CON-B11 removeHawksley 1400 Haematocrit Centrifuge removeAGD Erma EL-120 ELectrolyte Analyzer removePlastic Urine Container Per Pack removeSkyla Hi POC Clinical Chemistry Analyzer removeTest Strip for ApexBio HemoSmart Gold Hemoglobin Meter remove
Image
SKUSF1033560130127-123SF1033560084-118SF1033560084-125SF1033560084-106SF1033560060-2SF1033560084-30
Rating
Price

$0.00

$690.00

$1,320.00

$8.20

$0.00

$9.50

Stock
Availability
Add to cart

DescriptionShipped From Abroad Model : CON-B11 The CON-B11 benchtop conductivity meter is suitable for routine conductivity, TDS and salinity testing of laboratory samples and provides the essential features required at an affordable price.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
The Hawksley Haematospin 1400 Centrifuges are built in the UK and are made from durable and high-quality components. These centrifuges are ideal for veterinary laboratories and practices specifically designed to produce reliable and accurate results on blood and urine. One of the main features of this centrifuge is that it takes both 2ml microtubes and 75mm microhaematocrits. The classic design of these centrifuges is used worldwide with guaranteed support for all servicing and parts. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Total Volume: 60mL.
  • Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
  • Made of premium PP material, it is durable for usage.
  • Some measurements can be used to not only use urine samples, it can also be used for other liquids.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The skyla Hi POC Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results.The use of skyla Hi in the management of diabetes enables better access to testing and rapid clinical decision making, discussion,and implementation of optimized treatment. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In Stock Twenty Five (25) Test Strip per Pack

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Benchtop Conductivity Meter Features:
  1. 7-inch colored capacitive touch screen with high resolution (1024x600) and sensitivity.
  2. Built-in microprocessor chip has Intelligent functions such as automatic calibration, ATC, data storage, clock display, USB output, function settings, wireless printing, and self-diagnosis information,  etc.
  3. It supports wireless bluetooth printing. Real-time data transfer to mobile phone via bluetooth is optional.
  4. Smart electrode status display to ensure accurate use.
  5. Adopt advanced conductivity measurement technology, with conductivity electrode (K=1), it can meet measuring accuracy requirement for range of 0.5μS/cm ~ 200mS/cm.
  6. Ability to switch among conductivity, TDS, salinity and resistivity. Multinomial calculation for TDS and salinity to ensure the conversion precision of the full range.
  7. With ATC conductivity electrode , Its measurement result is fast and precise.
  8. Auto recognition of 8 conductivity standard solution with 2 kinds of options: Europe & USA, and China.
  9. Can store 2000 sets of test data, which can be saved and transferred to USB memory stick and opened with Excel.
 
Benchtop Conductivity Meter Specifications:
Model CON-B11
Conductivity Measuring Range Conductivity: (0.00~20.00)μS/cm (20.0~200.0)μS/cm (200~2000)μS/cm (2.00~20.00)mS/cm (20.0~200.0)mS/cm
TDS: (0 ~ 100)g/L
Salinity: (0 ~ 100)ppt
Resistivity: (0 ~ 100)MΩ·cm
Resolution 0.01/0.1/1μS/cm; 0.01/0.1mS/cm
Accuracy Electrode: ±1.0% FS, Meter: ±1.5% FS
Temp. compensation Range (0 ~ 50)℃, auto
Electrode Constant 0.1 / 1 / 10 cm-1
Reference Temp. 25℃, 20℃, 18℃
Temperature Range (-10 ~ 110)℃
Resolution 0.1℃
Accuracy 5 ~ 60℃: ±0.5℃; Others: ±1.0℃
Other Parameters Display 7-inch colored capacitive touch screen
Data Storage 1000 sets
Power 12V (110-220, 50-60Hz adapter)
Communication Interface USB, RS232, Bluetooth
Size & Weight 240×170×70mm/600g
Working Conditions Temperature 5 ~ 35 ℃
Humidity ≤80%
IP grade IP54
Meter Kits 1) Conductivity meter
2) Electrode holder
3) Two-in-one electrode that consists of Platinum black electrode (K=1) and temperature probe.
4) Power adapter
External Size 215x170x40mm
Shipping Size 475x430x75mm
Net /Gross Weight (kg) 0.6/3
The Hawksley Haematospin 1400 Centrifuges are built in the UK and are made from durable and high-quality components. These centrifuges are ideal for veterinary laboratories and practices specifically designed to produce reliable and accurate results on blood and urine. One of the main features of this centrifuge is that it takes both 2ml microtubes and 75mm microhaematocrits. The classic design of these centrifuges is used worldwide with guaranteed support for all servicing and parts. Technical specifications:
  • Speed: 11,800rpm with 24- place rotor
  • RCF: 14,000g with 24-place rotor
  • Acceleration: 0-11,800rpm in 60 seconds, with 24-place rotor
  • Brake: Automatic
  • Noise: 62dB running with 24-place rotor
  • Motor: High precision AC/DC series wound motor, brush gear, computer wound coil winding, balance armature and high speed bearings.
  • Timer: 0-15 minute timer, graduated in 1 minute increments. Automatic switch at zero
  • Weight: 5.1Kg net (without rotor)
  • Dimensions: 23.5cm height x 27cm diameter, footprint 16cm diameter
  • Construction: Aluminium casing with a steel lid
  • Finish: Body cream white baked enamel, with matt black baked enamel lid
 
Click Here To Download Catalogue
Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface. Features:
  • Parameters: Na+,K+,Cl-, iCa++ / Li
  • It works on ISE principle
  • Sample Type: Whole blood, Serum, Plasma, Urine
  • Low reagent consumption
  • Sample requirement is only 90ul
  • 60 samples per hour
  • Automatic two point calibration after 4hrs and one point calibration with each sample analysis
  • Air bubble detection
  • Track reagents consumption and provides alerts
  • For low reagent volume
  • Precision testing facility to get CV and SD
  • Trilevel Quality Control with LJ plots of last 30days
  • Low aspiration volume
  • Fast sample processing
  • Accurate and Precise results
Technical Specifications:
Parameters Na+, K+, Cl– /Ca++
Principle Ion Selective Electrode (ISE)
Sample Type Analyses whole blood, serum, plasma and urine
Sample Volume ≤100 µL
Analysis Time ≤60 seconds
Throughout ≤60 samples per hour
Data Link Serial (RS232)
External Interface USB (Keyboard, Mouse)
Operating Condition 10° C to 35° C, Relative Humidity up to 85%
Storage Condition Temp: 10° C to 40° C
Relative Humidity up to 85% non- condensing
Power Supply 100 to 240 VAC ±10%, 50Hz
Dimensions 395 x 260 x 375 mm
Weight 7.5 kg
 
Click Here To Download Catalogue
  • Total Volume: 60mL.
  • Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
  • Made of premium PP material, it is durable for usage.
  • Some measurements can be used to not only use urine samples, it can also be used for other liquids.
skyla Hi Analyzer enables better access to testing and rapid clinical decision making, discussion, and implementation of optimized treatment. To get the result, only prepare <1 μl fingertips blood or venous blood (depends on test item) without pretreatment with easy steps and then read the result after 6 mins. The device allows two specimens be tested in one run and provides fully automatic procedures from checking the validity of cartridge to printing the results. Reagent Kit
  • HbA1C
  • CRP
  • Lipid Panel (TC,TG, HDL, LDL#)
  • Lipid Plus Panel (Glu,TC,TG, HDL, LDL#)
Main Specification
Principle
Turbidimetric Method / Biochemistry
Device
Testing Time
5~20 minutes (depends on test items)
Display and Interface
5″ TFT color touch screen LCD
Memory Capacity
50,000 test results
Dimension of Analyzer
270 x 188 x 148 mm
Weight of Analyzer
1.7 kg
Dimension of Printer Module
134 x 100 x 82.7 mm
Weight of Printer Module
0.37 kg
Power Supply
100~240 volts AC, 50-60Hz
Data Transmission
USB 2.0*4 / USB 3.0*1 / RS232*1 / RJ45*1 / Wi-Fi (optional)
Reagent and Samples
Samples
Fingertips blood or venous blood
Samples Volume
0.8 ~ 30 μL (depends on test item)
Storage Temperature (Reagent)
2 ~ 8ËšC
Humidity
Relative humidity < 95% (Non-condensing)
Temperature
10 ~ 32 ËšC
Click Here To Download Catalogue
Twenty Five (25) Test Strip per Pack
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare