Cleveland Open Cup Flash Point Tester PE-TVO
$0.00
Shipped From Abroad
Purpose:
The tester PE-TVO is intended for usage as laboratory equipment to perform open cup flash point determination of oil products according to method A ASTM D92 and GOST 4333-87.
Delivery & Availability:
Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
Purpose:
The tester PE-TVO is intended for usage as laboratory equipment to perform open cup flash point determination of oil products according to method A ASTM D92 and GOST 4333-87.
Technical specifications:
– Maximum heating temperature, °C – up to 370
– Power supply voltage from AC mains with frequency of 50Hz, V – 220±22
– Power consumption, no higher than, W – 1000
– Instrument weight, kg – 5
– Service life, years at least – 5
Operation conditions:
– Air temperature, °C – 15?35
– Relative humidity, % – 30?90
– Overall dimensions (body), mm:
– Length, mm – 330
– Width, mm – 250
– Height, mm – 165
– Range of flash point determination, °C – 25-370
– Ignition device, type – gas
– Control of electric heating power – electronic
– Automatic passage of burner above surface of sample at set speed
– Availability of gas network or cylinder (methane, propane/butane) is required
Scope of delivery:
1. The open cup flash point tester PE-TVO complete with cup – 1 pc.
2. Thermometer TH-2 according to GOST 400 – 1 pc.
3. Template for flame adjustment – 1 pc.
4. Operation manual- 1 pc.
5. Packaging crate – 1 pc.
Quick Comparison
Settings | Cleveland Open Cup Flash Point Tester PE-TVO remove | Skyla Hi POC Clinical Chemistry Analyzer remove | Hawksley 1400 Haematocrit Centrifuge remove | Eppendorf Minispin Centrifuge remove | Eppendorf Pipette Tip 20ul Per Pack remove | Zenithlab (IB-9025A) Laboratory Incubator remove | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | Cleveland Open Cup Flash Point Tester PE-TVO remove | Skyla Hi POC Clinical Chemistry Analyzer remove | Hawksley 1400 Haematocrit Centrifuge remove | Eppendorf Minispin Centrifuge remove | Eppendorf Pipette Tip 20ul Per Pack remove | Zenithlab (IB-9025A) Laboratory Incubator remove | ||||||||||
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||||||
SKU | SF1033560106 | SF1033560060-2 | SF1033560084-118 | SF1033560084-116 | SF1033560084-136 | SF1033560084-109 | ||||||||||
Rating | ||||||||||||||||
Price |
|
| $690.00 |
|
| $350.00 | ||||||||||
Stock | ||||||||||||||||
Availability | ||||||||||||||||
Add to cart | ||||||||||||||||
Description | Shipped From Abroad
Purpose:
The tester PE-TVO is intended for usage as laboratory equipment to perform open cup flash point determination of oil products according to method A ASTM D92 and GOST 4333-87.
Delivery & Availability:
Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from Abroad The skyla Hi POC Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results.The use of skyla Hi in the management of diabetes enables better access to testing and rapid clinical decision making, discussion,and implementation of optimized treatment. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
| In stock
| In stock
| In stock
| ||||||||||
Content | Purpose: The tester PE-TVO is intended for usage as laboratory equipment to perform open cup flash point determination of oil products according to method A ASTM D92 and GOST 4333-87. Technical specifications: - Maximum heating temperature, °C - up to 370 - Power supply voltage from AC mains with frequency of 50Hz, V - 220±22 - Power consumption, no higher than, W - 1000 - Instrument weight, kg – 5 - Service life, years at least – 5 Operation conditions: - Air temperature, °C - 15?35 - Relative humidity, % - 30?90 - Overall dimensions (body), mm: - Length, mm - 330 - Width, mm - 250 - Height, mm - 165 - Range of flash point determination, °C - 25-370 - Ignition device, type - gas - Control of electric heating power – electronic - Automatic passage of burner above surface of sample at set speed - Availability of gas network or cylinder (methane, propane/butane) is required Scope of delivery: 1. The open cup flash point tester PE-TVO complete with cup - 1 pc. 2. Thermometer TH-2 according to GOST 400 – 1 pc. 3. Template for flame adjustment – 1 pc. 4. Operation manual- 1 pc. 5. Packaging crate – 1 pc. | skyla Hi Analyzer enables better access to testing and rapid clinical decision making, discussion, and implementation of optimized treatment. To get the result, only prepare <1 μl fingertips blood or venous blood (depends on test item) without pretreatment with easy steps and then read the result after 6 mins. The device allows two specimens be tested in one run and provides fully automatic procedures from checking the validity of cartridge to printing the results.
Reagent Kit
Main SpecificationPrinciple
Turbidimetric Method / Biochemistry
Device
Testing Time
5~20 minutes (depends on test items)
Display and Interface
5″ TFT color touch screen LCD
Memory Capacity
50,000 test results
Dimension of Analyzer
270 x 188 x 148 mm
Weight of Analyzer
1.7 kg
Dimension of Printer Module
134 x 100 x 82.7 mm
Weight of Printer Module
0.37 kg
Power Supply
100~240 volts AC, 50-60Hz
Data Transmission
USB 2.0*4 / USB 3.0*1 / RS232*1 / RJ45*1 / Wi-Fi (optional)
Reagent and SamplesSamples
Fingertips blood or venous blood
Samples Volume
0.8 ~ 30 μL (depends on test item)
Storage Temperature (Reagent)
2 ~ 8˚C
HumidityRelative humidity < 95% (Non-condensing)
| The Hawksley Haematospin 1400 Centrifuges are built in the UK and are made from durable and high-quality components. These centrifuges are ideal for veterinary laboratories and practices specifically designed to produce reliable and accurate results on blood and urine. One of the main features of this centrifuge is that it takes both 2ml microtubes and 75mm microhaematocrits. The classic design of these centrifuges is used worldwide with guaranteed support for all servicing and parts.
Technical specifications:
Click Here To Download Catalogue | Powerful and user-friendly MiniSpin Centrifuge are small enough so that each workstation can be equipped with a “personal” centrifuge. The rotor, inner centrifuge lid, and lid latch are made of metal for maximum operation safety.
Features:
Click Here To Download Catalogue |
| Features:
| ||||||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||
Additional information |
Reviews
There are no reviews yet.