Disposable LOOP Tungsten Electrode

$0.00

Shipped From Abroad

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Brands:: OBS

Description

 

Features

1. Stainless steel & non-stick finish

2. The hexagonal connection ring fits the pencil locking design.

3. Different shapes fitting for different surgeries

Reviews

There are no reviews yet.

Be the first to review “Disposable LOOP Tungsten Electrode”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsDisposable LOOP Tungsten Electrode removeOBS-100A Monopolar Electrosurgical Unit removeOBS-100C LCD Version Dual cold RF Electrosurgical Unit removeArthroscopic Ablator removeDisposable Skin Stapler removeElectrosurgical Forceps remove
NameDisposable LOOP Tungsten Electrode removeOBS-100A Monopolar Electrosurgical Unit removeOBS-100C LCD Version Dual cold RF Electrosurgical Unit removeArthroscopic Ablator removeDisposable Skin Stapler removeElectrosurgical Forceps remove
Image
SKU
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad Unique dual radio frequency design. Combines 4Mhz and 1.7Mhz into one generator. Realizes the best operation result effectively. Suitable for  Plastic, Dermatology, ENT, Ophthalmology, Dentistry, Podiatry and Spinal surgery
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Sterile Disposable Skin Stapler is a disposable equipment that applies to skin sutures during general surgical operation, Cardiothoracic Surgery, plastic surgery, neurosurgery operation, gynecologic surgery, burn surgery, emergency operation, and field rescue. It can be used in operating room, delivery room, emergency department, outpatient surgery, and clinics.Shipped From Abroad Mainly used for bipolar subtle coagulation in microsurgery, neurosurgery, spine surgery, and medical cosmetology
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content  
Features
1. Stainless steel & non-stick finish 2. The hexagonal connection ring fits the pencil locking design. 3. Different shapes fitting for different surgeries
 
Features

1. Portable and  affordable

2. Suitable for general surgery and veterinary
Technical Details
Environmental temperature range: 5°C~ 40°C
Relative moisture range: ≤80%
Atmosphere pressure range: 86.0 Kpa ~ 106.0 Kpa
Working modes:
Pure cut: 5w ~ 100w (Load:300Ω)
Blend cut: 5w ~ 50w (Load:300Ω)
Forced coagulation: 5w ~ 80w (Load:500Ω)
Soft coagulation: 5w ~ 50w (Load:500Ω)
Technology data:
Voltage: 230V±10V, 50Hz
Working frequency: 330KHz ~ 460KHz
Leakage currents to ground: Less than 0.5mA
Leakage currents to patient: Less than 0.01mA
Features
  • Clinic result proves that higher frequency can get less tissue resists nee. 4Mhz frequency can reduces heat injury a ind carbonizing to tissue at maximum. It realizes low temperature cutting.
  • The antenna pad is unnecessary for skin touch, no current goes through the body, and no possibility of burning
  • No pressure cutting and the pencil is operated easily and it's full of flexibility.
  • No carbonation, less bleeding, and no adhesions.
  • Less pain, scarring, and fast healing after operation.
Technical Parameters
Image
Product Details
OUTPUT MODE 
  • CUT - For micro-smooth cutting
  • BLEND - For cutting with coagulation
  • HEMO - For pure Hemostasis-Coagulation to control most forms of bleeding
  • FULGURATION - For desiccation or fulgurate spark-gap
  • BIPOLAR - For precise coagulation utilizing bipolar energy
INTENDED USE
  • Cutting: snoring, submucosal palatal shrinkage, traditional uvulopalatoplasty (RAUP), myringotomy with effective hemorrhage control, epistaxis treatment, turbinate shrinkage, skin incisions, biopsy, cysts, abscesses, tumors, cosmetic repairs, development of skin flaps, skin tags and blepharoplasty.
  • Blended (cutting and coagulation): snoring, submucosal palatal shrinkage, traditional uvulopalatoplasty (RAUP), myringotomy with effective hemorrhage control, epistaxis treatment, turbinate shrinkage, skin tags, papilloma keloids, keratosis, verrucae. basal cell carcinoma, nevi, fistulas, epithelioma, cosmetic repairs, cysts, abscesses, and development of skin flaps.
  • Hemostasis: control of bleeding, epilation, telangiectasia.
  • Fulguration: basal cell carcinoma, papilloma, cyst destruction, tumors, verrucae, hemostasis.
  • Bipolar: pinpoint precise coagulation, pinpoint hemostasis in any field (wet or dry), snoring, submucosal palatal shrinkage, traditional uvulopalatoplasty (RAUP), myringotomy with effective hemorrhage control, epistaxis treatment and turbinate shrinkage.
Transportation Data :
  • WxHxD:34(L)'23.5(W)*10.6(H) 49(L)*35.5(W)'31(H)cn Weight:8.2kg(NetWeight);12. cm(Generator) i(outer carton) 1kg(Gross Weight)
  • Standard Matching Accessories
  • Instruction for Use: 1pc
  • Power Cord: 1pc
  • Dual Pedal Switch: 1pc
  • Disposable ESU Pencil: 2 pes
  • Reusable Antenna Pad with cable: 1 set
  • Reusable Bipolar Forceps with Cable: 1 set
  • Reusable ESU pencil: 1 pc
  • Reusable Fine Electrode tips (Needle, curved, Needle .Ball): 7pcs
  • Disposable leep Electrode tips: 5pcs
Features

1. Intended for ablation,tissue modification, and coagulation of soft tissue in arthroscopic procedures such as hip,  shoulder, ankle, wrist, elbow, and knee. 2. The Extending shaft enables good visualization and easy insertion through subcutaneous tissue,and  well insulated coating guarantee its safety and reliability. 3.Irrigation/suction solution is available with a cannula and an adjustable flow control valve. 4. Tips in different shapes and angles fit in particular arthroscopic procedures. 5. Compatible with most electrosurgical generators.

Use Indication

This device should never be used when:

  • There is visible evidence of damage to the exterior of the device such as cracked or damaged plastic or connector damage.
  • These devices fail the inspection described herein.
  • In the presence of flammable gases, flammable prep solutions or drapes. Oxidizing. Gases such as Nitrous Oxide (N2O), or in oxygen-riched environments.
  • Do not use monopolar electrosurgery on small appendages, as in circumcision or finger surgery.
Features
  • Concise and reasonable design, which is easy and convenient to operate.
  • Safe and efficient for surgery, and the needle could be withdrawn fluently and accurately.
  • Smooth and beautiful suture, small and micro healing scar.
  • There's good compatibility with tissues and less inflammatory response.
  • It's easy and convenient to take out the stitches, which will promote wound healing.
  • Sterile Disposable Skin Stapler reduces the patient's pain and improves operation efficiency.
Features
  • Biocompatible Material, latex-free in construction
  • Ratchet handles are designed ergonomically which comfortably fit into the surgeon´s hand
  • Nylon coating resists abrasion and provides superb insulation.
  • Well-balanced and highly polished tips aid fine control.
  • 50-time autoclave
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare