Blood Pressure Monitor CT40

$0.00

Shipped From Abroad

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130132-5
Brands:: SUNTECH

Description

BP technology, the new SunTech CT40 is the ideal, affordable solution for clinical-grade spot-check measurements of blood pressure plus vital signs in hospitals and clinics. Ambulatory care, long-term care and low-acuity hospital departments can easily implement this versatile, user-friendly vital signs device that delivers SunTech clinical-grade performance, advanced features and digital connectivity.

Unique to the SunTech CT40, its modular design allows clinicians to easily make adaptations to the device while in the field – adding thermometry, SpO2 and Wi-Fi based solely on the needs of the patient.

Features

With the Suntech CT40, you can count on us to deliver:

Quality: Clinical-grade Advantage™ BP technology

Reliability: Manual SphygMode™ for real-time verification of BP readings without removing the cuff plus built-in memory for up to 99 charting sessions

Accuracy: Customizable BP averaging protocol to ensure accurate, consistent readings (SPRINT recommended)

Connectivity: HL7 messaging protocols for data transfer with network connection through built-in LAN/Ethernet, 2 USB ports or optional Wi-Fi

Flexibility: Modular design for addition of optional temperature and SpO2 modules

Simplicity: Intuitive user interface with LCD display

Options & Accessories
  • Covidien Filac® 3000 Thermometry
  • Masimo SET® SpO2 (preferred)
  • ChipOx Nellcor®-compatible SpO2
  • Mobile Stand
  • Barcode Scanner
  • Wi-Fi

 

Picture of the SunTech CT40 with available options and accessories, including the various modules.
Technical Specifications

SpO2 Specifications

Function Masimo M-LNCS DCI ChipOx
Saturation Normal (no motion) 70-100%Arms ± 2% 70-100%Arms ± 2%
Saturation Motion 70-100%Arms ± 3% N/A
Low Perfusion SpO2 +/-2% N/A
Pulse Heart rate ± 3% BPM 20-300 BPM: ±3 BPM
Pulse Heart rate w/motion ± 3% BPM 20-300 BPM: ±3 BPM

Temperature Specifications

Function Covidien Electronic Thermometer
Temperature Accuracy Quick Mode (Oral): ± 0.3°C
Temperature Accuracy Std. Mode (Aux/Rectal): ± 0.1°C
Temperature Accuracy Direct Mode ± 0.1°C
Response Time 4 sec (quick mode); 10-15 sec. (Axillary/Rectal); 60 sec.(direct mode)
Resolution 0.1°C

Blood Pressure Specifications

Specifications Values
Range:
  • Pressure: Diastolic: 20-200 mmHg (adult), 20-160 mmHg (pediatric).
  • Systolic: 40-260 mmHg (adult), 40-230 mmHg (pediatric)
  • Heart Rate: 30-220 BPM (beats per minute)
Accuracy (BP): Meets or exceeds ANSI/AAMI/ISO 81060-2:2013 standard for non-invasive accuracy (±5mmHg mean error with 8mmHg standard deviation).
General Specifications
Specifications Values
Conditions for Use: Operating: 10°C (50°F) to 40°C (104°F) 15 – 90% RH non-condensing – 700 kPa – 1060 kPa. Operating the monitor in an environment at maximum temperature can produce temperatures exceeding 41°C (41.6°C highest recorded) on a patient-applied part. It is up to the operator to determine if this temperature is too high based upon the condition of the patient and, if so, to ensure the ambient temperature of the environment is 38°C or below.
Storage: -20°C (-4°F) to 55°C (149°F) 15 – 90% RH non-condensing – 500 kPa – 1060 kPa. Performance can be affected if used or stored outside the specified temperature, humidity, or altitude listed in the ranges above.
Power: Internal power supply. Input: 100-240 VAC @ 1.5A max, 50-60 Hz. Output +9VDC @ 5A IEC 320 type input connector.
Battery: Type: 7.2v, 6600mAh Internal Lithium-Ion battery Run Time (full charge): ~20 hrs* / 200 BP cycles Charge Time: ~6 hrs @ 23deg Celsius +/- 2deg *Unit with BP, Temp, SpO2, Wi-Fi, barcode scanner
Calibration: The accuracy of cuff -pressure transducers/indicators should be verified bi-annually.
Safety Systems: Independent hardware over-pressure circuit and redundant software overpressure algorithm to limit cuff pressure to less than 300 mmHg (+20/-10mmHg). Independent hardware timing circuit and redundant software timer algorithm to limit the duration of a blood pressure cycle to less than 180 seconds.
Dimensions: Size (without thermometer option): 8” H x 6.75’’ W x 5.2’’ D or 215mm H x 190mm W x 140mm D
Standards: ANSI/AAMI ES60601-1:2005/(R)2012 and A1:2012, C1:2009/(R)2012 and A2:2010/(R)2012, EN 60601-1:2006/A1:2013, IEC 60601-1-2: 2007 EMC, IEC 80601-2-30: 2013, ISO 80601-2-61: 2011, ISO 15223-1:2012, ISO 10993-1, 2009, ISO 10993-5, 2009, EN ISO 10993-10, 2010, ISO 81060-2:2013, EN 50419: 2006, EN ISO 14971:2009, CSA C22.2 No. 60601-1, EN ISO 81060-1: 2012, IEC 60601-1-6: 2013
Classifications: Equipment Classification: Class IIa per MDD, Class I (Electrical Shock), Continuous mode of operation, CE
Ingress of liquid: Ingress Protection: IPX1: This device is protected against harmful effects of dripping water per IEC 60529.

 

Reviews

There are no reviews yet.

Be the first to review “Blood Pressure Monitor CT40”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsBlood Pressure Monitor CT40 removeDe Lineb Oxygen Face Mask removeFlowMir Disposable Turbine with Cardboard Mouthpiece removeCONTEC 08A Sphygmomanometer with SpO2 Function removeAccoson Sphygmomanometer removeOxygen Concentrator 3Ltr. remove
NameBlood Pressure Monitor CT40 removeDe Lineb Oxygen Face Mask removeFlowMir Disposable Turbine with Cardboard Mouthpiece removeCONTEC 08A Sphygmomanometer with SpO2 Function removeAccoson Sphygmomanometer removeOxygen Concentrator 3Ltr. remove
ImageFlowMir Disposable Turbine with Cardboard MouthpieceSphygmomanometer
SKUSF1033560130132-5SF1033560084-39SF1033560084-22SF1033560084-14SF1033560084-17SF1033560084-40
Rating
Price

$0.00

$1.40

$145.00

$0.00

$28.00

$273.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
De Lineb Oxygen Face Mask: This mask provides a method to transfer breathing oxygen gas from a storage tank to the lungs. Oxygen masks may cover only the nose and mouth (oral nasal mask) or the entire face (full-face mask).
  Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Spirometry testing requires maximum accuracy and hygiene. Each Flowmir disposable turbine, which includes a cardboard mouthpiece, has been individually factory calibrated with a computerized system and it is packaged individually. FlowMIR® is an inexpensive alternative to a costly reusable flowmeter and replaces the need for an antibacterial filter Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In Stock CONTEC 08A is a desktop Electronic Sphygmomanometer, High-definition color LCD display supply English/Chinese interface, Strong visibility. Fully automatic blood pressure measure, it can be a household sphygmomanometer which is used for adult, pediatric and neonatal. The device has the function of parameter measure, display and record output, and adopt data review interface such as "data list", "trend chart", "big font”, with SpO2 measure function. It can be applied to the Clinic, physical center.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock
  • Adult Velcro Cuff for maximum arm circumference of 34.3cm
  • Made in UK & guaranteed accurate to BS EN 1060 – 1
  • Lightweight diecast case
  • Shatter-proof plastic manometer tube
  • Mercury reservoir with isolation valve
  • Steel hinge pivots
  • Range 0 – 300mmHg
  • Supplied with adult size cuff & latex-free bulb
Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Customized: Customized
Certification: CE, FDA, ISO13485
Scale: Medium
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content

BP technology, the new SunTech CT40 is the ideal, affordable solution for clinical-grade spot-check measurements of blood pressure plus vital signs in hospitals and clinics. Ambulatory care, long-term care and low-acuity hospital departments can easily implement this versatile, user-friendly vital signs device that delivers SunTech clinical-grade performance, advanced features and digital connectivity.

Unique to the SunTech CT40, its modular design allows clinicians to easily make adaptations to the device while in the field – adding thermometry, SpO2 and Wi-Fi based solely on the needs of the patient.
Features
With the Suntech CT40, you can count on us to deliver: Quality: Clinical-grade Advantage™ BP technology Reliability: Manual SphygMode™ for real-time verification of BP readings without removing the cuff plus built-in memory for up to 99 charting sessions Accuracy: Customizable BP averaging protocol to ensure accurate, consistent readings (SPRINT recommended) Connectivity: HL7 messaging protocols for data transfer with network connection through built-in LAN/Ethernet, 2 USB ports or optional Wi-Fi Flexibility: Modular design for addition of optional temperature and SpO2 modules Simplicity: Intuitive user interface with LCD display
Options & Accessories
  • Covidien Filac® 3000 Thermometry
  • Masimo SET® SpO2 (preferred)
  • ChipOx Nellcor®-compatible SpO2
  • Mobile Stand
  • Barcode Scanner
  • Wi-Fi
 
Picture of the SunTech CT40 with available options and accessories, including the various modules.
Technical Specifications
SpO2 Specifications
Function Masimo M-LNCS DCI ChipOx
Saturation Normal (no motion) 70-100%Arms ± 2% 70-100%Arms ± 2%
Saturation Motion 70-100%Arms ± 3% N/A
Low Perfusion SpO2 +/-2% N/A
Pulse Heart rate ± 3% BPM 20-300 BPM: ±3 BPM
Pulse Heart rate w/motion ± 3% BPM 20-300 BPM: ±3 BPM
Temperature Specifications
Function Covidien Electronic Thermometer
Temperature Accuracy Quick Mode (Oral): ± 0.3°C
Temperature Accuracy Std. Mode (Aux/Rectal): ± 0.1°C
Temperature Accuracy Direct Mode ± 0.1°C
Response Time 4 sec (quick mode); 10-15 sec. (Axillary/Rectal); 60 sec.(direct mode)
Resolution 0.1°C
Blood Pressure Specifications
Specifications Values
Range:
  • Pressure: Diastolic: 20-200 mmHg (adult), 20-160 mmHg (pediatric).
  • Systolic: 40-260 mmHg (adult), 40-230 mmHg (pediatric)
  • Heart Rate: 30-220 BPM (beats per minute)
Accuracy (BP): Meets or exceeds ANSI/AAMI/ISO 81060-2:2013 standard for non-invasive accuracy (±5mmHg mean error with 8mmHg standard deviation).
General Specifications
Specifications Values
Conditions for Use: Operating: 10°C (50°F) to 40°C (104°F) 15 – 90% RH non-condensing - 700 kPa - 1060 kPa. Operating the monitor in an environment at maximum temperature can produce temperatures exceeding 41°C (41.6°C highest recorded) on a patient-applied part. It is up to the operator to determine if this temperature is too high based upon the condition of the patient and, if so, to ensure the ambient temperature of the environment is 38°C or below.
Storage: -20°C (-4°F) to 55°C (149°F) 15 – 90% RH non-condensing - 500 kPa - 1060 kPa. Performance can be affected if used or stored outside the specified temperature, humidity, or altitude listed in the ranges above.
Power: Internal power supply. Input: 100-240 VAC @ 1.5A max, 50-60 Hz. Output +9VDC @ 5A IEC 320 type input connector.
Battery: Type: 7.2v, 6600mAh Internal Lithium-Ion battery Run Time (full charge): ~20 hrs* / 200 BP cycles Charge Time: ~6 hrs @ 23deg Celsius +/- 2deg *Unit with BP, Temp, SpO2, Wi-Fi, barcode scanner
Calibration: The accuracy of cuff -pressure transducers/indicators should be verified bi-annually.
Safety Systems: Independent hardware over-pressure circuit and redundant software overpressure algorithm to limit cuff pressure to less than 300 mmHg (+20/-10mmHg). Independent hardware timing circuit and redundant software timer algorithm to limit the duration of a blood pressure cycle to less than 180 seconds.
Dimensions: Size (without thermometer option): 8” H x 6.75’’ W x 5.2’’ D or 215mm H x 190mm W x 140mm D
Standards: ANSI/AAMI ES60601-1:2005/(R)2012 and A1:2012, C1:2009/(R)2012 and A2:2010/(R)2012, EN 60601-1:2006/A1:2013, IEC 60601-1-2: 2007 EMC, IEC 80601-2-30: 2013, ISO 80601-2-61: 2011, ISO 15223-1:2012, ISO 10993-1, 2009, ISO 10993-5, 2009, EN ISO 10993-10, 2010, ISO 81060-2:2013, EN 50419: 2006, EN ISO 14971:2009, CSA C22.2 No. 60601-1, EN ISO 81060-1: 2012, IEC 60601-1-6: 2013
Classifications: Equipment Classification: Class IIa per MDD, Class I (Electrical Shock), Continuous mode of operation, CE
Ingress of liquid: Ingress Protection: IPX1: This device is protected against harmful effects of dripping water per IEC 60529.
 
De Lineb Oxygen Face Mask: This mask provides a method to transfer breathing oxygen gas from a storage tank to the lungs. Oxygen masks may cover only the nose and mouth (oral nasal mask) or the entire face (full-face mask).
Features:
  • Non-toxic PVC
  • Medium concentration
  • Adjustable nose clip
  • Non-Autoclavable
  • Available size: adult, child
  Technical Specifications:
  • Product Name: Oxygen Mask
  • Material: Medical grade PVC
  • Color: Green
  • Size: S, M, L, L , XL
  • Package: PE bag
  • Tube size: 2m
  • Nose Clip: adjustable
  • Disposable Medical Oxygen Face Mask Types MSLMK01
 
    • Comfortable Packaging
    • Singularly Tested and Packed
    • Always 100% accurate and hygienic
    • No Calibration required
    • No Sterilization required
    • No Antibacterial Filter required
    • No Cross Contamination
    • Not affected by Vapour Condensation
    • Not affected by Ambient conditions
    •  A full Spirometry session can be performed, including a Bronchial Challenge and POST Bronchodilator test. For each patient after the Spirometry test, both turbine and spirometer mouthpiece are thrown away
    • .
   
CONTEC 08A is a desktop Electronic Sphygmomanometer, High-definition color LCD display supply English/Chinese interface, Strong visibility. Fully automatic blood pressure measure, it can be a household sphygmomanometer which is used for adult, pediatric and neonatal. The device has the function of parameter measure, display and record output, and adopt data review interface such as "data list", "trend chart", "big font”, with SpO2 measure function. It can be applied to the Clinic, physical center. Features
  • Fully automatic blood pressure measure
  • The Electronic Sphygmomanometer stores the measure results of three users automatically, and up to 100 items for every user.It can satisfy blood pressure measure requirement of all your family.
  • Three kinds of measure modes : adult, pediatric and neonatal.
  • By data review interface such as "data list","trend graph","big font", NIBP data is clear at a glance.
  • With SpO2 measure function.
  • Has the function of physiological alarm.It can be set the alarm limits,when blood pressure is higher than the high limit or lower than the low limit, the physiological alarm will occur.Alarm switch can be set.
  • Screen displays prompt message when the power is low,and the device gives low power prompt sound.The prompt sound switch can be set.
  • When there are factors which affect the measure in the process of measure and the device can't get the measure result,the device can display the corresponding error message.
  • With short-time power storage function, when replacing the battery, the clock time function can't be affected.
  • Supply two kinds of NIBP measure unit: mmHg / kPa
  • Store measure results with date and time.
  • High-definition color LCD display,supply English/Chinese interface, strong visibility.
  • Communicate with PC,PC software can achieve data review, analysis measure results, seeing trend, printing reports and other functions.
  • Function of automatic power-off.
 
  • Adult Velcro Cuff for maximum arm circumference of 34.3cm
  • Made in UK & guaranteed accurate to BS EN 1060 – 1
  • Lightweight diecast case
  • Shatter-proof plastic manometer tube
  • Mercury reservoir with isolation valve
  • Steel hinge pivots
  • Range 0 – 300mmHg
  • Supplied with adult size cuff & latex-free bulb
   
Our anesthesia system is a precision crafted, life-sustaining device. When moving to an O2 concentrator from tanks, you should expect the same attention to detail. A full 8lpm O2 flowrate capability - gives better performance at lower flow rates 20psi pressure output - your anesthesia system was designed to work from pressure O2 concentrations average 93% +/- 3% Built-in Low O2 Concentration Alarm Small footprint of 15"x15"x22" Remarkably quiet Save money over time vs. tanks Eliminate contamination hazards of tanks coming and going in your facility Works with ALL manufacturer's brands of anesthesia systems
    • .
   
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare