Description | Shipped From Abroad
This CO2 incubator has been specifically designed to provide performance reliability, ease of operation and value for a range of incubation needs, from basic research to demanding cutting-edge applications.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| In stock
- Made of high quality PP material with good transparency.
- Applied for Gilson/Finland/Eppendorf Pipettors.
- Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
- Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
- Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
- Total Volume: 60mL.
- Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
- Made of premium PP material, it is durable for usage.
- Some measurements can be used to not only use urine samples, it can also be used for other liquids.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped From Abroad
Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
This Automatic Pipette will help you get your lab up and running in no time—at a great price!
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR).
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. |
Content | CO2 Incubator Features:
For advanced uniformity and recovery, our airflow patterns are specifcally designed for outstanding distribution of critical environmental conditions (temperature, gas exchange and humidity). Forced-air fan gently and evenly distributes clean, humidifed air throughout the chamber ensuring all cells experience the same conditions without the threat of desiccation. Temperature and gas sensors are placed in the chamber to ensure the detected temperature and gas are in the same conditions.
Designed for sensitive cells and It is designed to protect valuable samples while optimizing cell growth.
1. 180°C Dry heat sterilization
2. Optional tri-gas
3. Top IR sensor
4. LCD touch screen
Applications of CO2 Incubator:
- Cell culture and cell growth
- Tissue engineering and regenerative medicine research
- Cellular virology and bacteriology experiments
- Drug screening and pharmacological research
- Medical clinical diagnostics and biomedical research
Product Data
- Temperature Range(℃) : RT+3~55
- CO2 Range : 0~20%
- Sterilization : 180°C dry heat
- Humidity Method : Integrated pan
- External Size (W×D×H)(mm) : 670×825×920
CO2 Incubator Specifications:
Model |
ICB-170 |
Temperature |
Type |
Direct Heat & Air Jacketed |
Range |
RT+3°C to 55°C |
Uniformity |
≤±0.3°C |
Accuracy |
<±0.1°C |
Recovery |
≤10 mins |
Ambient |
18-34°C |
CO2 |
Controller |
PID microcomputer |
Range |
0~20% |
Accuracy |
±0.1% |
Sensor |
IR |
Recovery |
≤5 mins |
Sterilization |
180°C dry heat |
Humidity |
Mode |
Integrated pan |
rH% |
91% @ low rH mode, 94% @ High rH mode |
Recovery |
15 mins |
O2 (Optional Tri-gas Type) |
Controller |
PID microcomputer |
Range |
1~20.7% |
Accuracy |
±1% |
Sensor |
Zirconia |
Accuracy |
O2% @ 1.0%: 24mins; O2% @ 5.0%: 10mins |
Alarm and Reminder |
Alarms |
Ambient temp., rH%, CO2%, Water level, O2% (optional) |
Reminder |
HEPA filter expiration, shortage of gas |
Cleanliness |
Sterilization |
180°C dryheat |
0.2um filter |
HEPA filter |
Specifications |
Capacity |
170L |
Internal Construction |
Polished stainless steel |
Shelf Qty (Standard) |
3 |
Max Shelf Qty |
Up to 7 optional |
Shelf Size (WxD mm) |
450x485(Big); 450x440(small) |
Max Loading of Each Shelf |
12kg |
Power Supply |
AC220V, 50/60Hz |
Max. Power |
1000W |
Stable Power |
42W |
Internal Size (WxDxH)(mm) |
490×560×621 |
External Size (W×D×H)(mm) |
670×825×920 |
Shipping Size (W×D×H)(mm) |
1135×730×965 |
N.W./G.W. (kg) |
94/105 |
|
- Made of high quality PP material with good transparency.
- Applied for Gilson/Finland/Eppendorf Pipettors.
- Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
- Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
- Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
Classification: PIPETTE
Brand Name: Vchanslab,Yingmed,OEM
Model Number: YM-K7028
Place of Origin: China
Product name: Pipette Tips
Material: Polypropylene
Certificate: CE/ISO13485/FDA
Color: Natural, Blue, Yellow
Application: Laboratory, Teaching, Hospital |
- Total Volume: 60mL.
- Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
- Made of premium PP material, it is durable for usage.
- Some measurements can be used to not only use urine samples, it can also be used for other liquids.
| Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface.
Features:
- Parameters: Na+,K+,Cl-, iCa++ / Li
- It works on ISE principle
- Sample Type: Whole blood, Serum, Plasma, Urine
- Low reagent consumption
- Sample requirement is only 90ul
- 60 samples per hour
- Automatic two point calibration after 4hrs and one point calibration with each sample analysis
- Air bubble detection
- Track reagents consumption and provides alerts
- For low reagent volume
- Precision testing facility to get CV and SD
- Trilevel Quality Control with LJ plots of last 30days
- Low aspiration volume
- Fast sample processing
- Accurate and Precise results
Technical Specifications:
Parameters |
Na+, K+, Cl– /Ca++ |
Principle |
Ion Selective Electrode (ISE) |
Sample Type |
Analyses whole blood, serum, plasma and urine |
Sample Volume |
≤100 µL |
Analysis Time |
≤60 seconds |
Throughout |
≤60 samples per hour |
Data Link |
Serial (RS232) |
External Interface |
USB (Keyboard, Mouse) |
Operating Condition |
10° C to 35° C, Relative Humidity up to 85% |
Storage Condition |
Temp: 10° C to 40° C |
Relative Humidity |
up to 85% non- condensing |
Power Supply |
100 to 240 VAC ±10%, 50Hz |
Dimensions |
395 x 260 x 375 mm |
Weight |
7.5 kg |
| This Automatic Pipette will help you get your lab up and running in no time—at a great price!
Features:
- Lowest operation and tip ejection forces
- Fully autoclavable
- Ultra light weight with space-age materials
- Secondary adjustment option for various liquid classes
- Spring loaded tip con
- For transferring molecular samples and PCR mix solutions.
- One set is for DNA work and the other for RNA work. Each with the following specs
- Light weight, traditional tip shaft, and will fit all generic brands of tips
- Equal to or better than accuracy and precision compared to ISO 8655, so results can be trusted.
- Easy and quick volume adjustment with or without gloves. Foolproof volume lock prevents accidental volume changes.
- Low maintenance and autoclavable 121° for at least 20 minutes
- Quick release
| The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Unlike traditional ESR methodologies that measure the aggregation of the red blood cells indirectly, the iSED measures it directly and expresses the values in mm/hr.
Features:
-
-
100µL sample drawn directly from primary EDTA tube
-
Fully automated, walk-away operation
-
-
Positive patient identification via internal barcode reader
-
Compatible with pediatric tube
Technical Specifications:
Principle of Measure: |
Photometrical |
Results: |
“Printed mm/hr, Range from 1-130 mm/hr” |
Sample Requirements: |
500uL whole blood, collected in EDTA anti-coagulant tested 24 hours from venipuncture at room temperature or refrigerated. |
Tube Requirements: |
13 x 75 mm, pierceable capped tube |
Quality Control: |
Barcoded Seditrol® QC |
Barcode Reader: |
Internal |
Printer: |
Internal |
Interface Specifications: |
serial RS232 port for LIS connection |
Weight: |
14 kg |
Dimensions (H x W x D): |
36 x 27 x 34 (cm) /14.3 x 10.5 x13.4 (in) |
Voltage: |
100-240VAC |
Frequency Range: |
50-60 Hz |
Power: |
160W |
Click Here To Download Catalogue |
Reviews