Disposable LOOP Tungsten Electrode

$0.00

Shipped From Abroad

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130165-14
Brands:: OBS

Description

 

Features

1. Stainless steel & non-stick finish

2. The hexagonal connection ring fits the pencil locking design.

3. Different shapes fitting for different surgeries

Reviews

There are no reviews yet.

Be the first to review “Disposable LOOP Tungsten Electrode”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsDisposable LOOP Tungsten Electrode removeSS-100 Smoke Evacuation System removeDisposable Subdermal Needle Electrodes removeElectrosurgical Bipolar Forceps removeReusable Electrosurgical Pencil removeOBS-100C LCD Version Dual cold RF Electrosurgical Unit remove
NameDisposable LOOP Tungsten Electrode removeSS-100 Smoke Evacuation System removeDisposable Subdermal Needle Electrodes removeElectrosurgical Bipolar Forceps removeReusable Electrosurgical Pencil removeOBS-100C LCD Version Dual cold RF Electrosurgical Unit remove
Image
SKUSF1033560130165-14SF1033560130165-9SF1033560130165-25SF1033560130165-18SF1033560130165-11SF1033560130165-1
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad

The SS-100 Smoke Evacuation System is designed to protect medical staff and patients from harmful surgical smoke generated during electrosurgical procedures

Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad Electrosurgical Bipolar Forceps are specialized surgical instruments used in electrosurgery. They have two electrodes at the tips, which allow for precise control of electrical current to coagulate, cut, or seal tissue with minimal damage to surrounding areas.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad Unique dual radio frequency design. Combines 4Mhz and 1.7Mhz into one generator. Realizes the best operation result effectively. Suitable for  Plastic, Dermatology, ENT, Ophthalmology, Dentistry, Podiatry and Spinal surgery
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content  
Features
1. Stainless steel & non-stick finish 2. The hexagonal connection ring fits the pencil locking design. 3. Different shapes fitting for different surgeries
Experts have identified harmful smoke which contains a variety of toxic gases and vapors will occur during electrosurgical operation. Medical staff and patients exposure to the smoke in large may cause viral contamination,respiratory problems,nausea and burning eyes.To use a smoke evacuation system is the most effective way of protecting operating room staff and patients from hazards.
 
Features
  • Effective smoke removal: Captures toxic gases and vapors.
  • Compact and portable: Weighs 3.5 kg with a trolley cart for easy mobility.
  • Quiet operation: Works at 55 dB.
  • High efficiency: Processes 3.5-4.2 cubic meters of smoke per hour.
  • Automatic startup: Can be activated by an internal sensor or foot switch
 
Features:
  1. Two Electrodes: The tips of the forceps act as both the active and return electrodes.
  2. Precision Control: Allows for targeted application of electrical energy.
  3. Reduced Risk of Burns: The current is confined between the forceps, minimizing the risk of accidental burns.
  4. Reusable: Often made from stainless steel or titanium and can be sterilized for multiple uses.
  5. Variety of Designs: Available in straight, angled, and bayonet styles to suit different surgical needs.
Uses:
  1. Coagulation: Used to stop bleeding by coagulating blood vessels.
  2. Tissue Cutting: Can be used to cut tissue with precision.
  3. Sealing: Effective in sealing blood vessels and tissue bundles.
  4. Versatility: Used in various surgical fields such as general surgery, gynecology, neurosurgery, and ENT (Ear, Nose, and Throat) surgery.
Features
  • High-quality tried-and-tested materials guarantee a long service life for OBS reusable electrosurgical pencils.
  • Material is durable for high temperature and high press disinfection for more than 30 times.
  • Cost compared to disposable instruments
  • The initial cost of the reusable electrosurgical pencil is easily recouped after only a fraction of the expected number of uses and compares favorably to the cost of disposable pencils.
Features
  • Clinic result proves that higher frequency can get less tissue resists nee. 4Mhz frequency can reduces heat injury a ind carbonizing to tissue at maximum. It realizes low temperature cutting.
  • The antenna pad is unnecessary for skin touch, no current goes through the body, and no possibility of burning
  • No pressure cutting and the pencil is operated easily and it's full of flexibility.
  • No carbonation, less bleeding, and no adhesions.
  • Less pain, scarring, and fast healing after operation.
Technical Parameters
Image
Product Details
OUTPUT MODE 
  • CUT - For micro-smooth cutting
  • BLEND - For cutting with coagulation
  • HEMO - For pure Hemostasis-Coagulation to control most forms of bleeding
  • FULGURATION - For desiccation or fulgurate spark-gap
  • BIPOLAR - For precise coagulation utilizing bipolar energy
INTENDED USE
  • Cutting: snoring, submucosal palatal shrinkage, traditional uvulopalatoplasty (RAUP), myringotomy with effective hemorrhage control, epistaxis treatment, turbinate shrinkage, skin incisions, biopsy, cysts, abscesses, tumors, cosmetic repairs, development of skin flaps, skin tags and blepharoplasty.
  • Blended (cutting and coagulation): snoring, submucosal palatal shrinkage, traditional uvulopalatoplasty (RAUP), myringotomy with effective hemorrhage control, epistaxis treatment, turbinate shrinkage, skin tags, papilloma keloids, keratosis, verrucae. basal cell carcinoma, nevi, fistulas, epithelioma, cosmetic repairs, cysts, abscesses, and development of skin flaps.
  • Hemostasis: control of bleeding, epilation, telangiectasia.
  • Fulguration: basal cell carcinoma, papilloma, cyst destruction, tumors, verrucae, hemostasis.
  • Bipolar: pinpoint precise coagulation, pinpoint hemostasis in any field (wet or dry), snoring, submucosal palatal shrinkage, traditional uvulopalatoplasty (RAUP), myringotomy with effective hemorrhage control, epistaxis treatment and turbinate shrinkage.
Transportation Data :
  • WxHxD:34(L)'23.5(W)*10.6(H) 49(L)*35.5(W)'31(H)cn Weight:8.2kg(NetWeight);12. cm(Generator) i(outer carton) 1kg(Gross Weight)
  • Standard Matching Accessories
  • Instruction for Use: 1pc
  • Power Cord: 1pc
  • Dual Pedal Switch: 1pc
  • Disposable ESU Pencil: 2 pes
  • Reusable Antenna Pad with cable: 1 set
  • Reusable Bipolar Forceps with Cable: 1 set
  • Reusable ESU pencil: 1 pc
  • Reusable Fine Electrode tips (Needle, curved, Needle .Ball): 7pcs
  • Disposable leep Electrode tips: 5pcs
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare