Description | Shipped From Abroad
Oval Plate, 23×16mm
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from abroad
- Digital Slit lamp system,Galilean optical system,Five magnifications.
- Independent image process and management software system
- More than 10 million pixel image resolution
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from abroad
- Light rack with integral casting, CNC machining, the measuring system is more stable, good consistency.
- Color LCD display, 5.7 inches man-machine interface is more comfortable.
- PD automatic measurement function, automatically PD value.
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| In Stock
Features:
●Professional
Same ear wax removal tool as those used by doctors, you can easily eliminate ear wax buildup at home, really save your money and time on medical visiting. Safe and Environmentally Friendly.
●Quick & Easy
This ear wax removal kit is a quick, effective treatment for excess ear wax buildup. Fill the bottle with solution, Twist on the disposable tip, Use the trigger handle to spray solution into the ear canal. So Easy.
Delivery & Availability:
Typically 7-14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from abroad
This ultra-portable is an excellent diagnostic instrument for the examination of anterior segment structures and ocular abnormalities.
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from abroad
The NJC-4 Lensmeter is used to measure the diopters of spherical lens and cylinder lens, the axis of cylinder lens, the strength and the baseline direction of shuttle lens, it can also stamp the optical center of lens, the axis of cylinder len and the base direction of shuttle lens.
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
|
Content | | Slit Lamp with Workstation Features:
- Digital Slit lamp system, Galilean optical system, Five magnifications
- Independent image process and management software system
- More than 10 million pixel image resolution
Technical Specifications:
Microscope Type |
Galileo Parallel |
Digital System |
External Digital Slit Lamp with 10 Mega pixels |
Magnification Change Way |
Drum Five Magnifications |
Eyepiece Magnification |
12.5x |
Total Magnifications |
6x, 10x, 16x, 25x,40x |
Diopter Adjustment |
-5D ~+5D |
Slit Width |
0-14MM Continuous |
Slit Height |
1-14MM Continuous |
Slit Angle |
0°- 180° Adjustable |
Slit Inclination Angle |
5°,10°,15°, 20° |
Light Spot Diameter |
0.2mm, 2mm, 3mm, 5mm, 10mm, 14mm |
Filter |
Heat Absorption; Grey; Red free; Cobalt Blue |
Fixation |
Red LED |
Illumination Bulb |
12V/50W German OSRAM Halogen Tungsten Lamp |
| Features:
- Using the ARM processor and the latest domestic image processing, the system is fast and the image is clear.
- Japan’s mature optical path system, humanized automatic mist measurement process, to reduce the error caused by adjustment, more precise measurements.
- Light rack with integral casting, CNC machining, the measuring system is more stable, good consistency.
- Color LCD display, 5.7 inches man-machine interface is more comfortable.
- PD automatic measurement function, automatically PD value.
- One key lock function, quickly locking mobile platforms.
- Innovative designs, according to the structure of human body engineering, to bring customers good aesthetic feeling and comfortable.
- Data transmission with CV7200, improved efficiency of online 5x magnification options, respond to different viewing needs.
Technical Specifications:
Measurement Range
Vertex distance.......................................0.0,12.0,13.75,15mm
Sphere.......................................-20D~+20D(0.12/0.25D step)
Cylinder...........................................0~±10D(0.12/0.25D step)
Axis...............................................................1~180°(1° step)
PD distance............................................................30~85mm
PD..........................................................................10~86mm
Minimum pupil diameter..............................................Ø2.0mm
Target................................................automatic fogging target
Hardware specifications
Monitor.............................................................5.7" color LCD
Printer......................................................Fast thermal printer
Power saving function....................OFF, 5/15 mins (selectable)
Power supply................................AC110~220V, 60/50Hz, 50W
Dimension/weight..............................288x500x480mm(14kgs) | Features:
●Professional
Same ear wax removal tool as those used by doctors, you can easily eliminate ear wax buildup at home, really save your money and time on medical visiting. Safe and Environmentally Friendly.
●Quick & Easy
This ear wax removal kit is a quick, effective treatment for excess ear wax buildup. Fill the bottle with solution, Twist on the disposable tip, Use the trigger handle to spray solution into the ear canal. So Easy.
●Standard
Capacity of the ear cleaner solution bottle is 10.6Oz, it has the most suitable size to hold in hand. Working at condition 32-122℉(0-50℃). Recommend to fill 1/5 of the bottle with OTC hydrogen peroxide, and 4/5 with very warm water.
●Complete Ear Washer System
Our earwax removal kit comes with 1× Ear Washer Bottle, 1× Wash Basin, 1× Rubber Bulb, 1× Short Injection Head, 1× Long Hose Injection Head, 5× Disposable Tip, 1× User Manual. | Features:
- Ultra-portable: This ultra-portable is an excellent diagnostic instrument for the examination of anterior segment structures and ocular abnormalities. Its easy-to-operate optical system produces a high-brightness, continuously adjustable slit image ideal for pediatric and geriatric setting, emergency department screenings, ward rounds, beside examination, post-op evaluations, and mission work;
- LED illumination: the first and the only portable slit lamp in the world applying LED illumination system. The most prominent advantage of our LED illumination system gives the examiner the clearest image without glare;
- Comfortable using experience: The low heat radiation from our LED lamp makes the most comfortable examine experience for the patient;
- Sharpest Slit: With the blade imaging system S150 gives equally sharpest slit as the best classic slit lamp in the world;
- No need to replace illumination lamp: The LED lamp used in S150 portable slit lamp is rated 20,000 hours at full power. Its lifetime is almost 10 times longer than a normal halogen lamp;
- Power-saving: S150 can work for long hours without changing batteries.
Technical Specifications:
- Magnification: 5x
- Range of slit length: 5mm~11mm
- Minimum slit width: 0.2mm
- Working distance: 12~32mm
- Power supply: AA batteries x 2
- Illumination: LED blub(3.3V/1W)
- Battery life: More than 3h(AA alkaline batteries x 2)
- Net weight: 150g(without batteries)
How to Operate:
- Press the Power Switch to turn the slit lamp on/off
- Loosen the Locking Screw
- Twist the Lamp Body while holding the Magnifier Bracket still till the slit is in the required angle
- Push or pull the Lamp Body while holding the Magnifier Bracket still to set the Magnifier into a position comfortable for observation
- Fasten the Locking Screw
- Pull the Lamp Head back and forth for adjusting the width and the length of the slit, as well as the intensity of the light
| The NJC-4 Lensmeter is used to measure the diopters of the spherical lens and cylinder lens, the axis of cylinder lens, the strength and the baseline direction of shuttle lens, it can also stamp the optical center of the lens, the axis of cylinder lens, and the base direction of shuttle lens. This instrument (Both Ac and Dc are permitted Two cells When Dc) has clear readings and graduations as well as high objective precision and reliabilities except that it can be operated easily and conveniently, AU the lenses and the made glasses can be measured by it, therefore, it is a required and ideal measuring instrument for glasses manufactures, glasses stores and ophthalmological hospitals.
Technical Specifications:
- Eyepiece focusing range: ±5D
- The top point diopter measuring range: 0—±20D
- The minimum measuring square value: 0.125D
- The shuttle lens measuring range: 5A
- The shuttle lens square value: 1A
- The cylinder lens axial range: 0—180°
- The cylinder lens axial square value: 5°
- The maximum diameter of the measured lenses l00m/m
- Power supply: AC 110V-6V DC 3V
- Note: This item is AC 110V; The battery is not included!
|
Reviews
There are no reviews yet.