DISSUB ANALYSER

$0.00

Shipped From Abroad

Key Features
  • Proven hyperbaric sensing capability
  • You have the ability to change sensors and maintain the unit in the dockyard, reducing costs and downtime
  • Backlit display for low/no light situations
  • Portable and lightweight making it easy to use around the submarine
  • Externally accessible batteries making for more convenient and safer changing
  • MODBUS RTU over RS485 digital communications, allowing for easy incorporation into your existing platform management system, including JANUS enabled underwater communication networks
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130141-17
Brands:: Analox

Description

Description

The Sub Mk3P Continuous Gas Monitor from Analox is designed specifically to monitor life support gasses aboard a submarine in the event of a distressed submarine (DISSUB) situation.

Portable and lightweight, the Sub Mk3P monitor provides crucial information to the senior survivor about the state of the atmosphere inside the submarine during a time of crisis. This information helps that officer make one of the most challenging decisions any submariner ever has to make – attempt to escape the submarine or wait for rescue teams.

Technical Specification

Temperature & Humidity Sensor

Main Unit

Battery power 4 x ‘D’ alkaline cells (Hyperbaric)
External power 24V dc (9-36V dc), <0.5A
Backup batteries 2 x LR43 alkaline manganese cells
Displays 6 x 4 character LCD, with symbols and LED backlights
Operating temperature -5 to 50°C
Storage temperature -5 to 50°C
Operating pressure 0.7 to 10barA
Operating humidity 0 to 100%RH (Non-condensing)
Standards/ compliance NATO STANAG 1476:2014
ANEP/MNEP 85 & 86 (2014)
DEF STAN 59-411:2014 (EMC)
IACs E10:2014 (MarED) type tested
IP65
CE marked (RoHS)”
Dimensions (W, H, D) 240mm x 198mm x 127mm
Weight 2kg with batteries installed

O2 Sensor

Range 0 to 2000mbar pO2
Accuracy ±10mbar (0 to 300mbar pO2)
±50mbar (300 to 2000mbar pO2)
Response time (t90) 20s
Detection mode Electro-chemical
Shelf life (in sealed packaging) 6 months
Expected life (in air) 12 months

CO2 Sensor

Range 0 to 100mbar pCO2
Accuracy ±10mbar
Response time (t90) 60s
Detection mode Infrared
Expected life (in air) 5 years

Pressure Sensor

Range 0.7 to 10barA (-3 to 90MSW or -10 to 300FSW)
Accuracy (including annual drift) -0.07bar +0.04bar
Response time (t90) <1s
Detection mode Piezoresistive
Expected life (in air) >12 months (Replaced as a part of the O2sensor)
Click here to download Data Sheet
Click here to download Technical Manual

Quick Comparison

SettingsDISSUB ANALYSER removeLOW LEVEL CARBON MONOXIDE MONITOR removePilot-RO Water Purification System removeAx60+ Kiosk removeSuper-Full Touch Screen Water Purification System removeVENUS SOLO OEM SENSOR remove
NameDISSUB ANALYSER removeLOW LEVEL CARBON MONOXIDE MONITOR removePilot-RO Water Purification System removeAx60+ Kiosk removeSuper-Full Touch Screen Water Purification System removeVENUS SOLO OEM SENSOR remove
Image
SKUSF1033560130141-17SF1033560130141-4SF1033560130126-2SF1033560130141-6SF1033560130126-3SF1033560130141-15
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Add to cart
DescriptionShipped From Abroad
Key Features
  • Proven hyperbaric sensing capability
  • You have the ability to change sensors and maintain the unit in the dockyard, reducing costs and downtime
  • Backlit display for low/no light situations
  • Portable and lightweight making it easy to use around the submarine
  • Externally accessible batteries making for more convenient and safer changing
  • MODBUS RTU over RS485 digital communications, allowing for easy incorporation into your existing platform management system, including JANUS enabled underwater communication networks
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Key Features
  • Highly accurate 4-pin sensor
  • >3-year expected cell life
  • Temperature compensation Sub-ppm gas measurement
  • RS485 digital output
  • Optional pressure sensor
  • Easy cell replacement
  • High stability, low drift
  • Easy cell replacement
  • High stability, low drift
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad An economical choice of primary pure water for daily laboratory cleaning , with a water output of 45 - 180 liters per hour, ion retention rate >98%, organic matter retention rate >99% (when MW >200 Daltons), particle and bacteria retention rate >99%, which can meet the requirements of conventional production process water and laboratory utensil cleaning water, and can be used as the inlet water for ultrapure water systems, high-pressure steam sterilizers, environmental test chambers and other instruments.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Key Features
  • Low maintenance
  • Quick Connect System
  • Pre-wired, ready to go
  • Can support up to 4 alarm units
  • Push button for unit testing
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad The Super series uses city tap water as the water source, and can easily and quickly produce secondary RO (reverse osmosis) water, EDI deionized water and UP ultrapure water. It uses a standard two-stage reverse osmosis system and Ionpure EDI technology and modules to continuously produce Class II pure water with a TOC of more than 10MΩ.cm (25℃) and <30ppb, and ultrapure water of 18.2MΩ.cm (25℃). System water output: 10 liters/hour, and the daily output of pure water can reach 240 liters.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Key Features
  • Single gas (user defined)
  • Backward compatible with ADC’s ‘Eclipse’
  • Linearised Output
  • Continuous status signal to check device health
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Description

The Sub Mk3P Continuous Gas Monitor from Analox is designed specifically to monitor life support gasses aboard a submarine in the event of a distressed submarine (DISSUB) situation.

Portable and lightweight, the Sub Mk3P monitor provides crucial information to the senior survivor about the state of the atmosphere inside the submarine during a time of crisis. This information helps that officer make one of the most challenging decisions any submariner ever has to make – attempt to escape the submarine or wait for rescue teams.
Technical Specification

Temperature & Humidity Sensor

Main Unit
Battery power 4 x ‘D’ alkaline cells (Hyperbaric)
External power 24V dc (9-36V dc), <0.5A
Backup batteries 2 x LR43 alkaline manganese cells
Displays 6 x 4 character LCD, with symbols and LED backlights
Operating temperature -5 to 50°C
Storage temperature -5 to 50°C
Operating pressure 0.7 to 10barA
Operating humidity 0 to 100%RH (Non-condensing)
Standards/ compliance NATO STANAG 1476:2014 ANEP/MNEP 85 & 86 (2014) DEF STAN 59-411:2014 (EMC) IACs E10:2014 (MarED) type tested IP65 CE marked (RoHS)"
Dimensions (W, H, D) 240mm x 198mm x 127mm
Weight 2kg with batteries installed
O2 Sensor
Range 0 to 2000mbar pO2
Accuracy ±10mbar (0 to 300mbar pO2) ±50mbar (300 to 2000mbar pO2)
Response time (t90) 20s
Detection mode Electro-chemical
Shelf life (in sealed packaging) 6 months
Expected life (in air) 12 months
CO2 Sensor
Range 0 to 100mbar pCO2
Accuracy ±10mbar
Response time (t90) 60s
Detection mode Infrared
Expected life (in air) 5 years
Pressure Sensor
Range 0.7 to 10barA (-3 to 90MSW or -10 to 300FSW)
Accuracy (including annual drift) -0.07bar +0.04bar
Response time (t90) <1s
Detection mode Piezoresistive
Expected life (in air) >12 months (Replaced as a part of the O2sensor)
Click here to download Data Sheet
Click here to download Technical Manual
Description
The TEC CO is a device for monitoring very low levels of carbon monoxide (CO). This is housed in a robust miniature enclosure rated for IP55 ingress protection, with built-in temperature compensation and an RS485 digital output via Analox communications protocol. The sensors are backwards-compatible with the existing MEC (mini electrochemical) range and offer the same modular approach to gas monitoring.  
Technical Specifications
TEC CO
An economical choice of primary pure water for daily laboratory cleaning , with a water output of 45 - 180 liters per hour, ion retention rate >98%, organic matter retention rate >99% (when MW >200 Daltons), particle and bacteria retention rate >99%, which can meet the requirements of conventional production process water and laboratory utensil cleaning water, and can be used as the inlet water for ultrapure water systems, high-pressure steam sterilizers, environmental test chambers and other instruments
Technical Parameters
Product Model Pilot-RO45 Pilot-RO63 Pilot-RO90 Pilot-RO120 Pilot-RO180
Pure water output* 45L/Hour 63L/Hour 90L/Hour 120L/Hour 180L/Hour
RO reverse osmosis water indicators
 Ion retention rate 98%-99% (when using new RO membrane)
 Organic matter retention rate >99%, when MW>200 Daltons
 Particle and bacteria retention >99%
 bacteria <0.01 cfu/ml (optional 0.2μm imported PES terminal filter)
 Particles (>0.2μm) <1/ml (optional (0.2μm imported PES terminal filter)
Raw water requirements Urban drinking tap water, water temperature 5-45℃, water pressure 1.0-4.0Kgf/ cm2
Size and weight Length × width × height: 640 × 540 × 1110mm; Weight: about 70Kg
Electrical requirements 220V, 50/Hz
power 120W 120W 240W 240W 240W
System Configuration Main unit (including 1 set of purification column) + 2 built-in 15L pressure water buckets + TDS/conductivity test pen + accessory bag
CO2 MONITOR & ALARM DESIGNED FOR KIOSKS

The Ax60+ Kiosk is a CO2 monitor and alarm specifically designed by Analox to alert personnel to a build up/leak of CO2 using a state-of-the-art infrared sensor. The alarm provides both audio and visual alerts in the case of increased levels of carbon dioxide (CO2). Up to four alarms can be added as needed and the unit does not need periodic calibration.

CO2 monitoring with the AX60+ Kiosk
The Ax60+ Kiosk is a smaller version of the popular Ax60+ carbon dioxide (CO2) monitor. It is simple to wall mount in the area where carbon dioxide (CO2) is stored or piped. The Ax60+ Kiosk sensor needs to be installed at a height of 12-18 inches (305-457mm) above the floor – this is because the carbon dioxide (CO2) that leaks from a gas cylinder is denser than ambient air and can collect at low levels. The alarm should be located above the sensor at about head height or at the entrance to the kiosk.  
Technical Specification
Sensor Unit
Performance characteristics
  • New 7.0-inch color touch screen

The new 7-inch color 16:9 widescreen high-resolution full touch screen control system provides a new fingertip touch operation experience.

  • 4-channel water quality and 3-channel flow monitoring on the host

Source water, secondary RO water, EDI deionized water, UP ultrapure w

  • The lab optimized standard two-stage reverse osmosis system

The use of dual pumps, dual membranes and transition water tanks reduces system energy consumption and wastewater, ensuring stable water quality under different source water conditions.

ater, 4-way water quality online monitoring and water quality exceeding standard alarm function.

1-way source water flow statistics, EDI deionized water and UP ultrapure water 2-way high-precision quantitative water extraction function.

  • Standard-50L PE pure water tank

The polyethylene pure water tank with conical bottom design contains an air filter, which can effectively absorb CO2, organic matter and filter bacteria and particles, and can be equipped with UV ultraviolet irradiation sterilization components.

Features and Advantages
  • Built-in 3-pump system with primary and secondary RO booster pumps and circulation disinfection pumps to achieve complete two-stage reverse osmosis, system circulation and disinfection functions
  • Full-level filter element alarm prompt function based on time and flow, showing the used and remaining life of consumables
  • Automatic detection and alarm functions such as system water shortage alarm, water tank full alarm, water quality exceeding standard alarm, consumable life end alarm, water leakage protection alarm, etc. provide safety guarantee
  • Fully automatic RO membrane anti-scaling flushing program (flushing interval and duration can be set) to extend the service life of the RO membrane
  • Built-in SD card, can store and view operation data charts and curves, and can be inserted into a USB flash drive for complete data export, providing data traceability
  • With USB interface system program upgrade function, and optional WIFI module
  • Built-in perpetual calendar clock, convenient for consumables management and service settings
  • Ultrapure water full pipeline dosing disinfection function, just add disinfection tablets to start the one-key disinfection program to ensure high-quality pure water
  • Ultrapure water circulation function, which can be started and shut down freely to maintain low bacterial contamination level in the system
  • Factory and customer secondary passwords, system parameter settings are all password protected to prevent unauthorized changes
  • Compatible with 2 pure water storage methods of pressure water barrels to meet different application needs
  • High-strength all-engineering plastic chassis, ergonomic design, beautiful appearance, no corrosion and rust, ensure the cleanliness of the machine body, in line with GLP specifications
  • Unique 4-door design, pretreatment, RO and ultra-purification components, EDI and TOC modules, water tanks and control components adopt independent modular structures, making system maintenance more convenient
  • Pipes and joints are NSF certified to minimize TOC precipitation in the system and ensure the highest pure water quality
  • Powerful pre-treatment components, combined with 5μm PP transparent filter, KDF composite filter, coconut shell water-washing grade precision activated carbon filter, effectively protect the RO membrane
  • DOW RO reverse osmosis membrane, RO membrane components optimized by The lab, achieve the combination of long life, stability and high desalination rate of RO membrane
  • The new integrated ultra-purification component of DOW resin ensures that the water produced reaches 18.2MΩ.cm and reduces TOC precipitation
  • Ultra-long life 254&185nm dual wavelength UV lamp, combined with medical grade 316L flow hood, effectively sterilizes, reduces TOC, and enhances the system's application range
  • UF ultrafiltration components, molecular weight cut-off: MWCO5000D, effectively remove pyrogens/endotoxins, can be used for precision cell culture and IVF
  • Double-layer terminal sterilizing filter, accuracy: (0.45+0.1)μm, using PES polyethersulfone composite filter membrane, double-layer filtration design to ensure the terminal effluent is sterile
 
Technical Parameters
name Basic Heat removal prototype Low organic matter type Comprehensive Built-in TOC monitor
model Super 10 Super 10F Super 10V Super 10FV Super-TOC10V Super-TOC 10FV
Pure water output 10 L/hour
Ultrapure water output Up to 2.0L/min (when there is water in the water tank)
Ultrapure water index
Resistivity (25℃) 18.2MΩ.cm
Total Organic Carbon TOC* <10ppb <10ppb <3ppb <3ppb <3ppb <3ppb
bacteria <0.01cfu/ml
Particles (>0.1μm) <1/ml
Pyrogens/endotoxins N/A <0.001Eu/ml N/A <0.001Eu/ml N/A <0.001Eu/ml
RNases N/A <1pg/ml N/A <1pg/ml N/A <1pg/ml
Deoxyribonucleases (DNases) N/A <5pg/ml N/A <5pg/ml N/A <5pg/ml
Pure water index
Resistivity* >5MΩ.cm
Total Organic Carbon (TOC)* <30ppb
Silicon Rejection Rate >99.9%
Source water requirements Urban drinking tap water, water temperature 5-45℃, water pressure 1.0-4.0Kgf/cm2
Size and weight Length × width × height: 545 × 470 × 649 mm, weight: about 35 kg
Electrical requirements 220-240V, 50/60Hz
power 240W
System Configuration Host (including 1 set of purification column) + TOC monitor (TOC type) + 50L PE ultrapure water storage tank
   
Description
The Venus Solo OEM sensor is a self-contained unit designed for integration into other manufacturers’ equipment and provides a measurement of gas concentration according to specific user requirements. These GFC (Gas Filter Correlation) sensors generate a signal proportional to the infrared absorption of the measured gas. Providing the gas concentration lies within the designed range of the sensor, the signal is periodically compared with a reference gas. Gas concentrations are indicated through the non-linearised analogue signal output. Gas connections to and from the sensor are via suitable fittings on the gas measuring cell. The Venus Solo OEM Series sensors electrical supply is designed to accept 24V DC (3amp max). Our Venus Solo OEM sensor uses GFC (Gas Filter Correlation) technology to give highly accurate gas measurements. The Venus Solo can be integrated into your own gas analyzer or management system and offers the user a 0-2.5v analogue output.

The sensor is currently available as either: Carbon dioxide (CO2), carbon monoxide (CO), nitrous oxide (N20), methane (CH4) or nitric oxide (NO). If your application requires a different gas, just let us know and we can customise it to your needs. The Venus Solo is used in Military applications to protect submariners from carbon monoxide (CO) exposure.  

Technical Specification
Venus Solo
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
en English
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare