Chalazion Forceps

$0.00

Shipped From Abroad

Oval Plate, 23×16mm

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF103356013094-32
Brands:: HASA-OPTIX

Reviews

There are no reviews yet.

Be the first to review “Chalazion Forceps”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsChalazion Forceps removeHandheld Digital Auto-refractometer removePortable Rebound Tonometer removePortable Fundus Camera removeApplanation Tonometer removeManual lensmeter remove
NameChalazion Forceps removeHandheld Digital Auto-refractometer removePortable Rebound Tonometer removePortable Fundus Camera removeApplanation Tonometer removeManual lensmeter remove
ImageMecan AutoSight MCE-900 Handheld Digital AutorefractometerMecan SW-500 Portable Rebound TonometerMecan MC-600 Portable Fundus CameraMecan Applanation Tonometer YZ30XMecan Manual lensmeter NJC-4
SKUSF103356013094-32SF1033560107-2SF1033560107-17SF1033560107-23SF1033560107-1SF1033560107-22
Rating
Price

$0.00

$0.00

$1,815.00

$2,310.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad Oval Plate, 23×16mm
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from abroad AutoSight 900 is a portable vision screener for patients at any age. Its working principle is the refraction of light.
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Shipped from abroad Tonometer SW-500 with vertical and horizontal two working modes, wireless output print data.
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
83Shipped from abroad This is a portable medical camera for fundus imaging, diagnosis, and especially for fundus disease screening. It's compact, easy to obtain high definition fundus image. It can be conveniently applied to rapid screening, out diagnosis, bedside diagnosis and remote medical treatment, etc.
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Shipped from abroad The product is designed on the principle basis of Goldman tonometer. It can be connected with slit lamp(Carl Zeiss type).
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Shipped from abroad The NJC-4 Lensmeter is used to measure the diopters of spherical lens and cylinder lens, the axis of cylinder lens, the strength and the baseline direction of shuttle lens, it can also stamp the optical center of lens, the axis of cylinder len and the base direction of shuttle lens.
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
ContentHandheld Digital Auto-refractometer(AutoSight 900) is a portable vision screener for patients at any age. Its working principle is the refraction of light. Optical rays are focused on a sensor after passing through the eye's refractive system. The spherical power, cylindrical power, and axis of both eyes can be obtained by digital signal processing. Features of Handheld Digital Auto-refractometer:
  • Quick: Automatic and convenient. Press the button at the working distance (35cm/14in) and that's it. The result will be automatically shown in 5 seconds.
  • Accurate: Objective measurement of diopter is obtained from optical signal. The result is not affected by various external factors.
  • Intelligent: Detects multiple eye problems in one measurement including myopia, hyperopia, astigmatism and anisometropia
Technical Specifications of Handheld Digital Auto-refractometer:
Item Range Interval Tolerance
Spherical (S) Myopia Mode -9.00D~ +2.50D 0.25D ±0.50D or ±20% (whichever is greater)
Normal Mode -6.00D  ~ +8.00D
Cylindrical(C) -3.00D~0.00D 0.25D ±0.50D or ±20% (whichever is greater)
Axis(A) 0°~180° ±5°
 
Tonometer SW-500 with vertical and horizontal two working modes, wireless output print data. The equipment is used to measure intraocular pressure, using the principle of:  the probe hits the surfaces of different hardness at a certain speed, has a different reaction when the probe rebounds. Be of advantages of high accuracy, portable, without anesthesia, without the cross-infection, etc. Features:
  • Measurement can go along both in standing and lying posture
  • Wireless data printing
  • Easy to learn, easy to use
  • Lightweight and handy
  • No anesthesia, avoiding discomfort reaction
Technical Specifications:
Performance Index:
Measuring Range : 3mmHg~70mmHg
Measuring Error: ±1.5mmHg(3mmHg≤intraocular pressure≤25mmHg)
±2.5mmHg(25mmHg<intraocular pressure≤70mmHg)
Environment Requirement:
Transport and Storage: Ambient temperature:-20℃~+55℃
Relative moisture:≦95%
Atmosphere pressure:500hPa~1060hPa
Running: Ambient temperature:+5℃~+40℃
Relative moisture:≦80%
Atmosphere pressure:700hPa~1060hPa
Rating voltage: DC3V(2 AA Batteries)
Rating input power:1VA
Portable Fundus Camera is a portable medical camera for fundus imaging, diagnosis, and especially for fundus disease screening. It's compact, easy to obtain high definition fundus image. It can be conveniently applied to rapid screening, out diagnosis, bedside diagnosis and remote medical treatment, etc. Features of Portable Fundus Camera:
  • Images real-time display, one-button magnifying
  • Non-mydriatic and high definition imaging.
  • Micro SD memory card up to 32GB for 80,000 images
  • USB and WiFi connection
  • Low weight 450g, movable and portable
  • A rechargeable battery provides up to more than 4 hours of continuous operation.
  • Optional imaging modules for examination: posterior ophthalmoscope, anterior segment ophthalmoscope, otoscope, rhinoscope, laryngoscope and dermatoscope
  • High definition and stable image
  • Easy one-handed operation and excellent portability
  • Large data service and a variety of image acquisition mode
Technical Specifications of Portable Fundus Camera:
Model MC-600
FOV 45°
Minimum pupil 2.5mm
Refractive compensation -20D~+20D
Light source White LED/IR
Image resolution 1920×1080
Focus Mode Manual
Screen 3.5" color
Power ≤6VA
Storage 8GB Micro SD card
Power supply 3.7VLithium Battery
Interface Mini USB/Wifi
N. Weight 450g(Typical)
G. Weight 2.5kg
Size 160mm*90mm*190mm
Packing size 360mm*310mm*160mm
Applanation Tonometer is designed on the principle basis of Goldman tonometer. It can be connected with slit lamp(Carl Zeiss type). Features of Applanation Tonometer:
  • When used with slit lamp, it can be used to examine the eyes and measure ocular pressure.
  • Accurate measurement and total tolerance are less than 0.066KPa(0.55Hg).
  • Directly get the ocular pressure and do not need to look up the conversion table.
  • The measured ocular pressure is not affected by hardness of eye.
  • The affected?ocular volume is just 0.56 cubic millimeter.
  • Adjustable measuring pressure ensures the long-term stability and reliability.
Technical Specifications Applanation Tonometer:
  • Measuring Range: 0~1064 Kpa
  • Light Ring Displacement: 1.53×2=3.06mm
  • Diameter of Prism Head: 7mm
  • Moving Range of Prism Head: 3mm
The NJC-4 Lensmeter is used to measure the diopters of the spherical lens and cylinder lens, the axis of cylinder lens, the strength and the baseline direction of shuttle lens, it can also stamp the optical center of the lens, the axis of cylinder lens, and the base direction of shuttle lens. This instrument (Both Ac and Dc are permitted Two cells When Dc) has clear readings and graduations as well as high objective precision and reliabilities except that it can be operated easily and conveniently, AU the lenses and the made glasses can be measured by it, therefore, it is a required and ideal measuring instrument for glasses manufactures, glasses stores and ophthalmological hospitals. Technical Specifications:
  • Eyepiece focusing range: ±5D
  • The top point diopter measuring range: 0—±20D
  • The minimum measuring square value: 0.125D
  • The shuttle lens measuring range: 5A
  • The shuttle lens square value: 1A
  • The cylinder lens axial range: 0—180°
  • The cylinder lens axial square value: 5°
  • The maximum diameter of the measured lenses l00m/m
  • Power supply: AC 110V-6V DC 3V
  • Note: This item is AC 110V; The battery is not included!
 
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare