Capnograph and Oximeter KMI605A

$759.00

Shipped From Abroad

A tabletop carbon dioxide monitor that can be fixed or mobile. High accuracy and stable performance. It can be used in emergency, operating room, intensive care unit (ICU), intubation position monitoring, etc.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130170-5
Brands:: Kingst

Description

Features of Kingst Desktop Capnograph and Oximeter Monitor KMI605A
  • It Can Be Tested Immediately After Startup Without Zero Calibration

Atmospheric pressure automatic compensation, whether plateau or helicopter rescue, can provide accurate monitoring.

  • Simple Maintenance

Sturdy structure, suitable for various harsh environments

  • The Lithium Battery Can Work Continuously For More Than 12 Hours At Full Load

Nice price consumables, the dehydrator can work continuously for a long time.

 

Specifications of Kingst Desktop Capnography Monitor KMI605A
AC Input 220V,50Hz,12V/1.8AH
Environmental temperature 5~40℃
Relative humidity 30~75%(Non-condensing)
Atmospheric pressure 86~106kpa
Co2 Measuring Range 0~150mmHg
Accuracy 0~40mmHg, inaccuracy≤± 2mmHg;
41~70mmHg, inaccuracy≤±5% of Reading;
70~100mmHg, inaccuracy≤± 8% of Reading;
101~150mmHg, inaccuracy≤±10% of Reading
Respiration Rate 3~150t/min
Monitoring Inaccuracy the bigger value of ±1% or ±1 t/min
Gas sampling flow 50~250cc/min (Optional)
SpO2 monitoring range 50~100% (KMI605B without SpO2)
Accuracy For 70%~100%, inaccuracy≤± 2%,
When ≤70%, not required
Monitoring range of Pulse rate 30~250bpm (KMI605B without PR)
Application Scenarios OF Kingst Desktop Capnography Monitor KMI605A
  • Responsive and easy to operate

KMI605A/B is a tabletop accurate capnograph, it can measure EtCO2 waveform and value immediately after power on, and no need for zero calibration. At the same time, it has the atmospheric pressure compensation, so that KMI605A/B can well adapt to harsh environments such as plateaus or helicopter rescue.

  • Sturdy and easy to maintain

The housing is sturdy and durable and can be used in a variety of harsh environments. Its maintenance and upgrades are very simple.

  • Long continuous working time
  • Two modes are available 

Mainstream and Side Stream. Different modes can be selected according to different scenarios.

Reviews

There are no reviews yet.

Be the first to review “Capnograph and Oximeter KMI605A”

Your email address will not be published. Required fields are marked *

Quick Comparison

Capnograph and Oximeter KMI605A removeRender SD-M2000B Anesthetic Machine removeOxygen Concentrator 3Ltr. removeElastomeric Pump (Disposable Infusion Pump) with PCA removeSpinal Epidural Pack removeMediPlus Bain Circuit (Adult) remove
NameCapnograph and Oximeter KMI605A removeRender SD-M2000B Anesthetic Machine removeOxygen Concentrator 3Ltr. removeElastomeric Pump (Disposable Infusion Pump) with PCA removeSpinal Epidural Pack removeMediPlus Bain Circuit (Adult) remove
Image
SKUSF1033560130170-5SF1033560011-10SF1033560084-40SF1033560084-18SF1033560084-25SF1033560084-21
Rating
Price

$759.00

$4,840.00

$273.00

$0.00

$0.00

$28.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad A tabletop carbon dioxide monitor that can be fixed or mobile. High accuracy and stable performance. It can be used in emergency, operating room, intensive care unit (ICU), intubation position monitoring, etc.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad
  • Contains Output interface for Anesthesia information management system.
  • Complete with backup battery for working more than 30 minutes.
Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Customized: Customized
Certification: CE, FDA, ISO13485
Scale: Medium
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock This product make the tension of silicon capsule as the driving force to control the flow by micro porous tube, it was pre-selected by doctor base on patients'situation, and then and then handed over to the patients ' self- management “to relieve or ease the pain

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock It is for performing spinal/epidural or combined spinal/epidural or never-block loco-regional anaesthesia on patinet in clinical surgery.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock
  • Provided with 22mm Corrugated tube of length 1.6m
  • APL Valve
  • 2 L Antistatic Rebreathing bag
  • 6mm Green PVC tube of length 1.6m
Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Content
Features of Kingst Desktop Capnograph and Oximeter Monitor KMI605A
  • It Can Be Tested Immediately After Startup Without Zero Calibration
Atmospheric pressure automatic compensation, whether plateau or helicopter rescue, can provide accurate monitoring.
  • Simple Maintenance
Sturdy structure, suitable for various harsh environments
  • The Lithium Battery Can Work Continuously For More Than 12 Hours At Full Load
Nice price consumables, the dehydrator can work continuously for a long time.  
Specifications of Kingst Desktop Capnography Monitor KMI605A
AC Input 220V,50Hz,12V/1.8AH
Environmental temperature 5~40℃
Relative humidity 30~75%(Non-condensing)
Atmospheric pressure 86~106kpa
Co2 Measuring Range 0~150mmHg
Accuracy 0~40mmHg, inaccuracy≤± 2mmHg; 41~70mmHg, inaccuracy≤±5% of Reading; 70~100mmHg, inaccuracy≤± 8% of Reading; 101~150mmHg, inaccuracy≤±10% of Reading
Respiration Rate 3~150t/min
Monitoring Inaccuracy the bigger value of ±1% or ±1 t/min
Gas sampling flow 50~250cc/min (Optional)
SpO2 monitoring range 50~100% (KMI605B without SpO2)
Accuracy For 70%~100%, inaccuracy≤± 2%, When ≤70%, not required
Monitoring range of Pulse rate 30~250bpm (KMI605B without PR)
Application Scenarios OF Kingst Desktop Capnography Monitor KMI605A
  • Responsive and easy to operate
KMI605A/B is a tabletop accurate capnograph, it can measure EtCO2 waveform and value immediately after power on, and no need for zero calibration. At the same time, it has the atmospheric pressure compensation, so that KMI605A/B can well adapt to harsh environments such as plateaus or helicopter rescue.
  • Sturdy and easy to maintain
The housing is sturdy and durable and can be used in a variety of harsh environments. Its maintenance and upgrades are very simple.
  • Long continuous working time
  • Two modes are available 
Mainstream and Side Stream. Different modes can be selected according to different scenarios.
Features:
  • Contains Output interface for Anesthesia information management system.
  • Complete with backup battery for working more than 30 minutes.
  Technical Specifications:
Model: SD-M2000B
Brand: RENDER
Origin: Made In China
Category: Electronics & Electricity / Electronic Instrument / Electricity Meter & Instrument
Label: anesthesia machine , anesthesia ventilator , anesthesia machine
 
Click Here To Download Catalogue
 
Our anesthesia system is a precision crafted, life-sustaining device. When moving to an O2 concentrator from tanks, you should expect the same attention to detail. A full 8lpm O2 flowrate capability - gives better performance at lower flow rates 20psi pressure output - your anesthesia system was designed to work from pressure O2 concentrations average 93% +/- 3% Built-in Low O2 Concentration Alarm Small footprint of 15"x15"x22" Remarkably quiet Save money over time vs. tanks Eliminate contamination hazards of tanks coming and going in your facility Works with ALL manufacturer's brands of anesthesia systems
    • .
   
This product make the tension of silicon capsule as the driving force to control the flow by micro porous tube, it was pre-selected by doctor base on patients'situation, and then and then handed over to the patients ' self- management “to relieve or ease the pain Product Components: one-way valve medicated device, elastic liquid storage device, liquid medicine filter, current limiting device, automatic liquid feeding device ( CBI & PCA ), pipe and the external connector; Product Features: 1. The continued to liquid (CBI) make the drug-stored sac mechanical stretch as a driving force, limited the flow through the micro porous tube to the patient safely, effectively, slightly, continuous uniform injection of liquid to analgesic effect; extrusion pump body does not affect the liquid normal velocity; liquid filtering device which can control the particles enter the body better; 2. Continued to liquid + self control to liquid ( CBI+PCA ) make the drug-stored sac mechanical stretch as a driving force, limited the flow through the micro porous tube to the patient safely, effectively, slightly, continuous uniform injection of liquid to analgesic effect; Automatic medicated function is the patients can medicate according to pain independently. Extrusion pump body does not affect the liquid normal velocity; liquid filtering device which can control the particles enter the body better; How to use: 1. Get analgesia pump out from sterile packaging, removing the cap of medicine inlet and outlet; pour the analgesic liquid in the liquid storage device, draw out the air from the liquid storage. 2. Finish medicating, waiting for the liquid outflow from the medicine outlet; please clamp tightly to stop flowing for preparation. 3. Control keys (PCA key) is a function key to add the medicine base on continue to medicated by patients' self-controlled. So the patients can self-control the PCA key under the guidance of doctors, according to the needs while they are in treatment. At the same time, doctor should fill in PCA treatment card, so that they can analyze the condition from PCA additional times.It is for performing spinal/epidural or combined spinal/epidural or never-block loco-regional anaesthesia on patinet in clinical surgery. Component:
  • Epidural needle 16G,
  • Epidural catheter,
  • Epidural filter 0.2 um,
  • Catheter connector,
  • LOR syringe
  • Provided with 22mm Corrugated tube of length 1.6m
  • APL Valve
  • 2 L Antistatic Rebreathing bag
  • 6mm Green PVC tube of length 1.6m
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare