BLX-10 Intraoral Imaging High Frequency X-ray Machine

$0.00

Shipped From Abroad

The BLX-10 Intraoral Imaging High-Frequency X-ray Machine provides portable, high-quality dental imaging with adjustable exposure times and low radiation leakage. Its compact design and compatibility with various imaging mediums make it an ideal choice for modern dental practices seeking efficiency and safety in radiography.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Brands:: Fsfame

Description

The BLX-10 Intraoral Imaging High-Frequency X-ray Machine is designed for dental professionals seeking a portable and efficient radiography solution. Operating at a high frequency of 30 kHz, it ensures clear and stable images. The device features adjustable exposure times ranging from 0.05 to 1.8 seconds, catering to various diagnostic needs. Its compact design, weighing approximately 1.95 kg, allows for easy transportation and use in multiple clinical settings. With a tube voltage of 70 kV and a tube current of 1 mA, it delivers precise imaging while maintaining radiation leakage below 20 μGy/h, adhering to international safety standards. The BLX-10 is compatible with both traditional dental films and digital sensors, making it a versatile addition to any dental practice.

Key Features
  • High-Frequency Operation: Operates at 30 kHz, ensuring stable and clear imaging results.

  • Adjustable Exposure Time: Exposure time ranges from 0.05 to 1.8 seconds, allowing flexibility based on diagnostic requirements.

  • Toshiba 0.3mm Micro-Focus Tube: Delivers clearer and more detailed images, crucial for precise diagnostics.

  • Radiation Protection: Equipped with multilayer X-ray shielding, ensuring safety for both operator and patient.

  • Portable Design: Compact in volume and light in weight (approximately 1.95 kg), convenient for carrying and operation.

  • Compatibility: Compatible with both traditional dental films and digital sensors, facilitating integration into different imaging workflows.

Specifications
Tube Voltage 70 kV (fixed)
Tube Current 1 mA (fixed)
Frequency 30 kHz
Exposure Time 0.05–1.8 seconds
Focus Spot Size 0.3 mm (Toshiba tube)
Radiation Leakage <20 μGy/h
Power Supply DC 16.8V rechargeable battery
Weight Approximately 1.95 kg
Dimensions 215 × 140 × 160 mm
Operating Temperature 5–40ºC
Humidity <80% RH

Reviews

There are no reviews yet.

Be the first to review “BLX-10 Intraoral Imaging High Frequency X-ray Machine”

Your email address will not be published. Required fields are marked *

Quick Comparison

BLX-10 Intraoral Imaging High Frequency X-ray Machine removeSphygmomanometer Table Top Aneroid removeWall Mounted Sphygmomanometer Aneroid removePortable X-Ray Unit removeMobile Dental X-ray Unit with Chair removeGenoray Papaya Plus Panoramic Dental X-Ray remove
NameBLX-10 Intraoral Imaging High Frequency X-ray Machine removeSphygmomanometer Table Top Aneroid removeWall Mounted Sphygmomanometer Aneroid removePortable X-Ray Unit removeMobile Dental X-ray Unit with Chair removeGenoray Papaya Plus Panoramic Dental X-Ray remove
Image
SKUSF103356013048SF103356013047SF103356013069SF1033560069SF10335601104
Rating
Price

$0.00

$0.00

$0.00

$495.00

$836.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad The BLX-10 Intraoral Imaging High-Frequency X-ray Machine provides portable, high-quality dental imaging with adjustable exposure times and low radiation leakage. Its compact design and compatibility with various imaging mediums make it an ideal choice for modern dental practices seeking efficiency and safety in radiography.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock
The SIX00 range of sphygmomanometers represent our premium quality aneroid sphygmomanometers. The sensitivity and specificity of these models, help to classify an individual as hypertensive or normotensive. Delivery & Availability: Typically 4-12 Working Days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock
The Six Inch range of sphygmomanometers provide clinicians with amazing quality at affordable prices. A modern solution for all locations with innovative and practical features included. Delivery & Availability: Typically 4-12 Working Days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Features: 1. The device is DC high frequency portable dental unit, small, light and nearly no radiation. 2. There are manual buttons installed on the surface of shell, operate easily, all of components are installed in the central PC board, insulation vacuum and sealed stereotype protection make its brilliant features.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad
Product Description:
  1. The microprocessor-controlled timer brings high-tech X-ray imaging at your fingertips.
  2. The control panel allows an accurate and fast exposure time selection while protecting the head during X-ray examinations.
  3. Fitted with 70KV 8mA tube with preheating grid, the machine has been specially designed for intraoral dental diagnosis applications
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
The HQ-760DY Dry Imager is a thermo-graphic film processor designed for digital radiography imaging. It is the one and only domestically engineered medical dry thermal imager Delivery & Availability: Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content

The BLX-10 Intraoral Imaging High-Frequency X-ray Machine is designed for dental professionals seeking a portable and efficient radiography solution. Operating at a high frequency of 30 kHz, it ensures clear and stable images. The device features adjustable exposure times ranging from 0.05 to 1.8 seconds, catering to various diagnostic needs. Its compact design, weighing approximately 1.95 kg, allows for easy transportation and use in multiple clinical settings. With a tube voltage of 70 kV and a tube current of 1 mA, it delivers precise imaging while maintaining radiation leakage below 20 μGy/h, adhering to international safety standards. The BLX-10 is compatible with both traditional dental films and digital sensors, making it a versatile addition to any dental practice.

Key Features
  • High-Frequency Operation: Operates at 30 kHz, ensuring stable and clear imaging results.

  • Adjustable Exposure Time: Exposure time ranges from 0.05 to 1.8 seconds, allowing flexibility based on diagnostic requirements.

  • Toshiba 0.3mm Micro-Focus Tube: Delivers clearer and more detailed images, crucial for precise diagnostics.

  • Radiation Protection: Equipped with multilayer X-ray shielding, ensuring safety for both operator and patient.

  • Portable Design: Compact in volume and light in weight (approximately 1.95 kg), convenient for carrying and operation.

  • Compatibility: Compatible with both traditional dental films and digital sensors, facilitating integration into different imaging workflows.

Specifications
Tube Voltage 70 kV (fixed)
Tube Current 1 mA (fixed)
Frequency 30 kHz
Exposure Time 0.05–1.8 seconds
Focus Spot Size 0.3 mm (Toshiba tube)
Radiation Leakage <20 μGy/h
Power Supply DC 16.8V rechargeable battery
Weight Approximately 1.95 kg
Dimensions 215 × 140 × 160 mm
Operating Temperature 5–40ºC
Humidity <80% RH
Sphygmomanometer Table Top Aneroid The six range of sphygmomanometers represent our premium quality aneroid sphygmomanometers. The sensitivity and specificity of these models, help to classify an individual as hypertensive or normotensive. The desk model is fitted with a large carrying handle and cuff storage basket plus rubber feet for stability. Product: Made in UK and guaranteed accurate to ISO 81060-1
  • Range 0–300mmHg, with the scale graduations starting at zero
  • Clear white face with sharp black scale
  • Lightweight ABS cuff container which is very easy to clean
  • Fine red pointer gives precise indication
  • Fitted with your choice of Velcro or Ambidex cuff
  • Tough bright white ABS construction with built in carrying handle
  • New flexible shock mount resists any damage to the gauge
.
Wall Mounted Sphygmomanometer Aneroid The Six Inch range of sphygmomanometers provide clinicians with amazing quality at affordable prices. A modern solution for all locations with innovative and practical features included. The precision mechanism ensures smooth and reliable performance and gives immediate response to changes in cuff pressure. The wall model features a swivel wall bracket for easy viewing and cuff storage is included behind the gauge  Features of Wall Mounted Sphygmomanometer Aneroid:
  • Made in UK and guaranteed accurate to ISO 81060-1
  • Range 0–300mmHg, with the scale graduations starting at zero
  • Clear white face with sharp black scale
  • New flexible shock mount resists any damage to the gauge
  • Fine red pointer gives precise indication
  • Smaller, lighter and easily portable
  • Fitted with your choice of Velcro or Ambidex cuff
  • Tough bright white ABS construction with built in carrying handle
  • Lightweight ABS cuff container which is very easy to clean
.
Features: 1. The device is DC high frequency portable dental unit, small, light and nearly no radiation. 2. There are manual buttons installed on the surface of shell, operate easily, all of components are installed in the central PC board, insulation vacuum and sealed stereotype protection make its brilliant features. 3. The unit is mainly suitable for oral pre-treatment diagnosis of internal organisation structure and root depth and so on. It is indispensable in clinics especially for implant surgery. 4. The battery is durable, it can take about 5 hundred images after fully charged. 5. It can be connected with intra-oral digital X-ray imaging system. 6. 3 Colors Specifications:
Tube Voltage 60kV
Tube current 1MA
Exposure Time 0.02~2S
Tube Focus 0.3*0.3mm
Frequency 30kHz
Battery DC14.8V 6400mA
Rated Power 60VA
Charger Input AC100V-240V± 10%
Charger Output DC16.8V
Gross weight 3.5KG
Package size 220*240*275
The distance from skin to cone 130mm
Product Description:
  1. The microprocessor-controlled timer brings high-tech X-ray imaging at your fingertips.
  2. The control panel allows an accurate and fast exposure time selection while protecting the head during X-ray examinations.
  3. Fitted with 70KV 8mA tube with preheating grid, the machine has been specially designed for intraoral dental diagnosis applications.
Technical Specification: Tube voltage: 60kVp Tube current: 8mA Focus size: 1.5mm Total filtration:  2.5mmAL Exposure time:  0.2 - 4sec Leak Radiation: Outside one meter ≤ 0.002mGy/h Power supply: AC 220V±10%, 50Hz,1KVA

Features

Panoramic Imaging - By choosing a sensor, which improves the image quality while keeping radiation exposure to a minimum, Genoray has shown that it puts patient’s safety first. Cephalometric Imaging - When compared to the standard scanning method, PAPAYA PLUS has the shortest scan time out there   - Among patient discomfort, image's swing, and distortion, they are reduced along with the short scan time.  Tomography Imaging (Optional) PAPAYA PLUS added Tomography function and without hardware upgrade and considering of manufacturing of Tomography function; in addition to S/W, PAPAYA provides Tomography image.  High Resolution Cephalometric Technology It is enough only 4 second for scanning cephalo image on fast mode.   This reduces motion artifacts.  The Different Detector Types High-Definition images distinguish themselves from the old indirect conversion type of a CCD sensor. This should be the only way you view images  User Friendly Face to face positioning / Fit each individual’s jaw shape. / Voice support system / Hand switch / Emergency switch / Wheelchair accessible  Multi-Focus Function Multi-focus function ables to overcome operator's mistake from patient's faulty positioning and re-exposuring X-ray. By reconstructing image with software way, the panoramic images layer can be corrected by multi-focus function.  Exposure Programs Lateral, AP, PA, Water’s view, Submento vertex, and carpus.  
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare