CO2 Mainstream Module Capno-M

$248.00

Shipped From Abroad

A mainstream end-tidal carbon dioxide monitoring sensor, it has a unique sample cell that protects internal NDIR components from pollution. Compatible with multiple protocols (Respironics, Phasein, CPT, KM, etc.)

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Brands:: Kingst

Description

Features of CO2 Mainstream Module Capno-M
  • Plug and play

There is no circuit inside the host, just a serial port.

  • High Precision

Carefully selected multi-channel narrowband filters and infrared light sources, hardware design, and software algorithm, to achieve a high signal-to-noise ratio, to ensure measurement accuracy in the temperature range of 5-50°C and the concentration range of 0-20%.

  • Low Power Consumption

Suitable for battery-powered use, instant start, and accurate data can be obtained within 10 seconds of power-on.

  • Atmospheric pressure and Interference gas compensation

By receiving the pressure and interfering gas parameters input by the host, the compensation calculation can be automatically performed to ensure measurement accuracy on a variety of occasions.

  • OEM Solution

Reliable EtCO2 OEM solutions, multiple communication protocols to make your products quickly upgrade assembly.

 

Specifications of CO2 Mainstream Module Capno-M
Technique Non-dispersive infrared gas analysis, multi-channel infrared detector, no moving parts
Storage condition -40°C to 70°C,<93% RH, non-condensing
Working condition 5 to 50°℃,10 to 90% RH, non-condensing
Circumstance pressure 55-115kP
Power demand 5V ± 5% (max ripple 200 mVp-p)
Power consumption <150mA
interface RS-232/Standard E-8-1, 38.4 kBaud,10 ms data interval (KM) or customized communication protocol.
CO2 measurement range 0-150 mmHg, 0-20 kPa, 0-19.7%
CO2 resolution 0.1mmHg
co2 measurement accuracy 0 – 40 mmHg ± 2 mmHg 41 – 70 mmHg ± 5% of reading 71 – 100 mmHg ± 8% of reading 101 – 150 mmHg ± 10% of reading
Respiration rate 3-150 bpm
Respiration rate accuracy ±1% of reading or ±1 rpm whichever is greater
Anesthetic gas compensation N2O, O2, Agent (HOST supplied)
Barometric Pressure Barometric Pressure 400 to 860 mm Hg automatic
Warm-up time To reach designed deviation 97% within 8s, to reach designed deviation within 20s.
Rise time About 70ms
CO2 Stability Shortly drifting: drifting less than 1 mmHg, after 4 hours’ power on. Long drifting: drifting does not influence nominal accuracy after continuous 140 hours of power on.
Calibration No routine user calibration required
Zero proceeding when replacing the adaptor
EtCO2 calculation every breath, or 10 or 20 seconds averagely

 

Application Scenarios of CO2 Mainstream Module Capno-M
  • High signal-to-noise ratio

Capno-M is a mainstream CO2 module.

It is equipped with high-quality Multi-Channel Narrowband Filters, IR Light Source, Well-designed Hardware Circuit, and Software Algorithms to achieve gas concentration measurement with a high signal-to-noise ratio;

  • Long continuous working time

With the self-developed adapters, they can continuously work for a long time in high-temperature environment.

  • Plug-and-play

It can be used in conjunction with a multi-parameter monitor. The monitor only needs one interface, which can be connected to the module for use.

  • Atmospheric pressure compensation

There is an internal atmospheric pressure sensor, which can automatically adjust the atmospheric pressure and suitable for various altitude ranges and harsh environments;

  • OEM solutions

We provide the reliable carbon dioxide OEM solutions, with multiple protocols, so that products can be quickly upgraded and assembled.

 

Reviews

There are no reviews yet.

Be the first to review “CO2 Mainstream Module Capno-M”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsCO2 Mainstream Module Capno-M removeEndobronchial Blocker Tube removeDisposable Reinforced Silicone Laryngeal Mask removeParker Flex-tip Endotracheal Tube removeNasal Tracheal Tube, Uncuffed removeTracheobronchial Tube remove
NameCO2 Mainstream Module Capno-M removeEndobronchial Blocker Tube removeDisposable Reinforced Silicone Laryngeal Mask removeParker Flex-tip Endotracheal Tube removeNasal Tracheal Tube, Uncuffed removeTracheobronchial Tube remove
Image
SKUSF1033560130102-15SF1033560130102-19SF1033560130102-11SF1033560130102-4SF1033560130102-14
Rating
Price

$248.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad A mainstream end-tidal carbon dioxide monitoring sensor, it has a unique sample cell that protects internal NDIR components from pollution. Compatible with multiple protocols (Respironics, Phasein, CPT, KM, etc.)
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Features of CO2 Mainstream Module Capno-M
  • Plug and play
There is no circuit inside the host, just a serial port.
  • High Precision
Carefully selected multi-channel narrowband filters and infrared light sources, hardware design, and software algorithm, to achieve a high signal-to-noise ratio, to ensure measurement accuracy in the temperature range of 5-50°C and the concentration range of 0-20%.
  • Low Power Consumption
Suitable for battery-powered use, instant start, and accurate data can be obtained within 10 seconds of power-on.
  • Atmospheric pressure and Interference gas compensation
By receiving the pressure and interfering gas parameters input by the host, the compensation calculation can be automatically performed to ensure measurement accuracy on a variety of occasions.
  • OEM Solution
Reliable EtCO2 OEM solutions, multiple communication protocols to make your products quickly upgrade assembly.  
Specifications of CO2 Mainstream Module Capno-M
Technique Non-dispersive infrared gas analysis, multi-channel infrared detector, no moving parts
Storage condition -40°C to 70°C,<93% RH, non-condensing
Working condition 5 to 50°℃,10 to 90% RH, non-condensing
Circumstance pressure 55-115kP
Power demand 5V ± 5% (max ripple 200 mVp-p)
Power consumption <150mA
interface RS-232/Standard E-8-1, 38.4 kBaud,10 ms data interval (KM) or customized communication protocol.
CO2 measurement range 0-150 mmHg, 0-20 kPa, 0-19.7%
CO2 resolution 0.1mmHg
co2 measurement accuracy 0 - 40 mmHg ± 2 mmHg 41 - 70 mmHg ± 5% of reading 71 - 100 mmHg ± 8% of reading 101 - 150 mmHg ± 10% of reading
Respiration rate 3-150 bpm
Respiration rate accuracy ±1% of reading or ±1 rpm whichever is greater
Anesthetic gas compensation N2O, O2, Agent (HOST supplied)
Barometric Pressure Barometric Pressure 400 to 860 mm Hg automatic
Warm-up time To reach designed deviation 97% within 8s, to reach designed deviation within 20s.
Rise time About 70ms
CO2 Stability Shortly drifting: drifting less than 1 mmHg, after 4 hours’ power on. Long drifting: drifting does not influence nominal accuracy after continuous 140 hours of power on.
Calibration No routine user calibration required
Zero proceeding when replacing the adaptor
EtCO2 calculation every breath, or 10 or 20 seconds averagely
 
Application Scenarios of CO2 Mainstream Module Capno-M
  • High signal-to-noise ratio
Capno-M is a mainstream CO2 module. It is equipped with high-quality Multi-Channel Narrowband Filters, IR Light Source, Well-designed Hardware Circuit, and Software Algorithms to achieve gas concentration measurement with a high signal-to-noise ratio;
  • Long continuous working time
With the self-developed adapters, they can continuously work for a long time in high-temperature environment.
  • Plug-and-play
It can be used in conjunction with a multi-parameter monitor. The monitor only needs one interface, which can be connected to the module for use.
  • Atmospheric pressure compensation
There is an internal atmospheric pressure sensor, which can automatically adjust the atmospheric pressure and suitable for various altitude ranges and harsh environments;
  • OEM solutions
We provide the reliable carbon dioxide OEM solutions, with multiple protocols, so that products can be quickly upgraded and assembled.
 
Endobronchial Blocker Tube is designed to differentially intubate a patient’s bronchus inorder to Isolate the left or right lung for procedures that require one-lung ventilation. • Size 5fr, 7fr. 9fr meeting clinical needs, for all patients from pediatric to adult. • Ultra-thin cuff made of medical grade PU, 0.028 mm thickness, comfortable and soft. It creates a superior seal and reduces microaspiration, when deflated it is very close to blocker's tube thickness, so it can pass ETT easily. • Twist lock design, easy operation, secure locking.
REF Size Tube length Cuff length Resting Cuff
GCR105009 9Fr 695 18 15
GCR105007 7Fr 695 16 12
GCR105005 5Fr 640 10 8
Features
REF Size Applicable People Color Code Qty.Cs
GCR104229 1.0 <5kg Purple 10
GCR104230 1.5 5-10kg Orange 10
GCR104231 2.0 10-20kg Blue 10
GCR104232 2.5 20-30kg White 10
GCR104233 3.0 30-50kg Green 10
GCR104234 4.0 50-70kg Yellow 10
GCR104235 5.0 70-100kg Red 10
Features • It  has a flexible, curved, tapered geometrical distal tip designed to facilitate quick, easy, non-traumatic intubation. • A soft flex-tip at the end of the tube, in order to insert easily.Features • For nasal intubation use. • Responsive pilot balloon. • Bull-nose tip. • Split-resistant radiopaque line. • Smooth Murphy eye. • Kink-resistant thermosensitive tube. Size Available: 3.0, 3.5, 4.0, 4.5, 5.0, 5.5, 6.0, 6.5, 7.0, 7.5, 8.0, 8.5, 9.0, 9.5, 10.0 Quantity per Case: 100Features • Use for one-lung ventilation, in the OPS of bronchus, thoracic surgery and so on. • Made of medical grade PVC, transparent, soft and smooth. • Left-sided or right-sided available. • Different side of tubes distinguishable by two different cuffs. • Equipped with two suction catheters, one stylet and one switch connector. • Easily operate one-lung ventilation by switch connector
REF Type Color Code Qty.Cs
GCR105028 28Fr / 100
GCR105032 32Fr / 100
GCR105035 35Fr / 100
GCR105037 37Fr / 100
GCR105039 39Fr / 100
GCR105041 41Fr / 100
GCR105029 / 28Fr 100
GCR105033 / 32Fr 100
GCR105036 / 35Fr 100
GCR105038 / 37Fr 100
GCR105040 / 39Fr 100
GCR105042 / 41Fr 100
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare