Benchtop Multiparameter Water Quality Meter Features:

Highly accurate multi-parameter water quality analyzer with 8 measurement functions. They can custom setup a menu with 15 function parameters; the instrument is suitable for laboratory measurement of sample pH, ORP, ion concentration, conductivity, TDS, salinity, resistivity, dissolved oxygen concentration and saturation.

pH Mode Characteristics:

  1. Highly accurate multi-parameter water quality analyzer with large backlit LCD.
  2. 1 to 5 point calibration, automatic recognition of USA, NIST, DIN standard buffers.
  3. Automatic electrode diagnostics, display pH slope and zero offset.

 

Benchtop Multiparameter Water Quality Meter Specifications:
Model MWQ-B900 MWQ-B901 MWQ-B902 MWQ-B903 MWQ-B904
pH Range -2.000~20.000pH
Resolution 0.001, 0.01, 0.1pH, selectable
Accuracy ±0.002pH
Calibration Points 1 to 5 points
pH Buffer Options USA, NIST, DIN, 2 custom buffers
ORP Range ±1999.9mV
Resolution 0.1, 1mV, selectable
Accuracy ±0.2mV
Calibration Points 1 point 1 point 1 point
Ion Range 0.001~19999 (depending on the range of ISE)
Resolution 0.001, 0.01, 0.1, 1
Accuracy ±0.5% F.S. (monovalent), ±1% F.S. (divalent)
Measurement Units ppm, mg/L, mol/L, mmol/L
Calibration Points 2 to 5 points (0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000)
Conductivity Range 0.01~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm 0.01~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm
Resolution 0.001,0.01,0.1,1 0.001,0.01,0.1,1
Accuracy ±0.5% F.S. ±0.5% F.S.
Calibration Points 1 to 5 points 1 to 5 points
Calibration Solutions 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm
Temperature Coefficient Linear (0.0~10.0%/°C), pure water Linear (0.0~10.0%/°C), pure water
Reference Temperature 20/25°c 20/25°c
Cell Constant K=0.1, 1, 10 or custom K=0.1, 1, 10 or custom
TDS Range 0~10.00, 100.0, 1000ppm, 10.00, 200.0ppt 0~10.00, 100.0, 1000ppm, 10.00, 200.0ppt
Resolution 0.01,0.1,1 0.01,0.1,1
Accuracy ±1% F.S. ±1% F.S.
TDS Factor 0.1~1.0 (default 0.5) 0.1~1.0 (default 0.5)
Salinity Range 0.00~42.00psu, 0.00~80.00ppt 0.00~42.00psu, 0.00~80.00ppt 0.00~42.00psu, 0.00~80.00ppt
Resolution 0.01 0.01 0.01
Accuracy ±1% F.S. ±1% F.S. ±1% F.S.
Resistivity Range 0.00~20.00MΩ 0.00~20.00MΩ 0.00~20.00MΩ
Resolution 0.01 0.01 0.01
Accuracy ±1% F.S. ±1% F.S. ±1% F.S.
DO Range 0.00~20.00mg/L, 0.0~200.0% saturation 0.00~20.00mg/L, 0.0~200.0% saturation 0.00~20.00mg/L, 0.0~200.0% saturation
Resolution 0.01mg/L, 0.1% 0.01mg/L, 0.1% 0.01mg/L, 0.1%
Accuracy ±0.2mg/L, ±2.0% ±0.2mg/L, ±2.0% ±0.2mg/L, ±2.0%
Calibration Points 1or 2 points 1or 2 points 1or 2 points
Barometric Pressure Correction 60.0~112.5kPa/ 450~850mmHg, manual 60.0~112.5kPa/ 450~850mmHg, manual 60.0~112.5kPa/ 450~850mmHg, manual
Salinity Correction 0.0~50.0g/L, manual 0.0~50.0g/L, manual 0.0~50.0g/L, manual
General Spec. Temperature Compensation 0~100°C/32~212°F, manual or automatic
Memory 500 data sets, USB communication interface
Power Requirements DC5V power adapter
Sizes(W×D×H) 210×188×60
Shipping Size (W×D×H)(mm) 300x250x200
N.W./G.W. (kg) 1.5/2

Reviews

There are no reviews yet.

Be the first to review “Benchtop Multiparameter Water Quality Meter”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsBenchtop Multiparameter Water Quality Meter removeAGD Erma EL-120 ELectrolyte Analyzer removeAlcohol Pad Per Pack removeErma B-111 Bilirubin Meter removeSkyla Hi POC Clinical Chemistry Analyzer removeiSED Fully Automated ESR Analyzer remove
NameBenchtop Multiparameter Water Quality Meter removeAGD Erma EL-120 ELectrolyte Analyzer removeAlcohol Pad Per Pack removeErma B-111 Bilirubin Meter removeSkyla Hi POC Clinical Chemistry Analyzer removeiSED Fully Automated ESR Analyzer remove
Image
SKUSF1033560130127-41SF1033560084-125SF1033560084-64SF1033560084-6SF1033560060-2SF1033560084-129
Rating
Price

$0.00

$1,320.00

$4.25

$715.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped From Aboard  The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The skyla Hi POC Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results.The use of skyla Hi in the management of diabetes enables better access to testing and rapid clinical decision making, discussion,and implementation of optimized treatment. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Benchtop Multiparameter Water Quality Meter Features:
Highly accurate multi-parameter water quality analyzer with 8 measurement functions. They can custom setup a menu with 15 function parameters; the instrument is suitable for laboratory measurement of sample pH, ORP, ion concentration, conductivity, TDS, salinity, resistivity, dissolved oxygen concentration and saturation. pH Mode Characteristics:
  1. Highly accurate multi-parameter water quality analyzer with large backlit LCD.
  2. 1 to 5 point calibration, automatic recognition of USA, NIST, DIN standard buffers.
  3. Automatic electrode diagnostics, display pH slope and zero offset.
 
Benchtop Multiparameter Water Quality Meter Specifications:
Model MWQ-B900 MWQ-B901 MWQ-B902 MWQ-B903 MWQ-B904
pH Range -2.000~20.000pH
Resolution 0.001, 0.01, 0.1pH, selectable
Accuracy ±0.002pH
Calibration Points 1 to 5 points
pH Buffer Options USA, NIST, DIN, 2 custom buffers
ORP Range ±1999.9mV
Resolution 0.1, 1mV, selectable
Accuracy ±0.2mV
Calibration Points 1 point 1 point 1 point
Ion Range 0.001~19999 (depending on the range of ISE)
Resolution 0.001, 0.01, 0.1, 1
Accuracy ±0.5% F.S. (monovalent), ±1% F.S. (divalent)
Measurement Units ppm, mg/L, mol/L, mmol/L
Calibration Points 2 to 5 points (0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000)
Conductivity Range 0.01~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm 0.01~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm
Resolution 0.001,0.01,0.1,1 0.001,0.01,0.1,1
Accuracy ±0.5% F.S. ±0.5% F.S.
Calibration Points 1 to 5 points 1 to 5 points
Calibration Solutions 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm
Temperature Coefficient Linear (0.0~10.0%/°C), pure water Linear (0.0~10.0%/°C), pure water
Reference Temperature 20/25°c 20/25°c
Cell Constant K=0.1, 1, 10 or custom K=0.1, 1, 10 or custom
TDS Range 0~10.00, 100.0, 1000ppm, 10.00, 200.0ppt 0~10.00, 100.0, 1000ppm, 10.00, 200.0ppt
Resolution 0.01,0.1,1 0.01,0.1,1
Accuracy ±1% F.S. ±1% F.S.
TDS Factor 0.1~1.0 (default 0.5) 0.1~1.0 (default 0.5)
Salinity Range 0.00~42.00psu, 0.00~80.00ppt 0.00~42.00psu, 0.00~80.00ppt 0.00~42.00psu, 0.00~80.00ppt
Resolution 0.01 0.01 0.01
Accuracy ±1% F.S. ±1% F.S. ±1% F.S.
Resistivity Range 0.00~20.00MΩ 0.00~20.00MΩ 0.00~20.00MΩ
Resolution 0.01 0.01 0.01
Accuracy ±1% F.S. ±1% F.S. ±1% F.S.
DO Range 0.00~20.00mg/L, 0.0~200.0% saturation 0.00~20.00mg/L, 0.0~200.0% saturation 0.00~20.00mg/L, 0.0~200.0% saturation
Resolution 0.01mg/L, 0.1% 0.01mg/L, 0.1% 0.01mg/L, 0.1%
Accuracy ±0.2mg/L, ±2.0% ±0.2mg/L, ±2.0% ±0.2mg/L, ±2.0%
Calibration Points 1or 2 points 1or 2 points 1or 2 points
Barometric Pressure Correction 60.0~112.5kPa/ 450~850mmHg, manual 60.0~112.5kPa/ 450~850mmHg, manual 60.0~112.5kPa/ 450~850mmHg, manual
Salinity Correction 0.0~50.0g/L, manual 0.0~50.0g/L, manual 0.0~50.0g/L, manual
General Spec. Temperature Compensation 0~100°C/32~212°F, manual or automatic
Memory 500 data sets, USB communication interface
Power Requirements DC5V power adapter
Sizes(W×D×H) 210×188x60
Shipping Size (W×D×H)(mm) 300x250x200
N.W./G.W. (kg) 1.5/2
Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface. Features:
  • Parameters: Na+,K+,Cl-, iCa++ / Li
  • It works on ISE principle
  • Sample Type: Whole blood, Serum, Plasma, Urine
  • Low reagent consumption
  • Sample requirement is only 90ul
  • 60 samples per hour
  • Automatic two point calibration after 4hrs and one point calibration with each sample analysis
  • Air bubble detection
  • Track reagents consumption and provides alerts
  • For low reagent volume
  • Precision testing facility to get CV and SD
  • Trilevel Quality Control with LJ plots of last 30days
  • Low aspiration volume
  • Fast sample processing
  • Accurate and Precise results
Technical Specifications:
Parameters Na+, K+, Cl– /Ca++
Principle Ion Selective Electrode (ISE)
Sample Type Analyses whole blood, serum, plasma and urine
Sample Volume ≤100 µL
Analysis Time ≤60 seconds
Throughout ≤60 samples per hour
Data Link Serial (RS232)
External Interface USB (Keyboard, Mouse)
Operating Condition 10° C to 35° C, Relative Humidity up to 85%
Storage Condition Temp: 10° C to 40° C
Relative Humidity up to 85% non- condensing
Power Supply 100 to 240 VAC ±10%, 50Hz
Dimensions 395 x 260 x 375 mm
Weight 7.5 kg
 
Click Here To Download Catalogue
Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use. Size and packing of Medical Alcohol pad:
  • Pad Size: Unfolded: 30 x 60 mm (other size can be request ).
  • Folded: 30x30 mm, 30 x 35mm,can be 2ply or 4ply ( other size, ply can be request ).
  • Aluminum Package: 60 x 50 mm , 50 x 50mm approximate ( other size can be request ).
  • Packing: 100/200 pcs per inner box, 50/ 100 boxes per carton(packing can be request).
Use of Medical Alcohol pad:
  • For cleaning prior to injection or to disinfect the hurted skin for family and medical treatment organization use.
  • For preparation and immediate disinfection of skin, wound area orr Instrument and utensil.
Notice of Medical Alcohol pad:
  • Not for eyes;
  • keep out of reach of children;
  • For external use only;
  • please stop using if you feel allergic or amyctic
Materials - Non-Woven Fabric
Trademark - OEM/ODM
Specification - CE&ISO13485
   
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin. Feature
  • Auto zero function: Manual blanking not required
  • Dual wavelength measurement system:
  • 2 wave lengths 455nm and 575nm
  • Plays major role to remove the interference caused due to Hemolysis & turbidity of sample
  • LED Light source:
  • LED does not require replacement as it lasts longer
  • As compared to Lamp, LED are more suitable as there is no intensity fluctuations
  • No warm up time required.
  • Flexible unit selection:
  • Two units either mg/dl or umol/L are selectable, ease of reporting
  • Compact slot for Capillary:
  • Accuracy of results are directly related to proper alignment of Capillary
  • B-111 has the easiest mode to ensure precise values
  • Data transfer:
  • External device can be connected to instrument through RS232 por
  • USB port
Technical Specification
  • Light source - LED
  • Wavelength - 455nm and 575nm
  • Net weight - 1kg
  • Measuring range - 0-30 mg/dl , 510 umol/L
  • Display - 16×2 LCD module with backlight
  • Auto calibration - Yes
  • Sample type - Serum or plasma
  • Sample volume - 40-80μL
  • Test time - <5sec
  • Units - mg/dl or umol/L
  • Dimensions - 150 (W) × 115 (H) × 190 (D) mm
  • Interface - RS232
  • Reading cuvette - Heparinized micro capillary holder
  • Storage temperature - 15-40°c
  • Power supply - DC 9V(DC adapter)
  • Power consumption - <2W
skyla Hi Analyzer enables better access to testing and rapid clinical decision making, discussion, and implementation of optimized treatment. To get the result, only prepare <1 μl fingertips blood or venous blood (depends on test item) without pretreatment with easy steps and then read the result after 6 mins. The device allows two specimens be tested in one run and provides fully automatic procedures from checking the validity of cartridge to printing the results. Reagent Kit
  • HbA1C
  • CRP
  • Lipid Panel (TC,TG, HDL, LDL#)
  • Lipid Plus Panel (Glu,TC,TG, HDL, LDL#)
Main Specification
Principle
Turbidimetric Method / Biochemistry
Device
Testing Time
5~20 minutes (depends on test items)
Display and Interface
5″ TFT color touch screen LCD
Memory Capacity
50,000 test results
Dimension of Analyzer
270 x 188 x 148 mm
Weight of Analyzer
1.7 kg
Dimension of Printer Module
134 x 100 x 82.7 mm
Weight of Printer Module
0.37 kg
Power Supply
100~240 volts AC, 50-60Hz
Data Transmission
USB 2.0*4 / USB 3.0*1 / RS232*1 / RJ45*1 / Wi-Fi (optional)
Reagent and Samples
Samples
Fingertips blood or venous blood
Samples Volume
0.8 ~ 30 μL (depends on test item)
Storage Temperature (Reagent)
2 ~ 8˚C
Humidity
Relative humidity < 95% (Non-condensing)
Temperature
10 ~ 32 ˚C
Click Here To Download Catalogue
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Unlike traditional ESR methodologies that measure the aggregation of the red blood cells indirectly, the iSED measures it directly and expresses the values in mm/hr. Features:
  • Results in 20 Seconds

  • 100µL sample drawn directly from primary EDTA tube

  • Fully automated, walk-away operation

  • Random access

  • Positive patient identification via internal barcode reader

  • Compatible with pediatric tube

     
Technical Specifications: 
Principle of Measure: Photometrical
Results: “Printed mm/hr, Range from 1-130 mm/hr”
Sample Requirements: 500uL whole blood, collected in EDTA anti-coagulant tested 24 hours from venipuncture at room temperature or refrigerated.
Tube Requirements: 13 x 75 mm, pierceable capped tube
Quality Control: Barcoded Seditrol® QC
Barcode Reader: Internal
Printer: Internal
Interface Specifications: serial RS232 port for LIS connection
Weight: 14 kg
Dimensions (H x W x D): 36 x 27 x 34 (cm) /14.3 x 10.5 x13.4 (in)
Voltage: 100-240VAC
Frequency Range: 50-60 Hz
Power: 160W