Capnograph and Oximeter CapnoVet3
$0.00
Shipped From Abroad
Pet-specific capnography monitors are widely used in veterinary clinical and pet care. It can be used for anesthesia monitoring during pet surgery, respiratory status monitoring during postoperative recovery, and management of chronic respiratory diseases.
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
Features of Kingst Handheld Capnograph and Oximeter CapnoVet3
- Designed for pets – The device is optimized for pets of different species and sizes, ensuring measurement accuracy and comfort.
- High-precision sensor – Equipped with advanced sensor technology to provide fast and reliable carbon dioxide monitoring.
- Easy to operate – The design is simple and easy for veterinarians and pet caregivers to use, reducing learning costs.
- Strong durability – The equipment is sturdy and durable and can be used for a long time in a variety of environments to meet daily and emergency monitoring needs.
- Real-time data – Provide real-time respiratory waveform and carbon dioxide concentration data to help make timely diagnosis and treatment decisions.
Specifications of Kingst Handle Capnograph and Oximeter CapnoVet3
AC Input | 100V – 240V, 50Hz/60 Hz to 5VDC Adapter with 5V type-CUSB adapter Cable. Optional Vehicle 12V to 5V Type-CUSB Charger Lead. |
Battery | Built-in rechargeable lithium battery pack (3.7V, 3500mAH) |
Temperature | 5 to +40 ℃ |
Humidity | 30-75% |
Atmospheric pressure | 86~106kpa |
EtCO2/FiCO2 Range | 0~150mmHg |
Accuracy | ±2mmHg for CO2 range 0 – 40mmHg; ±5% for CO2 range from 41 – 70mmHg; ±8% for CO2 range from 71 – 100mmHg; Over 100mmHg ±10% |
Respiration Rate Range | 3~150 breaths/minute |
Accuracy | ±1% of reading or ±1 rpm whichever is greater |
Size | 72 x 155 x 40mm (W x H x D) |
Weight | Weight on Airway ETT/LMA<25g. Monitor 380g |
Display size | 2.8 inches |
Application Scenarios of Kingst Handheld Capnograph and Oximeter CapnoVet3
- Anesthesia Monitoring During Surgery:
During pet surgeries, precise management of anesthesia is crucial for ensuring the success of the procedure and the safety
of the pet. An end-tidal CO2 monitor can provide real-time monitoring of the pet’s CO2 levels, helping veterinarians assess
ventilation status and the effectiveness of anesthesia. If CO2 levels rise or fall abnormally, veterinarians can promptly adjust
the anesthesia dosage to keep the pet in a safe anesthetic state.
- Postoperative Recovery Monitoring:
The postoperative recovery period is critical for pets after anesthesia. An end-tidal CO2 monitor can continuously track the
pet’s respiratory status, offering real-time respiratory waveforms and CO2 level data. By monitoring respiratory function,
veterinarians can quickly identify and address potential complications such as respiratory depression or hypoventilation,
enhancing the safety of postoperative recovery.
- Management of Chronic Respiratory Diseases:
For pets with chronic respiratory diseases like asthma or chronic bronchitis, an end-tidal CO2 monitor helps veterinarians
and pet owners continuously monitor respiratory function. Regular recording and analysis of CO2 levels and respiratory
waveforms allow veterinarians to better assess disease progression and treatment efficacy, and adjust treatment plans promptly.
- Emergency Care and Intensive Monitoring:
In emergency and intensive care settings, a pet-specific end-tidal CO2 monitor provides quick respiratory function
information. For emergencies such as respiratory failure or choking, the monitor helps veterinarians rapidly assess the
pet’s respiratory condition and take effective emergency measures, potentially saving the pet’s life.
- Routine Checkups and Health Monitoring:
During routine checkups, an end-tidal CO2 monitor can be used to assess the overall health status of pets.
By measuring and recording respiratory data, veterinarians can detect potential respiratory issues early and
recommend further examination or treatment
- Rehabilitation Training and Exercise Evaluation:
For pets undergoing rehabilitation training or exercise evaluation, an end-tidal CO2 monitor helps assess changes
in respiratory function during activity and recovery. By monitoring CO2 levels and respiratory waveforms, veterinarians
and pet rehabilitation specialists can develop personalized rehabilitation plans, ensuring that pets train within safe limits.
Quick Comparison
Settings | Capnograph and Oximeter CapnoVet3 remove | Siare Morpheus LT Anaesthetic Machine remove | Hersill Genesis Anaesthetic Machine remove | Spinal Epidural Pack remove | Render SD-M2000A Anesthetic Machine remove | Anesthetic Face Mask remove | ||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | Capnograph and Oximeter CapnoVet3 remove | Siare Morpheus LT Anaesthetic Machine remove | Hersill Genesis Anaesthetic Machine remove | Spinal Epidural Pack remove | Render SD-M2000A Anesthetic Machine remove | Anesthetic Face Mask remove | ||||||||||||||||||||||||
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||||||||||||||||||||
SKU | SF1033560101- 3 | SF1033560450-1 | SF1033560084-25 | SF1033560011-13 | SF1033560084-141 | |||||||||||||||||||||||||
Rating | ||||||||||||||||||||||||||||||
Price |
|
|
|
| $1,870.00 | $8.00 | ||||||||||||||||||||||||
Stock | ||||||||||||||||||||||||||||||
Availability | ||||||||||||||||||||||||||||||
Add to cart | ||||||||||||||||||||||||||||||
Description | Shipped From Abroad
Pet-specific capnography monitors are widely used in veterinary clinical and pet care. It can be used for anesthesia monitoring during pet surgery, respiratory status monitoring during postoperative recovery, and management of chronic respiratory diseases.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from Abroad he Morpheus LT is an anesthetic machine suitable for treatment of adults, children and new-borns. lt is provided with a mechanical 3-gas flowmeters group and a group tor rapid connection of two vaporizers in line and it is supplied with an advanced manual ventilation system, APL system, or AUX system with traditional To-and-Fro valve switched on and off automatically by ventilator. The unit frame is made tor 30% of light alloy and for 70% of fullyrecyclable plastic materiai. Thanks to the materiai used, the Morpheus has a total weight of less than 80 kgs. Delivery & Availability: Typically 15 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from Abroad The Genesis anaesthesia workstations meet your most ambitious requirements. They stand out for their lung protective ventilation. Application Field: Neonates, Pediatrics & Adults Ventilation Modes: Volume controlled (VC), Pressure controlled (PC), Adaptive Pressure with Volume Guaranteed (APVG) & Pressure Support Ventilation (PSV) Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In Stock
It is for performing spinal/epidural or combined spinal/epidural or never-block loco-regional anaesthesia on patinet in clinical surgery.
Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from Abroad
| In stock
Four sizes from small adult to extra large adult. A range of color-coded economy anesthetic face masks for single patient use to prevent the possibility of cross infection.
| ||||||||||||||||||||||||
Content | Features of Kingst Handheld Capnograph and Oximeter CapnoVet3
Specifications of Kingst Handle Capnograph and Oximeter CapnoVet3
Application Scenarios of Kingst Handheld Capnograph and Oximeter CapnoVet3
| The Morpheus LT is an anesthetic machine suitable for treatment of adults, children and new-borns. lt is provided with a mechanical 3-gas flowmeters group and a group tor rapid connection of two vaporizers in line and it is supplied with an advanced manual ventilation system, APL system, or AUX system with traditional To-and-Fro valve switched on and off automatically by ventilator. The unit frame is made tor 30% of light alloy and for 70% of fullyrecyclable plastic materiai. Thanks to the materiai used, the Morpheus has a total weight of less than 80 kgs.
LUNG VENTILATOR
The ventilator works by a microprocessor electronic control system with a simple and intuitive interface, which allows the anesthetist to operate in a clear and safe way. The system is provided with 3 dedicated software to have automatically the default settings for adult and paediatric patients and new-borns. lt is provided with the automatic compensation of dead space, the leakages calculation and the automatic calibration of Fi02.
Operative Modes:
MAN
VC-VC
PCV-APCV
APCV
P -SIMV
V- SIMV
Measured parameters:
PAW
RATE
VM - VTE
T INSP
Fi02
MANUAL VENTILATION SYSTEM
The Morpheus is equipped with an advanced manual ventilation system that can be switched on and off automatically by the ventilator; the operator can select the APL system or the AUX system with traditional T-and-Fro valve and 02 by pass safety system.
BREATHING SYSTEM
The patient group of Morpheus LT is compact, lightweight for manual removal and fully autoclavable. The patient circuit group is supplied with an automatic heating system avoiding humidity with possibility to use reusable and rechargeable CO, absorbers (TOP SPECIAL) of 1 kg. Absorber is with quick-release enabling replacement also during anaesthesia. The group is supplied with an exposed bellow that can be manually inspected. The MorpheusLT is equipped with 3 wide and large drawers and a large work-shelf to facilitate operating rooms procedures.
Click Here To Download Catalogue | The Genesis anaesthesia workstations meet your most ambitious requirements. They stand out for their lung protective ventilation, accuracy and performance, cost saving, design and ergonomics, safety and versatility.
TECHNICAL SPECIFICATION
OPERATING DATA
Click Here To Download Catalogue | It is for performing spinal/epidural or combined spinal/epidural or never-block loco-regional anaesthesia on patinet in clinical surgery.
Component:
|
Click Here To Download Catalogue | Four sizes from small adult to extra large adult. A range of color-coded economy anesthetic face masks for single patient use to prevent the possibility of cross infection.
Features:
| ||||||||||||||||||||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||
Additional information |
Reviews
There are no reviews yet.