The CP-60 Chart Projector delivers clear, bright, and precise visual acuity testing. With multiple optotype charts, quick rotation, and adjustable projection distance, it ensures efficient eye examinations for patients of all ages. Compact, durable, and user-friendly, it is ideal for hospitals, clinics, and optical centers.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Brands:: zbxyoptics

Description

The CP-60 Chart Projector is a reliable and versatile vision testing instrument designed for precise and efficient eye examinations. Compact and durable, it projects a wide selection of optotypes, including letters, numbers, Landolt rings, and children’s charts, making it suitable for patients of all ages. With high-brightness projection and sharp image clarity, the CP-60 ensures accurate visual acuity assessment under consistent testing conditions. The projector offers multiple chart options, adjustable projection distances, and quick chart rotation, enhancing efficiency for optometrists and ophthalmologists. Designed for clinical accuracy, the CP-60 is ideal for use in hospitals, optical centers, and private practices. Its ergonomic design, user-friendly controls, and long-lasting light source provide reliable daily operation. Whether used for standard vision screening or comprehensive eye exams, the CP-60 Chart Projector delivers dependable performance and supports accurate diagnosis, making it an essential tool in professional vision care.

Key Features
  • Bright, sharp projection for accurate vision testing

  • Wide selection of optotype charts (letters, numbers, Landolt rings, pediatric charts)

  • Adjustable projection distance (typically 2.5–6 m)

  • Quick and smooth chart rotation

  • Consistent brightness for reliable results

  • Compact and durable design for clinical use

  • Long-lasting illumination source

  • Suitable for patients of all ages

Specifications

Projection distance

3m to 6m
Charts 39 kinds
Masking function No mask, Horizontal line mask, Vertical line mask, Single letter mask
Filtering function Red/Green filter
Chart changeover speed Average of 0.2 seconds or less
Chart size 336(W)mm×225(H)mm (at the distance of 5m)
Lamp LED
Weight ~5kg
Dimensions 208mm×346mm×287mm
Power source AC 100V- 240V 36W

Reviews

There are no reviews yet.

Be the first to review “CP-60 Chart Projector”

Your email address will not be published. Required fields are marked *

Quick Comparison

CP-60 Chart Projector removeApplanation Tonometer removeView Tester (Manual Phoropter) removeTimesco Ophthalmoscope removeOphthalmic AB Scan Machine removePantoscopic Ophthalmoscope remove
NameCP-60 Chart Projector removeApplanation Tonometer removeView Tester (Manual Phoropter) removeTimesco Ophthalmoscope removeOphthalmic AB Scan Machine removePantoscopic Ophthalmoscope remove
ImageMecan Applanation Tonometer YZ30XMecan VT-8 View Tester (Manual Phoropter)Timesco OphthalmoscopeMecan SW-2100 Ultrasound BiometryMecan MCE-800 Pantoscopic Ophthalmoscope
SKUSF1033560107-1SF1033560107-26SF1033560084-282SF1033560107-8SF1033560107-3
Rating
Price

$0.00

$0.00

$858.00

$140.00

$4,895.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad The CP-60 Chart Projector delivers clear, bright, and precise visual acuity testing. With multiple optotype charts, quick rotation, and adjustable projection distance, it ensures efficient eye examinations for patients of all ages. Compact, durable, and user-friendly, it is ideal for hospitals, clinics, and optical centers.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from abroad The product is designed on the principle basis of Goldman tonometer. It can be connected with slit lamp(Carl Zeiss type).
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Ship from abroad
  • Equipped with comprehensive measuring functions, it provides SPH, CYL, AXIS and pupil distance optometry
  • Durable and easy to operate
  • Easily and intuitively read the sphere focal scale value
  • High eco-friendly materials
  • Design fitting the face curve and no stimulation
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
In Stock
  • Durable and light weight
  • Supplied in a soft pouch
  • Long life bright white Xenon bulb
  • Macular beam dioptres lenses from 0 to +20 and 0 to -20
  • 3 year guarantee (excludes consumables)
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.    
Shipped from abroad
  • Software image workstation
  • B, B+B, B+A, A modes
  • Video review for 100 images
  • PDF report output
  • Optional 20MHz B Probe: vitreous plus function
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Shipped from abroad The brand-new Pantoscopic Ophthalmoscope is a portable digital imaging device which makes it possible to view and take pictures of the eyes.
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
ContentThe CP-60 Chart Projector is a reliable and versatile vision testing instrument designed for precise and efficient eye examinations. Compact and durable, it projects a wide selection of optotypes, including letters, numbers, Landolt rings, and children’s charts, making it suitable for patients of all ages. With high-brightness projection and sharp image clarity, the CP-60 ensures accurate visual acuity assessment under consistent testing conditions. The projector offers multiple chart options, adjustable projection distances, and quick chart rotation, enhancing efficiency for optometrists and ophthalmologists. Designed for clinical accuracy, the CP-60 is ideal for use in hospitals, optical centers, and private practices. Its ergonomic design, user-friendly controls, and long-lasting light source provide reliable daily operation. Whether used for standard vision screening or comprehensive eye exams, the CP-60 Chart Projector delivers dependable performance and supports accurate diagnosis, making it an essential tool in professional vision care.
Key Features
  • Bright, sharp projection for accurate vision testing

  • Wide selection of optotype charts (letters, numbers, Landolt rings, pediatric charts)

  • Adjustable projection distance (typically 2.5–6 m)

  • Quick and smooth chart rotation

  • Consistent brightness for reliable results

  • Compact and durable design for clinical use

  • Long-lasting illumination source

  • Suitable for patients of all ages

Specifications

Projection distance

3m to 6m
Charts 39 kinds
Masking function No mask, Horizontal line mask, Vertical line mask, Single letter mask
Filtering function Red/Green filter
Chart changeover speed Average of 0.2 seconds or less
Chart size 336(W)mm×225(H)mm (at the distance of 5m)
Lamp LED
Weight ~5kg
Dimensions 208mm×346mm×287mm
Power source AC 100V- 240V 36W
Applanation Tonometer is designed on the principle basis of Goldman tonometer. It can be connected with slit lamp(Carl Zeiss type). Features of Applanation Tonometer:
  • When used with slit lamp, it can be used to examine the eyes and measure ocular pressure.
  • Accurate measurement and total tolerance are less than 0.066KPa(0.55Hg).
  • Directly get the ocular pressure and do not need to look up the conversion table.
  • The measured ocular pressure is not affected by hardness of eye.
  • The affected?ocular volume is just 0.56 cubic millimeter.
  • Adjustable measuring pressure ensures the long-term stability and reliability.
Technical Specifications Applanation Tonometer:
  • Measuring Range: 0~1064 Kpa
  • Light Ring Displacement: 1.53×2=3.06mm
  • Diameter of Prism Head: 7mm
  • Moving Range of Prism Head: 3mm
Features:
  • Equipped with comprehensive measuring functions, it provides SPH, CYL, AXIS and pupil distance optometry
  • Durable and easy to operate
  • Easily and intuitively read the sphere focal scale value
  • High eco-friendly materials
  • Design fitting the face curve and no stimulation
  • Easy to take and clean
  • Free switch between the cross-cylindrical lens and the rotary prism
  • When the rotating risk is turning by the sphere, it can make sphere power adjust 3.00D for big scope.
  • It is designed expediently and smartly for a particular cross cylinder. Supporting supplementary lens could increase scope of measurement.
Technical Specifications:
Sphere
Range:-19.00~+16.75m-1 Step: 0.25m-1, 3.00m-1
Cylinder
Range: 0.00~-6.00m-1(Measuring Range With Accessories0.00~-8.00m-1) Step: 0.25m-1
Cylinder Axis
Range: 0~180°, Step:5°
Distance of Optical center (also known as Pupil)
Range: 50~75mmStep: 1mm
Sight Switch
Range:∞~380mm (distance of Optical center is64mm)
Front Chin Test
Range: 0~16mm
Distance (from cornea vertex to the lens surface)
16mm
Standard Accessories Lens
two pieces of Auxiliary Cylinder -2.00m-1 and -0.12m-1 respectively
Standard Accessories
one piece of M2 Hexagon wrench , one piece of a Myopia Standard Card, two piece of Myopia Standard Card , one piece of standard card holder , a dust cover
Auxiliary Lens
“O”:Open aperture “R”:Retinoscope lens “R”:Retinoscope lens “R”:Retinoscope lens *Lens of +1.50m-1 ,It is suit for the distance of 67 centimeters “P”:Polaroid * it is used for examining the dioptric balance of eyes , Implicit strabismus and stereo vision “RMV”:Red Vertical maddox *Be used to examine Implicit strabismus “RMH”:Red horizontal maddox *Be used to examine Implicit strabismus “WMV”:Plane Vertical Maddox *Be used to examine Implicit strabismus “WMH”:Plane horizontal maddox *Be used to examine Implicit strabismus “RL”:Red lens *Be used to examine eye function, Blending function and Implicit strabismus “GL”:Green lens *Be used to examine eye function, Blending function and Implicit strabismus “+”:Test mark of optical center adjustment “+.12”:Dioptric of the Spherical Lens is +0.12m-1 *Be used for the semi-adjustment of sphere lens, 0.25m-1 “PH”:1mmPinhole lens *Be used to exclude visual non-refractive errors of the tested eye “6ΔU”:6ΔBottom-up prism *Be used to examine the rotating prism with the detection of nearly horizontal squint “10ΔI”:10ΔBottom-up prism *Be used to examine the rotating prism with the detection of nearly horizontal squint “±0.50”:Cross-cylindrical lens *Be used to examine the corrected dioptric of the Presbyopia and spherical lens “OC”:Black lens
size
338(L)×99(W)×292(H)mm
NW
about 5kg
Timesco Ophthalmoscope features a head made from lightweight hermetically sealed durable plastic, precision optics and a latex free rubber eyebrow rest. A bright white light from long life standard bulbs provides crystal clear illumination in ophthalmic diagnostic procedures.
  • Durable and lightweight
  • Supplied in a soft pouch
  • Long life bright white Standard bulb
  • Macular beam dioptres lenses from 0 to +20 and 0 to -20
  • 3-year guarantee (excludes consumables)
Click Here To Download Catalogue 
Functions of Ophthalmic AB Scan Machine:
  • Software image workstation
  • B, B+B, B+A, A modes
  • Video review for 100 images
  • PDF report output
  • Optional 20MHz B Probe: vitreous plus function
Technical Specifications:
A scan 1.Probe: 10MHz frequencies, with LED 2.Depth: 40mm 3.Precision: ±0.05mm 4.Eye mode: Phakic / Aphakic / Dense / Various IOL 5.Measurement: Anterior chamber depth, lens thickness, vitreous body length, total length and average 6.IOL Formula: SRK-II, SRK-T, BINKHORST, HOLLADAY, HOFFER-Q, HAIGIS, Stat. 7.Calculation: Average and standard deviation 8.Store: 10 Scanning results for each eye
B scan 1.Probe: 10MHz/20MHz (optional), Magnetic driven, noiseless 2.Scanning Mode: Sector Scanning 3.Resolution: Lateral ≤0.3mm; Vertical≤0.2mm 4.Geometric Location Precision: Lateral≤10%; Vertical≤5% 5.Depth: 60mm 6.Enhance the part of vitreous body and retina 7.Gain of probe:30dB-105dB 8.Scanning Angle : 53° 9.Gray Scale: 256 10.False Color: Multi colors OTC 11.Measure Mode: distances, perimeter and area 12.Movies: 100 images movie review,AVI ZIP JPG format image output 13.Output: PDF format case report, connect to normal printer
Others 1.Display Mode :B, B+B, B+A, A 2.Hint: preset keyword 3.Case Search: Multi-keywords 4.Working Platform: Windows XP, VISTA, WINDOWS7 5.User-defined report template
The brand-new Pantoscopic Ophthalmoscope is a portable digital imaging device which makes it possible to view and take pictures of the eyes. The optical access of the Pantoscopic Ophthalmoscope is aligned to the visual axis of the smartphone camera by the adaptor which allows to you take pictures of the fundus and retinal nerve in high resolution. You could save pictures for each patient or email and print as needed. The Pantoscopic Ophthalmoscope provides a 5X larger view of the fundus compared with the standard ophthalmoscope. It has a wider view field of 230. Without dilating the pupil, the fundus imagines could be captured at any time and places. Features:
  • Rapid capture of fundus images on your cellphone.
  • Get eyeground documentation in an easy and low-cost way.
  • Send images to your peers across the continum of care instantly.
  • Easy carry to capture images at any clinical circumstance and work efficiently.
  • Make patient education easier.
  • 5X larger view of the fundus vs. standard ophthalmoscopes in an undilated eye.
  • Halogen lamp provides bright, white light.
  • Apertures and Filters: Looking at the pupil through an add-on corneal viewing lens, the practitioner can detect lens opacities easily.
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare