CTS-600A Automatic Target Projector

$0.00

Shipped From Abroad

The CTS-600A Automatic Target Projector delivers fast, clear, and accurate visual acuity testing. Featuring automatic chart rotation, multiple optotypes, and adjustable projection distances, it ensures efficient, reliable eye exams for patients of all ages. Compact, durable, and user-friendly, it is ideal for clinics, hospitals, and optical practices.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Brands:: zbxyoptics

Description

The CTS-600A Automatic Target Projector is a professional ophthalmic device designed for precise visual acuity testing in clinical environments. With a wide selection of optotype charts, including letters, numbers, Landolt C, and pediatric images, it provides reliable testing for patients of all ages. The CTS-600A features an automatic chart rotation system that ensures quick, quiet, and smooth transitions between targets, enhancing examination efficiency. Its high-brightness optical system delivers sharp, clear projections at adjustable distances, typically between 2.5 to 6 meters, for accurate testing under various clinical setups. Compact and durable, the CTS-600A is built with a long-lasting light source and easy-to-use controls, making it a dependable tool for optometrists and ophthalmologists. Ideal for hospitals, eye clinics, and optical centers, this projector ensures consistent, repeatable results, reducing patient fatigue while supporting accurate diagnosis and prescription. The CTS-600A combines precision, efficiency, and reliability in one advanced visual testing solution.

Key Features
  • Automatic chart rotation for quick and quiet operation

  • Bright, sharp projection for accurate vision testing

  • Wide selection of optotypes (letters, numbers, Landolt C, pediatric images)

  • Adjustable projection distance (2.5 – 6 m)

  • Consistent illumination with a long-life lamp

  • Compact, durable, and lightweight design

  • User-friendly controls for efficient operation

Reviews

There are no reviews yet.

Be the first to review “CTS-600A Automatic Target Projector”

Your email address will not be published. Required fields are marked *

Quick Comparison

CTS-600A Automatic Target Projector removePortable Fundus Camera removePortable Slit Lamp removeRetinoscope removeOphthalmic AB Scan Machine removeManual lensmeter remove
NameCTS-600A Automatic Target Projector removePortable Fundus Camera removePortable Slit Lamp removeRetinoscope removeOphthalmic AB Scan Machine removeManual lensmeter remove
ImageMecan MC-600 Portable Fundus CameraMecan S150 Portable Slit LampMecan YZ24 Streak RetinoscopeMecan SW-2100 Ultrasound BiometryMecan Manual lensmeter NJC-4
SKUSF1033560107-23SF1033560107-6SF1033560107-12SF1033560107-8SF1033560107-22
Rating
Price

$0.00

$2,310.00

$0.00

$165.00

$4,895.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad The CTS-600A Automatic Target Projector delivers fast, clear, and accurate visual acuity testing. Featuring automatic chart rotation, multiple optotypes, and adjustable projection distances, it ensures efficient, reliable eye exams for patients of all ages. Compact, durable, and user-friendly, it is ideal for clinics, hospitals, and optical practices.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
83Shipped from abroad This is a portable medical camera for fundus imaging, diagnosis, and especially for fundus disease screening. It's compact, easy to obtain high definition fundus image. It can be conveniently applied to rapid screening, out diagnosis, bedside diagnosis and remote medical treatment, etc.
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Shipped from abroad This ultra-portable is an excellent diagnostic instrument for the examination of anterior segment structures and ocular abnormalities.
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Shipped from abroad The product can quickly and precisely measure the astigmatism axis and is one of the necessary instruments in optometry inspection.
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Shipped from abroad
  • Software image workstation
  • B, B+B, B+A, A modes
  • Video review for 100 images
  • PDF report output
  • Optional 20MHz B Probe: vitreous plus function
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Shipped from abroad The NJC-4 Lensmeter is used to measure the diopters of spherical lens and cylinder lens, the axis of cylinder lens, the strength and the baseline direction of shuttle lens, it can also stamp the optical center of lens, the axis of cylinder len and the base direction of shuttle lens.
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
ContentThe CTS-600A Automatic Target Projector is a professional ophthalmic device designed for precise visual acuity testing in clinical environments. With a wide selection of optotype charts, including letters, numbers, Landolt C, and pediatric images, it provides reliable testing for patients of all ages. The CTS-600A features an automatic chart rotation system that ensures quick, quiet, and smooth transitions between targets, enhancing examination efficiency. Its high-brightness optical system delivers sharp, clear projections at adjustable distances, typically between 2.5 to 6 meters, for accurate testing under various clinical setups. Compact and durable, the CTS-600A is built with a long-lasting light source and easy-to-use controls, making it a dependable tool for optometrists and ophthalmologists. Ideal for hospitals, eye clinics, and optical centers, this projector ensures consistent, repeatable results, reducing patient fatigue while supporting accurate diagnosis and prescription. The CTS-600A combines precision, efficiency, and reliability in one advanced visual testing solution.
Key Features
  • Automatic chart rotation for quick and quiet operation

  • Bright, sharp projection for accurate vision testing

  • Wide selection of optotypes (letters, numbers, Landolt C, pediatric images)

  • Adjustable projection distance (2.5 – 6 m)

  • Consistent illumination with a long-life lamp

  • Compact, durable, and lightweight design

  • User-friendly controls for efficient operation

Portable Fundus Camera is a portable medical camera for fundus imaging, diagnosis, and especially for fundus disease screening. It's compact, easy to obtain high definition fundus image. It can be conveniently applied to rapid screening, out diagnosis, bedside diagnosis and remote medical treatment, etc. Features of Portable Fundus Camera:
  • Images real-time display, one-button magnifying
  • Non-mydriatic and high definition imaging.
  • Micro SD memory card up to 32GB for 80,000 images
  • USB and WiFi connection
  • Low weight 450g, movable and portable
  • A rechargeable battery provides up to more than 4 hours of continuous operation.
  • Optional imaging modules for examination: posterior ophthalmoscope, anterior segment ophthalmoscope, otoscope, rhinoscope, laryngoscope and dermatoscope
  • High definition and stable image
  • Easy one-handed operation and excellent portability
  • Large data service and a variety of image acquisition mode
Technical Specifications of Portable Fundus Camera:
Model MC-600
FOV 45°
Minimum pupil 2.5mm
Refractive compensation -20D~+20D
Light source White LED/IR
Image resolution 1920×1080
Focus Mode Manual
Screen 3.5" color
Power ≤6VA
Storage 8GB Micro SD card
Power supply 3.7VLithium Battery
Interface Mini USB/Wifi
N. Weight 450g(Typical)
G. Weight 2.5kg
Size 160mm*90mm*190mm
Packing size 360mm*310mm*160mm
Features:
  • Ultra-portable: This ultra-portable is an excellent diagnostic instrument for the examination of anterior segment structures and ocular abnormalities. Its easy-to-operate optical system produces a high-brightness, continuously adjustable slit image ideal for pediatric and geriatric setting, emergency department screenings, ward rounds, beside examination, post-op evaluations, and mission work;
  • LED illumination: the first and the only portable slit lamp in the world applying LED illumination system. The most prominent advantage of our LED illumination system gives the examiner the clearest image without glare;
  • Comfortable using experience: The low heat radiation from our LED lamp makes the most comfortable examine experience for the patient;
  • Sharpest Slit: With the blade imaging system S150 gives equally sharpest slit as the best classic slit lamp in the world;
  • No need to replace illumination lamp: The LED lamp used in S150 portable slit lamp is rated 20,000 hours at full power. Its lifetime is almost 10 times longer than a normal halogen lamp;
  • Power-saving: S150 can work for long hours without changing batteries.
Technical Specifications:
  • Magnification: 5x
  • Range of slit length: 5mm~11mm
  • Minimum slit width: 0.2mm
  • Working distance: 12~32mm
  • Power supply: AA batteries x 2
  • Illumination: LED blub(3.3V/1W)
  • Battery life: More than 3h(AA alkaline batteries x 2)
  • Net weight: 150g(without batteries)
How to Operate:
  • Press the Power Switch to turn the slit lamp on/off
  • Loosen the Locking Screw
  • Twist the Lamp Body while holding the Magnifier Bracket still till the slit is in the required angle
  • Push or pull the Lamp Body while holding the Magnifier Bracket still to set the Magnifier into a position comfortable for observation
  • Fasten the Locking Screw
  • Pull the Lamp Head back and forth for adjusting the width and the length of the slit, as well as the intensity of the light
The product can quickly and precisely measure the astigmatism axis and is one of the necessary instruments in optometry inspection. Features:
  • The filament can be rotated for 360° and move upward and downward. The brightness of the streak can be adjusted.
  • Quickly and precisely measure the astigmatism axis.
  • The light can be converged, radiated, and paralleled.
  • Automatic Power Off function effectively protects the bulb.
  • Two-steps adjustable brightness for bulb: S(Bright) and W(Dark).
Technical Specifications:
Working Distance 1 m
Streak 3 mm-20 mm
Streak Rotation 360°
Illumination Source 3V/2W, halogen bulb
Input Voltage AC 220V±10%, 50Hz±1Hz
Power Consumption 4.5 VA
Functions of Ophthalmic AB Scan Machine:
  • Software image workstation
  • B, B+B, B+A, A modes
  • Video review for 100 images
  • PDF report output
  • Optional 20MHz B Probe: vitreous plus function
Technical Specifications:
A scan 1.Probe: 10MHz frequencies, with LED 2.Depth: 40mm 3.Precision: ±0.05mm 4.Eye mode: Phakic / Aphakic / Dense / Various IOL 5.Measurement: Anterior chamber depth, lens thickness, vitreous body length, total length and average 6.IOL Formula: SRK-II, SRK-T, BINKHORST, HOLLADAY, HOFFER-Q, HAIGIS, Stat. 7.Calculation: Average and standard deviation 8.Store: 10 Scanning results for each eye
B scan 1.Probe: 10MHz/20MHz (optional), Magnetic driven, noiseless 2.Scanning Mode: Sector Scanning 3.Resolution: Lateral ≤0.3mm; Vertical≤0.2mm 4.Geometric Location Precision: Lateral≤10%; Vertical≤5% 5.Depth: 60mm 6.Enhance the part of vitreous body and retina 7.Gain of probe:30dB-105dB 8.Scanning Angle : 53° 9.Gray Scale: 256 10.False Color: Multi colors OTC 11.Measure Mode: distances, perimeter and area 12.Movies: 100 images movie review,AVI ZIP JPG format image output 13.Output: PDF format case report, connect to normal printer
Others 1.Display Mode :B, B+B, B+A, A 2.Hint: preset keyword 3.Case Search: Multi-keywords 4.Working Platform: Windows XP, VISTA, WINDOWS7 5.User-defined report template
The NJC-4 Lensmeter is used to measure the diopters of the spherical lens and cylinder lens, the axis of cylinder lens, the strength and the baseline direction of shuttle lens, it can also stamp the optical center of the lens, the axis of cylinder lens, and the base direction of shuttle lens. This instrument (Both Ac and Dc are permitted Two cells When Dc) has clear readings and graduations as well as high objective precision and reliabilities except that it can be operated easily and conveniently, AU the lenses and the made glasses can be measured by it, therefore, it is a required and ideal measuring instrument for glasses manufactures, glasses stores and ophthalmological hospitals. Technical Specifications:
  • Eyepiece focusing range: ±5D
  • The top point diopter measuring range: 0—±20D
  • The minimum measuring square value: 0.125D
  • The shuttle lens measuring range: 5A
  • The shuttle lens square value: 1A
  • The cylinder lens axial range: 0—180°
  • The cylinder lens axial square value: 5°
  • The maximum diameter of the measured lenses l00m/m
  • Power supply: AC 110V-6V DC 3V
  • Note: This item is AC 110V; The battery is not included!
 
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare