BUFFERED FORMALIN 10% UNTINTED

$0.00

Shipped From Abroad

Available in 500mL 2Litre and 20L

Contains Formaldehyde 3.6% and phosphate buffer to pH 7.

Actions Buffered Formalin 10% has preservative properties.

Indications Buffered Formalin 10% is used for the preservation of pathological specimens but is not suitable for preserving urine for subsequent examination.

Precautions Not to be taken.

Description

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF103356013099-22
Brands:: PharmAust

Description

Product Description

Contains Formaldehyde 3.6% and phosphate buffer to pH 7.

Actions Buffered Formalin 10% has preservative properties.

Indications Buffered Formalin 10% is used for the preservation of pathological specimens but is not suitable for preserving urine for subsequent examination.

Precautions Not to be taken.

Safety Directions Avoid contact with eyes and skin. Avoid breathing vapour.

Adverse Effects Repeated contact with formaldehyde solutions may induce contact dermatitis. Ingestion results in pain, inflammation, ulceration and necrosis of the mucous membranes.

Directions for Use  Use as indicated in the appropriate preservation techniques.

Poisoning For advice, contact a Poisons Information Centre (Australia 13 11 26) or a doctor. If swallowed, do not induce vomiting; give water, milk or charcoal. If in eyes, hold eyelids apart and flush the eye with continuously running water. Continue flushing until advised to stop by the Poisons Information Centre or doctor, or for at least 15 minutes. If skin or hair contact occurs, remove contaminated clothing and flush skin and hair with running water. If inhaled, remove from contaminated area. Apply artificial respiration if not breathing.

Storage Store above 15oC and below 30oC. Store out of direct sunlight.

Poison Schedule Classified as a Poison (Schedule 6) using the criteria in the Standard Uniform Schedule for Medicines and Poisons

Available in 500mL 2Litre and 20L

Reviews

There are no reviews yet.

Be the first to review “BUFFERED FORMALIN 10% UNTINTED”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsBUFFERED FORMALIN 10% UNTINTED removeErma B-111 Bilirubin Meter removeZenithlab (IB-9025A) Laboratory Incubator removeAvalun LabPad Device removeDiscover 5 Panel Cup with Adulterants Per Pack removeAGD Erma EL-120 ELectrolyte Analyzer remove
NameBUFFERED FORMALIN 10% UNTINTED removeErma B-111 Bilirubin Meter removeZenithlab (IB-9025A) Laboratory Incubator removeAvalun LabPad Device removeDiscover 5 Panel Cup with Adulterants Per Pack removeAGD Erma EL-120 ELectrolyte Analyzer remove
ImageAvalun Labpad machineDrug Test Cup
SKUSF103356013099-22SF1033560084-6SF1033560084-109SF1033560084-65SF1033560084-23SF1033560084-125
Rating
Price

$0.00

$715.00

$350.00

$0.00

$0.00

$1,320.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad Available in 500mL 2Litre and 20L Contains Formaldehyde 3.6% and phosphate buffer to pH 7. Actions Buffered Formalin 10% has preservative properties. Indications Buffered Formalin 10% is used for the preservation of pathological specimens but is not suitable for preserving urine for subsequent examination. Precautions Not to be taken. Description
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Aboard  The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Microprocessor control.
  • Digital display setting and actual temperature.
  • Over temperature alarm, PID self-tuning.
  • Digital display running timer.
  • Stainless steel interior.
  • Electricity leakage protection.
  • With glass inner door, With hidden door locks.
  • Mechanical overheat protection, cut off the heating sources.
  • Automatic alarm after operation.
  • Suitable for constant temperature tests.
  • Suitable for bacteria cultivation, breeding, ferment.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self-contained and the entire cup is tamper resistant. Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Product Description
Contains Formaldehyde 3.6% and phosphate buffer to pH 7. Actions Buffered Formalin 10% has preservative properties. Indications Buffered Formalin 10% is used for the preservation of pathological specimens but is not suitable for preserving urine for subsequent examination. Precautions Not to be taken. Safety Directions Avoid contact with eyes and skin. Avoid breathing vapour. Adverse Effects Repeated contact with formaldehyde solutions may induce contact dermatitis. Ingestion results in pain, inflammation, ulceration and necrosis of the mucous membranes. Directions for Use  Use as indicated in the appropriate preservation techniques. Poisoning For advice, contact a Poisons Information Centre (Australia 13 11 26) or a doctor. If swallowed, do not induce vomiting; give water, milk or charcoal. If in eyes, hold eyelids apart and flush the eye with continuously running water. Continue flushing until advised to stop by the Poisons Information Centre or doctor, or for at least 15 minutes. If skin or hair contact occurs, remove contaminated clothing and flush skin and hair with running water. If inhaled, remove from contaminated area. Apply artificial respiration if not breathing. Storage Store above 15oC and below 30oC. Store out of direct sunlight. Poison Schedule Classified as a Poison (Schedule 6) using the criteria in the Standard Uniform Schedule for Medicines and Poisons Available in 500mL 2Litre and 20L
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin. Feature
  • Auto zero function: Manual blanking not required
  • Dual wavelength measurement system:
  • 2 wave lengths 455nm and 575nm
  • Plays major role to remove the interference caused due to Hemolysis & turbidity of sample
  • LED Light source:
  • LED does not require replacement as it lasts longer
  • As compared to Lamp, LED are more suitable as there is no intensity fluctuations
  • No warm up time required.
  • Flexible unit selection:
  • Two units either mg/dl or umol/L are selectable, ease of reporting
  • Compact slot for Capillary:
  • Accuracy of results are directly related to proper alignment of Capillary
  • B-111 has the easiest mode to ensure precise values
  • Data transfer:
  • External device can be connected to instrument through RS232 por
  • USB port
Technical Specification
  • Light source - LED
  • Wavelength - 455nm and 575nm
  • Net weight - 1kg
  • Measuring range - 0-30 mg/dl , 510 umol/L
  • Display - 16×2 LCD module with backlight
  • Auto calibration - Yes
  • Sample type - Serum or plasma
  • Sample volume - 40-80μL
  • Test time - <5sec
  • Units - mg/dl or umol/L
  • Dimensions - 150 (W) × 115 (H) × 190 (D) mm
  • Interface - RS232
  • Reading cuvette - Heparinized micro capillary holder
  • Storage temperature - 15-40°c
  • Power supply - DC 9V(DC adapter)
  • Power consumption - <2W
Features:
  • Microprocessor control.
  • Digital display setting and actual temperature.
  • Over temperature alarm, PID self-tuning.
  • Digital display running timer.
  • Stainless steel interior.
  • Electricity leakage protection.
  • With glass inner door, With hidden door locks.
  • Mechanical overheat protection, cut off the heating sources.
  • Automatic alarm after operation.
  • Suitable for constant temperature tests.
  • Suitable for bacteria cultivation, breeding, ferment.
  Technical Specification: Model: IB-9025A Working size: 250x250x250mm/9.84x9.84x9.84inch Power: 150W Temperature range: Room temperature+5~65℃ Temperature resolution: 0.1℃ Temperature fluctuation: ±0.5℃ Timer: 0-9999min Voltage: 110V 60Hz / 220V 50Hz Dimension: 380x370x580mm/14.96x14.57x22.83inch Size: 52cm*46cm*75cm / 20.5in*18.2in*29.6in Gross Weight:42kg / 93lb Net Weight: 23kg / 51lb Warranty: 1 year
The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes.
  • User-friendly: the LabPad® INR is designed to be easy to use especially thanks to its 3D-shaped microcuvette that only requires a small drop of blood from a fingertip. Thanks to the color screen, both measurement steps and browsing the list of results are easy to visualize.
  • Quick and reliable: the reliability of INR results is obtained by quality controls that are performed automatically before each measurement. In less than one minute, you can see if you are in your therapeutic range.
  • Connected: the result obtained after performing the test can be transferred to healthcare professionals in charge of your treatment monitoring. This result is complementary to the pie charts and trend reports directly displayed on the LabPad® INR to help you monitoring your treatment
 
Click Here To Download Catalogue
   
All-in-One Design
FDA 510K & CLIA Waived 99% Accurate Results in as little as 1 minute 24 Month Shelf Life from Date of Manufacture Secure, seal and send to lab for confirmation Built in temperature strip Available to test up to 14 substances Adulterants available
 
 
Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface. Features:
  • Parameters: Na+,K+,Cl-, iCa++ / Li
  • It works on ISE principle
  • Sample Type: Whole blood, Serum, Plasma, Urine
  • Low reagent consumption
  • Sample requirement is only 90ul
  • 60 samples per hour
  • Automatic two point calibration after 4hrs and one point calibration with each sample analysis
  • Air bubble detection
  • Track reagents consumption and provides alerts
  • For low reagent volume
  • Precision testing facility to get CV and SD
  • Trilevel Quality Control with LJ plots of last 30days
  • Low aspiration volume
  • Fast sample processing
  • Accurate and Precise results
Technical Specifications:
Parameters Na+, K+, Cl– /Ca++
Principle Ion Selective Electrode (ISE)
Sample Type Analyses whole blood, serum, plasma and urine
Sample Volume ≤100 µL
Analysis Time ≤60 seconds
Throughout ≤60 samples per hour
Data Link Serial (RS232)
External Interface USB (Keyboard, Mouse)
Operating Condition 10° C to 35° C, Relative Humidity up to 85%
Storage Condition Temp: 10° C to 40° C
Relative Humidity up to 85% non- condensing
Power Supply 100 to 240 VAC ±10%, 50Hz
Dimensions 395 x 260 x 375 mm
Weight 7.5 kg
 
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar