New

Bluetooth Conductivity Meter

Ask for Price$0.00

Shipped From Abroad

Model : CON-BS50M; CON-BS50H

This bluetooth conductivity meter supports wireless data transmission, making it easier to record and monitor data.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Brands:: Scitek

Description

Bluetooth Conductivity Meter Features:

This wireless bluetooth conductivity meter accurately measures the conductivity of water. Crafted from rugged materials for use in harsh environments, the conductivity meter measures a wide range of conductivity, making it suitable for a variety of applications. The high-definition display visualizes salinity, TDS, resistivity, and conductivity. Temperature compensation type, electrode constants, pure water compensation factor, temperature compensation factor, and reference temperature to TDS conversion factor are all selectable online.

  1. High measurement accuracy: 0.5% F.S.
  2. 1 to 3 point calibration, automatic recognition of conductivity standards
  3. Automatic temperature compensation ensures accurate measurements over the full range.
  4. Compact and lightweight, the meter is easy to carry and use in different locations.
  5. Built-in memory or data logging allows storage and retrieval of measurement data.
  6. Automatic endpoint lock retains stable readings for easy viewing and recording
  7. Multi-parameter measurement can be connected to the dissolved oxygen meter and display the measured value simultaneously

 

Bluetooth Conductivity Meter Specifications:

 

Model CON-BS50M CON-BS50H
Conductivity
Range 10ÎĽS/cm to 20mS/cm 100ÎĽS/cm to 200mS/cm
Resolution 0.001, 0.01, 0.1, 1
Accuracy ±0.5% F.S.
Calibration Points 1 to 3 points
Calibration Solutions 84µS, 1413µS, 12.88mS, 111.8mS
TDS
Range 0 to 20.00g/L 0 to 200.0g/L
Resolution 0.01, 0.1, 1
Accuracy ±1% F.S.
TDS Factor 0.01 to 1.00 (Default 0.5)
Salinity
Range (Practical Salinity) 0.00 to 10.00psu 0.00 to 42.00psu
Range (Natural Seawater) 0.00 to 10.00ppt 0.00 to 80.00ppt
Range (%) 0.00 to 1.00% 0.00 to 8.00%
Resolution 0.01
Accuracy ±1% F.S.
Resistivity
Range 0.00 to 10.00MΩ 0.00 to 1.00MΩ
Resolution 0.01, 0.1, 1
Accuracy ±1% F.S.
Conductivity Ash
Range 0 to 100%
Accuracy ±1% F.S.
Measurement Modes Refined sugar or raw sugar
General Specifications
Temperature Compensation 0 to 100°C/32 to 212°F, automatic
Temperature Coefficient Linear (0.0 to 10.0%/°C), non-linear, USP, EP
Pure Water Compensation Yes
Reference Temperature 20/25°C
Cell Constant K=1 K=10
Stability Criteria Fast, standard, slow
Measurement Modes Continuous or auto-read
Timed Interval Readings 10, 30, 60, 300 seconds or off
Calibration Due Alarm 1 to 99 days or off
Data Transfer Send to memory or printer
Password Protection 6 digits
Connectivity Bluetooth 4.0 or later
Max Wireless Range 10m/32.8ft
Power 2×1.2V lithium batteries or AAA batteries
Sizes(WĂ—DĂ—H) 185(L)x40(Dia.)
Shipping Size (WĂ—DĂ—H)(mm) 280x80x250
N.W./G.W. (kg) 0.1/1.5

Reviews

There are no reviews yet.

Be the first to review “Bluetooth Conductivity Meter”

Your email address will not be published. Required fields are marked *

Quick Comparison

Bluetooth Conductivity Meter removeNikon SMZ745 Stereoscopic Microscope removeDiscover 14 Panel Cup with Adulterants Per Pack removeErma B-111 Bilirubin Meter removeSkyla HB1 POC Clinical Chemistry Auto Analyzer removeAGD Erma EL-120 ELectrolyte Analyzer remove
NameBluetooth Conductivity Meter removeNikon SMZ745 Stereoscopic Microscope removeDiscover 14 Panel Cup with Adulterants Per Pack removeErma B-111 Bilirubin Meter removeSkyla HB1 POC Clinical Chemistry Auto Analyzer removeAGD Erma EL-120 ELectrolyte Analyzer remove
ImageNikon SMZ745 Stereoscopic MicroscopeDrug Test Cup
SKUSF1033560084-49SF1033560084-28SF1033560084-6SF1033560060-1SF1033560084-125
Rating
Price

Ask for Price$0.00

Ask for Price$0.00

Ask for Price$0.00

Ask for Price$0.00

Ask for Price$0.00

Ask for Price$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad Model : CON-BS50M; CON-BS50H This bluetooth conductivity meter supports wireless data transmission, making it easier to record and monitor data.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Nikon SMZ745 Stereoscopic Microscope: Featuring a zoom magnification of 7.5X and a long working distance of 115mm, Nikon SMZ745 microscopes are well suited for both industrial and biomedical applications. The adoption of a new total reflection prism produces brighter images with higher contrast, and the anti-mold design allows the microscope to be used in environments where the temperature and humidity are high. The SMZ-745T trinocular model comes equipped with a microscope camera port and a built-in 0.55x c-mount adapter, permitting direct mounting of Nikon DS Series Digital Cameras. Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self contained and the entire cup is tamper resistant. Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Aboard  The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The skyla HB1 Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. The portable design of the clinical chemistry analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped From Abroad
Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Bluetooth Conductivity Meter Features:
This wireless bluetooth conductivity meter accurately measures the conductivity of water. Crafted from rugged materials for use in harsh environments, the conductivity meter measures a wide range of conductivity, making it suitable for a variety of applications. The high-definition display visualizes salinity, TDS, resistivity, and conductivity. Temperature compensation type, electrode constants, pure water compensation factor, temperature compensation factor, and reference temperature to TDS conversion factor are all selectable online.
  1. High measurement accuracy: 0.5% F.S.
  2. 1 to 3 point calibration, automatic recognition of conductivity standards
  3. Automatic temperature compensation ensures accurate measurements over the full range.
  4. Compact and lightweight, the meter is easy to carry and use in different locations.
  5. Built-in memory or data logging allows storage and retrieval of measurement data.
  6. Automatic endpoint lock retains stable readings for easy viewing and recording
  7. Multi-parameter measurement can be connected to the dissolved oxygen meter and display the measured value simultaneously
 
Bluetooth Conductivity Meter Specifications:
 
Model CON-BS50M CON-BS50H
Conductivity
Range 10ÎĽS/cm to 20mS/cm 100ÎĽS/cm to 200mS/cm
Resolution 0.001, 0.01, 0.1, 1
Accuracy ±0.5% F.S.
Calibration Points 1 to 3 points
Calibration Solutions 84µS, 1413µS, 12.88mS, 111.8mS
TDS
Range 0 to 20.00g/L 0 to 200.0g/L
Resolution 0.01, 0.1, 1
Accuracy ±1% F.S.
TDS Factor 0.01 to 1.00 (Default 0.5)
Salinity
Range (Practical Salinity) 0.00 to 10.00psu 0.00 to 42.00psu
Range (Natural Seawater) 0.00 to 10.00ppt 0.00 to 80.00ppt
Range (%) 0.00 to 1.00% 0.00 to 8.00%
Resolution 0.01
Accuracy ±1% F.S.
Resistivity
Range 0.00 to 10.00MΩ 0.00 to 1.00MΩ
Resolution 0.01, 0.1, 1
Accuracy ±1% F.S.
Conductivity Ash
Range 0 to 100%
Accuracy ±1% F.S.
Measurement Modes Refined sugar or raw sugar
General Specifications
Temperature Compensation 0 to 100°C/32 to 212°F, automatic
Temperature Coefficient Linear (0.0 to 10.0%/°C), non-linear, USP, EP
Pure Water Compensation Yes
Reference Temperature 20/25°C
Cell Constant K=1 K=10
Stability Criteria Fast, standard, slow
Measurement Modes Continuous or auto-read
Timed Interval Readings 10, 30, 60, 300 seconds or off
Calibration Due Alarm 1 to 99 days or off
Data Transfer Send to memory or printer
Password Protection 6 digits
Connectivity Bluetooth 4.0 or later
Max Wireless Range 10m/32.8ft
Power 2x1.2V lithium batteries or AAA batteries
Sizes(WĂ—DĂ—H) 185(L)x40(Dia.)
Shipping Size (WĂ—DĂ—H)(mm) 280x80x250
N.W./G.W. (kg) 0.1/1.5
Nikon SMZ745 Stereoscopic Microscope: Featuring a zoom magnification of 7.5X and a long working distance of 115mm, Nikon SMZ745 microscopes are well suited for both industrial and biomedical applications. The adoption of a new total reflection prism produces brighter images with higher contrast, and the anti-mold design allows the microscope to be used in environments where the temperature and humidity are high. The SMZ-745 trinocular model comes equipped with a microscope camera port and a built-in 0.55x c-mount adapter, permitting direct mounting of Nikon DS Series Digital Cameras. Features:
  • Trinocular optical head for monitoring and digital imaging
  • Impressive 7.5x zoom magnification
  • 115 mm working distance
  • Maximum ergonomics
  • Rugged, durable design suits a variety of applications and environments
Technical Specifications:
Optical system Greenough optical system
Total magnification 3.35-300x, depending on eyepiece and auxiliary objective used
Vertical tube Built-in C-mount 0.55x magnification lens (F.N. 11), compatible with 2/3 in. or smaller CCD
Eyepiece tube Fixed type
Eyepiece inclination 45°
Interpupillary distance adjustment 52-75 mm
Eyepieces (with diopter adjustment) C-W 10xB (F.N. 22), C-W 15x (F.N. 16), C-W 20x (F.N. 12.5), C-W 30x (F.N. 7)
Zooming ratio 7.5:1 (approx.)
Zooming range 0.67-5x
Auxiliary objectives G-AL 0.5x (W.D. 211 mm), G-AL 0.7x (W.D. 150 mm), G-AL 1.5x (W.D. 61 mm), G-AL 2x (W.D. 43.5 mm)
Working distance 115 mm
     
 
 
All-in-One Design
FDA 510(K) & CLIA Waived Up to 99% accuracy rate Results in as little as 1 minute 24 Month Shelf Life from Date of Manufacture Secure, seal and send to lab for confirmation Built in temperature strip Available to test up to 17 substances with adulterants or 18 without adulterants Adulterants available
 
 
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40ÎĽl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin. Feature
  • Auto zero function: Manual blanking not required
  • Dual wavelength measurement system:
  • 2 wave lengths 455nm and 575nm
  • Plays major role to remove the interference caused due to Hemolysis & turbidity of sample
  • LED Light source:
  • LED does not require replacement as it lasts longer
  • As compared to Lamp, LED are more suitable as there is no intensity fluctuations
  • No warm up time required.
  • Flexible unit selection:
  • Two units either mg/dl or umol/L are selectable, ease of reporting
  • Compact slot for Capillary:
  • Accuracy of results are directly related to proper alignment of Capillary
  • B-111 has the easiest mode to ensure precise values
  • Data transfer:
  • External device can be connected to instrument through RS232 por
  • USB port
Technical Specification
  • Light source - LED
  • Wavelength - 455nm and 575nm
  • Net weight - 1kg
  • Measuring range - 0-30 mg/dl , 510 umol/L
  • Display - 16Ă—2 LCD module with backlight
  • Auto calibration - Yes
  • Sample type - Serum or plasma
  • Sample volume - 40-80ÎĽL
  • Test time - <5sec
  • Units - mg/dl or umol/L
  • Dimensions - 150 (W) Ă— 115 (H) Ă— 190 (D) mm
  • Interface - RS232
  • Reading cuvette - Heparinized micro capillary holder
  • Storage temperature - 15-40°c
  • Power supply - DC 9V(DC adapter)
  • Power consumption - <2W
Skyla HB1 Clinical Chemistry Analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. HB1 provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. Only needs 200µl of blood (whole blood, serum or plasma is accepted.) and no sample preparation is required. All steps are designed automatically from checking the validity of reagent discs and cartridges to printing the results. Over 30 test parameters are allowed with fast analysis and results in 15 minutes. Internal Quality Control (IQC) with self-calibration of optical system, chemicals stability and interference alerts functions monitor and ensure the results with high accuracy. Available Test Panels
  • Renal Function - BUN, CREA eGFR
  • Liver Function - ALB, TP, ALP, ALT, AST, TBIL, DBIL, GGT, LDH A/G#, GLOB#, IBIL
  • Lipid Metabolism - TG, TC, HDL LDL#, VLDL
  • Pancreatitis Markers - AMY, LIPA
  • Carbohydrate Metabolism and Others - GLU , CPK, UA, LAC
  • Inflammatory Markers - CRP
  • Electrolyte - Na, K, Cl, Ca, PHOS, Mg, tCO2
SPECIFICATION Principle
  • Colormetric System : LEDs 340nm~940nm wavelength
Sample & Panel
  • Test Profiles : Panels
  • Measurement Time - Panel: up to 15 tests/ 15 min
  • Sample Type & Volume : 200 ÎĽl whole blood (PCV<60%), plasma, serum 
Device
  • User Interface : 5 inch color LCD touch screen
  • Internal Memory : Store up to 50,000 analysis results
  • Printer : Built in thermal printer or external USB printer (PCL 3GUI)
  • USB Socket : USB type A (Host) for external USB Printer, USB flash drive (FAT) or external barcode scanner
  • Data transmission to PC : RS232 serial port or RJ45 (LAN)
  • Dimensions : 233 (W) X 285 (D) X 300 (H) mm
  • Weight : 5.5 kg
Operating Condition
  • Temperature / Humidity : 10 to 32ËšC / 5 to 90 %
 
Click Here To Download Catalogue
Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface. Features:
  • Parameters: Na+,K+,Cl-, iCa++ / Li
  • It works on ISE principle
  • Sample Type: Whole blood, Serum, Plasma, Urine
  • Low reagent consumption
  • Sample requirement is only 90ul
  • 60 samples per hour
  • Automatic two point calibration after 4hrs and one point calibration with each sample analysis
  • Air bubble detection
  • Track reagents consumption and provides alerts
  • For low reagent volume
  • Precision testing facility to get CV and SD
  • Trilevel Quality Control with LJ plots of last 30days
  • Low aspiration volume
  • Fast sample processing
  • Accurate and Precise results
Technical Specifications:
Parameters Na+, K+, Cl– /Ca++
Principle Ion Selective Electrode (ISE)
Sample Type Analyses whole blood, serum, plasma and urine
Sample Volume ≤100 µL
Analysis Time ≤60 seconds
Throughout ≤60 samples per hour
Data Link Serial (RS232)
External Interface USB (Keyboard, Mouse)
Operating Condition 10° C to 35° C, Relative Humidity up to 85%
Storage Condition Temp: 10° C to 40° C
Relative Humidity up to 85% non- condensing
Power Supply 100 to 240 VAC ±10%, 50Hz
Dimensions 395 x 260 x 375 mm
Weight 7.5 kg
 
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare